Plan Review Details - Permit 09040254
Plan Review Stops For Permit 09040254
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-12-01 Cont ID  
Sent By jwitmer Date 2010-12-01 Time 08:08 Rev Time 2.22
Received By jwitmer Date 2010-12-01 Time 08:01 Sent To  
Notes
2010-12-01 08:20:40BUILDING PLAN REVIEW
 PERMIT: 09040254
 ADD: 1443 PALM BEACH LAKES BLVD
 CONT: O/B LARRY BROWN
 TEL: (561)601-9517
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 12/01/2010
  
 1A) THE ORIGINAL PERMIT APPLICATION WAS NOT TURNED IN,
 PLEASE PROVIDE THE ORIGINALS OR SUBMIT A DUPLICATE.
  
 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 EXISTING BUILDING CODE WITH 2009.
 CHAPTER 10- ADDITIONS.
 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 403, 404 AND 405 OF THIS CODE (EXISTING
 BUILDING CODE). IN THE ORIGINAL SECTION OF THE
 RESIDENCE THERE IS ADDITIONAL WORK TO BE COMPLETED,
 RECONFIGURATION OF OF SPACE, THE ADDITION OR
 ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION
 OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY
 ADDITIONAL EQUIPMENT. 404.1 (EXISTING BUILDING CODE).
 PLEASE UPDATE PLANS TO THE 2007 FLORIDA EXISSTING
 BUILDING CODE SECTIONS FOR ALL PLAN REFRENCES.
  
  
 1C) COMPLIED.
  
 1D) THE AREA OF THE ADDITION IS IN A QUESTIONABLE SOILS
 AREA, PLEASE PROVIDE TESTING REPORT INDICATING THE
 MINIMUM SAFE BEARING VALUE OF THE SOILS. R401.4 SOIL
 TESTS. IN AREAS LIKELY TO HAVE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER UNKNOWN SOIL CHARACTERISTICS, THE
 BUILDING OFFICIAL SHALL DETERMINE WHETHER TO REQUIRE A
 SOIL TEST TO DETERMINE THE SOIL'S CHARACTERISTICS AT A
 PARTICULAR LOCATION. THIS TEST SHALL BE MADE BY AN
 APPROVED AGENCY USING AN APPROVED METHOD. PLANS
 INDICATE A.& M. ENGINEERING & TESTING, PLEASE PROVIDE
 (2) SIGNED & SEALED ORIGINALS.
  
  
 2)COMPLIED.
  
 3) COVERSHEET INDICATES THE LOCATION OF THIS PROJECT IN
 A B EXPOSURE, THE 2007 FBC-R 301.2.1.4(3) WILL PUT THIS
 LOCATION IN A C-EXPOSURE, THIS WILL CHANGE THE
 COMPONENTS AND CLADDING PRESSURES, TABLE R-301.2(3)
  
 4) SEMI-COMPLIED. SEE ABOVE STATEMENT.
  
 5) COMPLIED.
  
 6) SHEET 1.2 ON THE NEW ADDITION THE EXTERIOR DOUBLE
 DOORS DOES NOT INDICATE A LANDING. R311.4.3 LANDINGS AT
 DOORS. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE
 OF EACH EXTERIOR DOOR. THE EXTERIOR DOUBLE DOORS IN THE
 NEW ADDITION WILL NEED THE LANDING TO BE A MINIMUM OF
 36 INCHES IN THE DIRECTION OF TRAVEL.
  
 7) SHEET 1.2 INDICATES A NEW MUD ROOM, NEW OPENING
 BETWEEN THE GARAGE AND RESIDENCE, R309.1. R309.1
 OPENING PROTECTION. OPENINGS BETWEEN THE GARAGE AND
 RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT
 LESS THAN 13/8 INCHES (35 MM) IN THICKNESS, SOLID OR
 HONEYCOMB CORE STEEL DOORS NOT LESS THAN 13/8 INCHES
 (35 MM) THICK, OR 20-MINUTE FIRE-RATED DOORS.
  
