Plan Review Details - Permit 09040336
Plan Review Stops For Permit 09040336
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2009-07-31 Cont ID  
Sent By jwitmer Date 2009-07-31 Time 09:30 Rev Time 0.50
Received By jwitmer Date 2009-07-31 Time 09:30 Sent To  
Notes
2009-07-31 09:31:00CAROUSEL CEILING MATERIAL FLAME SPREAD/ SMOKE DEV
 SHEETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-07-14 Cont ID  
Sent By jwitmer Date 2009-07-14 Time 13:41 Rev Time 0.77
Received By jwitmer Date 2009-07-14 Time 13:41 Sent To  
Notes
2009-07-14 13:42:56REVISION# 1 STRUCTURAL SHEET THOMAS TOWMEY P. E. DATED
 6/30/09

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-06-03 Cont ID  
Sent By jwitmer Date 2009-06-03 Time 08:30 Rev Time 0.50
Received By jwitmer Date 2009-06-03 Time 08:00 Sent To  
Notes
2009-06-03 08:31:52BUILDING PLAN REVIEW
 PERMIT: 09040336
 ADD: 700 S ROSEMARY# 208
 CONT: SISCA
 TEL: (561)248-9041
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 JUNE 03/2009
 3RD REVIEW
 ACTION: REVIEWED
  
 1) THIS BUILDING IS A 5 STORY BUILDING (PARKING GARAGE
 PORTION) WHICH ENACTS THE FLORIDA STATE THRESHOLD LAWS:
 BUILDING CLASSIFICATION AS A BUILDING TYPE: I-B/ A2
 OCCUPANCY
  
 THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
  
 1B) THRESHOLD INSPECTOR:
 WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES
 DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL
 INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA
 STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS
 CODE.
 CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR
 PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION
 BEFORE THE PERMIT MAY BE ISSUED.
  
 1C) THRESHOLD BLDG, REQUIRED STATEMENT:
 W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE.
  
  
 BUILDING PLAN REVIEW
 PERMIT: 09040336
 ADD: 700 S ROSEMARY# 208
 CONT: SISCA
 TEL: (561)248-9041
  
 BUILDING PROVISO:
 THESE FINISH MATERIAL REQUIREMENTS MUST BE MET BEFORE A
 CERTIFICATE OF COMPLETION CAN BE ISSUED.
  
 1) 803.6 TEXTILES. WHERE USED AS INTERIOR WALL OR
 CEILING FINISH MATERIALS, TEXTILES, INCLUDING MATERIALS
 HAVING WOVEN OR NONWOVEN, NAPPED, TUFTED, LOOPED OR
 SIMILAR SURFACE AND CARPET AND SIMILAR TEXTILE
 MATERIALS, SHALL COMPLY WITH THE REQUIREMENTS OF
 SECTION 803.6.1, 803.6.2 OR 803.6.3.
  
 803.6.1 SURFACE BURNING CHARACTERISTIC TEST. TEXTILE
 WALL AND CEILING COVERINGS SHALL HAVE A CLASS A FLAME
 SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE
 PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN
 ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2.
  
 803.6.2 ROOM CORNER TEST, TEXTILES. TEXTILE WALL
 COVERINGS SHALL MEET THE CRITERIA OF SECTION 803.6.2.1
 WHEN TESTED IN THE MANNER INTENDED FOR USE IN
 ACCORDANCE WITH THE METHOD B PROTOCOL OF NFPA 265 USING
 THE PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE.
  
 803.6.2.1 METHOD B TEST PROTOCOL. DURING THE 40 KW
 EXPOSURE, THE INTERIOR FINISH SHALL COMPLY WITH ITEM 1.
 DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH SHALL
 COMPLY WITH ITEM 2. DURING THE ENTIRE TEST, THE
 INTERIOR FINISH SHALL COMPLY WITH ITEM 3.
  
 1. DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD
 TO THE CEILING.
  
 2. DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH
 SHALL COMPLY WITH THE FOLLOWING:
  
 2.1. FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITIES OF
 THE SAMPLES ON THE 8-FOOT BY 12-FOOT (203 MM BY 305 MM)
 WALLS.
  
