Plan Review Stops For Permit 09040032 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2009-08-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-08-13 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-08-13 |
Time |
15:07 |
Sent To |
|
|
Notes |
2009-08-13 15:07:21 | REVISION (ROOF NOA) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2009-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-20 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-07-20 |
Time |
11:36 |
Sent To |
|
|
Notes |
2009-07-20 11:43:10 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. PLEASE SEE ATTACHED; THIS NOA HAS A "FILE CLOSED" | | STATUS. IT IS MY UNDERSTANDING THAT THIS NOA HAS | | TYPOGRAPHICAL ERRORS AND HAS BEEN SUPERSEDED BY A MORE | | CURRENT NOA. | | | | 2. WHEN SUBMITTING A VALID, CURRENT PRODUCT APPROVAL, | | PLEASE SUBMIT A COMPLETE DOCUMENT. THE LAST PAGE OF THE | | NOA IS MISSING. (OTHER SHEETS FOR OTHER ASSEMBLIES DO | | NOT NEED TO BE SUBMITTED) | | | | 3. WHEN RESUBMITTING, PLEASE NOTE WHICH APPROVED | | ASSEMBLY IS BEING USED. ALSO NOTE GENERAL LIMITATION #7 | | ON THE LAST PAGE OF THE NOA; IF ENHANCED FASTENING IS | | REQUIRED, CALCULATIONS ARE TO BE PREPARED BY AN | | ENGINEER, ARCHITECT, OR REGISTERED ROOF CONSULTANT IF | | THAT REQUIREMENT IS LISTED ON THE NOA. | | | | 4. PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF | | RECORD, FBC*103. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-07-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-07-16 |
Time |
19:25 |
Rev Time |
|
Received By |
shill |
Date |
2009-07-16 |
Time |
19:19 |
Sent To |
Z |
|
Notes |
2009-07-16 19:25:53 | REVISION #2, SP1, D1, A1, A2, S1, S2 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-05-18 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-05-18 |
Time |
09:49 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-04-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-04-15 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-04-14 |
Time |
15:55 |
Sent To |
|
|
Notes |
2009-04-15 15:09:20 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. INCORRECT ASCE-7 REFERENCE USED, FBC R43. | | | | 2. ENHANCED FASTENING CALCULATIONS SPECIFY INCORRECT | | CODE VERSION (SHOULD BE FBC2007); PLEASE REVISE. | | | | 3. ENHANCED FASTENING, FRACTION OF INCH CANNOT BE USED | | IN SPECIFICATION, RAS117 SECTION 9. | | | | 4. PROVIDE CALCULATIONS FOR ZONE 3 DESIGN PRESSURES. | | SEE ASCE7-05 FIGURE 6-3 (ENCLOSED), ZONE 3, DESIGN | | PRESSURE IS -89PSF FOR EXPOSURE B; YOU'VE DECLARED -72 | | FOR ZONE 3, EXPOSURE C, SEE ALSO COMMENT #7. | | | | 5. SECTION 905.3 IS REFERENCED FOR SHINGLE | | INSTALLATION; THIS IS FOR ROOF TILE INSTALLATION. | | | | 6. TWO DIFFERENT SHEATHING NAILING PATTERNS PROVIDED; | | ONE DOES NOT COMPLY WITH FBC R803.2.3.1; SEE SHEET S3 | | PLYWOOD NAILING DETAIL. | | | | 7. PLEASE SEE DEFINITION OF ENCLOSED BUILDING, | | ASCE7-05. IT APPEARS THAT THIS PORTION OF THE BUILDING | | WOULD BE DEFINED UNDER PARTIALLY ENCLOSED; PLEASE | | EXPLAIN RATIONALE FOR ENCLOSED (AS EVIDENCED BY .18 | | COEFFICIENT). | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-08-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-08-13 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-08-13 |
Time |
12:59 |
Sent To |
|
|
Notes |
2009-08-13 13:00:14 | SENT TO S. HILL'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-07-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-07 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-07 |
Time |
17:05 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-05-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-05-18 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-05-11 |
Time |
11:30 |
Sent To |
|
|
Notes |
2009-05-13 11:32:30 | GAVE TO SAMANTHA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-04-23 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-04-06 |
Time |
14:14 |
Sent To |
|
|
Notes |
2009-04-06 14:14:28 | TO "R15" |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2009-07-20 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-07-20 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-07-20 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-05-18 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-05-18 |
Time |
11:13 |
Sent To |
B |
|
Notes |
2009-05-18 11:13:51 | RE-STAMP | | | | SENT BACK TO SHILL |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2009-04-23 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-04-23 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-04-23 |
Time |
13:24 |
Sent To |
|
|
Notes |
2009-04-23 13:58:47 | PLACED BACK ON RES. SHELF |
|
|