 8) SHEET 4.1 SEMI-COMPLIED, THE 2008 FBC-R SUPPLEMENTS
 WILL REQUIRE NOT ONLY SMOKE ALARMS BUT R313.4 WILL
 REQUIRE CARBON MONOXIDE ALARMS OR COMBINATION ALARMS
 SINCE THERE IS AN ATTACHED GARAGE. THE OPERATIONAL
 ALRMS MUST BE INSTALLED WITHIN 10 FEET OF EACH ROOM
 USED FOR SLEEPING PURPOSES.
  
 9) SHEET 2.2 ATTIC INSULATION, PLEASE PROVIDE THE FLAME
 SPREAD INDEX AND SMOKE-DEVELOPMENT.R316.1 INSULATION.
 INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR
 RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN
 FLOOR-CEILING ASSEMBLIES, ROOF-CEILING ASSEMBLIES, WALL
 ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME
 SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING
 SMOKE-DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN
 ACCORDANCE WITH ASTM E 84.
  
 10) SHEET 1.2 & 2.1 INDICATES THE USE OF TWO NEW 11 5/8
 INCH LVL BEAMS :
  
 10) COMPLIED.
  
 11) SHEET 2.2 DOES INDICATE COMPLIANCE WITH A ATTIC
 ACCESS DETAIL BUT SHEET 1.2 DOES NOT INDICATE WHERE
 ATTIC ACCESS WILL BE LOCATED WITHIN THE ADDITION.
 106.1.2 ADDITIONAL INFORMATION REQUIRED& R807.1.
  
 12) NEW COMMENT:
 12A) MISSING PRODUCT APPROVAL FOR GLASS BLOCK .
  
 12B) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR
 TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 13) SHEET 2.2 TYPICAL EXTERIOR WALL SECTION DOES NOT
 INDICATE ROOF AND EAVE VENETING REQUIREMENTS. R806.2
 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL
 NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE
 VENTILATED EXCEPT THAT REDUCTION OF THE TOTAL AREA TO
 1/300 IS PERMITTED, PROVIDED THAT AT LEAST 50 PERCENT
 AND NOT MORE THAN 80 PERCENT OF THE REQUIRED
 VENTILATING AREA IS PROVIDED BY ****VENTILATORS****
 LOCATED IN THE UPPER PORTION OF THE SPACE TO BE
 VENTILATED AT LEAST 3 FEET (914 MM) ABOVE THE EAVE OR
 CORNICE VENTS WITH THE BALANCE OF THE REQUIRED
 VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN
 ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA MAY BE
 REDUCED TO 1/300 WHEN A VAPOR BARRIER HAVING A
 TRANSMISSION RATE NOT EXCEEDING 1 PERM (5.7 ?? 10-11
 KG/S ?? M2 ?? PA) IS INSTALLED ON THE WARM-IN-WINTER
 SIDE OF THE CEILING.
  
 14) DOUBLE UNDERLAYMENT AS PER 905.2.2 FOR ASPHALT
 SHINGLES BUT THIS REQUIREMENT IS FOR ROOF SLOPES OF
 LESS THAN 4:12 PITCH. PLEASE MAKE NOTE.
  
 15) STORM SHUTTERS PLEASE COMPLY WITH:
  
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3,
 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING OPENING SIZES, STORY
 HEIGHTS, UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT
 STORM
 BAR REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT
 TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT
 APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT ISSUANCE.A SAMPLE
 SCHEDULE IS ATTACHED.
  
 16) W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT
 FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS,
 MECHANICAL, AND PLUMBING SYSTEMS OR ALTERATIONS
 REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID
 AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE
 ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 CALCULATED VALUE OF $101,950.00 VALUE IS LOW ADJUSTED
 OWES FEES PLUS STATE RADON FEES: $1,246.80. THIS IS THE
 FAIR MARKET VALUE.
  
 17) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-28 Cont ID  
Sent By jwitmer Date 2009-04-28 Time 13:07 Rev Time 0.00
Received By jwitmer Date 2009-04-28 Time 10.33 Sent To  
Notes
2009-04-28 16:26:51BUILDING PLAN REVIEW
 PERMIT: 09040254
 ADD: 1443 PALM BEACH LAKES BLVD
 CONT: O/B LARRY BROWN
 TEL: (561)601-9517
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 EXISTING BUILDING CODE WITH 2009.
 CHAPTER 10- ADDITIONS.
 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 403, 404 AND 405 OF THIS CODE (EXISTING
 BUILDING CODE). IN THE ORIGINAL SECTION OF THE
 RESIDENCE THERE IS ADDITIONAL WORK TO BE COMPLETED,
 RECONFIGURATION OF OF SPACE, THE ADDITION OR
 ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION
 OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY
 ADDITIONAL EQUIPMENT. 404.1 (EXISTING BUILDING CODE).
 PLEASE UPDATE PLANS TO THE 2007 FLORIDA EXISSTING
 BUILDING CODE SECTIONS FOR ALL PLAN REFRENCES.
  
  
 1C) THE ENERGY FORM 600A-2004R IS THE WRONG FORM TO USE
 WOULD BE FORM 1100-07 PRODUCED BY THE ENERGY GAUGE
 USA-FLA/ RES 2007 COMPUTER PROGRAM. 13.600.A.
 NOTE THIS FORM INDICATES THE USE OF A R=30.0 UNDER
 ATTIC INSULATION WHERE AS SHEET 2.2 INDICATES A R=19.
  
 1D) THE AREA OF THE ADDITION IS IN A QUESTIONABLE SOILS
 AREA, PLEASE PROVIDE TESTING REPORT INDICATING THE
 MINIMUM SAFE BEARING VALUE OF THE SOILS. R401.4 SOIL
 TESTS. IN AREAS LIKELY TO HAVE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER UNKNOWN SOIL CHARACTERISTICS, THE
 BUILDING OFFICIAL SHALL DETERMINE WHETHER TO REQUIRE A
 SOIL TEST TO DETERMINE THE SOIL'S CHARACTERISTICS AT A
 PARTICULAR LOCATION. THIS TEST SHALL BE MADE BY AN
 APPROVED AGENCY USING AN APPROVED METHOD.
  
  
 2) SHEET 1.2 FRAMING NOTES 16 AND 22 BOTH ARE NOTES
 THAT ARE ONLY FOR DADE-BROWARD COUNTIES, HIGH VELOCITY
 HURRICANE ZONE, PLEASE CORRECT THE CODE REFRENCES.
  
 3) SHEET 2.1 STORM SHUTTER NOTES INDICATE COMPLIANCE
 WITH SECTION 1619WHICH IN THE 2007 FBC HAS TO DO WITH
 HIGH VELOCITY HURRICANE ZONES- LIVE LOAD REDUCTIONS-
 WHICH IS EXCLUSIVELY FOR DADE AND BROWARD COUNTIES.
 PALM BEACH COUNTY AND THE CITY OF WEST PALM BEACH ARE
 IN A 140 MPH ZONE WHICH IS CONSIDERED A WIND BORNE
 DEBRIS REGION WHICH IS WHEN WINDS ARE GREATER THAN 120
 MPH, 3 SECOND GUST.
  
 4) WIND DESIGN CRITERIA FOUND ON SHEET 2.2 DOES NOT
 PROVIDE THE 3 SECOND GUST AS PART OF THE BASIC WIND
 VELOCITY R301.2(1), SEE FIGURE 301.2(4).
  
 5) SHEET A1.2 INDICATES A NEW BATHROOM IN THE ADDITION
 AND A RECONFIGURED BATH #2 BOTH APPEAR TO HAVE A TUB/
 SHOWER COMPARTMENT, NO INFORMATION HAS BEEN PROVIDED ON
 THE WALL FINISH IN THESE AREAS. R307.2 BATHTUB AND
 SHOWER SPACES. BATHTUB AND SHOWER FLOORS AND WALLS
 ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
 SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
 NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND
 TO A HEIGHT OF NOT LESS THAN 6 FEET (1829 MM) ABOVE THE
 FLOOR.
  