 2.2. FLASHOVER, AS DESCRIBED IN NFPA 265, SHALL NOT
 OCCUR.
  
 3. THE TOTAL SMOKE RELEASED THROUGHOUT THE NFPA 265
 TEST SHALL NOT EXCEED 1000 M2.
  
 803.6.3 ROOM CORNER TEST, CEILING AND WALL FINISH.
 TEXTILE WALL AND CEILING COVERINGS SHALL MEET THE
 CRITERIA OF SECTION 803.2.1 WHEN TESTED IN THE MANNER
 INTENDED FOR USE IN ACCORDANCE WITH NFPA 286 USING THE
 PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE.
  
 2) FIBERGLASS LIGHT PANELS:
 2611.1 GENERAL. LIGHT-TRANSMITTING PLASTIC INTERIOR
 WALL SIGNS SHALL BE LIMITED AS SPECIFIED IN SECTIONS
 2611.2 THROUGH 2611.4. LIGHT-TRANSMITTING PLASTIC
 INTERIOR SIGNS SHALL ALSO COMPLY WITH SECTION 2606.
  
 2611.2 AGGREGATE AREA. THE SIGN SHALL NOT EXCEED 20
 PERCENT OF THE WALL AREA.
  
 2611.3 MAXIMUM AREA. THE SIGN SHALL NOT EXCEED 24
 SQUARE FEET (2.23 M2).
  
 2611.4 ENCASEMENT. EDGES AND BACKS OF THE SIGN SHALL BE
 FULLY ENCASED IN METAL.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-05-14 Cont ID  
Sent By jwitmer Date 2009-05-14 Time 09:40 Rev Time 1.60
Received By jwitmer Date 2009-05-14 Time 08:00 Sent To  
Notes
2009-05-14 08:46:47BUILDING PLAN REVIEW
 PERMIT: 09040336
 ADD: 700 S ROSEMARY# 208
 CONT: SISCA
 TEL: (561)248-9041
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1) THIS BUILDING IS A 5 STORY BUILDING (PARKING GARAGE
 PORTION) WHICH ENACTS THE FLORIDA STATE THRESHOLD LAWS:
 BUILDING CLASSIFICATION AS A BUILDING TYPE: I-B/ A2
 OCCUPANCY
  
 THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
 1A)109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A
 SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON
 A THRESHOLD BUILDING PURSUANT TO A STRUCTURAL
 INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE
 STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE
 ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING
 PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING.
 THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO
 PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO
 THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR
 COMPLIANCE WITH THE PERMITTED DOCUMENTS.
  
 1B) THRESHOLD INSPECTOR:
 WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES
 DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL
 INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA
 STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS
 CODE.
 CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR
 PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION
 BEFORE THE PERMIT MAY BE ISSUED.
  
 1C) THRESHOLD BLDG, REQUIRED STATEMENT:
 W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE.
  
  
 BUILDING PROVISO:
  
 1) 803.6 TEXTILES. WHERE USED AS INTERIOR WALL OR
 CEILING FINISH MATERIALS, TEXTILES, INCLUDING MATERIALS
 HAVING WOVEN OR NONWOVEN, NAPPED, TUFTED, LOOPED OR
 SIMILAR SURFACE AND CARPET AND SIMILAR TEXTILE
 MATERIALS, SHALL COMPLY WITH THE REQUIREMENTS OF
 SECTION 803.6.1, 803.6.2 OR 803.6.3.
  
 803.6.1 SURFACE BURNING CHARACTERISTIC TEST. TEXTILE
 WALL AND CEILING COVERINGS SHALL HAVE A CLASS A FLAME
 SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE
 PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN
 ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2.
  
 803.6.2 ROOM CORNER TEST, TEXTILES. TEXTILE WALL
 COVERINGS SHALL MEET THE CRITERIA OF SECTION 803.6.2.1
 WHEN TESTED IN THE MANNER INTENDED FOR USE IN
 ACCORDANCE WITH THE METHOD B PROTOCOL OF NFPA 265 USING
 THE PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE.
  
