Plan Review Details - Permit 09030353
Plan Review Stops For Permit 09030353
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2009-05-13 Cont ID  
Sent By jnguyen Date 2009-05-13 Time 10:46 Rev Time 0.00
Received By jnguyen Date 2009-05-13 Time 09:58 Sent To  
Notes
2009-05-13 10:40:08THIS PERMIT WAS FOR WORK TO BE DONE ON THE FRONT
 STRUCTURE (539 21ST ST) & THE REAR ONE (539 1/2 21ST
 ST). ROBERT MCDOUGAL BROUGHT AN ADDRESSING ISSUE TO MY
 ATTENTION BECAUSE 1/2 ADDRESSES WERE IN VIOLATION WITH
 THE CITY'S POLICY & ORDINANCE. UNDER SECTION 1.3 OF THE
 CITY'S ADDRESSING POLICY: ADDITIONS TO THE PRIMARY
 HOUSE NUMBERS, SUCH AS "1/2 OR UNIT A" ARE NO LONGER
 ALLOWED. I IMPLEMENTED A SECONDARY ADDRESSING CHANGE
 FROM 539 1/2 21ST ST TO 541 21ST ST FOR THE REAR
 STRUCTURE. I SENT OUT A NOTIFICATION E-MAIL TO ALL OF
 THE RELEVANT PARTIES (PAPA, FPL, USPS, CONTRACTOR,
 ETC.) TO INFORM THEM OF THE ADDRESSING ADJUSTMENT. I
 FORMULATED THE ADDRESS POINT OF 541 21ST ST IN GIS, AND
 CREATED THE SEQUENTIAL UNIT RECORD 0001 - 541 21ST ST
 UNDER PCN# 74434316140030190 IN COMMUNITYPLUS. PLEASE
 FIX THE ADDRESS ON THE ORIGINAL PERMIT APPLICATION FROM
 539 & 539 1/2 21ST ST TO 539 & 541 21ST ST (AS I WAS
 ONLY PROVIDED WITH A COPY).

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-09-22 Cont ID  
Sent By rmcdouga Date 2009-09-22 Time 15:19 Rev Time 0.00
Received By rmcdouga Date 2009-09-22 Time 15:19 Sent To  
Notes
2009-09-22 15:27:37REVISED SHEET 1.2
 MOVED BATH ROOM WALL TO ALLOW PROPER SPACING FOR
 FIXTURES. CHANGE SIZE OF BEDROOM DOORS FROM 2'-8" TO
 2'-6" WIDTHS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-05-13 Cont ID  
Sent By rmcdouga Date 2009-05-13 Time 14:07 Rev Time 0.00
Received By rmcdouga Date 2009-05-13 Time 14:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-14 Cont ID  
Sent By rmcdouga Date 2009-04-14 Time 08:58 Rev Time 0.00
Received By rmcdouga Date 2009-04-14 Time 08:58 Sent To  
Notes
2009-04-14 11:07:182007 FBC
 LEVEL 3 ALTERATION
  
 DENIED BY BUILDING
  
 NOTE: A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 WILL BE REQUIRED. FS 713
  
 1) SPECIFY THE LEVEL OF ALTERATION FOR THE PROPOSED
 WORK ON SHEET 1.2. SEE LEVEL 3 ALTERATION IN THE 2007
 FBC EXISTING BUILDING. FBC EB SECTION 401.4.
  
 2) UPDATE THE EDITION OF ASCE 7 -02 SPECIFIED ON SHEET
 1.2 TO CORRESPOND TO THE 2007 FBC WHICH REFERENCES ASCE
 7-05.
  
 3) ON 1.2 UNDER CODES FOR REFERENCE, PLEASE UPDATE 2004
 FBC W/2006 REVISIONS TO 2007 FBC.
  
 4) OM THE FOUNDATION PLAN ON SHEET 2.2 REFERENCES ARE
 MADE TO DETAILS ON DRAWING 2.1. THERE IS NO DRAWING
 SHEET 2.1, THESE DETAILS ARE LOCATED ON SHEET 2.2.
 PLEASE CORRECT.
  
 5) SECTION C ON 2.2 FOR THE 4" X 4" WOOD COLUMN AT THE
 FRONT PORCH DOES NOT SPECIFY THE CONNECTOR FOR THE BASE
 OF THE COLUMN. THE NOTE IS FOR ATTACHING A WOOD FRAME
 WALL. PLEASE CORRECT.
  