 6) SHEET 1.2 ON THE NEW ADDITION THE EXTERIOR DOUBLE
 DOORS DOES NOT INDICATE A LANDING. R311.4.3 LANDINGS AT
 DOORS. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE
 OF EACH EXTERIOR DOOR.
  
 7) SHEET 1.2 INDICATES A NEW MUD ROOM, NEW OPENING
 BETWEEN THE GARAGE AND RESIDENCE, R309.1. R309.1
 OPENING PROTECTION. OPENINGS BETWEEN THE GARAGE AND
 RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT
 LESS THAN 13/8 INCHES (35 MM) IN THICKNESS, SOLID OR
 HONEYCOMB CORE STEEL DOORS NOT LESS THAN 13/8 INCHES
 (35 MM) THICK, OR 20-MINUTE FIRE-RATED DOORS.
  
 8) SHEET 4.1 IS MISSING SMOKE ALARMS: R313.1 SMOKE
 DETECTION AND NOTIFICATION. ALL SMOKE ALARMS SHALL BE
 LISTED IN ACCORDANCE WITH UL 217 AND INSTALLED IN
 ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND THE
 HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72.
  
 HOUSEHOLD FIRE ALARM SYSTEMS INSTALLED IN ACCORDANCE
 WITH NFPA 72 THAT INCLUDE SMOKE ALARMS, OR A
 COMBINATION OF SMOKE DETECTOR AND AUDIBLE NOTIFICATION
 DEVICE INSTALLED AS REQUIRED BY THIS SECTION FOR SMOKE
 ALARMS, SHALL BE PERMITTED. THE HOUSEHOLD FIRE ALARM
 SYSTEM SHALL PROVIDE THE SAME LEVEL OF SMOKE DETECTION
 AND ALARM AS REQUIRED BY THIS SECTION FOR SMOKE ALARMS
 IN THE EVENT THE FIRE ALARM PANEL IS REMOVED OR THE
 SYSTEM IS NOT CONNECTED TO A CENTRAL STATION.
  
 R313.2 LOCATION. SMOKE ALARMS SHALL BE INSTALLED IN THE
 FOLLOWING LOCATIONS:
  
 1. IN EACH SLEEPING ROOM.
  
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
  
 9) SHEET 2.2 ATTIC INSULATION, PLEASE PROVIDE THE FLAME
 SPREAD INDEX AND SMOKE-DEVELOPMENT.R316.1 INSULATION.
 INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR
 RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN
 FLOOR-CEILING ASSEMBLIES, ROOF-CEILING ASSEMBLIES, WALL
 ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME
 SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING
 SMOKE-DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN
 ACCORDANCE WITH ASTM E 84.
  
 10) SHEET 1.2 & 2.1 INDICATES THE USE OF TWO NEW 11 5/8
 INCH LVL BEAMS :
  
 10A) LOCATION : A) WHERE THE NEW ADDITION MEETS THE
 EXISTING HOUSE A NEW LVL BEAM IS POSISTIONED THERE. IT
 MAY BE ASSUMED THAT IT IS TO REPLACE THE CONCRETE BEAM
 WHERE THE LOAD BEARING WALL IS REMOVED, THE PLAN DOES
 NOT INDICATE ANY NEW FOOTINGS, COLUMNS, MASONRY OR
 STEEL IN THIS LOCATION NO ATTACHMENT DETAILS106.1.2
 ADDITIONAL INFORMATION REQUIRED, THIS AREA WOULD BE
 PART OF THE MAIN WIND FORCE RESISTING SYSTEM,
 CONTINIOUS LOAD PATH FROM FOOTER TO TRUSSES.
  
 10B) LOCATION B) NEW LVL BEAM BETWEEN THE LIVING ROOM
 AND KITCHEN. AS MENTIONED ABOVE THE PLANS DO NOT
 INDICATE IF THIS BEAM IS TO SIT ABOVE THE EXISTING
 TRUSSES REQUIRING BLOCKING TO THE WALL SYSTEM BELOW OR
 THE LVL BEAM IS BELOW THE TRUSS SYSTEM, MISSING TRUSS
 TIES AS WELL AS A SUPPORTING COLUMN, WALL OR BUCKET.
  
