Plan Review Details - Permit 09040559
Plan Review Stops For Permit 09040559
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-10-14 Cont ID  
Sent By shill Date 2009-10-14 Time 11:50 Rev Time 0.00
Received By shill Date 2009-10-14 Time 11:50 Sent To  
Notes
2009-10-14 11:50:39REVISED INSTALLATION SCHEDULE OK
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-09-09 Cont ID  
Sent By shill Date 2009-09-09 Time 13:54 Rev Time 0.00
Received By shill Date 2009-09-09 Time 13:54 Sent To  
Notes
2009-09-09 14:02:17****CORRECTIONS****
 ****REVISION, DESIGN PRESSURES PREPARED BY TARNOWSKI
 ENGINEERING***
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 FROM PREVIOUS REVIEWS:
  
 1. FLOOR MOUNTS H AND I REQUIRE 3000PSI CONCRETE, SEE
 SHEETS 14, 15. INSTALLATION SCHEDULE NOTES THIS AS
 BLOCK.
  
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS.
  
 NEW:
  
 IT IS NOT CLEAR WHY NEW DESIGN PRESSURES WERE
 SUBMITTED; THIS DOES NOT ADDRESS THE COMMENT. FLOOR
 MOUNTS H AND I BOTH REQUIRE 3000 PSI CONCRETE. THE
 INSTALLATION SCHEDULE SUBMITTED BY THE CONTRACTOR
 STATES THAT THE SUBSTRATE IS BLOCK. EVEN IF THE
 SUBSTRATE IS CONCRETE, RESIDENTIAL PATIO SLABS ARE
 USUALLY 2500 PSI. PLEASE DEMONSTRATE HOW THE ANCHOR
 SPACING PROPOSED WILL COMPLY WITH DESIGN PRESSURE
 REQUIREMENTS.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-16 Cont ID  
Sent By shill Date 2009-07-16 Time 18:47 Rev Time 0.00
Received By shill Date 2009-07-16 Time 18:47 Sent To  
Notes
2009-07-16 18:48:53***PROVISO***
 ***REVISION REQUIRED BEFORE FIRST INSPECTION***
  
 CONCRETE STRENGTH 3000PSI REQUIRED (NOT ADDRESSED IN
 RESUB)
  
 TWO ORIGINAL SETS OF ENGINEERING REQUIRED
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-29 Cont ID  
Sent By shill Date 2009-04-29 Time 08:49 Rev Time  
Received By shill Date 2009-04-28 Time 16:52 Sent To  
Notes
2009-04-29 08:51:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. FLOOR MOUNTS H AND I REQUIRE 3000PSI CONCRETE, SEE
 SHEETS 14, 15. INSTALLATION SCHEDULE NOTES THIS AS
 BLOCK.
  
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-10-13 Cont ID  
Sent By shill Date 2009-10-13 Time 10:05 Rev Time 0.00
Received By shill Date 2009-10-13 Time 10:05 Sent To  
Notes
2009-10-13 10:06:06TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-09-09 Cont ID  
Sent By shill Date 2009-09-09 Time 14:03 Rev Time 0.00
Received By shill Date 2009-09-09 Time 14:03 Sent To  
Notes
2009-09-09 14:03:40TO SMH DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-09 Cont ID  
Sent By jgomez Date 2009-07-09 Time 14:24 Rev Time 0.00
Received By jgomez Date 2009-07-09 Time 14:24 Sent To  
Notes
2009-07-09 14:24:39SENT TO SAMANTA'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-29 Cont ID  
Sent By shill Date 2009-04-29 Time 08:51 Rev Time 0.00
Received By shill Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved