Plan Review Details - Permit 09040409
Plan Review Stops For Permit 09040409
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-06-09 Cont ID  
Sent By shill Date 2009-06-09 Time 10:03 Rev Time 0.00
Received By shill Date 2009-06-09 Time 10:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-05-19 Cont ID  
Sent By shill Date 2009-05-19 Time 12:17 Rev Time 0.00
Received By shill Date 2009-05-19 Time 12:17 Sent To  
Notes
2009-05-19 12:31:04****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1. ADDRESSED.
  
 2. PLEASE PROVIDE CERTIFICATION FOR THE BUILDING
 HEIGHT. YOU AHVE DECLARED A BUILDING HEIGHT OF 96 FEET;
 PAPA SHOWS THIS TO BE A 20+STORY BUILDING. OTHER
 CONTRACTORS STATE THAT THIS IS A 200' BUILDING.
  
 2ND REVIEW, ENGINEERING STATES THAT THIS BUIDLING IS
 134' BUT ALSO STATES THAT ENGINEER HAS NOT VISITED THIS
 SITE. PLEASE PROVIDE EVIDENCE TO JUSTIFY THE DECLARED
 BUILDING HEIGHT OF 134' AS THAT CONFLICTS WITH OUR
 RECORDS.
  
 ALSO, PLEASE HAVE ENGINEER PROVIDE INFORMATION
 REGARDING HOW "ENCLOSED" CLASSIFICATION WAS DETERMINED
 AS IT DOES NOT APPEAR THAT ALL UNITS IN THIS BUILDING
 HAVE FBC COMPLIANT IMPACT PROTECTION.
  
 3. PLEASE COMPLETE THE INSTALLATION SCHEDULE. ANCHOR
 SPACING HAD "NOA" WRITTEN IN THAT COLUMN. THIS SHOULD
 BE THE ANCHOR SPACING IN INCHES PROPOSED. IT APPEARS
 THAT YOU PROPOSE 3.8".
  
 ADDRESSED, BUT DESIGN PRESSURE ON THE INSTALLATION
 SCHEDULE DOES NOT MATCH ENGINEERING; PLEASE REVISE.
 BEFORE RESUBMITTING, PLEASE CONFIRM THAT ALL
 INFORMATION IS CORRECT AS PROPOSED INSTALLATION MAY BE
 AFFECTED IF DESIGN PRESSURES ARE CHANGED DUE TO COMMENT
 #2.
  
 4. PLEASE COMPLETE THE COLUMN "SHUTTER MOUNTING
 CONNECTION TYPE." IT APPEARS THAT YOU PROPOSE TO USE
 AA.
  
 5. IF AA IS USED, TAPCON, MINIMUM EDGE DISTANCE
 IREQUIRED IS 3 1/8". PLEASE REVISE INSTALLATION
 SCHEDULE (2" PROPOSED; DOES NOT COMPLY WITH PRODUCT
 APPROVAL).
  
 6. ADDRESSED.
  
 NEW COMMENT:
  
 THE SPECIALTY LICENSE NUMBER PROVIDED IS FOR SHUTTERS
 ONLY. FOR THE WINDOW INSTALLATION, PLEASE PROVIDE
 EITHER:
  
 A SEPARATE APPLICATION WITH THE APPROPRIATE
 LICENSE/QUALIFIER SIGNATURE, OR
  
 SIGN UNDER "BUILDING CONTRACTOR" (BOTTOM OF PERMIT
 APPLICATION) INCLUDING LICENSE NUMBER INFORMATION.
  
 A SEPARATE PERMIT NUMBER WILL BE ASSIGNED FOR THE
 WINDOWS. PLEASE BE SURE TO FINAL OUT BOTH PERMITS.
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-21 Cont ID  
Sent By shill Date 2009-04-21 Time 14:11 Rev Time 0.00
Received By shill Date 2009-04-21 Time 14:11 Sent To  
Notes
2009-04-21 14:12:35****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PROVIDE ENGINEERING TO JUSTIFY PROPOSED DESIGN
 PRESSURES, FBC 1609. (+30S/-50S).
  
 2. PLEASE PROVIDE CERTIFICATION FOR THE BUILDING
 HEIGHT. YOU AHVE DECLARED A BUILDING HEIGHT OF 96 FEET;
 PAPA SHOWS THIS TO BE A 20+STORY BUILDING. OTHER
 CONTRACTORS STATE THAT THIS IS A 200' BUILDING.
  
 3. PLEASE COMPLETE THE INSTALLATION SCHEDULE. ANCHOR
 SPACING HAD "NOA" WRITTEN IN THAT COLUMN. THIS SHOULD
 BE THE ANCHOR SPACING IN INCHES PROPOSED. IT APPEARS
 THAT YOU PROPOSE 3.8".
  
 4. PLEASE COMPLETE THE COLUMN "SHUTTER MOUNTING
 CONNECTION TYPE." IT APPEARS THAT YOU PROPOSE TO USE
 AA.
  
 5. IF AA IS USED, TAPCON, MINIMUM EDGE DISTANCE
 IREQUIRED IS 3 1/8". PLEASE REVISE INSTALLATION
 SCHEDULE (2" PROPOSED; DOES NOT COMPLY WITH PRODUCT
 APPROVAL).
  
 6. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED,
 FAC9B72. THE PRODUCT APPROVAL FOR ROLLER STAR IS
 "VALIDATED," SHOULD SAY "APPROVED."
 WWW.FLORIDABUILDING.ORG
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-05-18 Cont ID  
Sent By rmcdouga Date 2009-05-18 Time 16:27 Rev Time 0.00
Received By rmcdouga Date 2009-05-18 Time 16:27 Sent To  
Notes
2009-05-18 16:27:41TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-21 Cont ID  
Sent By shill Date 2009-04-21 Time 14:25 Rev Time 0.00
Received By shill Date 2009-04-21 Time 14:25 Sent To  
Notes
***NONE***