 11) SHEET 2.2 DOES INDICATE COMPLIANCE WITH A ATTIC
 ACCESS DETAIL BUT SHEET 1.2 DOES NOT INDICATE WHERE
 ATTIC ACCESS WILL BE LOCATED WITHIN THE ADDITION.
 106.1.2 ADDITIONAL INFORMATION REQUIRED& R807.1.
  
 12) DISCREPANCY BETWEEN 1.2 , 1.3 & 2.4. THE DOUBLE
 TRUSS ON THE RIGHT SIDE SETS BETWEEN TWO WINDOWS WHERE
 AS THE OTHERSHEETS THERE IS ONLY ONE WINDOW. 106.1.2
 ADDITIONAL INFORMATION REQUIRED.
  
 13) SHEET 2.2 TYPICAL WALL SECTION DOES NOT INDICATE
 ROOF AND EAVE VENETING REQUIREMENTS. R806.2 MINIMUM
 AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE
 LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED
 EXCEPT THAT REDUCTION OF THE TOTAL AREA TO 1/300 IS
 PERMITTED, PROVIDED THAT AT LEAST 50 PERCENT AND NOT
 MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA
 IS PROVIDED BY ****VENTILATORS**** LOCATED IN THE UPPER
 PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET
 (914 MM) ABOVE THE EAVE OR CORNICE VENTS WITH THE
 BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR
 CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE
 CROSS-VENTILATION AREA MAY BE REDUCED TO 1/300 WHEN A
 VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING
 1 PERM (5.7 ?? 10-11 KG/S ?? M2 ?? PA) IS INSTALLED ON
 THE WARM-IN-WINTER SIDE OF THE CEILING.
  
 14) NOTE THIS SAME TYPICAL SECTION INDICATES THE USE OF
 DOUBLE UNDERLAYMENT AS PER 905.2.2 FOR ASPHALT SHINGLES
 BUT THIS REQUIREMENT IS FOR ROOF SLOPES OF LESS THAN
 4:12 PITCH. THE PLANS INDICATE THIS ROOF HAVING A 5:12
 PITCH?
  
 15) ELEVATION SHEETS 1.3 & 1.4 BOTH INDICATE THE USE OF
 STORM SHUTTERS PLEASE COMPLY WITH:
  
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3,
 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING OPENING SIZES, STORY
 HEIGHTS, UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT
 STORM
 BAR REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT
 TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT
 APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT ISSUANCE.A SAMPLE
 SCHEDULE IS ATTACHED.
  
 16) W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT
 FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS,
 MECHANICAL, AND PLUMBING SYSTEMS OR ALTERATIONS
 REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID
 AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE
 ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 CALCULATED VALUE OF $101,950.00 VALUE IS LOW ADJUSTED
 OWES FEES PLUS STATE RADON FEES: $1,246.80. THIS IS THE
 FAIR MARKET VALUE.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  

Review Stop E ELECTRICAL
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2011-01-07 Cont ID  
Sent By rlecky Date 2011-01-07 Time 11:38 Rev Time 0.00
Received By rlecky Date 2010-12-13 Time 11:22 Sent To  
Notes
2010-12-13 11:24:3512/13/10 ORIGINIAL ELECTRICAL REVIEW COMMENTS FROM
 4/17/2009 STILL NEED TO BE ADDRESSED. ORIGINAL PLANS
 NEED TO BE INCLUDED IN THIS REIVISION TO VERIFY CURRENT
 CODE COMPLIANCE OF ALL DOCUMENTS. RL

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-04-17 Cont ID  
Sent By btrobaug Date 2009-04-17 Time 16:01 Rev Time 0.00
Received By btrobaug Date 2009-04-17 Time 15:09 Sent To  
Notes
2009-04-17 16:01:15 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 ALL COMMENTS RELATE TO SHEET 4.1 UNLESS OTHERWISE
 NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS
 OTHERWISE NOTED.
  
