Plan Review Details - Permit 09030379
Plan Review Stops For Permit 09030379
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-05-18 Cont ID  
Sent By shill Date 2009-05-18 Time 13:48 Rev Time 0.00
Received By shill Date 2009-05-18 Time 13:48 Sent To  
Notes
2009-05-18 13:48:48CALCULATIONS OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-05-06 Cont ID  
Sent By shill Date 2009-05-06 Time 14:24 Rev Time 0.00
Received By shill Date 2009-05-06 Time 14:24 Sent To  
Notes
2009-05-06 14:24:43PROVISO - PROVIDE CALCS REFERRING TO CORRECT BUILDING
 CODE AND PROJECT NAME
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-04-07 Cont ID  
Sent By shill Date 2009-04-07 Time 09:07 Rev Time 0.00
Received By shill Date 2009-04-07 Time 09:07 Sent To  
Notes
2009-04-07 09:08:05STAMPED SHEET E20

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-04-30 Cont ID  
Sent By dpalmer Date 2009-04-30 Time 15:00 Rev Time 0.00
Received By dpalmer Date 2009-04-30 Time 15:00 Sent To B
Notes
2009-04-30 15:01:21SENT TO SH'S DESK AS THERE ARE NEW SHEETS AND WIND LOAD
 CALCULATIONS.
  
 ELEC OK>

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-04-14 Cont ID  
Sent By dpalmer Date 2009-04-14 Time 08:40 Rev Time 0.00
Received By dpalmer Date 2009-04-14 Time 08:40 Sent To PC
Notes
2009-04-14 08:40:25** DENIED**
  
  
  
 1) NOTE: THE APPLIED LOCATIONS AND SCOPE OF WORK ON
 PERMIT APPLICATION DO NOT CORRELATE.
 THE APPLIED LOCATION IS FOR LAKEWOOD RD, HOWEVER PLANS
 SUBMITTED INCLUDE GARDEN AVE, LAKE AVE. ON SAME GRID OR
 AREA OR METER.
 BASED ON THE SCOPE OF WORK SUBMITTED ON PLANS THERE
 WOULD BE SEPARATE PERMIT APPLICATIONS AS LIGHTING IS
 BEING FED FROM MORE THAN ONE SERVICE POINT. THE FACT IS
 THERE IS NO SERVICE POINT LOCATION SHOWN. NO SERVICE
 RISER SHOWN IF BEING FED FROM NEW METERED SERVICE.
 ** PLEASE SUBMIT PLANS ONLY FOR SCOPE OF WORK BEING
 APPLIED FOR.
  
 2) NOTE: THE APPLIED VALUATION CAN NOT BE DETERMINED
 BASED ON THE PLANS SUBMITTED, THE AMOUNT OF WORK SHOWN
 COMPARED TO THE ACTUAL SCOPE SHOWN.
 VALUE MUST INCLUDE ALL LABOR, MATERIALS, EQUIPMENT,
 DESIGN COSTS EVEN IF ANY OF THESE ITEMS ARE OWNER
 SUPPLIED.
 FBC 108.3
  
  
  
  
  
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2009-04-30 Cont ID  
Sent By mgonzale Date 2009-04-30 Time 12:05 Rev Time 2.00
Received By mgonzale Date 2009-04-30 Time 12:05 Sent To  
Notes
2009-04-30 12:06:59**** PASSED ****
  
 HURRICANE WIND CALCS INCLUDED.
 PLANS REVISED TAKING IN CONSIDERATION PREVIOUS COMMETS.
  
 [email protected]
 (561) 494-1085
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2009-04-10 Cont ID  
Sent By mgonzale Date 2009-04-10 Time 07:55 Rev Time 1.00
Received By mgonzale Date 2009-04-10 Time 07:55 Sent To ENG
Notes
2009-04-10 07:55:49PLANS NOT APPROVED DUE TO MANY CONFLICTS BETWEEN LIGHT
 POLES AND EXISTING UTILITIES.
  
 #1 PROVIDE STANDARD DETAIL SHOWING MINIMUM DISTANCE
 BETWEEN NEW POLES AND EXISTING WATER, SEWER, AND FIRE
 HYDRANTS.
  
 #2 PROVIDE STANDARD DETAIL SHOWING MINIMIM A.D.A
 ACCESSABILITY DISTANCES TO NEW POLES.
  
 #3 HURRICANE WIND INFORMATION FOR POLES AND FIXTURES
 WHERE NOT INCLUDED.
  
 RE-SUBMIT.
  
 [email protected]
 (561) 494-1078
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-04-29 Cont ID  
Sent By dpalmer Date 2009-04-29 Time 11:37 Rev Time 0.00
Received By dpalmer Date 2009-04-29 Time 11:37 Sent To E
Notes
2009-04-29 11:37:37TO DVP'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-04-22 Cont ID  
Sent By dpalmer Date 2009-04-22 Time 11:19 Rev Time 0.00
Received By dpalmer Date 2009-04-22 Time 11:19 Sent To E
Notes
2009-04-22 11:19:32TO DVP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-14 Cont ID  
Sent By   Date 2009-04-14 Time   Rev Time 0.00
Received By adarroug Date 2009-03-17 Time 16:02 Sent To  
Notes
2009-03-17 16:07:49TO "COMM" BD#18

Review Stop Z ZONING
Rev No 1 Status N Date 2009-04-02 Cont ID  
Sent By eschneid Date 2009-04-02 Time 17:12 Rev Time 0.50
Received By eschneid Date 2009-04-02 Time 17:12 Sent To  
Notes
***NONE***