Plan Review Stops For Permit 09040336 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2009-07-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-07-31 |
Time |
09:30 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2009-07-31 |
Time |
09:30 |
Sent To |
|
|
Notes |
2009-07-31 09:31:00 | CAROUSEL CEILING MATERIAL FLAME SPREAD/ SMOKE DEV | | SHEETS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-07-14 |
Time |
13:41 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2009-07-14 |
Time |
13:41 |
Sent To |
|
|
Notes |
2009-07-14 13:42:56 | REVISION# 1 STRUCTURAL SHEET THOMAS TOWMEY P. E. DATED | | 6/30/09 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-06-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-06-03 |
Time |
08:30 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2009-06-03 |
Time |
08:00 |
Sent To |
|
|
Notes |
2009-06-03 08:31:52 | BUILDING PLAN REVIEW | | PERMIT: 09040336 | | ADD: 700 S ROSEMARY# 208 | | CONT: SISCA | | TEL: (561)248-9041 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | JUNE 03/2009 | | 3RD REVIEW | | ACTION: REVIEWED | | | | 1) THIS BUILDING IS A 5 STORY BUILDING (PARKING GARAGE | | PORTION) WHICH ENACTS THE FLORIDA STATE THRESHOLD LAWS: | | BUILDING CLASSIFICATION AS A BUILDING TYPE: I-B/ A2 | | OCCUPANCY | | | | THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " | | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN | | THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | PERSONS. | | | | | | 1B) THRESHOLD INSPECTOR: | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | CODE. | | CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR | | PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION | | BEFORE THE PERMIT MAY BE ISSUED. | | | | 1C) THRESHOLD BLDG, REQUIRED STATEMENT: | | W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | LOCAL AUTHORITY IN | | ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. | | | | | | BUILDING PLAN REVIEW | | PERMIT: 09040336 | | ADD: 700 S ROSEMARY# 208 | | CONT: SISCA | | TEL: (561)248-9041 | | | | BUILDING PROVISO: | | THESE FINISH MATERIAL REQUIREMENTS MUST BE MET BEFORE A | | CERTIFICATE OF COMPLETION CAN BE ISSUED. | | | | 1) 803.6 TEXTILES. WHERE USED AS INTERIOR WALL OR | | CEILING FINISH MATERIALS, TEXTILES, INCLUDING MATERIALS | | HAVING WOVEN OR NONWOVEN, NAPPED, TUFTED, LOOPED OR | | SIMILAR SURFACE AND CARPET AND SIMILAR TEXTILE | | MATERIALS, SHALL COMPLY WITH THE REQUIREMENTS OF | | SECTION 803.6.1, 803.6.2 OR 803.6.3. | | | | 803.6.1 SURFACE BURNING CHARACTERISTIC TEST. TEXTILE | | WALL AND CEILING COVERINGS SHALL HAVE A CLASS A FLAME | | SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE | | PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN | | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. | | | | 803.6.2 ROOM CORNER TEST, TEXTILES. TEXTILE WALL | | COVERINGS SHALL MEET THE CRITERIA OF SECTION 803.6.2.1 | | WHEN TESTED IN THE MANNER INTENDED FOR USE IN | | ACCORDANCE WITH THE METHOD B PROTOCOL OF NFPA 265 USING | | THE PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE. | | | | 803.6.2.1 METHOD B TEST PROTOCOL. DURING THE 40 KW | | EXPOSURE, THE INTERIOR FINISH SHALL COMPLY WITH ITEM 1. | | DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH SHALL | | COMPLY WITH ITEM 2. DURING THE ENTIRE TEST, THE | | INTERIOR FINISH SHALL COMPLY WITH ITEM 3. | | | | 1. DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD | | TO THE CEILING. | | | | 2. DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH | | SHALL COMPLY WITH THE FOLLOWING: | | | | 2.1. FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITIES OF | | THE SAMPLES ON THE 8-FOOT BY 12-FOOT (203 MM BY 305 MM) | | WALLS. | | | | 2.2. FLASHOVER, AS DESCRIBED IN NFPA 265, SHALL NOT | | OCCUR. | | | | 3. THE TOTAL SMOKE RELEASED THROUGHOUT THE NFPA 265 | | TEST SHALL NOT EXCEED 1000 M2. | | | | 803.6.3 ROOM CORNER TEST, CEILING AND WALL FINISH. | | TEXTILE WALL AND CEILING COVERINGS SHALL MEET THE | | CRITERIA OF SECTION 803.2.1 WHEN TESTED IN THE MANNER | | INTENDED FOR USE IN ACCORDANCE WITH NFPA 286 USING THE | | PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE. | | | | 2) FIBERGLASS LIGHT PANELS: | | 2611.1 GENERAL. LIGHT-TRANSMITTING PLASTIC INTERIOR | | WALL SIGNS SHALL BE LIMITED AS SPECIFIED IN SECTIONS | | 2611.2 THROUGH 2611.4. LIGHT-TRANSMITTING PLASTIC | | INTERIOR SIGNS SHALL ALSO COMPLY WITH SECTION 2606. | | | | 2611.2 AGGREGATE AREA. THE SIGN SHALL NOT EXCEED 20 | | PERCENT OF THE WALL AREA. | | | | 2611.3 MAXIMUM AREA. THE SIGN SHALL NOT EXCEED 24 | | SQUARE FEET (2.23 M2). | | | | 2611.4 ENCASEMENT. EDGES AND BACKS OF THE SIGN SHALL BE | | FULLY ENCASED IN METAL. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-05-14 |
Time |
09:40 |
Rev Time |
1.60 |
Received By |
jwitmer |
Date |
2009-05-14 |
Time |
08:00 |
Sent To |
|
|
Notes |
2009-05-14 08:46:47 | BUILDING PLAN REVIEW | | PERMIT: 09040336 | | ADD: 700 S ROSEMARY# 208 | | CONT: SISCA | | TEL: (561)248-9041 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1) THIS BUILDING IS A 5 STORY BUILDING (PARKING GARAGE | | PORTION) WHICH ENACTS THE FLORIDA STATE THRESHOLD LAWS: | | BUILDING CLASSIFICATION AS A BUILDING TYPE: I-B/ A2 | | OCCUPANCY | | | | THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " | | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN | | THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | PERSONS. | | | | 1A)109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A | | SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON | | A THRESHOLD BUILDING PURSUANT TO A STRUCTURAL | | INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE | | STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE | | ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING | | PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING. | | THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO | | PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO | | THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR | | COMPLIANCE WITH THE PERMITTED DOCUMENTS. | | | | 1B) THRESHOLD INSPECTOR: | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | CODE. | | CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR | | PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION | | BEFORE THE PERMIT MAY BE ISSUED. | | | | 1C) THRESHOLD BLDG, REQUIRED STATEMENT: | | W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | LOCAL AUTHORITY IN | | ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. | | | | | | BUILDING PROVISO: | | | | 1) 803.6 TEXTILES. WHERE USED AS INTERIOR WALL OR | | CEILING FINISH MATERIALS, TEXTILES, INCLUDING MATERIALS | | HAVING WOVEN OR NONWOVEN, NAPPED, TUFTED, LOOPED OR | | SIMILAR SURFACE AND CARPET AND SIMILAR TEXTILE | | MATERIALS, SHALL COMPLY WITH THE REQUIREMENTS OF | | SECTION 803.6.1, 803.6.2 OR 803.6.3. | | | | 803.6.1 SURFACE BURNING CHARACTERISTIC TEST. TEXTILE | | WALL AND CEILING COVERINGS SHALL HAVE A CLASS A FLAME | | SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE | | PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN | | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. | | | | 803.6.2 ROOM CORNER TEST, TEXTILES. TEXTILE WALL | | COVERINGS SHALL MEET THE CRITERIA OF SECTION 803.6.2.1 | | WHEN TESTED IN THE MANNER INTENDED FOR USE IN | | ACCORDANCE WITH THE METHOD B PROTOCOL OF NFPA 265 USING | | THE PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE. | | | | 803.6.2.1 METHOD B TEST PROTOCOL. DURING THE 40 KW | | EXPOSURE, THE INTERIOR FINISH SHALL COMPLY WITH ITEM 1. | | DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH SHALL | | COMPLY WITH ITEM 2. DURING THE ENTIRE TEST, THE | | INTERIOR FINISH SHALL COMPLY WITH ITEM 3. | | | | 1. DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD | | TO THE CEILING. | | | | 2. DURING THE 150 KW EXPOSURE, THE INTERIOR FINISH | | SHALL COMPLY WITH THE FOLLOWING: | | | | 2.1. FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITIES OF | | THE SAMPLES ON THE 8-FOOT BY 12-FOOT (203 MM BY 305 MM) | | WALLS. | | | | 2.2. FLASHOVER, AS DESCRIBED IN NFPA 265, SHALL NOT | | OCCUR. | | | | 3. THE TOTAL SMOKE RELEASED THROUGHOUT THE NFPA 265 | | TEST SHALL NOT EXCEED 1000 M2. | | | | 803.6.3 ROOM CORNER TEST, CEILING AND WALL FINISH. | | TEXTILE WALL AND CEILING COVERINGS SHALL MEET THE | | CRITERIA OF SECTION 803.2.1 WHEN TESTED IN THE MANNER | | INTENDED FOR USE IN ACCORDANCE WITH NFPA 286 USING THE | | PRODUCT-MOUNTING SYSTEM, INCLUDING ADHESIVE. | | | | 2) FIBERGLASS LIGHT PANELS: | | 2611.1 GENERAL. LIGHT-TRANSMITTING PLASTIC INTERIOR | | WALL SIGNS SHALL BE LIMITED AS SPECIFIED IN SECTIONS | | 2611.2 THROUGH 2611.4. LIGHT-TRANSMITTING PLASTIC | | INTERIOR SIGNS SHALL ALSO COMPLY WITH SECTION 2606. | | | | 2611.2 AGGREGATE AREA. THE SIGN SHALL NOT EXCEED 20 | | PERCENT OF THE WALL AREA. | | | | 2611.3 MAXIMUM AREA. THE SIGN SHALL NOT EXCEED 24 | | SQUARE FEET (2.23 M2). | | | | 2611.4 ENCASEMENT. EDGES AND BACKS OF THE SIGN SHALL BE | | FULLY ENCASED IN METAL. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2009-04-18 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2009-04-18 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2009-04-18 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2009-10-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-10-08 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-10-08 |
Time |
18:25 |
Sent To |
PC |
|
Notes |
2009-10-08 18:27:02 | PLANS DID NOT CONTAIN CITY PLACE STAMP. NOT FBC OR NEC | | REQUIREMENT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-06-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-29 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-29 |
Time |
13:20 |
Sent To |
|
|
Notes |
2009-05-29 13:24:47 | ** TEMP FAILED STATUS AS NEW SHEETS DO NOT CONTAIN ANY | | STAMPS FROM CITY PLACE MANAGMENT. THIS IS A CITY PLACE | | REQUIREMENT, NOT CITY OF WEST PALM BEACH. IF NO STAMP | | IS REQUIRED FROM CITY PLACE MANAGMENT OFFICE, PLEASE | | OBTAIN IN WRITING AND REVIEW WILL BE CHANGED TO A *P* | | STATUS. IF STAMP IS STILL REQUIRED THEN PLEASE HAVE | | PLANS STAMPED OR REPRESENTIVE FROM CITY PLACE OFFICE | | MAY COME IN AND STAMP AND SIGNS SHEETS. | | PLEASE CONTACT THIS OFFICE AS SOON AS POSSIBLE. | 2009-05-29 13:21:42 | *** NOTES/ REDLINES/ PROVISO **** | | | | 1) NOTE: THE CAROUSEL LIGHTING PANELS AS SHOWN ON PLANS | | SHALL BE FULLY LISTED AS A SIGN. 110.3, 13-415.AB.5, | | THE LISTING SHALL BE PER A NRTL/ SIGN LIGHTING | | MANUFACTURE IN ORDER TO MEET EXEMPTION FROM WATTAGE | | INPUT FOR FBC SECTION NOTED. | | EACH SIGN SHALL BE LISTED INDIVIDUALLY. MAY NOT BE A | | *TYPICAL* LISTING FOR ALL. | | ALL DOCUMENTS SHOWING LISTING ETC SHALL BE SUBMITTED TO | | THIS OFFICE FOR REVIEW PRIOR TO FINAL AND INSTALLATION. | | THIS WAS THE AGREEMENT WITH PLANS EXAMINER AND BUILDING | | OFFICIAL. | | | | 2) NOTE: RISER SHOWS WHAT APPEARS TO BE A NEUTRAL FROM | | H PANEL TO TRANSFORMER. TRANSFORMER IS SEPARATELY | | DERIVED. ONLY PHASE CONDUCTORS AND EQUIPMENT GROUND IS | | INSTALLED. 250.6, 250.20,250.30 | | | | 3) NOTE: ALL FA DEVICES SHALL MEET FBC ADA, | | 11-4.28.1-.4 | | | | 4) NOTE: ALL LOW VOLTAGE SYSTEMS SHALL BE UNDER | | SEPARATE PERMITS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-05-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-08 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-08 |
Time |
15:29 |
Sent To |
|
|
Notes |
2009-05-08 15:29:07 | **DENIED PLANS** | | | | | | | | 1) NOTE: COMPLIANCE WITH FBC 13-415.AB.5 CAN NOT BE | | DETERMINED. | | SOME LIGHTING ON PLANS IS STILL NOT COMPLETE. | | FOR EXAMPLE: PLEASE SEE ELEVATED DINING AREA WHICH | | LIGHTING PLANS SHOW SOME OF THE *D* FIXTURES TO LCP YET | | ON THE POWER PLANS THERE ARE *D* FIXTURES ARE NOT IN | | THE SAME LOCATION AND ARE NOT SHOWN CIRCUITED OR | | CONTROLLED BY LCP OR OTHER TYPE OF DEVICES. | | FOR EXAMPLE: PLEASE SEE G-1 FIXTURES WHICH BASED ON THE | | FIXTURE SYMBOLS AND NOTES ARE NOT DETERMINED AS ANY | | TYPE OF FIXTURE. | | FOR EXAMPLE: KITCHEN AREA LIGHTS CONTAIN NOTES ON PLANS | | WHICH MENTIONS TO CIRCUIT TO LCP HOWEVER THE PLANS DO | | NOT INDICATE ANY NEW OVER RIDES PER 13-415.AC.1.1, | | .1.2. | | | | 2) NOTE: PLEASE SEE 700.12F FOR CIRCUITING IF EMERGENCY | | AND EXIT LIGHTS. THERE ARE NUMEROUS NEW FIXTURES WHICH | | DO NOT SHOW ANY TYPE OF CIRCUITING. THERE ARE SOME | | FIXTURES WHICH ARE NOT CIRCUITED TO THE LOCAL LIGHTING | | IN ANY ONE AREA. SEE SAME FOR EXIT SIGNS. | | SEE FIRE MARSHAL REVIEW COMMENTS FOR REQUIRED EXIT | | SIGNS. (UPPER BAR AREA) SEE NFPA-101 7.8, 7.9 SOME ARE | | MISSING. | | | | 3) NOTE: PLEASE SEE ELECTRICAL RISER. THE RISER NEEDS | | TO BE COORDINATE WITH WHAT IS SHOWN ON RISER WITH | | PANELS. THERE ARE ALSO NEW CIRCUITS BEING ADDED TO | | PANELS SUCH AS PA WHICH THE PANEL SCHEDULE HAS NOT BEEN | | SUBMITTED. IN THE CONVERSATION WITH ELECTRICAL DESIGNER | | THE COMMENT WAS ONLY MADE TO THE EXISTING PANELS IN | | WHICH NO WORK WAS BEING DONE COULD BE DONE AS A | | PROVISO. HOWEVER THE PANELS IN WHICH THE PREDOMINANT | | AMOUNT OF WORK IS BEING DONE NEED TO COORDINATE WITH | | PLANS AND RISER. | | FOR EXAMPLE: PLEASE SEE RISER, ALL PANELS WITH THE | | EXCEPTION OF KA SECTION TWO ARE BEING FED FROM KA | | SECTION #1. HOWEVER BASED ON THE PANEL SCHEDULES FOR KA | | SECTION #1, THERE ARE NO PANELS LISTED. | | PLEASE COORDINATE. | | | | 4) NOTE: PLEASE SEE MULTIPLE RECEPTACLES WITH NO | | CIRCUITING. SOME HAVE NOTES CLOSE TO THE DEVICE AND | | SOME ARE MISSING CIRCUITS. | | 408.4, 240.4, 310.16, 220.14, 220.44 | | | | 5) NOTE: PANEL IN DEDICATE ELECTRICAL CLOSET STILL | | SHOWN ENCROACHING ON THE CLEAR SPACE REQUIRED PER | | 110.26 | | | | 6) NOTE: PLEASE PROVIDE WHERE THE TRANSFORMER IS | | LOCATED IN THE ROOM SHOWN ON PLANS. IS THIS ON FLOOR? | | PLEASE SEE 450.13, 110.26, 450.9, 450.21B ETC. | | | | | | ** ANY AND ALL LOW VOLTAGE SHALL BE UNDER SEPARATE | | PERMITS, FEES AND PLANS. | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-04-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-17 |
Time |
18:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-17 |
Time |
18:42 |
Sent To |
|
|
Notes |
2009-04-17 18:42:41 | ** DENIED ** | | | | | | | | 1) NOTE: PLANS NEED TO BE UNDER THE 2006 NFPA101. ALL | | PLANS SUBMITTED AFTER DECEMBER 31ST 2008 | | FAC 69A-60.003, .004 | | PLANS REVIEWED UNDER NFPA-101 2006, NFPA-70 2005 AND | | 2007 FBC WITH 2009 REVISIONS. | | | | 2) NOTE: PLEASE COMPLETE PLANS FOR ALL LIGHTING AND | | LIGHTING PERFORMANCE CALCULATIONS PER FBC 13-415.AB.5. | | PLANS MAKE REFERENCE TO 13-415.2.C.1, HOWEVER THAT CODE | | NO LONGER EXISTS IN THE CODE. | | PLEASE PROVIDE INFORMATION ON ALL LIGHTING FIXTURES | | SPECIFIC TO MANUFACTURE AND RATING OF FIXTURES. | | ALL FIXTURES SHALL BE INCLUDED IN THE CALCULATIONS | | UNLESS MEETING EXCEPTIONS. IF LIGHTING MEETS | | EXCEPTIONS, PLEASE IDENTIFY AND PROVIDE WHAT WILL MAKE | | THEM EXISTING. | | AS THERE IS MISSING INFORMATION A COMPLETE REVIEW CAN | | NOT BE DONE AT THIS TIME. | | | | ** PLEASE BE SURE ALL LIGHTING AS NOTED AND SHOWN | | CONTAINS A LISTING FROM A NATIONALLY RECOGNIZED TESTING | | LABORATORY. ( NRTL). 110.3 | | | | 3) NOTE: PLEASE SHOW COMPLIANCE WITH FBC 11-4.28.1,.2 | | AND .3 FOR ADA COMPLIANCE. | | | | 4) NOTE: PLEASE SUBMIT COMPLETE LOADS ON ALL PANELS. | | BELOW PANELS THERE ARE NOTES WHICH STATE ONLY NEW | | CIRCUITS ARE SHOWN. HOWEVER WITH THIS SAME STATEMENT | | THIS MEANS ONLY NEW LOADS ARE SHOWN AS NO OTHER LOADS | | ARE SHOWN. | | 220.12,220.14,220.42, 220.43, 220.44 ETC | | PLEASE SEE 215.3, 230.42 FOR CONTINUOUS LOADS. | | ** PLEASE KEEP IN MIND THE SHOW WINDOW LOADS. | | | | 5) NOTE: PLEASE COORDINATE ALL PANELS AND RISER | | DIAGRAM. PLEASE BE SURE TO COORDINATE WITH NOTES ABOVE | | FOR LOAD CALCULATIONS ALSO. | | THIS NOTE WILL BE BROKEN DOWN INTO MULTIPLE SECTIONS AS | | THERE ARE SEVERAL COORDINATION ITEMS WHICH NEED TO BE | | ADDRESSED. | | | | A) PLEASE SEE RISER AS PANEL *L* IS SHOW BEING FED FROM | | PANEL *KA SECTION 1* HOWEVER PER THE PANEL SCHEDULE | | SUBMITTED FOR THIS PANEL, NO PANEL *L* IS FED FROM THIS | | PANEL. PANEL *KA SECTION 2* ALSO DOES NOT LIST PANEL | | *L*. | | | | B) PLEASE SEE RISER AS PANEL *R* IS SHOWN BEING FED | | FROM *KA SECTION 1* HOWEVER BASED ON PANEL SCHEDULES OF | | BOTH SECTION ONE AND TWO, THE PANEL *R* IS ACTUALLY | | BEING FED FROM *KA SECTION 2*. | | | | C) PLEASE SEE RISER AS PANEL *KA SECTION * IS SHOWN | | BEING FED FROM *KA SECTION 2*. THIS SEEMS TO BE | | BACKWARDS AS THE SECTION 2 IS IN FRONT OF SECTION ONE. | | IN EITHER CASE NO MCB IS SHOWN IN SECTION ONE PANEL AND | | SECTION TWO PANEL WHICH IS SHOWN ON THE RISER AS ALL | | TAPPED CONDUCTORS SHALL TERMINATE IN OVER CURRENT | | PROTECTION. IN EITHER CASE A MAIN NEEDS TO BE | | INSTALLED. 240.21 | | ALSO, WHICH PANEL IS ACTUALLY THE FIRST PANEL SECTION? | | | | D) PLEASE SEE RISER AS THERE ARE TWO LIGHTING CONTROL | | PANELS BEING SHOWN WHEN THERE IS ONLY ONE SCHEDULE | | SUBMITTED FOR ONE LIGHTING CONTROL PANEL. | | | | E) PLEASE COORDINATE ALL PANELS AND LOCATIONS OF ALL | | SERVICE EQUIPMENT. PLEASE SEE EQUIPMENT PLANS AS THE | | UNIVERSAL SYMBOL FOR AN ELECTRICAL PANEL INDICATES TWO | | PANELS WHICH ARE NOT ON ANY OTHER SHEETS. THESE ARE IN | | THE KITCHEN AREA NEAR EQUIPMENT NUMBERS 34,35. | | ARE THESE PANELS? | | WHERE IS PANEL PA? | | PLEASE SEE THE TWO LCP