 1} THERE ARE ELECTRICAL PLANS PROVIDED BUT NO
 ELECTRICAL WORK IN THE DESCRIPTION ON THE APPLICATION.
 ADD DESCRIPTION TO THE APPLICATION.
  
 2} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471
 FS, RESPECTIVELY.
 THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL
 IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES,
 IF EXEMPTIONS APPLY.
  
 3} INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE PLAN
 IS NEW OR EXISTING. IF NEW INCLUDE IN THE DESCRIPTION
 ON THE APPLICATION, PROVIDE AN AIC RATING, AND LOCATE
 ALL SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE,
 DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH
 ARTICLES 225 AND 230 CAN BE REVIEWED. PROVIDE A RISER
 DIAGRAM WITH CONDUCTOR AND CONDUIT SIZE AND TYPE.
  
 4} THE EQUIPMENT GROUND BETWEEN THE METER AND PANEL ON
 THE RISER DIAGRAM CREATES A PARALLEL PATH TO GROUND
 WITH THE NEUTRAL AND MUST BE REMOVED.
  
 5} R313.1 SMOKE ALARMS.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1. IN EACH SLEEPING ROOM.
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS*** THERE ARE NONE OUTSIDE THE
 BEDROOMS. ALSO SEE THE DEFINITION OF "SMOKE DETECTORS"
 11.8.2.1 NFPA-72, CLARIFY IF USING DETECTORS OR ALARMS,
 TO AVOID CONFUSION IN THE FIELD. IF USING DETECTORS
 INDICATE THE LOCATIONS OF THE SOUNDING DEVICES.
  
 6} (E) OUTDOOR OUTLETS FOR A ONE-FAMILY DWELLING AND
 EACH UNIT OF A TWO-FAMILY DWELLING THAT IS AT GRADE
 LEVEL, AT LEAST ONE RECEPTACLE OUTLET ACCESSIBLE AT
 GRADE LEVEL AND NOT MORE THAN 2.0 M (6 1/ 2 FT) ABOVE
 GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF THE
 DWELLING.***ONE REQUIRED IN THE FRONT.
  
 7} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.8(A)(6) GFI.
  
 8} SHOW THE LOCATION OF THE A/C EQUIPMENT ON THE PLAN.
 ALSO SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER
 440.14, RECEPTACLE PER 210.63, LIGHT PER 210.70(A) (3)
 IF APPLICABLE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-01-07 Cont ID  
Sent By rmcdouga Date 2011-01-07 Time 11:29 Rev Time 0.00
Received By rmcdouga Date 2010-11-23 Time 17:57 Sent To  
Notes
2010-11-23 17:57:48SENT TO R1.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-02 Cont ID  
Sent By rbrown Date 2009-05-14 Time 21:03 Rev Time 0.00
Received By rbrown Date 2009-04-10 Time 09:38 Sent To  
Notes
2009-04-14 09:42:52SENT TO RES #8
2009-04-10 16:52:49WAITING FOR "RESIDENTIAL" IN-BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2011-02-10 Cont ID  
Sent By rregueir Date 2011-02-10 Time 13:39 Rev Time 0.00
Received By rregueir Date 2011-02-10 Time 13:19 Sent To  
Notes
2011-02-10 13:36:20REVIEW #: 2ND
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THESE COMMENTS NUMBERED TO CORRESPOND WITH COMMENTS
 FROM PREVIOUS REVIEW CYCLE.
  