 803.6.2.1 METHOD B TEST PROTOCOL. DURING THE 40 KW
 EXPOSURE, THE INTERIOR FINISH SHALL COMPLY WITH ITEM 1.
 DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH SHALL
 COMPLY WITH ITEM 2. DURING THE ENTIRE TEST, THE
 INTERIOR FINISH SHALL COMPLY WITH ITEM 3.
  
 1. DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD
 TO THE CEILING.
  
 2. DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH
 SHALL COMPLY WITH THE FOLLOWING:
  
 2.1. FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITIES OF
 THE SAMPLES ON THE 8-FOOT BY 12-FOOT (203 MM BY 305 MM)
 WALLS.
  
 2.2. FLASHOVER, AS DESCRIBED IN NFPA 265, SHALL NOT
 OCCUR.
  
 3. THE TOTAL SMOKE RELEASED THROUGHOUT THE NFPA 265
 TEST SHALL NOT EXCEED 1000 M2.
  
 803.6.3 ROOM CORNER TEST, CEILING AND WALL FINISH.
 TEXTILE WALL AND CEILING COVERINGS SHALL MEET THE
 CRITERIA OF SECTION 803.2.1 WHEN TESTED IN THE MANNER
 INTENDED FOR USE IN ACCORDANCE WITH NFPA 286 USING THE
 PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE.
  
 2) FIBERGLASS LIGHT PANELS:
 2611.1 GENERAL. LIGHT-TRANSMITTING PLASTIC INTERIOR
 WALL SIGNS SHALL BE LIMITED AS SPECIFIED IN SECTIONS
 2611.2 THROUGH 2611.4. LIGHT-TRANSMITTING PLASTIC
 INTERIOR SIGNS SHALL ALSO COMPLY WITH SECTION 2606.
  
 2611.2 AGGREGATE AREA. THE SIGN SHALL NOT EXCEED 20
 PERCENT OF THE WALL AREA.
  
 2611.3 MAXIMUM AREA. THE SIGN SHALL NOT EXCEED 24
 SQUARE FEET (2.23 M2).
  
 2611.4 ENCASEMENT. EDGES AND BACKS OF THE SIGN SHALL BE
 FULLY ENCASED IN METAL.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-04-18 Cont ID  
Sent By mjacobs Date 2009-04-18 Time 10:04 Rev Time 0.00
Received By mjacobs Date 2009-04-18 Time 08:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2009-10-08 Cont ID  
Sent By dpalmer Date 2009-10-08 Time 18:25 Rev Time 0.00
Received By dpalmer Date 2009-10-08 Time 18:25 Sent To PC
Notes
2009-10-08 18:27:02PLANS DID NOT CONTAIN CITY PLACE STAMP. NOT FBC OR NEC
 REQUIREMENT.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-06-03 Cont ID  
Sent By dpalmer Date 2009-05-29 Time 13:20 Rev Time 0.00
Received By dpalmer Date 2009-05-29 Time 13:20 Sent To  
Notes
2009-05-29 13:24:47** TEMP FAILED STATUS AS NEW SHEETS DO NOT CONTAIN ANY
 STAMPS FROM CITY PLACE MANAGMENT. THIS IS A CITY PLACE
 REQUIREMENT, NOT CITY OF WEST PALM BEACH. IF NO STAMP
 IS REQUIRED FROM CITY PLACE MANAGMENT OFFICE, PLEASE
 OBTAIN IN WRITING AND REVIEW WILL BE CHANGED TO A *P*
 STATUS. IF STAMP IS STILL REQUIRED THEN PLEASE HAVE
 PLANS STAMPED OR REPRESENTIVE FROM CITY PLACE OFFICE
 MAY COME IN AND STAMP AND SIGNS SHEETS.
 PLEASE CONTACT THIS OFFICE AS SOON AS POSSIBLE.
2009-05-29 13:21:42*** NOTES/ REDLINES/ PROVISO ****
  
 1) NOTE: THE CAROUSEL LIGHTING PANELS AS SHOWN ON PLANS
 SHALL BE FULLY LISTED AS A SIGN. 110.3, 13-415.AB.5,
 THE LISTING SHALL BE PER A NRTL/ SIGN LIGHTING
 MANUFACTURE IN ORDER TO MEET EXEMPTION FROM WATTAGE
 INPUT FOR FBC SECTION NOTED.
 EACH SIGN SHALL BE LISTED INDIVIDUALLY. MAY NOT BE A
 *TYPICAL* LISTING FOR ALL.
 ALL DOCUMENTS SHOWING LISTING ETC SHALL BE SUBMITTED TO
 THIS OFFICE FOR REVIEW PRIOR TO FINAL AND INSTALLATION.
 THIS WAS THE AGREEMENT WITH PLANS EXAMINER AND BUILDING
 OFFICIAL.
  
 2) NOTE: RISER SHOWS WHAT APPEARS TO BE A NEUTRAL FROM
 H PANEL TO TRANSFORMER. TRANSFORMER IS SEPARATELY
 DERIVED. ONLY PHASE CONDUCTORS AND EQUIPMENT GROUND IS
 INSTALLED. 250.6, 250.20,250.30
  
 3) NOTE: ALL FA DEVICES SHALL MEET FBC ADA,
 11-4.28.1-.4
  
 4) NOTE: ALL LOW VOLTAGE SYSTEMS SHALL BE UNDER
 SEPARATE PERMITS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2009-05-08 Cont ID  
Sent By dpalmer Date 2009-05-08 Time 15:28 Rev Time 0.00
Received By dpalmer Date 2009-05-08 Time 15:29 Sent To  
Notes
2009-05-08 15:29:07**DENIED PLANS**
  
  
  
 1) NOTE: COMPLIANCE WITH FBC 13-415.AB.5 CAN NOT BE
 DETERMINED.
 SOME LIGHTING ON PLANS IS STILL NOT COMPLETE.
 FOR EXAMPLE: PLEASE SEE ELEVATED DINING AREA WHICH
 LIGHTING PLANS SHOW SOME OF THE *D* FIXTURES TO LCP YET
 ON THE POWER PLANS THERE ARE *D* FIXTURES ARE NOT IN
 THE SAME LOCATION AND ARE NOT SHOWN CIRCUITED OR
 CONTROLLED BY LCP OR OTHER TYPE OF DEVICES.
 FOR EXAMPLE: PLEASE SEE G-1 FIXTURES WHICH BASED ON THE
 FIXTURE SYMBOLS AND NOTES ARE NOT DETERMINED AS ANY
 TYPE OF FIXTURE.
 FOR EXAMPLE: KITCHEN AREA LIGHTS CONTAIN NOTES ON PLANS
 WHICH MENTIONS TO CIRCUIT TO LCP HOWEVER THE PLANS DO
 NOT INDICATE ANY NEW OVER RIDES PER 13-415.AC.1.1,
 .1.2.
  
 2) NOTE: PLEASE SEE 700.12F FOR CIRCUITING IF EMERGENCY
 AND EXIT LIGHTS. THERE ARE NUMEROUS NEW FIXTURES WHICH
 DO NOT SHOW ANY TYPE OF CIRCUITING. THERE ARE SOME
 FIXTURES WHICH ARE NOT CIRCUITED TO THE LOCAL LIGHTING
 IN ANY ONE AREA. SEE SAME FOR EXIT SIGNS.
 SEE FIRE MARSHAL REVIEW COMMENTS FOR REQUIRED EXIT
 SIGNS. (UPPER BAR AREA) SEE NFPA-101 7.8, 7.9 SOME ARE
 MISSING.
  