ON PLANS DO NOT MEET 110.26 AS | | BOTH ARE SHOWN WITH OVER LAP WHICH ONE WOULD AFFECT THE | | OTHER FOR CODE SECTION GIVEN. THESE MAY ALSO NOT BE | | LOCATED IN ANY TYPE OF STORAGE CLOSET. | | 110.26, 240.24 | | | | | | PLEASE GO OVER ALL PANELS, CIRCUITS, TAPPED CONDUCTORS, | | ETC. SOME ITEMS ARE NOTED FOR BENEFIT HOWEVER ARE NOT | | ALL ITEMS. | | 240.21,215.5, 240.4, 310.16, 408.4, 408.36 ETC | | | | 6) NOTE: ** NOTED FOR INFORMATIONAL PURPOSE. THE LOW | | VOLTAGE SYSTEMS AS SHOWN ON PLANS SUCH AS SPEAKERS, | | PHONE CATV SHALL BE REQUIRED TO BE UNDER SEPARATE | | PERMIT(S) | | THESE PLANS MAY BE REFERENCED FOR TURN AROUND PERMITS | | HOWEVER SEPARATE FEES AND PERMIT APPLICATION(S) ARE | | REQUIRED. | | | | 7) NOTE: PLEASE BE SURE TO COMPLY WITH FBC | | 13-415.1.AB.1.1, .1.2 AND .1.3 FOR LIGHTING CONTROLS. | | ** SEE SEPARATE CONTROLS** | | PLEASE ALSO SEE AREAS SUCH AS CORRIDOR WHICH DOES NOT | | INDICATE ANY OVER RIDE OR CONTROLS. | | ** IF USING ANY EXCEPTIONS FOR LIGHTS WHICH CAN NOT | | SEEN BY THE OCCUPANT, THEN PLEASE PROVIDE SPECIFIC | | DETAIL FOR ANY PROPOSED KEYPADS WHICH MUST | | CONTAIN*PILOT/INDICATOR LIGHTS*. | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-06-03 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-06-03 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-06-03 |
Time |
16:06 |
Sent To |
|
|
Notes |
2009-06-03 16:20:09 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED; PLAN SHEETS 1.3A, 1.6A, 1.8A, 2.0E, AND | | 2.2E WERE STAMPED, INITIALED, AND DATED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-05-14 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-05-14 |
Time |
14:01 |
Sent To |
|
|
Notes |
2009-05-14 15:34:40 | *****UNSAT**** | | | | *PREVIOUS COMMENTS WHICH STILL NEED TO BE ADDRESSED: | | | | 1. OK | | | | 2. ON THE APPROPIATE EXTERIOR ELEVATION (SEE SHEET | | 1.3A), SHOW DISPLAY THE SUITE NUMBER THIS LOCATION. AS | | PER WEST PALM BEACH CODE, SUITE NUMBERS SHALL BE NO | | LESS THAN 3" IN HEIGHT AND NO LESS THAN 1" IN | | WIDTH/STROKE. | | | | 3. EXIT LIGHTS AND EMERGENCY LIGHTS DO NOT CORRELATE | | WHEN COMPARING THE LIFE SAFETY PLAN (SHEET 1.6A) WITH | | THE LIGHTING PLAN (SHEET 2.0E). | | | | *NEW COMMENT: | | | | A. PROVIDE SPECIFICATION FOR THE TENT/CANOPY FABRIC | | FLAME RESISTANCE. | | | | B. PLEASE SHOW SPRINKLER HEAD LAYOUT TO ASSURE FIRE | | PROTECTION UNDERNEATH THE CANOPIES. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE THE COMMENT WAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-04-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-04-21 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-04-21 |
Time |
11:03 |
Sent To |
|
|
Notes |
2009-04-21 11:39:35 | *****UNSAT**** | | | | | | 1. ON THE COVER SHEET, AMEND GENERAL NOTE #1 TO REFECT | | CURRENT CODES AS FOLLOWS: NFPA 101 (2006 EDITION) AND | | FLORIDA FIRE PREVENTION CODE (2007 EDITION). | | | | 2. ON THE APPROPIATE EXTERIOR ELEVATION (SEE SHEET | | 1.3A), SHOW DISPLAY THE SUITE NUMBER THIS LOCATION. AS | | PER WEST PALM BEACH CODE, SUITE NUMBERS SHALL BE NO | | LESS THAN 3" IN HEIGHT AND NO LESS THAN 1" IN | | WIDTH/STROKE. | | | | 3. EXIT LIGHTS AND EMERGENCY LIGHTS DO NOT CORRELATE | | WHEN COMPARING THE LIFE SAFETY PLAN (SHEET 1.6A) WITH | | THE LIGHTING PLAN (SHEET 2.0E). | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE THE COMMENT WAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2009-09-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-09-30 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-09-30 |
Time |
11:29 |
Sent To |
|
|
Notes |
2009-09-30 11:29:33 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2009-08-06 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-08-06 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-08-06 |
Time |
15:24 |
Sent To |
|
|
Notes |
2009-08-06 15:26:12 | $$$$$$ --EXPEDITED--$$$$$$ PLUMBING ONLY GAVE TO KEN | | STEVENS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-07-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-07-28 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-07-28 |
Time |
10:56 |
Sent To |
|
|
Notes |
2009-07-28 10:56:56 | SENT TO J. WITMER'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-07-06 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2009-07-06 |
Time |
09:32 |
Sent To |
|
|
Notes |
2009-07-06 09:35:03 | TO JW | 2009-07-06 09:32:26 | ROUTE TO JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-05-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-22 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-22 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-04-30 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-04-30 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-04-30 |
Time |
16:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-04-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-04-21 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-04-15 |
Time |
10:11 |
Sent To |
|
|
Notes |
2009-04-18 10:12:36 | TO COMM BD#1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-08-05 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-08-05 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-08-05 |
Time |
17:09 |
Sent To |
PC |
|
Notes |
2009-08-05 17:10:25 | REVISED M3.1. STAND DETAIL ON PLANS NOT PART OF THIS | | PERMIT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-04-17 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-04-17 |
Time |
17:24 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-04-17 |
Time |
17:24 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-08-07 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-08-07 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-08-07 |
Time |
14:20 |
Sent To |
|
|
Notes |
2009-08-07 14:21:27 | REVISION OK -- SANITARY RISER DIAGRAM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2009-04-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-04-17 |
Time |
19:05 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-04-17 |
Time |
19:05 |
Sent To |
|
|
Notes |
2009-04-17 19:10:38 | | | | | | | PASSED/PROVISO: | | HUB DRAIN, MAXIMUM 2 FEET ON INDIRECT PIPING. TRAP | | REQUIRED. SECTION 802.2. -- NO DOUBLE TRAPPING SECTION | | 1002.1 -- HUB DRAIN SHALL CONNECT TO THE VENTED LINE, | | NOT SAFE WASTE. A REVISION WILL BE REQUIRED. -- NO DEAD | | ENDS ON DEMO'D PIPING. SECTION 704.5. | | | | | | . |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2009-04-22 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-04-22 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2009-04-22 |
Time |
08:28 |
Sent To |
|
|
Notes |
2009-04-22 08:41:51 | PASSED | | | | 1) PLEASE VERIFY THE SUITE NUMBER IS 208. SAITO | | JAPANESE STEAKHOUSE HAS THAT ADDRESS ON THE BUSINESS | | TAX RECEIPT. THIS PLAN APPEAR TO BE FOR THE OLD MARK'S | | RESTAURANT SPACE. | | | | 2) PLEASE NOTE THAT ALL SIGNAGE AND AWNINGS REQUIRE A | | SEPARATE PERMIT. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|