 1. OK
  
 2. ENERGY CODE COMPLIANCE FORM IS NOT SINGED BY THE
 PREPARER OR THE OWNER.
  
 3. NO RETURN DUCTS ARE SHOWN ON PLANS. BALANCED RETURN
 IS REQUIRED PER FBC-R SECTION M1602.4.
  
 4. OK
  
 5. FANS SHOWN ON ELECTRICAL PLAN BUT NOT MECHANICAL
 PLAN.
  
 6. OK
  
 NOTE: WHEN PLANS WERE RESUBMITTED, THE PERMIT
 APPLICATION WAS NOT RETURNED TO THE BUILDING
 DEPARTMENT. ALSO, THIS APPLICATION HAD APPROXIMATELY 18
 MONTHS OF INACTIVITY BETWEEN SUBMISSIONS AND IS
 THEREFORE EXPIRED IN ACCORDANCE WITH FBC-B 105.3.2.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-04-24 Cont ID  
Sent By rregueir Date 2009-04-24 Time 10:27 Rev Time 0.00
Received By rregueir Date 2009-04-24 Time 08:47 Sent To  
Notes
2009-04-24 08:53:44REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. PLEASE UPDATE PLANS BY REFERENCING THE NEW 2007
 FLORIDA BUILDING CODE WITH 2009 SUPPLEMENT, WHICH HAS
 BEEN IN EFFECT SINCE MARCH 1, 2009. ALSO, CODE SECTIONS
 REFERENCED IN THE PLAN NOTES ARE FROM THE FLORIDA
 BUILDING CODE, MECHANICAL. THE APPLICABLE CODE FOR THIS
 PROJECT IS THE FLORIDA BUILDING CODE, RESIDENTIAL.
 PLEASE ADJUST ACCORDINGLY.
  
 2. ENERGY CODE COMPLIANCE FORM 600A-04R HAS BEEN
 SUBMITTED. THIS FORM IS NO LONGER VALID FOR PERMITS
 APPLIED FOR ON OR AFTER MARCH 1, 2009. CODE COMPLIANCE
 FOR ADDITIONS SHALL BE DEMONSTRATED BY THE USE OF FORM
 1100A-08 OR 1100B-08 IN ACCORDANCE WITH FBC-R SECTION
 N1100.0.3.
  
 3. THERE ARE NO DUCT SIZES SHOWN ON PLANS. PLEASE SHOW
 THE COMPLETE DUCT DESIGN ON PLANS IN ACCORDANCE WITH
 FBC-B 106.1.1.
  
 4. THE PROPOSED NEW AIR HANDLER APPEARS TO BE LOCATED
 IN THE NEW BATHTUB. PLEASE COORDINATE MECHANICAL AND
 ARCHITECTURAL FLOOR PLANS AND SHOW THE ACTUAL LOCATION
 OF THE AIR HANDLER, RELATED RETURNS AND SUPPLY
 DUCTWORK.
 NOTE: IF AIR HANDLER IS TO BE IN THE ATTIC, SHOW
 COMPLIANCE WITH THE REQUIREMENTS OF FBC-R SECTIONS
 M1305.1.3 FOR SERVICE ACCESS AND M1305.1.3.1 FOR
 LUMINAIRE AND SERVICE RECEPTACLE (COORDINATE WITH
 ELECTRICAL PLANS),
  
 5. NO EXHAUST FAN IS SHOWN IN PROPOSED NEW BATHROOM.
 THERE ARE NO EXTERIOR WINDOWS PROPOSED FOR THIS
 BATHROOM. THEREFORE, MECHANICAL EXHAUST IS REQUIRED IN
 ACCORDANCE WITH FFBC-R SECTION R303.3.
  
 6. ELECTRICAL PLANS DO NOT SHOW ANY POWER BEING
 PROVIDED FOR THE PROPOSED NEW A/C EQUIPMENT. PLEASE
 COORDINATE ELECTRICAL PLANS WITH MECHANICAL PLANS,
 SHOWING PROPERLY SIZED CIRCUITING AND OVERCURRENT
 PROTECTION IN ACCORDANCE WITH FBC-R SECTION M1401.1 AND
 FBC-B 106.1.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-01-07 Cont ID  
Sent By rmcdouga Date 2011-01-07 Time 11:28 Rev Time 0.00
Received By rmcdouga Date 2011-01-07 Time 11:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-04-16 Cont ID  
Sent By kstevens Date 2009-04-16 Time 14:56 Rev Time 0.00
Received By kstevens Date 2009-04-16 Time 14:56 Sent To  
Notes
2009-04-16 15:03:40DENIED
 REFERENCE:
 FBC-2007 W/2009 SUPPLEMENTS
 FBC-2007 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ALL SHEETS THE ADDRESS IN THE TITLE BLOCKS (2669
 FOREST HILL BLVD), DOES NOT REFLECT THE ADDRESS OF
 RECORD ON THE STATE OF FLORIDA DEPT OF BUSINESS
 REGULATION, (DBPR), WEBSITE. PLEASE UPDATE THE TITLE
 BLOCKS OR THE DBPR WEBSITE PRIOR TO RESUBMITTING FOR
 REVIEW. SECTION 106.1.1 AND FAC 61G1-15.23.002(2) & FA
 471.025.
  