 3) NOTE: PLEASE SEE ELECTRICAL RISER. THE RISER NEEDS
 TO BE COORDINATE WITH WHAT IS SHOWN ON RISER WITH
 PANELS. THERE ARE ALSO NEW CIRCUITS BEING ADDED TO
 PANELS SUCH AS PA WHICH THE PANEL SCHEDULE HAS NOT BEEN
 SUBMITTED. IN THE CONVERSATION WITH ELECTRICAL DESIGNER
 THE COMMENT WAS ONLY MADE TO THE EXISTING PANELS IN
 WHICH NO WORK WAS BEING DONE COULD BE DONE AS A
 PROVISO. HOWEVER THE PANELS IN WHICH THE PREDOMINANT
 AMOUNT OF WORK IS BEING DONE NEED TO COORDINATE WITH
 PLANS AND RISER.
 FOR EXAMPLE: PLEASE SEE RISER, ALL PANELS WITH THE
 EXCEPTION OF KA SECTION TWO ARE BEING FED FROM KA
 SECTION #1. HOWEVER BASED ON THE PANEL SCHEDULES FOR KA
 SECTION #1, THERE ARE NO PANELS LISTED.
 PLEASE COORDINATE.
  
 4) NOTE: PLEASE SEE MULTIPLE RECEPTACLES WITH NO
 CIRCUITING. SOME HAVE NOTES CLOSE TO THE DEVICE AND
 SOME ARE MISSING CIRCUITS.
 408.4, 240.4, 310.16, 220.14, 220.44
  
 5) NOTE: PANEL IN DEDICATE ELECTRICAL CLOSET STILL
 SHOWN ENCROACHING ON THE CLEAR SPACE REQUIRED PER
 110.26
  
 6) NOTE: PLEASE PROVIDE WHERE THE TRANSFORMER IS
 LOCATED IN THE ROOM SHOWN ON PLANS. IS THIS ON FLOOR?
 PLEASE SEE 450.13, 110.26, 450.9, 450.21B ETC.
  
  
 ** ANY AND ALL LOW VOLTAGE SHALL BE UNDER SEPARATE
 PERMITS, FEES AND PLANS.
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-04-17 Cont ID  
Sent By dpalmer Date 2009-04-17 Time 18:42 Rev Time 0.00
Received By dpalmer Date 2009-04-17 Time 18:42 Sent To  
Notes
2009-04-17 18:42:41** DENIED **
  
  
  
 1) NOTE: PLANS NEED TO BE UNDER THE 2006 NFPA101. ALL
 PLANS SUBMITTED AFTER DECEMBER 31ST 2008
 FAC 69A-60.003, .004
 PLANS REVIEWED UNDER NFPA-101 2006, NFPA-70 2005 AND
 2007 FBC WITH 2009 REVISIONS.
  
 2) NOTE: PLEASE COMPLETE PLANS FOR ALL LIGHTING AND
 LIGHTING PERFORMANCE CALCULATIONS PER FBC 13-415.AB.5.
 PLANS MAKE REFERENCE TO 13-415.2.C.1, HOWEVER THAT CODE
 NO LONGER EXISTS IN THE CODE.
 PLEASE PROVIDE INFORMATION ON ALL LIGHTING FIXTURES
 SPECIFIC TO MANUFACTURE AND RATING OF FIXTURES.
 ALL FIXTURES SHALL BE INCLUDED IN THE CALCULATIONS
 UNLESS MEETING EXCEPTIONS. IF LIGHTING MEETS
 EXCEPTIONS, PLEASE IDENTIFY AND PROVIDE WHAT WILL MAKE
 THEM EXISTING.
 AS THERE IS MISSING INFORMATION A COMPLETE REVIEW CAN
 NOT BE DONE AT THIS TIME.
  
 ** PLEASE BE SURE ALL LIGHTING AS NOTED AND SHOWN
 CONTAINS A LISTING FROM A NATIONALLY RECOGNIZED TESTING
 LABORATORY. ( NRTL). 110.3
  
 3) NOTE: PLEASE SHOW COMPLIANCE WITH FBC 11-4.28.1,.2
 AND .3 FOR ADA COMPLIANCE.
  
 4) NOTE: PLEASE SUBMIT COMPLETE LOADS ON ALL PANELS.
 BELOW PANELS THERE ARE NOTES WHICH STATE ONLY NEW
 CIRCUITS ARE SHOWN. HOWEVER WITH THIS SAME STATEMENT
 THIS MEANS ONLY NEW LOADS ARE SHOWN AS NO OTHER LOADS
 ARE SHOWN.
 220.12,220.14,220.42, 220.43, 220.44 ETC
 PLEASE SEE 215.3, 230.42 FOR CONTINUOUS LOADS.
 ** PLEASE KEEP IN MIND THE SHOW WINDOW LOADS.
  
 5) NOTE: PLEASE COORDINATE ALL PANELS AND RISER
 DIAGRAM. PLEASE BE SURE TO COORDINATE WITH NOTES ABOVE
 FOR LOAD CALCULATIONS ALSO.
 THIS NOTE WILL BE BROKEN DOWN INTO MULTIPLE SECTIONS AS
 THERE ARE SEVERAL COORDINATION ITEMS WHICH NEED TO BE
 ADDRESSED.
  
 A) PLEASE SEE RISER AS PANEL *L* IS SHOW BEING FED FROM
 PANEL *KA SECTION 1* HOWEVER PER THE PANEL SCHEDULE
 SUBMITTED FOR THIS PANEL, NO PANEL *L* IS FED FROM THIS
 PANEL. PANEL *KA SECTION 2* ALSO DOES NOT LIST PANEL
 *L*.
  
 B) PLEASE SEE RISER AS PANEL *R* IS SHOWN BEING FED
 FROM *KA SECTION 1* HOWEVER BASED ON PANEL SCHEDULES OF
 BOTH SECTION ONE AND TWO, THE PANEL *R* IS ACTUALLY
 BEING FED FROM *KA SECTION 2*.
  
 C) PLEASE SEE RISER AS PANEL *KA SECTION * IS SHOWN
 BEING FED FROM *KA SECTION 2*. THIS SEEMS TO BE
 BACKWARDS AS THE SECTION 2 IS IN FRONT OF SECTION ONE.
 IN EITHER CASE NO MCB IS SHOWN IN SECTION ONE PANEL AND
 SECTION TWO PANEL WHICH IS SHOWN ON THE RISER AS ALL
 TAPPED CONDUCTORS SHALL TERMINATE IN OVER CURRENT
 PROTECTION. IN EITHER CASE A MAIN NEEDS TO BE
 INSTALLED. 240.21
 ALSO, WHICH PANEL IS ACTUALLY THE FIRST PANEL SECTION?
  
 D) PLEASE SEE RISER AS THERE ARE TWO LIGHTING CONTROL
 PANELS BEING SHOWN WHEN THERE IS ONLY ONE SCHEDULE
 SUBMITTED FOR ONE LIGHTING CONTROL PANEL.
  
 E) PLEASE COORDINATE ALL PANELS AND LOCATIONS OF ALL
 SERVICE EQUIPMENT. PLEASE SEE EQUIPMENT PLANS AS THE
 UNIVERSAL SYMBOL FOR AN ELECTRICAL PANEL INDICATES TWO
 PANELS WHICH ARE NOT ON ANY OTHER SHEETS. THESE ARE IN
 THE KITCHEN AREA NEAR EQUIPMENT NUMBERS 34,35.
 ARE THESE PANELS?
 WHERE IS PANEL PA?
 PLEASE SEE THE TWO LCP ON PLANS DO NOT MEET 110.26 AS
 BOTH ARE SHOWN WITH OVER LAP WHICH ONE WOULD AFFECT THE
 OTHER FOR CODE SECTION GIVEN. THESE MAY ALSO NOT BE
 LOCATED IN ANY TYPE OF STORAGE CLOSET.
 110.26, 240.24
  
  
 PLEASE GO OVER ALL PANELS, CIRCUITS, TAPPED CONDUCTORS,
 ETC. SOME ITEMS ARE NOTED FOR BENEFIT HOWEVER ARE NOT
 ALL ITEMS.
 240.21,215.5, 240.4, 310.16, 408.4, 408.36 ETC
  
 6) NOTE: ** NOTED FOR INFORMATIONAL PURPOSE. THE LOW
 VOLTAGE SYSTEMS AS SHOWN ON PLANS SUCH AS SPEAKERS,
 PHONE CATV SHALL BE REQUIRED TO BE UNDER SEPARATE
 PERMIT(S)
 THESE PLANS MAY BE REFERENCED FOR TURN AROUND PERMITS
 HOWEVER SEPARATE FEES AND PERMIT APPLICATION(S) ARE
 REQUIRED.
  
 7) NOTE: PLEASE BE SURE TO COMPLY WITH FBC
 13-415.1.AB.1.1, .1.2 AND .1.3 FOR LIGHTING CONTROLS.
 ** SEE SEPARATE CONTROLS**
 PLEASE ALSO SEE AREAS SUCH AS CORRIDOR WHICH DOES NOT
 INDICATE ANY OVER RIDE OR CONTROLS.
 ** IF USING ANY EXCEPTIONS FOR LIGHTS WHICH CAN NOT
 SEEN BY THE OCCUPANT, THEN PLEASE PROVIDE SPECIFIC
 DETAIL FOR ANY PROPOSED KEYPADS WHICH MUST
 CONTAIN*PILOT/INDICATOR LIGHTS*.
  
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2009-06-03 Cont ID  
Sent By mawillia Date 2009-06-03 Time 16:20 Rev Time 0.00
Received By mawillia Date 2009-06-03 Time 16:06 Sent To  
Notes
2009-06-03 16:20:09*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE
 BEEN ADDRESSED; PLAN SHEETS 1.3A, 1.6A, 1.8A, 2.0E, AND
 2.2E WERE STAMPED, INITIALED, AND DATED.
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2009-05-14 Cont ID  
Sent By mawillia Date 2009-05-14 Time 15:38 Rev Time 0.00
Received By mawillia Date 2009-05-14 Time 14:01 Sent To  
Notes
2009-05-14 15:34:40*****UNSAT****
  
 *PREVIOUS COMMENTS WHICH STILL NEED TO BE ADDRESSED:
  
 1. OK
  
 2. ON THE APPROPIATE EXTERIOR ELEVATION (SEE SHEET
 1.3A), SHOW DISPLAY THE SUITE NUMBER THIS LOCATION. AS
 PER WEST PALM BEACH CODE, SUITE NUMBERS SHALL BE NO
 LESS THAN 3" IN HEIGHT AND NO LESS THAN 1" IN
 WIDTH/STROKE.
  
 3. EXIT LIGHTS AND EMERGENCY LIGHTS DO NOT CORRELATE
 WHEN COMPARING THE LIFE SAFETY PLAN (SHEET 1.6A) WITH
 THE LIGHTING PLAN (SHEET 2.0E).
  
 *NEW COMMENT:
  
 A. PROVIDE SPECIFICATION FOR THE TENT/CANOPY FABRIC
 FLAME RESISTANCE.
  
 B. PLEASE SHOW SPRINKLER HEAD LAYOUT TO ASSURE FIRE
 PROTECTION UNDERNEATH THE CANOPIES.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE THE COMMENT WAS ADDRESSED.
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-04-21 Cont ID  
Sent By mawillia Date 2009-04-21 Time 12:10 Rev Time 0.00
Received By mawillia Date 2009-04-21 Time 11:03 Sent To  
Notes
2009-04-21 11:39:35*****UNSAT****
  
  
 1. ON THE COVER SHEET, AMEND GENERAL NOTE #1 TO REFECT
 CURRENT CODES AS FOLLOWS: NFPA 101 (2006 EDITION) AND
 FLORIDA FIRE PREVENTION CODE (2007 EDITION).
  
 2. ON THE APPROPIATE EXTERIOR ELEVATION (SEE SHEET
 1.3A), SHOW DISPLAY THE SUITE NUMBER THIS LOCATION. AS
 PER WEST PALM BEACH CODE, SUITE NUMBERS SHALL BE NO
 LESS THAN 3" IN HEIGHT AND NO LESS THAN 1" IN
 WIDTH/STROKE.
  
