Plan Review Details - Permit 09040087
Plan Review Stops For Permit 09040087
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2009-05-01 Cont ID  
Sent By kstevens Date 2009-05-01 Time 09:14 Rev Time 0.00
Received By kstevens Date 2009-05-01 Time 09:14 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2009-04-14 Cont ID  
Sent By kstevens Date 2009-04-14 Time 14:07 Rev Time 0.00
Received By kstevens Date 2009-04-14 Time 14:07 Sent To  
Notes
2009-04-14 14:24:44DENIED
 REFERENCE:
 FBC-2007 RESIDENTIAL
  
 A. THE FOLLOWING INFORMATION IS REQUIRED FOR GAS
 PERMIT:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2007
 FUEL GAS CODE. THE PIPE SCHEMATIC SUBMITTED IN NOT IN
 ISOMETRIC FORM. THE SCHEMATIC INDICATES THAT THE PE
 POLY PIPE IS UNDERGROUND AND IF SO THE METER IS ALSO
 SHOWN UNDERGROUND. THE RANGE COOKTOP PIPING IS NOT
 CLEAR IN HOW IT WILL BE RUN. (SEE EXAMPLE OF ISOMETRIC
 DRAWING).
  
 2. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2007 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
  
 3. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2007 FUEL GAS
 CODE SECTION 304.
  
 4. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2007 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI. - THE PLANS SHOW A
 2PSI METER, BUT INDICATES 12" WC AT THE APPLIANCES. IF
 THE METER IS 2PSI THEN GAS REGULATORS WILL BE REQUIRED.
 PLEASE CLAIFY.
  
 B. PLANS INDICATE THE WORK SHALL COMPLY WITH NFPA 54.
 PLEASE BE ADVISED THAT NFPA 54 WAS NOT ADOPTED BY
 FBC-2007 AND THAT THE DESIGN SHALL BE PER FBC-2007
 RESIDENTIAL/2007 FUEL GAS CODE. PLEASE CHANGE
 REFERENCE.
  
 C. THE PERSON RESPONSIBLE FOR THE DRAWINGS SHALL PRINT
 THEIR NAME AND PUT THEIR SIGNATURE ON THE PLANS.
 SECTION 1-6.1.3.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-29 Cont ID  
Sent By swurafti Date 2009-04-29 Time 11:00 Rev Time 0.00
Received By swurafti Date 2009-04-29 Time 11:00 Sent To G
Notes
2009-04-29 11:03:12TO "KSTEVENS" DESK


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved