Plan Review Stops For Permit 09050121 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2010-04-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-04-20 |
Time |
08:15 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2010-04-20 |
Time |
08:15 |
Sent To |
|
|
Notes |
2010-04-20 08:18:14 | REVISION #3 DATE 3/2010 A-1, A-2 & BARON EXT DOOR | | NOA07-0328.05 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-11-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-11-18 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2009-11-18 |
Time |
16:56 |
Sent To |
|
|
Notes |
2009-11-18 16:57:51 | BUILDING PLAN REVIEW | | PERMIT: 09050121 | | ADD: 5115 S DIXIE HWY | | CONT: PRO-BUILT | | TEL: (561)444-3008 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | NOVEMBER 18/2009 | | | | BUILDING PROVISO: | | | | APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). | | | | PROVIDE BEFORE FRAMING INSPECTION: | | | | 1) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 1A) LINTEL | | 1B) EXTERIOR DOOR | | | | 2) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITTING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES | | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER | | NOTICE. | | | | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM | | - 5:00 PM. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | SURVEY: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-08-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-08-18 |
Time |
13:34 |
Rev Time |
0.70 |
Received By |
jwitmer |
Date |
2009-08-18 |
Time |
13:28 |
Sent To |
|
|
Notes |
2009-08-18 13:32:16 | BUILDING PLAN REVIEW | | PERMIT: 09050121 | | ADD: 5115 S DIXIE HWY | | CONT: PRO-BUILT | | TEL: (561)444-3008 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | AUGUST 18/2009 | | | | BUILDING PROVISO: | | | | APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). | | | | PROVIDE BEFORE FRAMING INSPECTION: | | | | 1) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 1A) LINTEL | | 1B) EXTERIOR DOOR | | | | 2) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITTING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | | | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES | | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER | | NOTICE. | | | | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM | | - 5:00 PM. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | SURVEY: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-05-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-05-15 |
Time |
12:00 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2009-05-15 |
Time |
11:30 |
Sent To |
|
|
Notes |
2009-05-15 13:11:33 | BUILDING PLAN REVIEW | | PERMIT: 09050121 | | ADD: 5115 S DIXIE HWY | | CONT: PRO-BUILT | | TEL: (561)444-3008 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | BUILDING WITH 2009 SUPPLEMENTS, 2007 EXISTING BUILDING | | CODE W/ 2009 SUPPLEMENTS, PLEASE UPDATE APPLICABLE | | CODES. | | | | 2) CODE ANALYSIS INDICATES THIS TO BE A TYPE IV | | BUILDING WHICH IS HEAVY TIMBER, PLEASE CORRECT, TABLE | | 503. | | | | 3) SHEET A-1 DOOR# 1 DOES NOT INDICATE THIS IS A NEW | | CUT IN OPENING, PLEASE SEE INTERIOR DEMO PERMIT | | 09040632 AND NOTE # 5 WHICH DEALS WITH THE NEW DOORWAY | | BEING CUT INTO THE WALL AND BUILDING PROVISO: DEMO | | NOTE# 5 TO BE DETERMINED BY ZONING DEPARTMENT , BLDG IS | | OK WITH SET BACK REQUIREMENTS TABLE 602. THE NEW PLANS | | FAIL TO INDICATE HOW THE BLOCK WALL WILL BE FITTED WITH | | COLUMNS AND EITHER BEAM OR LINTEL. ALSO MISSING PRODUCT | | APPROVALS FOR THE NEW LINTEL & DOOR OPENING. | | | | 4) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 4A) LINTEL | | 4B) EXTERIOR DOOR | | | | 5) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 6) THE SWING RESTROOM DOOR AND DOOR # 4 ARE MISSING THE | | REQUIRED 18" LATCH SIDE. | | 11-4.13.6 MANEUVERING CLEARENCES AT DOORS. MINIMUM | | MANEUVERING CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC | | OR POWER-ASSISTED SHALL BE AS SHOWN IN | | FIG. 25. THE FLOOR OR GROUND AREA WITHIN THE REQUIRED | | CLEARANCES SHALL BE CLEAR & LEVEL. | | | | 7) WINDOW E IS A HAZARDOUS LOCATION: WILL REQUIRE | | SAFETY GLAZING. 2406.3(6). | | | | 8) THIS MAY BE A CHANGE OF OCCUPANCY : BEFORE A PERMIT | | TO CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST BE PAID | | TO PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF PLANS | | MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE PAID | | RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | (561)233-5025 FOR MORE INFORMATION. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2009-12-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-12-17 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-12-17 |
Time |
14:06 |
Sent To |
PC |
|
Notes |
2009-12-17 15:46:38 | | | | | | | PROVISO | | | | PROVIDE LIGHTING POWER DENSITY PER 13-415.AB.5 FBC 2007 | | AND 13-415 AB 2.2. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2009-11-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-11-19 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-11-19 |
Time |
10:54 |
Sent To |
|
|
Notes |
2009-11-19 11:34:27 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2006, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} FROM PREVIOUS REVIEW WITH ARTICLE FOR EXPLANATION: | | 1} 13-415.AB.5 INTERIOR LIGHTING POWER, SCOPE. THE | | INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR A | | SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | SHALL BE DETERMINED BY THE SPACE-BY-SPACE METHOD | | DESCRIBED IN SECTION 13-415.B.1. TRADE-OFFS OF INTERIOR | | LIGHTING POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING | | FOR WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN | | USED ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING | | POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | 13-415.AB.5.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | SECTION13-415.B.1*** SHOW COMPLIANCE ON THE PLAN. THIS | | CAN BE DEMONSTRATED ON THE PLANS INDICATING THE | | WATTAGES OF THE LUMINAIRES CHOSEN FOR THE PROJECT | | CONFORM TO THE DENSITY REQUIREMENTS. INDICATE WATTAGES | | ON THE FIXTURE SCHEDULE TO CORRELATE WITH THE ONES IN | | THE CALCULATIONS. | | | | 2} EMERGENCY ILLUMINATION PER NFPA-101 7.8 (2006), AND | | CIRCUITED PER 700.12 NEC (F)(4). INDICATE SAME ON | | PLANS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-08-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-08-26 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-08-26 |
Time |
17:01 |
Sent To |
|
|
Notes |
2009-08-26 17:01:50 | | | | | | | | | | | ** DENIED REVIEW 2ND REVIEW ** | | | | ** THERE IS STILL INFORMATION NEEDED FOR MINIMUM CODE | | COMPLIANCE. THERE IS INFORMATION NOT YET SUBMITTED. | | THERE ARE NEW COMMENTS BASED ON SOME NEW INFORMATION. | | ** THERE MAY BE NEW COMMENTS ON THE FOLLOWING REVIEW AS | | THERE ARE ITEMS NOT YET SUBMITTED FOR CODE COMPLIANCE. | | | | 1) NOTE: NO LIGHTING PERFORMANCE CALCULATIONS PER | | 13-415.AB.5, 13-400.B.0.4, 13-415.B.1, .2.2 SUBMITTED. | | MUST MEET MINIMUM PRESCRIPTIVE REQUIREMENTS AS ORIGINAL | | NOTED. | | ** KEEP IN MIND ALL FIXTURES ON LEGEND NEED TO BE | | SPECIFIC. BASED ON THE TYPE OF FIXTURES SHOWN THE | | WATTAGE WOULD BE OVER THE ALLOWANCES UNDER FBC CHAPTER | | 13 | | | | 2) NOTE: EXTERIOR LIGHTING CONTROLS STATES * TIMER*. | | PLEASE BE SURE TO SEE 13-415.AB.1.4 FOR TYPE OF | | CONTROLS REQUIRED AND INDICATE. | | | | 3) NOTE: ALL EMERGENCY LIGHTING SHOWN ON PLANS SHALL BE | | CIRCUITED PER 700.12F. | | | | 4) NOTE: THERE NEEDS TO BE A SYMBOL LEGEND FOR DEVICES. | | NOTE ON PLANS MENTIONS ALL SWITCHES TO BE * MOTION | | SENSOR TYPE*. IS THIS CORRECT? ARE THESE MEANT TO BE | | *OCCUPANCY SENSORS? | | | | 5) NOTE: NO PANEL SCHEDULE OR SIZE OF NEW OR EXISTING | | PANEL(S), LOCATION(S) OF SERVICE ETC SUBMITTED. CAN NOT | | VERIFY SEVERAL ITEMS FOR CODE COMPLIANCE AT THIS TIME. | | NO NEW LOCATIONS FOR RECEPTACLES. THERE IS A DEMO PLAN | | HOWEVER NO NEW POWER PLAN. | | LOADS, CIRCUITS, OVER CURRENT PROTECTION ETC. | | 220,215.3,230.42,408.4,310.16 ETC | | 220.12,220.14,220.44,220.43,220.42 ETC | | THERE ARE TOO MANY CODE SECTIONS TO REFERENCE. | | FBC 106.1.1,106.1.2,106.3.5.1.2 ADDITIONAL INFORMATION, | | CLARITY. | | | | 6) NOTE: NEW OR EXISTING SIGN CIRCUIT PER 600.5 | | | | 7) NOTE: PLANS INDICATE NEW 60 GALLON WATER HEATER. SEE | | 422.13 FOR SIZING OF BRANCH CIRCUITS AND CONTINUOUS | | LOAD AT 125%. | | | | 8) NOTE: PLANS SHOW NEW PROPOSED WASHER AND DRYER | | HOWEVER NO ELECTRICAL RECEPTACLES, INFORMATION, LOADS, | | CIRCUITING ETC. SOME OF THE SAME INFORMATION AS NOTED | | ABOVE IN COMMENT #5. | | 220.44,220.54 | | | | 9) NOTE: THERE IS A HOLD IN SYSTEM. THE ORIGINAL PERMIT | | APPLICATION WAS NOT SUBMITTED BACK WITH PLANS. THIS IS | | STILL NEEDED AND REQUIRED. | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-05-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-18 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-18 |
Time |
15:12 |
Sent To |
|
|
Notes |
2009-05-18 15:12:37 | **DENIED REVIEW ** | | | | 1) NOTE: PLEASE SUBMIT ELECTRICAL PLANS FOR SCOPE OF | | WORK FOR REMODEL. PLEASE SEE NEC 2005 AND 2007 FBC WITH | | 2009 REVISIONS. | | PLEASE BE SURE TO SEE CHAPTER 13 FOR PRESCRIPTIVE CODE | | REQUIREMENTS. | | | | ** THE NOTE ON PLANS FOR LIGHTING CONTROLS IN LIEU OF | | DETAILS REQUIRED FOR MINIMUM CODES IS NOT ACCEPTABLE. | | | | FBC 106.1,106.1.1,106.1.2,106.3.5.1.2 | | | | | | | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-11-18 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-11-18 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-11-18 |
Time |
13:57 |
Sent To |
|
|
Notes |
2009-11-18 14:08:53 | *****APPROVED***** | | | | AS PREVIOUSLY (8/19/09) DONE, PLAN SHEETS D-1 AND A-1 | | WERE STAMPED, INITIALED, AND DATED IN ADDITION TO THE | | NEWLY ADDED E-1 SHEET. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-08-19 |
Time |
|
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-08-19 |
Time |
14:21 |
Sent To |
|
|
Notes |
2009-08-19 14:34:17 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | BEEN ADDRESSED; PLAN SHEETS D-1 AND A-1 WERE STAMPED, | | INITIALED, AND DATED. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-05-15 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-05-15 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-05-15 |
Time |
16:47 |
Sent To |
|
|
Notes |
2009-05-15 22:37:36 | *****DENIED***** | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | EDITION. | | | | 2. THE 2007 FLORIDA FIRE PREVENTION FIRE CODE (BASED ON | | NFPA 101 - LIFE SAFETY CODE - 2006 EDITION AND NFPA 1 | | -UNIFORM FIRE CODE - 2006 EDITION) SHALL BE REFERENCED. | | | | 3. ON SHEET A-1, PROVIDE A DIRECTIONAL GUIDE INDICATIVE | | TO THE LAYOUT OF THE BUILDING. | | | | 4. IN THE FIXTURE LEGEND ON SHEET A-1, PLEASE | | VERIFY/CLARIFY AS TO WHETHER THE SYMBOL FOR THE WALL | | MOUNT EXIT LIGHT SHOULD BE EMERGENCY LIGHTS INSTEAD. | | | | 5. WHEN COMPARING THE PROPOSED CEILING PLAN WITH THE | | PROPOSED FLOOR PLAN AS SHOWN ON SHEET A-1, THERE | | APPEARS THAT A CEILING MOUNT EXIT LIGHT/EMERGENCY COMBO | | ABOVE A RESTROOM DOOR. HOW WILL PATRONS NOT BE CONFUSED | | AS TO THE TRUE LOCATION OF THE EXIT. | | | | 6. SHOW THE LOCATION OF THE 2A:10BC RATED FIRE | | EXTINGUISHER(S) WHICH SATISFY THE 75 TRAVEL DISTANCE. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET | | EACH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2010-04-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-04-12 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-04-12 |
Time |
09:28 |
Sent To |
|
|
Notes |
2010-04-12 09:29:18 | SENT TO C27. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-11-04 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-11-03 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-11-03 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-08-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-08-07 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-08-07 |
Time |
16:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-05-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-21 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-07 |
Time |
09:59 |
Sent To |
|
|
Notes |
2009-05-07 10:00:10 | BOB BOARD #7 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2009-12-09 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-11-06 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-11-06 |
Time |
11:11 |
Sent To |
|
|
Notes |
2009-11-06 11:18:31 | PROVISO: | | | | PROVIDE A MINIMUM OF 400 CFM OUTSIDE AIR FOR THE | | PROPOSED NEW USE OF THIS SPACE IN ACCORDANCE WITH | | FBC-EB 901.2 AND 909.1. A TEST AND BALANCE REPORT SHALL | | BE PROVIDED TO VERIFY VENTILATION RATES PRIOR TO FINAL | | INSPACTION IN ACCORDANCE WITH FBC-M 403.3.4. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2009-09-01 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-09-01 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-09-01 |
Time |
16:17 |
Sent To |
|
|
Notes |
2009-09-01 16:18:19 | NO MECHANICAL PLANS OR ENERGY CALCULATIONS SUBMITTED. | | PREVIOUS REVIEW COMMENTS NOT ADDRESSED. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-05-15 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-05-15 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-05-15 |
Time |
16:15 |
Sent To |
|
|
Notes |
2009-05-15 16:17:47 | REVIEW #: 1ST | | ACTION: DENIED | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. SHOW HOW BALANCED RETURN IS TO BE ACHIEVED IN ALL | | HABITABLE ROOMS IN ACCORDANCE WITH FBC-M 601.4. | | | | 2. PROVIDE VENTILATION CALCULATIONS FOR ALL SPACES IN | | ACCORDANCE WITH FBC-EB 709.1 AND FBC-M 403.3. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2009-12-17 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2009-12-17 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2009-12-17 |
Time |
13:26 |
Sent To |
|
|
Notes |
2009-12-17 13:29:13 | INTERIOR ALTERATION TO A PRIMARY FUNCTION WITHOUT A | | CHANGE IN OCCUPANCY. BOTH DISPROPORTIONATE COST AND | | TECHNICAL INFEASIBLITY APPLY TO THIS PROJECT. BASED | | UPON DISCUSSION AND REVIEW OF THE PROJECT ESTIMATED | | BUDGET AND DOCUMENTATION PROVIDED BY THE ARCHITECT OF | | RECORD IT NOW APPEARS CLEAR THAT THE COST TO COMPLETELY | | REBUILD A COMPLIANT BATHROOM WILL EXCEED 20% OF THE | | PROJECT COST. FURTHER IT IS A CHANGE IN USE WITHOUT A | | CHANGE IN OCCUPANCY IN ACCORDANCE WITH THE FLORIDA | | EXISTING BUILDING CODE. SINCE THE CHANGE IN USE DOES | | NOT CREATE A MORE INTENSIVE USE OF THE EXISTING | | PLUMBING FIXTURES THE EXISTING FIXTURES ARE DEEMED | | "COMPLIANT" BY RULE. ACCORDINGLY THE EXISTING BOTTLE | | WATER DISPENSER IS ALLOWED TO REMAIN AS THE SOLE | | DRINKING FOUNTAIN PURSUANT TO THE PRIOR RULE. THEREFORE | | ONLY THE IMPROVEMENTS TO ACCESIBILITY AS PROPOSED BY | | THE ARCHITECT ARE REQUIRED AND ARE DEEMED ACCEPTABLE TO | | THIS REVIEWER AT THE TIME OF REVIEW. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2009-11-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-11-18 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-11-18 |
Time |
09:45 |
Sent To |
|
|
Notes |
2009-11-18 10:42:52 | DENIED | | REFERENCE: | | FBC-2007 W/2009 SUPPLEMENTS | | FBC-2007 EXISTING BUILDING | | FBC-2007 PLUMBING | | FBC-2007 CHAPTER 1 | | FBC-2007 CHAPTER 11 | | | | ****FROM PREVIOUS REVIEW: | | | | ******FROM PREVIOUS REVIEW: | | | | 1. SHT A-1 THE PROPOSED TOILET ROOM SHALL BE | | ACCESSIBLE. THE MINIMUM WIDTH FOR AN ACCESSIBLE TOILET | | ROOM IS 5'3" FINISHED WIDTH. THE PLANS SHOW 5'0". | | SECTION 405.3.1 & FIG. 28. SECTION 11-4.1.6(1)(B). | | *****NO RESPONSE, COMMENT NOT ADDRESSED. | | ******NO RESPONSE, COMMENT NOT ADDRESSED. | | | | 2. SHT A-1 SHOW THE TURNING AREA IN THE ACCESSIBLE | | TOILET ROOM. SECTION 11-4.22.3. | | *****NO RESPONSE, COMMENT NOT ADDRESSED. | | ******NO RESPONSE, COMMENT NOT ADDRESSED. | | | | 3. SHT A-1. BATHROOM NOTES #3 INDICATES THE GRAB BAR | | BEHIND THE W/C TO BE 24 INCHES LONG AND MAXIMUM 12" | | FROM THE CORNER. THE GRAB BAR BEHIND THE W/C IS | | REQUIRED TO BE A MINIMUM 36" LONG AND A MAXIMUM 6" FROM | | THE CORNER. SEE SECTION 11-4.16.4. | | *****NO RESPONSE, COMMENT NOT ADDRESSED. | | ******NO RESPONSE, COMMENT NOT ADDRESSED. | | | | 4. OK | | 5. OK | | 6. OK | | | | ********NEW COMMENT******** | | | | 1B. SUBMIT A DETAIL FOR THE REQUIRED DRINKING FOUNTAIN | | SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH ALL | | SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A) | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | STOOPING. | | ******NO RESPONSE, COMMENT NOT ADDRESSED. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2009-08-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-08-14 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-08-14 |
Time |
13:45 |
Sent To |
|
|
Notes |
2009-08-14 13:56:29 | DENIED | | REFERENCE: | | FBC-2007 W/2009 SUPPLEMENTS | | FBC-2007 EXISTING BUILDING | | FBC-2007 PLUMBING | | FBC-2007 CHAPTER 1 | | FBC-2007 CHAPTER 11 | | | | ****FROM PREVIOUS REVIEW: | | | | 1. SHT A-1 THE PROPOSED TOILET ROOM SHALL BE | | ACCESSIBLE. THE MINIMUM WIDTH FOR AN ACCESSIBLE TOILET | | ROOM IS 5'3" FINISHED WIDTH. THE PLANS SHOW 5'0". | | SECTION 405.3.1 & FIG. 28. | | *****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | 2. SHT A-1 SHOW THE TURNING AREA IN THE ACCESSIBLE | | TOILET ROOM. SECTION 11-4.22.3. | | *****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | 3. SHT A-1. BATHROOM NOTES #3 INDICATES THE GRAB BAR | | BEHIND THE W/C TO BE 24 INCHES LONG AND MAXIMUM 12" | | FROM THE CORNER. THE GRAB BAR BEHIND THE W/C IS | | REQUIRED TO BE A MINIMUM 36" LONG AND A MAXIMUM 6" FROM | | THE CORNER. SEE SECTION 11-4.16.4. | | *****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | 4. OK | | 5. OK | | | | 6. PER TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED. | | PLEASE SHOW THE LOCATION OF THE REQUIRED DRINKING | | FOUNTAIN. | | *****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | ********NEW COMMENT******** | | | | 1B. SUBMIT A DETAIL FOR THE REQUIRED DRINKING FOUNTAIN | | SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH ALL | | SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A) | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | STOOPING. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-05-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-21 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-21 |
Time |
13:49 |
Sent To |
|
|
Notes |
2009-05-21 15:26:49 | DENIED | | REFERENCE: | | FBC-2007 W/2009 SUPPLEMENTS | | FBC-2007 EXISTING BUILDING | | FBC-2007 PLUMBING | | FBC-2007 CHAPTER 1 | | FBC-2007 CHAPTER 11 | | | | 1. SHT A-1 THE PROPOSED TOILET ROOM SHALL BE | | ACCESSIBLE. THE MINIMUM WIDTH FOR AN ACCESSIBLE TOILET | | ROOM IS 5'3" FINISHED WIDTH. THE PLANS SHOW 5'0". | | SECTION 405.3.1 & FIG. 28. | | | | 2. SHT A-1 SHOW THE TURNING AREA IN THE ACCESSIBLE | | TOILET ROOM. SECTION 11-4.22.3. | | | | 3. SHT A-1. BATHROOM NOTES #3 INDICATES THE GRAB BAR | | BEHIND THE W/C TO BE 24 INCHES LONG AND MAXIMUM 12" | | FROM THE CORNER. THE GRAB BAR BEHIND THE W/C IS | | REQUIRED TO BE A MINIMUM 36" LONG AND A MAXIMUM 6" FROM | | THE CORNER. SEE SECTION 11-4.16.4. | | | | 4. SUBMIT A SANITARY ISOMETRIC RISER DIAGRAM SHOWING | | ALL PIPE SIZES, TRAPS, VENTS, POINTS OF CONNECTION & | | POINTS OF TERMINATION. SECTION 106.3.5.1.3(4)(6)(13). | | | | 5. SUBMIT A WATER ISOMETRIC RISER DIAGRAM SHOWING ALL | | PIPE SIZES, VALVES, WATER HAMMER ARRESTORS, POINTS OF | | CONNECTION ETC. SECTIONS 106.3.5.1.3(3)(5)(8)(13) & | | 604.9. | | | | 6. PER TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED. | | PLEASE SHOW THE LOCATION OF THE REQUIRED DRINKING | | FOUNTAIN. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2009-11-20 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-11-20 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-11-20 |
Time |
15:04 |
Sent To |
|
|
Notes |
2009-11-20 15:26:52 | ZONING PLAN REVIEW | | | | PERMIT NO.: 09050121 | | ADDRESS: 5115 SOUTH DIXIE HIGHWAY | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: 561.444.3008 | | SCOPE OF REVIEW: INTERIOR AND EXTERIOR ALTERATIONS TO | | EXISTING SITE. | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1) ALL NEW PARKING LOT RESTRIPING SHALL BE DONE IN | | ACCORDANCE TO THE STRIPING STANDARDS OF THE CITY???S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS). | | | | 2) ACCESSIBLE PARKING SIGN SHALL BE LOCATED OUTSIDE OF | | THE VEHICLE OVERHANG AREA. | | | | 3) ALL LANDSCAPING WITHIN THE VISIBILITY TRIANGLE SHALL | | NOT EXCEED 18 INCHES IN HEIGHT. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2009-08-25 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-08-25 |
Time |
17:52 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-08-25 |
Time |
17:52 |
Sent To |
|
|
Notes |
2009-08-25 18:05:20 | ZONING PLAN REVIEW | | | | PERMIT NO.: 09050121 | | ADDRESS: 5112 SOUTH DIXIE HIGHWAY | | CONTRACTOR/CONTACT: BRYAN ENGLERT | | TELEPHONE NO.: 561.392.0388 | | SCOPE OF REVIEW: INTERIOR (AND EXTERIOR?) ALTERATION OF | | EXISTING SPACE. | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS...THE FOLLOWING ARE REPEAT COMMENTS | | (ADDITIONAL INFORMATION IS PROVIDED IN ALL CAPS): | | | | 1) PERMIT APPLICATION INDICATES INTERIOR RENOVATION, | | WHILE PLANS SHOW EXTERIOR/SITE MODIFICATIONS. PLEASE | | ENSURE THAT THE PERMIT APPLICATION AND THE PLANS ARE | | CONSISTENT REGARDING THE SCOPE OF WORK. IT WAS UNCLEAR | | AS TO WHETHER OR NOT THE SCOPE HAS BEEN REVISED AS THE | | PERMIT APPLICATION WAS NOT INCLUDED WITH THE | | RESUBMITTAL PACKAGE. | | | | THE FOLLOWING COMMENTS NEED TO BE ADDRESSED AS A RESULT | | OF THE POTENTIAL NEW SCOPE (EXTERIOR WORK) AND THE | | SUBMITTAL OF NEW/REVISED PLANS: | | | | 1) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY SHALL BE | | PROVIDED. | | | | 2) THE SITE PLAN SHALL TO SCALE. | | | | 3) A PARKING STALL STRIPING DETAIL SHALL BE PROVIDED | | INDICATING COMPLIANCE WITH THE CITY'S ZLDRS. | | | | 4) A DETAIL SHALL BE PROVIDED SHOWING THE PROPOSED | | WHEEL STOPS AND SHALL BE IN COMPLIANCE WITH THE CITY'S | | ZLDRS. | | | | 5) A SITE DATA TABLE SHALL BE PROVIDED SHOWING TOTAL | | ACRES OF THE PROJECT; TOTAL GROSS BUILDING SQUARE | | FOOTAGE; PERCENTAGE OF OPEN SPACE, LANDSCAPING, | | BUILDING COVERAGE, AND IMPERMEABLE SURFACE; DENSITY; | | PARKING CALCULATIONS; FAR; ETC. | | | | 6) THE DEMOLITION PLAN STILL SHOWS STORAGE OF A | | RECREATIONAL VEHICLE. PURSUANT TO SECTION 94-444(C) OF | | THE CITY'S ZLDRS, OUTDOOR STORAGE SHALL NOT BE | | PERMITTED UNLESS CODE-REQUIRED SCREENING IS INSTALLED. | | | | 7) THE SITE AND LANDSCAPE PLANS DO NOT MATCH. PLEASE | | ENSURE ALL PLANS ARE CONSISTENT. THE LANDSCAPE PLAN | | SHOWS CURING BETWEEN THE PARKING AND LANDSCAPE AREAS; | | HOWEVER, THIS IS NOT SHOWN ON THE SITE PLAN. THE | | LANDSCAPE PLAN ALSO SHOWS A FENCE AROUND THE "DOG WALK" | | AREA; THIS IS NOT SHOWN ON THE SITE PLAN AND WILL BE | | REQUIRED TO BE SUBMITTED UNDER SEPARATE PERMIT. | | | | 8) ALL SHADE AND FLOWERING