Plan Review Details - Permit 09030373
Plan Review Stops For Permit 09030373
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-04-10 Cont ID  
Sent By shill Date 2009-04-10 Time 10:58 Rev Time 0.00
Received By shill Date 2009-04-10 Time 10:58 Sent To Z
Notes
2009-04-10 11:05:59ONE SET INCOMPLETE

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-06 Cont ID  
Sent By shill Date 2009-04-06 Time 14:34 Rev Time 0.00
Received By shill Date 2009-04-06 Time 14:34 Sent To  
Notes
2009-04-06 14:34:43****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. SOME SHEETS SUBMITTED ARE NOT SIGNED AND SEALED.
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 FS471.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-04-09 Cont ID  
Sent By dpalmer Date 2009-04-09 Time 18:58 Rev Time 0.00
Received By dpalmer Date 2009-04-09 Time 18:58 Sent To B
Notes
2009-04-09 18:59:22ROUTED TO SH.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-04-02 Cont ID  
Sent By dpalmer Date 2009-04-02 Time 17:04 Rev Time 0.00
Received By dpalmer Date 2009-04-02 Time 17:03 Sent To B
Notes
2009-04-02 17:04:12** DENIED REVIEW **
  
 1) NOTE: PLEASE KNOW THAT PER FS 553.73: THE STATE OF
 FLORIDA AS OF MARCH 31ST,2009 HAS ADOPTED THE 2007 FBC
 WITH 2009 GLITCH AMENDMENTS.
 THE PLANS SUBMITTED ARE UNDER 2004 FBC.
 PLEASE ALSO SEE THE ELECTRICAL CODE REFERENCE ON PLANS
 FOR GROUNDING IS FROM THE 1996 NEC.
 THE CURRENT SECTION UNDER THE 2005 NEC IS NOT 250.95
 FOR EQUIPMENT GROUNDING CONDUCTORS.
  
 2) NOTE: PLEASE PROVIDE MORE INFORMATION ON THE LED
 LIGHTING SHOWN FOR SIGN. THERE IS NO INFORMATION ON THE
 DRIVER OR VOLTAGE WHICH DRIVES THESE LIGHTS.
 NO DISCONNECT SWITCH SHOWN.
 600.7,600.6,600.5,250.122, ETC
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-04-09 Cont ID  
Sent By dpalmer Date 2009-04-09 Time 18:58 Rev Time 0.00
Received By dpalmer Date 2009-04-09 Time 18:58 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-03-31 Cont ID  
Sent By adarroug Date 2009-03-31 Time 16:14 Rev Time 0.00
Received By adarroug Date 2009-03-31 Time 16:14 Sent To E
Notes
2009-03-31 16:14:18TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-06 Cont ID  
Sent By shill Date 2009-04-06 Time 14:34 Rev Time 0.00
Received By shill Date 2009-03-17 Time 11:35 Sent To  
Notes
2009-03-17 11:35:50TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2009-04-10 Cont ID  
Sent By mflis Date 2009-04-10 Time 13:06 Rev Time 0.00
Received By mflis Date 2009-04-10 Time 13:06 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2009-03-24 Cont ID  
Sent By mflis Date 2009-03-24 Time 16:22 Rev Time 0.00
Received By mflis Date 2009-03-24 Time 16:22 Sent To B
Notes
2009-03-24 16:23:05ZONING REVIEW: PASSED
  
 ** APPROVED FOR SIZE AND LOCATION; COLOR, FINAL
 FINISHES, AND GRAPHICS TO BE SELECTED BY ARCHITECT
  
 MATT FLIS - 822-1445