Plan Review Stops For Permit 09030379 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-05-18 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-05-18 |
Time |
13:48 |
Sent To |
|
|
Notes |
2009-05-18 13:48:48 | CALCULATIONS OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-05-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-05-06 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-05-06 |
Time |
14:24 |
Sent To |
|
|
Notes |
2009-05-06 14:24:43 | PROVISO - PROVIDE CALCS REFERRING TO CORRECT BUILDING | | CODE AND PROJECT NAME | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2009-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-04-07 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-04-07 |
Time |
09:07 |
Sent To |
|
|
Notes |
2009-04-07 09:08:05 | STAMPED SHEET E20 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-04-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-30 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-30 |
Time |
15:00 |
Sent To |
B |
|
Notes |
2009-04-30 15:01:21 | SENT TO SH'S DESK AS THERE ARE NEW SHEETS AND WIND LOAD | | CALCULATIONS. | | | | ELEC OK> |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-04-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-14 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-14 |
Time |
08:40 |
Sent To |
PC |
|
Notes |
2009-04-14 08:40:25 | ** DENIED** | | | | | | | | 1) NOTE: THE APPLIED LOCATIONS AND SCOPE OF WORK ON | | PERMIT APPLICATION DO NOT CORRELATE. | | THE APPLIED LOCATION IS FOR LAKEWOOD RD, HOWEVER PLANS | | SUBMITTED INCLUDE GARDEN AVE, LAKE AVE. ON SAME GRID OR | | AREA OR METER. | | BASED ON THE SCOPE OF WORK SUBMITTED ON PLANS THERE | | WOULD BE SEPARATE PERMIT APPLICATIONS AS LIGHTING IS | | BEING FED FROM MORE THAN ONE SERVICE POINT. THE FACT IS | | THERE IS NO SERVICE POINT LOCATION SHOWN. NO SERVICE | | RISER SHOWN IF BEING FED FROM NEW METERED SERVICE. | | ** PLEASE SUBMIT PLANS ONLY FOR SCOPE OF WORK BEING | | APPLIED FOR. | | | | 2) NOTE: THE APPLIED VALUATION CAN NOT BE DETERMINED | | BASED ON THE PLANS SUBMITTED, THE AMOUNT OF WORK SHOWN | | COMPARED TO THE ACTUAL SCOPE SHOWN. | | VALUE MUST INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, | | DESIGN COSTS EVEN IF ANY OF THESE ITEMS ARE OWNER | | SUPPLIED. | | FBC 108.3 | | | | | | | | | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2009-04-30 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2009-04-30 |
Time |
12:05 |
Rev Time |
2.00 |
Received By |
mgonzale |
Date |
2009-04-30 |
Time |
12:05 |
Sent To |
|
|
Notes |
2009-04-30 12:06:59 | **** PASSED **** | | | | HURRICANE WIND CALCS INCLUDED. | | PLANS REVISED TAKING IN CONSIDERATION PREVIOUS COMMETS. | | | | [email protected] | | (561) 494-1085 | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2009-04-10 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2009-04-10 |
Time |
07:55 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2009-04-10 |
Time |
07:55 |
Sent To |
ENG |
|
Notes |
2009-04-10 07:55:49 | PLANS NOT APPROVED DUE TO MANY CONFLICTS BETWEEN LIGHT | | POLES AND EXISTING UTILITIES. | | | | #1 PROVIDE STANDARD DETAIL SHOWING MINIMUM DISTANCE | | BETWEEN NEW POLES AND EXISTING WATER, SEWER, AND FIRE | | HYDRANTS. | | | | #2 PROVIDE STANDARD DETAIL SHOWING MINIMIM A.D.A | | ACCESSABILITY DISTANCES TO NEW POLES. | | | | #3 HURRICANE WIND INFORMATION FOR POLES AND FIXTURES | | WHERE NOT INCLUDED. | | | | RE-SUBMIT. | | | | [email protected] | | (561) 494-1078 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-29 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-29 |
Time |
11:37 |
Sent To |
E |
|
Notes |
2009-04-29 11:37:37 | TO DVP'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-04-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-22 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-22 |
Time |
11:19 |
Sent To |
E |
|
Notes |
2009-04-22 11:19:32 | TO DVP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-04-14 |
|
|
Cont ID |
|
Sent By |
|
Date |
2009-04-14 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-03-17 |
Time |
16:02 |
Sent To |
|
|
Notes |
2009-03-17 16:07:49 | TO "COMM" BD#18 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2009-04-02 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-04-02 |
Time |
17:12 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2009-04-02 |
Time |
17:12 |
Sent To |
|
|
Notes |
|
|