 2. SHTS 1.1 & 1.2 PLEASE UPDATE THE CODE REFERENCES TO
 FBC-2007 W/2009 SUPPLEMENTS. THIS CODE WAS ADOPTED FOR
 ALL WORK PERMITTED AFTER MARCH 1 2009. SECTION 106.1.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2010-12-13 Cont ID  
Sent By jroach Date 2010-12-13 Time 15:57 Rev Time 0.00
Received By jroach Date 2010-12-13 Time 15:57 Sent To  
Notes
2010-12-13 15:57:28ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 12/13/2010
 PERMIT NO.: 09040254
 ADDRESS: 1443 PALM BEACH LAKES BOULEVARD
 CONTRACTOR/CONTACT: LARRY BROWN
 TELEPHONE NO.: 561.655.5007
 SCOPE OF REVIEW:
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY
 SHALL BE PROVIDED.
  
 2. A SITE PLAN SHALL BE PROVIDED SHOWING THE LOCATION
 OF ALL EXISTING AND PROPOSED STRUCTURE, MECHANICAL
 EQUIPMENT, ETC. SETBACKS SHALL BE DIMENSIONED FROM ALL
 IMPROVEMENTS TO ADJACENT PROPERTY LINES.
  
 3. PER SECTION 94-441(C)(2) OF THE CITY???S ZONING AND
 LAND DEVELOPMENT REGULATIONS, A LANDSCAPE PERMIT SHALL
 BE SUBMITTED TO CONSTRUCTION SERVICES AS THE PROPOSED
 WORK EXCEEDS 50% OF THE VALUE OF THE STRUCTURE (AS
 LISTED BY THE PALM BEACH COUNTY PROPERTY APPRAISER).
 LANDSCAPE PLANS SHALL BE SUBMITTED IN COMPLIANCE WITH
 ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 4. PLEASE NOTE THE LOCATION OF ALL EXISTING, NEW AND
 RELOCATED MECHANICAL EQUIPMENT (I.E. A/C COMPRESSORS,
 ETC.). PLEASE DIMENSION THE SETBACKS FROM ALL
 MECHANICAL EQUIPMENT TO THE ADJACENT PROPERTY LINES.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-05-14 Cont ID  
Sent By mcruz Date 2009-05-14 Time 10:22 Rev Time 0.00
Received By mcruz Date 2009-05-14 Time 10:09 Sent To  
Notes
2009-05-14 10:21:44PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK
 EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS
 "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 4. INDICATE THE SETBACK DIMENSIONS FROM ANY EXTERIOR
 IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. PURSUANT
 TO THE ZLDR, SECTION 94-72(A)(2): SINGLE-FAMILY LOW
 DENSITY (SF7) RESIDENTIAL DISTRICT - MINIMUM SETBACKS
 FOR PRINCIPAL BUILDING ARE AS FOLLOWS:
  
 A. FRONT: 25 FEET;
  
 B. CORNER: 12.5 FEET;
  
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
  
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 4. INDICATE SETBACK DIMENSIONS FROM PROPOSED/RELOCATED
 A/C EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR,
 SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 5. ****THE FOLLOWING IS FOR INFORMATIONAL PURPOSES
 ONLY*** PLEASE NOTE THAT THE ALLOWABLE DENSITY FOR SF7
 ZONING DISTRICT IS ONE DWELLING UNIT PER LOT. THE
 ADDITION SHALL NOT CONTAIN ANY 220 CONNECTIONS,
 SEPARATE KITCHEN, NOR SHALL A RENTAL LICENSE BE APPLIED
 FOR OR ISSUED IN THE FUTURE.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy