Plan Review Details - Permit 09050141
Plan Review Stops For Permit 09050141 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-05-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-19 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-19 |
Time |
16:36 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-14 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-18 |
Time |
16:12 |
Sent To |
PC |
|
Notes |
2009-05-14 09:03:06 | RESIDENTIAL (R3) SHUTTERS, BUILDING REVIEW CHECKLIST. | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009 | | REVISIONS. | | | | 1- ACCORDING TO THE 2009 REVISIONS TO THE 2007 FLORIDA | | RESIDENTIAL CODE THIS BUILDING IS LOCATED ON EXPOSURE | | "C" NOT "B" AS SHOWN ON CALCULATIONS DONE BY THE | | ENGINEER. SEE REVISED SECTIONS R301.2.1.4 THRU | | R301.2.1.4.3 AND REVISE EXPOSURE AND DESIGN PRESSURES | | AS REQUIRED. | | | | 2- SHUTTERS INSTALLATION SCHEDULE SUBMITTED: | | A) CLEARLY IDENTIFY EDGE DISTANCE FOR EACH OPENING. | | CLARIFY EDGE DISTANCE FOR OPENING #1 AT TOP AND BOTTOM. | | ONLY BOTTOM WAS SPECIFIED. CLARIFY WHY THE REST OF THE | | OPENINGS THE EDGE DISTANCE IS N/A? SPECIFY THE EDGE | | DISTANCE FOR EACH OPENING. DECREASE ANCHOR SPACING AS | | REQUIRED ON SHEET 5 OF 5 OF SHUTTERS DRAWINGS SUBMITTED | | IF THE EDGE DISTANCE IS LESS THAN 3" FOR CONCRETE AND | | CONCRETE BLOCK INSTALLATIONS. | | | | B) OPENINGS #2, #3, #4 AND #7 SPECIFY CONCRETE AS THE | | SUBSTRATE TO RECEIVE THE SHUTTERS AT TOP AND BOTTOM OF | | SHUTTERS. PROVIDE PROOF THAT WINDOW SILL IS POURED | | CONCRETE WITH 3000PSI CONCRETE NOT FILLED CONCRETE | | BLOCK OR USE CONCRETE BLOCK ANCHOR CHART. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-05-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-05-18 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-18 |
Time |
16:13 |
Sent To |
|
|
Notes |
2009-05-18 16:14:02 | SENT TO J GOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-14 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-13 |
Time |
14:28 |
Sent To |
|
|
Notes |
2009-05-13 14:29:29 | UNDER $ 5000 |
|
|
|