TREES INSTALLED SHALL MEET | | THE MINIMUM CRITERIA OF THE CITY'S ZLDRS....THE | | LANDSCAPE PLAN INDICATES SHADE/FLOWERING TREES WITH 4.5 | | FEET OF CLEAR TRUNK...THE ZLDRS REQUIRE A MINIMUM OF 5 | | FEET OF CLEAR TRUNK. | | | | 9) NO SHRUBS/HEDGES/TRESS SHALL BE INSTALLED BETWEEN 18 | | INCHES AND 8 FEET WITHIN THE VISIBILITY TRIANGLE. THE | | LANDSCAPE PLAN INDICATES DAHOON HOLLY AND COCOPLUM | | WITHIN THIS AREA....THE PLANS SHALL BE REVISED | | ACCORDINGLY. | | | | 10) A "BACK-OUT" AREA NEEDS TO BE PROVIDED FOR THE | | SPACE IN THE NORTHWEST CORNER OF THE PARKING LOT. AS | | DESIGNED, CARS IN THIS SPACE WOULD NOT BE ABLE TO TURN | | WHILE BACKING OUT, ALLOWING THEM TO EXIT ONTO DIXIE | | HIGHWAY. | | | | 11) THE DOOR ON THE NORTH SIDE OF THE BUILDING APPEARS | | TO CONFLICT WITH THE PARKING SPACES. CONSIDER PULLING | | THE SPACES BACK TO THE WEST AND EXPANDING THE "DOG | | WALK" AREA. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1459 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-05-14 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-05-14 |
Time |
16:35 |
Sent To |
|
|
Notes |
2009-05-14 16:51:14 | ZONING PLAN REVIEW | | | | PERMIT NO.: 09050121 | | ADDRESS: 5112 SOUTH DIXIE HIGHWAY | | CONTRACTOR/CONTACT: BRYAN ENGLERT | | TELEPHONE NO.: 561.392.0388 | | SCOPE OF REVIEW: INTERIOR ALTERATION OF EXISTING SPACE. | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) PERMIT APPLICATION INDICATES INTERIOR RENOVATION, | | WHILE PLANS SHOW EXTERIOR/SITE MODIFICATIONS. PLEASE | | ENSURE THAT THE PERMIT APPLICATION AND THE PLANS ARE | | CONSISTENT REGARDING THE SCOPE OF WORK. | | | | 2) IF THE SCOPE OF WORK IS GOING TO INCLUDE SITE | | MODIFICATIONS, PLEASE CONSIDER THE FOLLOWING | | (ADDITIONAL COMMENTS MAY BE GENERATED IF THE SCOPE IS | | AMENDED...A FULL REVIEW WAS NOT COMPLETED AS THE SCOPE | | ONLY INDICATED INTERIOR WORK): | | | | 2A) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY SHALL | | BE PROVIDED. | | | | 2B) THE SITE PLAN SHALL TO SCALE. | | | | 2C) LANDSCAPING IS SHOWN ON THE SITE PLAN....IF | | LANDSCAPING IS PROPOSED TO BE INSTALLED, LANDSCAPE | | PLANS SHALL BE PROVIDED, AND SIGNED/SEALED, BY A | | REGISTERED LANDSCAPE ARCHITECT. ALL NEW LANDSCAPING | | SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE XIV OF | | THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS | | (ZLDRS). | | | | 2D) DIMENSIONS SHALL BE PROVIDED ON THE SITE/LANDSCAPE | | PLANS SHOWING THE DIMENSIONS OF ALL | | IMPROVEMENTS/MODIFICATIONS (I.E. LANDSCAPE BUFFERS, | | TERMINAL ISLANDS, PARKING SPACES, DRIVE AISLES, | | HANDICAP WALKS, ETC.) | | | | 2E) A PARKING STALL STRIPING DETAIL SHALL BE PROVIDED | | INDICATING COMPLIANCE WITH THE CITY'S ZLDRS. | | | | 2F) A SITE DATA TABLE SHALL BE PROVIDED SHOWING TOTAL | | ACRES OF THE PROJECT; TOTAL GROSS BUILDING SQUARE | | FOOTAGE; PERCENTAGE OF OPEN SPACE, LANDSCAPING, | | BUILDING COVERAGE, AND IMPERMEABLE SURFACE; DENSITY; | | PARKING CALCULATIONS; FAR; ETC. | | | | 3) THE SITE PLAN SHOWS STORAGE OF A RECREATIONAL | | VEHICLE. PURSUANT TO SECTION 94-444(C) OF THE CITY'S | | ZLDRS, OUTDOOR STORAGE SHALL NOT BE PERMITTED UNLESS | | CODE-REQUIRED SCREENING IS INSTALLED. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1459 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|