Plan Review Stops For Permit 09050198 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-07-14 |
Time |
13:17 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2009-07-14 |
Time |
13:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-05-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-05-29 |
Time |
13:12 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2009-05-29 |
Time |
13:12 |
Sent To |
|
|
Notes |
2009-05-29 13:57:24 | BUILDING PLAN REVIEW | | PERMIT: 09050198 | | ADD: 1617 N FLAGLER DR, SUITE UP02 | | CONT: EMPIRE DEVELOPMENT SYSTEMS | | TEL: (954)464-9168 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | BUILDING WITH 2009, 2007 EXISTING BUILDING CODE WITH | | 2009 SUPPLEMENTS, THIS REMODEL IS CONSIDERED A LEVEL | | TWO RECONFIGURATION OF WALLS AND SSYTEMS. 2007 EXISTING | | BUILDING CODE 404.1 SCOPE. LEVEL 2 ALTERATIONS INCLUDE | | THE RECONFIGURATION OF SPACE, THE ADDITION OR | | ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION | | OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY | | ADDITIONAL EQUIPMENT. PLEASE UPDATE PLANS. | | | | 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | OF OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | DESIGNED. | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | PROVISIONS OF CHAPTER 3. | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 5, | | TABLE 503, CHAPTER 6, & TABLE 601. | | | | 3) SHEET 3.1 CEILING DETAIL INDICATES THE USE OF HI-HAT | | FURRING BUT FAILS TO INDICATE ATTACHMENT TO THE | | CONCRETE DECK ABOVESIZE OF FASTENER NOR THE SPACING OF | | FASTENER. | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | 4) ALL NEW WORK MUST COMPLY WITH THE FLORIDA BUILDING | | CODE, BUILDING, PLEASE REVIEW REQUIREMENTS FOR FLOOR | | SOUND INSULATION. 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-08-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-08-19 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-08-19 |
Time |
09:35 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-07-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-03 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-03 |
Time |
08:24 |
Sent To |
|
|
Notes |
2009-07-03 08:25:09 | | | ** DENIED 2ND REVIEW ** | | | | 1) NOTE: PLANS SUBMITTED DO NOT CONTAIN ANY DESIGN | | PROFESSIONAL SIGNED, DATED OR SEALED ON ELECTRICAL | | PLANS. PLEASE SEE 481.229, 471.003. PLANS ARE FOR A | | COMMERCIAL HIGH-RISE MUST MEET THESE SECTIONS. | | | | 2) NOTE: PLEASE SEE BEDRM #2 WHICH STILL HAS MISSING | | RECEPTACLE REQUIRED PER 210.52 FOR 2FT OR MORE OF WALL | | SPACE. | | | | 3) NOTE: PREVIOUS NOTES WITH RESPECT TO THE REQUIRED | | CIRCUITING AND SMALL APPLIANCE CIRCUITS FOR KITCHEN, | | DINING AND AREAS OF THE LIKE. THE PLANS NOW INDICATE | | ONLY ONE SMALL APPLIANCE CIRCUIT FOR THE ENTIRE | | KITCHEN. TWO ARE REQUIRED AT A MINIMUM. AT THE TIME | | THIS BUILDING WAS CONSTRUCTED THESE UNITS HAD TWO SMALL | | APPLIANCE CIRCUITS AT A MINIMUM NOW ONLY SHOWS ONE IN | | KITCHEN. | | 210.52B1, 210.11C1, 220.52 | | | | 4) NOTE: PANEL SCHEDULE STILL INDICATES TWO WATER | | HEATERS HOWEVER NONE ARE SHOWN ON PLANS. PLEASE KNOW | | THAT ALL CONTINUOUS LOADS SHALL BE BASED AT 125%. | | 422.13 | | WHEN SHOWING THESE ITEMS ON PLANS, PLEASE BE SURE TO | | INCLUDE THE NEW OR EXISTING DISCONNECTS PER 422.30,31 | | ETC | | | | 5) NOTE: NOTES ON PLANS MENTION TO WIRE SMOKE ALARMS TO | | EXISTING FIRE ALARM SYSTEM. PLEASE CHECK WITH THE FIRE | | MARSHAL AS UNIT SINGLE STATION DEVICES SHOULD NOT BE | | CONNECTED TO BASE BUILDING. IT MAY BE A TROUBLE SIGNAL | | OF SOME TYPE. PLEASE CHECK WITH FIRE PLAN REVIEW. | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-05-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-22 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-22 |
Time |
08:47 |
Sent To |
|
|
Notes |
2009-05-22 08:47:22 | **DENIED ** | | | | 1) NOTE: PLEASE COMPLETE ALL CIRCUITING ON PLANS PER | | MINIMUM CODE REQUIREMENTS. | | PLEASE SEE DINING, BREAKFAST AREAS AND AREA OF THE LIKE | | PER 210.52B1 ARE REQUIRED TO BE ON ONE OR MORE OF THE | | SMALL APPLIANCE CIRCUITS. THE CIRCUIT IN ONE OF THESE | | AREAS IS SHOWN AS CIRCUIT #17 WHICH IS A BEDROOM ARC | | FAULT CIRCUIT WHICH IS NOT PERMITTED. | | ANOTHER WOULD BE THE SMOKE ALARMS. PLEASE ALSO SEE | | 210.12 FOR REQUIRED ARC FAULT PROTECTION. | | PLEASE ALSO BE SURE TO SEE OTHER CIRCUITS ON PANEL | | SCHEDULE WHICH DO NOT GO TO ANYTHING. 