Plan Review Stops For Permit 09040659 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-25 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-25 |
Time |
09:19 |
Sent To |
|
|
Notes |
2009-06-25 09:21:13 | REVISION TO CHANGE ASPHALT SINGLE MANUFACTURER'S IS OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-06-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-08 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-08 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-05-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-05-19 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-19 |
Time |
08:43 |
Sent To |
|
|
Notes |
2009-05-19 09:58:23 | DENIED BY BUILDING | | | | 1) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE | | ENERGY CALCULATION FORM. FBC 13-103.1.2 | | | | 2) THE ENERGY CALCULATIONS DO NOT LIST THE INSULATION | | FOR THE SECOND FLOOR WOOD FRAME WALLS. PLEASE REVISE | | PLANS OR CALCULATIONS TO CORRESPOND. FBC 13-600 | | | | 3) SPECIFY THE MANUFACTURER AND TRUSS ANCHOR FOR THE | | ADDITIONAL STRAPPING ON THE PLANS. R802.1.6.5 | | | | 4) SHOW COMPLIANCE WITH R803.2.3.1 SHEATHING | | FASTENINGS. WOOD STRUCTURAL PANEL SHEATHING SHALL BE | | FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6 | | INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT | | INTERMEDIATE FRAMING. WHERE ROOF FRAMING WITH A | | SPECIFIC GRAVITY, 0.42< G < 0.49 IS USED, SPACING OF | | RING-SHANK FASTENERS SHALL BE 4 INCHES ON CENTER IN | | NAILING ZONE 3 FOR 130 MPH OR GREATER DESIGN WIND | | SPEEDS IN ACCORDANCE WITH FIGURE R803.2.3.1. | | | | 5) THE AGGREGATE AREA OF REPLACED GLAZING EXCEEDS 25 | | PERCENT OF THE TOTAL AREA OF GLAZED OPENINGS IN THE | | DWELLING. SHOW COMPLIANCE WITH FBC EB 606.4 REPLACEMENT | | OF WINDOWS AND DOORS. THE REPLACEMENT OF GARAGE DOORS, | | EXTERIOR DOORS, SKYLIGHTS, OPERATIVE AND INOPERATIVE | | WINDOWS SHALL BE DESIGNED AND CONSTRUCTED TO COMPLY | | WITH CHAPTER 16 OF THE FLORIDA BUILDING CODE, BUILDING | | . | | EXCEPTIONS: | | 1. OPENING PROTECTION EXCEPTION: FOR ONE- AND | | TWO-FAMILY DWELLINGS CONSTRUCTED UNDER CODES OTHER THAN | | THE FLORIDA BUILDING CODE AND LOCATED IN WIND-BORNE | | DEBRIS REGIONS, THE REPLACEMENT OF GARAGE DOORS AND | | EXTERIOR DOORS WITH GLAZING, SLIDING GLASS DOORS, GLASS | | PATIO DOORS, SKYLIGHTS AND OPERABLE AND INOPERABLE | | WINDOWS WITHIN ANY 12-MONTH PERIOD SHALL NOT BE | | REQUIRED TO HAVE OPENING PROTECTION BUT SHALL BE | | DESIGNED FOR WIND PRESSURES FOR ENCLOSED BUILDINGS, | | PROVIDED THE AGGREGATE AREA OF THE GLAZING IN THE | | REPLACED COMPONENTS DOES NOT EXCEED 25 PERCENT OF THE | | AGGREGATE AREA OF THE GLAZED OPENINGS IN THE DWELLING | | OR DWELLING UNIT. SUBMIT TWO COPIES OF PRODUCT | | APPROVALS AND INSTALLATION SCHEDULES FOR THE STORM | | PANELS. SEE SAMPLE SCHEDULE ATTACHED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-07-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-07-07 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-07-07 |
Time |
09:57 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-06-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-06-08 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-06-08 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-05-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-08 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-08 |
Time |
13:38 |
Sent To |
|
|
Notes |
2009-05-08 15:45:18 | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} TWO SETS OF ELECTRICAL PLANS WERE SUBMITTED FOR | | REVIEW, ONE MARKED EXISTING WIRING, BUT WAS SIGNED AND | | SEALED, THE OTHER HAD NO SIGNATURE OR NAME OF THE | | DESIGNER, AND DID NOT MATCH THE "EXISTING" DEVICE | | LOCATIONS ON THE SEALED SET. THE ADDRESS WAS NOT ON THE | | 8 1/2" X 11" SET. INDICATE WHICH DEVISES ARE TO BE | | INSTALLED/ADDED AND WHICH ARE EXISTING. ALSO NOTE THE | | PANEL LOCATIONS ARE DIFFERENT ON THE TWO PLANS. | | INDICATE IF THE SERVICE IS NEW OR EXISTING. 215.5 NEC, | | 106.1.3 FBC AS AMENDED | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-06-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-06-24 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-06-24 |