 3. EXIT LIGHTS AND EMERGENCY LIGHTS DO NOT CORRELATE
 WHEN COMPARING THE LIFE SAFETY PLAN (SHEET 1.6A) WITH
 THE LIGHTING PLAN (SHEET 2.0E).
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE THE COMMENT WAS ADDRESSED.
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561805-6722

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2009-09-30 Cont ID  
Sent By shill Date 2009-09-30 Time 11:29 Rev Time 0.00
Received By shill Date 2009-09-30 Time 11:29 Sent To  
Notes
2009-09-30 11:29:33TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-08-06 Cont ID  
Sent By lmartine Date 2009-08-06 Time 15:24 Rev Time 0.00
Received By lmartine Date 2009-08-06 Time 15:24 Sent To  
Notes
2009-08-06 15:26:12$$$$$$ --EXPEDITED--$$$$$$ PLUMBING ONLY GAVE TO KEN
 STEVENS

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-07-28 Cont ID  
Sent By jgomez Date 2009-07-28 Time 10:56 Rev Time 0.00
Received By jgomez Date 2009-07-28 Time 10:56 Sent To  
Notes
2009-07-28 10:56:56SENT TO J. WITMER'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2009-07-06 Time   Rev Time 0.00
Received By jwitmer Date 2009-07-06 Time 09:32 Sent To  
Notes
2009-07-06 09:35:03TO JW
2009-07-06 09:32:26ROUTE TO JW

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-05-22 Cont ID  
Sent By dpalmer Date 2009-05-22 Time 15:23 Rev Time 0.00
Received By dpalmer Date 2009-05-22 Time 15:23 Sent To  
Notes
2009-05-22 15:23:38TO C6

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-04-30 Cont ID  
Sent By rregueir Date 2009-04-30 Time 16:28 Rev Time 0.00
Received By rregueir Date 2009-04-30 Time 16:28 Sent To  
Notes
2009-04-30 16:28:28C5

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-21 Cont ID  
Sent By mawillia Date 2009-04-21 Time 12:10 Rev Time 0.00
Received By mawillia Date 2009-04-15 Time 10:11 Sent To  
Notes
2009-04-18 10:12:36TO COMM BD#1

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-08-05 Cont ID  
Sent By rregueir Date 2009-08-05 Time 17:10 Rev Time 0.00
Received By rregueir Date 2009-08-05 Time 17:09 Sent To PC
Notes
2009-08-05 17:10:25REVISED M3.1. STAND DETAIL ON PLANS NOT PART OF THIS
 PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-04-17 Cont ID  
Sent By rregueir Date 2009-04-17 Time 17:24 Rev Time 0.00
Received By rregueir Date 2009-04-17 Time 17:24 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-08-07 Cont ID  
Sent By kstevens Date 2009-08-07 Time 14:20 Rev Time 0.00
Received By kstevens Date 2009-08-07 Time 14:20 Sent To  
Notes
2009-08-07 14:21:27REVISION OK -- SANITARY RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-04-17 Cont ID  
Sent By kstevens Date 2009-04-17 Time 19:05 Rev Time 0.00
Received By kstevens Date 2009-04-17 Time 19:05 Sent To  
Notes
2009-04-17 19:10:38 
  
  
 PASSED/PROVISO:
 HUB DRAIN, MAXIMUM 2 FEET ON INDIRECT PIPING. TRAP
 REQUIRED. SECTION 802.2. -- NO DOUBLE TRAPPING SECTION
 1002.1 -- HUB DRAIN SHALL CONNECT TO THE VENTED LINE,
 NOT SAFE WASTE. A REVISION WILL BE REQUIRED. -- NO DEAD
 ENDS ON DEMO'D PIPING. SECTION 704.5.
  
  
 .

Review Stop Z ZONING
Rev No 1 Status P Date 2009-04-22 Cont ID  
Sent By eschneid Date 2009-04-22 Time 08:28 Rev Time 0.00
Received By eschneid Date 2009-04-22 Time 08:28 Sent To  
Notes
2009-04-22 08:41:51PASSED
  
 1) PLEASE VERIFY THE SUITE NUMBER IS 208. SAITO
 JAPANESE STEAKHOUSE HAS THAT ADDRESS ON THE BUSINESS
 TAX RECEIPT. THIS PLAN APPEAR TO BE FOR THE OLD MARK'S
 RESTAURANT SPACE.
  
 2) PLEASE NOTE THAT ALL SIGNAGE AND AWNINGS REQUIRE A
 SEPARATE PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.