408.4. | | | | 2) NOTE: PLANS APPEAR TO HAVE LIGHT LOCATIONS WHICH ARE | | SWITCHED FROM MORE THAN ONE LOCATION HOWEVER THE | | SWITCHES ARE NOT SHOWN AS 3-WAYS. PLEASE ADJUST. NEC | | 300. | | FBC 106.1.1 | | | | 3) NOTE: PLEASE SEE 422.13 FOR STORAGE TYPE WATER | | HEATERS WHICH REQUIRES LOAD TO BE FIGURED AT 125%. | | | | 4) NOTE: PLEASE BE SURE THE PLANS STATE THE FOLLOWING | | CODES AT A MINIMUM. | | 2002 NFPA-72 | | 2007 FBC W/ 2009 REVISIONS | | | | 5) NOTE: PLEASE SEE 210.52 FOR RECEPTACLES SPACING. | | THERE ARE SEVERAL LOCATIONS IN WHICH RECEPTACLES ARE | | REQUIRED. SOME NEED TO BE ADDED AND SOME NEED TO BE | | RELOCATED IN ORDER TO BE CODE COMPLIANT. | | | | 6) NOTE: PLEASE SEE 210.11C1, AND 220.52 FOR REQUIRED | | LOAD TO BE FIGURED FOR THE ONE OR MORE SMALL APPLIANCE | | CIRCUITS. THIS IS RELEVANT TO THE COMMENT NUMBER ONE | | ABOVE. WHEN YOU HAVE MORE THAN TWO SMALL APPLIANCE | | CIRCUITS FOR DINING ROOMS, AREAS LIKE BREAKFAST AREAS | | AND THE LIKE, EACH ONE REQUIRES 1500 VA FOR EACH. | | | | 7) NOTE: PLEASE SEE 210.11C3 FOR RECEPTACLE MISSING | | ALONG KITCHEN COUNTER SPACE. PLEASE ALSO SEE 210.8A6 | | FOR REQUIRED GFCI PROTECTION. | | | | * IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-08-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-08-12 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-08-12 |
Time |
12:26 |
Sent To |
E |
|
Notes |
2009-08-12 12:27:49 | *****APPROVED***** | | | | PLAN SHEETS 2.1 AND 4.1 WERE STAMPED, INITIALED, AND | | DATED. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2009-07-06 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-07-06 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-07-06 |
Time |
14:40 |
Sent To |
|
|
Notes |
2009-07-06 14:58:21 | *****PROVISO***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | BEEN ADDRESSED; THE APPROPIATE PLAN SHEETS (2.1 & 4.1) | | SHALL BE FIRE-STAMPED WHEN THE OTHER REVIEWERS' AS WELL | | AS THE FOLLOWING COMMENT HAS BEEN SATISFIED: IN | | REFERENCE TO NOTE #3 ON SHEET 4.1, PLEASE BE ADVISED | | THAT SMOKE ALARMS SHALL SOUND ONLY WITHIN AN INDIVIDUAL | | DWELLING UNIT AND SHALL NOT ACTUATE THE BUILDING FIRE | | ALARM SYSTEM (UNLESS OTHERWISE PERMITTED BY WEST PALM | | BEACH FIRE PREVENTION). | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-05-26 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-05-26 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-05-26 |
Time |
09:35 |
Sent To |
|
|
Notes |
2009-05-26 10:38:18 | *****DENIED***** | | | | | | 1. STRUCTURES UNDERGGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | EDITION. | | | | 2. LIFE SAFETY TO COMPLY WITH NFPA 101 - 2006 EDITION | | WHICH HAS BEEN IN EFFECT SINCE DECEMBER 31ST, 2008. | | | | 3. SPECIFY THE INTERIOR FINISH MATERIAL FOR THE NEW | | WALLS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-08-10 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-07-22 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-07-22 |
Time |
13:18 |
Sent To |
|
|
Notes |
2009-08-10 13:17:38 | GAVE TO BILL T. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-06-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-06-19 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-06-19 |
Time |
15:10 |
Sent To |
|
|
Notes |
2009-06-19 15:11:48 | | | | | TO # B-1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-06-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-17 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-11 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-07-13 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-07-13 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-07-13 |
Time |
15:17 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-06-08 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-06-08 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-06-08 |
Time |
09:24 |
Sent To |
|
|
Notes |
2009-06-08 09:35:41 | MECH SCOPE OF WORK OK. HOWEVER, PLANS (PROJECT DATA | | TABLE ON PG 2.1) NEED TO BE UPDATED TO REFLECT THE CODE | | IN EFFECT AT TIME OF PERMIT APPLICATION. THE 2007 FBC | | W/ 2009 SUPPLEMENT IS IN EFFECT AS OF MARCH 1, 2009. | | ALSO, THE LEVEL OF ALTERATION AS STATED IN THE PROJECT | | DATA TABLE IS INCORRECT. THE PROPOSED SCOPE OF WORK | | CONSTITUTES A LEVEL 2 ALTERATION AS IT INVOLVES A | | RECONFIGURATION OF SPACE. SEE FBC-EB SECTION 404.1. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2009-06-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-17 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-17 |
Time |
08:58 |
Sent To |
|
|
Notes |
2009-06-17 09:10:27 | BATHROOM PLUMBING FIXTURE CHANGE OUT ONLY. PLUMBING | | PERMIT REQUIRED. |
|
|