Time |
14:32 |
Sent To |
|
|
Notes |
2009-06-24 14:32:24 | TO BT DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-05-27 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-05-27 |
Time |
16:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-05-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-05-19 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-01 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2009-06-09 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2009-06-09 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2009-06-09 |
Time |
13:33 |
Sent To |
|
|
Notes |
2009-06-09 13:35:23 | ***LANDSCAPE APPROVED WITH PROVISO*** | | | | PROVIDE SOD AND IRRIGATION IN RIGHT-OF-WAY. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | KUSSNER @ (561) 822-1462. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-07-27 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-07-27 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-07-27 |
Time |
09:50 |
Sent To |
PC |
|
Notes |
2009-07-27 09:50:41 | REVISED 1ST FL DUCT PLAN |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-05-11 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-05-11 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-05-11 |
Time |
11:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2009-06-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-06-08 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-06-08 |
Time |
10:38 |
Sent To |
|
|
Notes |
2009-06-08 10:43:01 | PER GENERAL CONTRACTOR THE PLUMBING CONTRACTOR WILL BE | | REMOVING FIXTURES & WATER HEATER AND RESETTING THEM IN | | THE SAME LOCATIONS WITH NO CHANGES TO SANITARY OR WATER | | SYSTEMS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2009-05-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-08 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-08 |
Time |
09:15 |
Sent To |
|
|
Notes |
2009-05-08 09:18:16 | | | | | PER GENERAL CONTRACTOR THE PLUMBING CONTRACTOR WILL BE | | REMOVING FIXTURES & WATER HEATER AND RESETTING THEM IN | | THE SAME LOCATION WITH NO CHANGES TO SANITARY OR WATER | | SYSTEM. | | | | | | | | | | | | | | . |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-06-09 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-06-09 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-06-09 |
Time |
17:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-05-19 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-05-19 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-05-19 |
Time |
15:43 |
Sent To |
|
|
Notes |
2009-05-19 15:47:16 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | 2. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK | | EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS | | "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | THE ZLDR. | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | THE ZLDR. | | | | 3. IS THERE GOING TO BE AN INCREASE IN SQUARE FOOTAGE | | OF THE HOUSE? IS YES, PROVIDE TWO (2) COPIES OF A | | CURRENT SURVEY, WHICH INCLUDES THE PROPERTY'S ADDRESS | | AND LEGAL DESCRIPTION. INDICATE THE SETBACK DIMENSION | | OF THE PROPOSED ADDITION (IF APPLICABLE) TO ALL | | ADJACENT PROPERTY LINES. | | | | 4. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED ADDITION ON | | THE ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION | | 94-611, THE HEIGHT SHALL BE MEASURED AS THE VERTICAL | | DISTANCE FROM THE AVERAGE ELEVATION OF THE FINISHED | | GRADE OF THE BUILDING TO THE MEAN HEIGHT LEVEL BETWEEN | | EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | GENERATE ADDITIONAL COMMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1444 OR (561) 805-6720 | | E-MAIL: [email protected] | | |
|
|