 6) THE ROOF SHEATHING FASTENING THAT IS SPECIFIED ON
 SHEET 2.2 IS INCORRECT. FBC R803.2.3.1 REQUIRES 8D RING
 SHANK NAILS AT 6" OC AT EDGES AND INTERMEDIATE FRAMING
 IN ROOF ZONES 1 AND 2 AND 4" OC IN ZONE 3. PLEASE
 REVISE.
  
 7) ENERGY CALCULATION FORM 600 C-04R WAS SUBMITTED FOR
 539-1/2 21ST STREET. THE PERMIT APPLICATION IS ONLY FOR
 THE MAIN HOUSE AND DOES NOT MENTION THE OTHER
 STRUCTURE. PLEASE REMOVE THIS FORM. NOTE: THE 2008
 VERSION OF THE FORM IS REQUIRED BY THE 2007 FBC.
  
 8) PLEASE SUBMIT THE 2008 ENERGY CALCULATION FORMS AS
 REQUIRED BY 2007 FBC GLITCH AMENDMENTS R N1100.3.
  
 9) UPDATE THE STATE PRODUCT APPROVALS TO THE 2007 CODE
 VERSIONS. DCA RULE 9B-72.
  
 10) SUBMIT TWO (2) CLEAR COPIES OF THE JELD WEN
 OUTSWING DOOR PRODUCT APPROVALS. DCA RULE 9B-72 AND FBC
 106.1* CITY AMENDMENTS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-05-06 Cont ID  
Sent By dpalmer Date 2009-05-06 Time 12:59 Rev Time 0.00
Received By dpalmer Date 2009-05-06 Time 12:59 Sent To  
Notes
2009-05-06 13:01:01REDLINED PLANS. THE THIRD SMALL APPLIANCE CIRCUIT WAS
 NOT FIGURED INTO LOAD CALCULATIONS AS STATED IN
 PREVIOUS REVIEW COMMENTS AND 220.52/53 OF THE NEC. THIS
 WILL NOT AFFECT THE SERVICE SIZE. PLEASE REVISE WITH
 CORRECTION IF THERE ARE ANY OTHER REVISIONS BEFORE
 ROUGH.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-04-10 Cont ID  
Sent By dpalmer Date 2009-04-10 Time 13:08 Rev Time 0.00
Received By dpalmer Date 2009-04-10 Time 13:08 Sent To  
Notes
2009-04-10 13:08:46* DENIED**
  
 1) NOTE: RISER INDICATES THE METER CAN AT 200AMPS
 HOWEVER THIS IS NOT RATED FOR THE SERVICE SIZE AS
 SHOWN.
 110.3 90.7
  
 2) NOTE: PLEASE SEE SMOKE ALARM WHICH NEEDS TO BE
 LOCATED INSIDE BEDROOM. THIS WOULD HAVE BEEN REDLINED
 IF IT WAS THE ONLY ITEM. NFPA-72 11.5.1.
  
 3) NOTE: PLEASE SEE 422.13 AS THE LOAD FOR THE WATER
 HEATER NEEDS TO BE SHOWN AT 125%. NEW IN 2005 NEC AS OF
 DECEMBER 2006.
  
 4) NOTE: PLEASE SEE WATER HEATER IS SHOWN WITH A
 RECEPTACLE WITH CORD AND PLUG CONNECTION WHICH IS NOT
 PERMITTED. 422.30, 422.31
 MUST BE A DISCONNECT.
 ** STORAGE TYPE WATER HEATER ALSO SHOWN AS BEING
 OUTSIDE WHICH MUST BE LISTED TO BE LOCATED OUTSIDE.
  
 5) NOTE: MISSING REQUIRED DISCONNECT FOR CONDENSING
 UNIT. 440.11
  
 6) NOTE: MISSING WP GFI FOR CONDENSING UNIT PER 210.63,
 210.8A
  
 7) NOTE: PLEASE SEE PANEL SCHEDULE WHICH INDICATES A
 CIRCUIT FOR SMALL APPLIANCE #13 HOWEVER NO #13 IS ON
 PLANS.
 CIRCUIT #17 IS ALSO FEEDING MULTIPLE AREAS WHICH PER
 210.11B1 IS REQUIRED TO BE ON ONE OR MORE OF THE SMALL
 APPLIANCE CIRCUITS. THE KITCHEN, DINING ROOM ETC ALSO
 FEEDS LIVING ROOM, LIGHTS ETC./
 PLEASE SEE 210.52B1, 210.11C1, AND 220.53 FOR THE LOADS
 WHICH ARE REQUIRED TO BE FIGURED.
  
 8) NOTE: ALL AIC RATINGS MUST BE STATED ON PLANS.
 PLEASE KEEP IN MIND MANY OF THE FPL TRANSFORMERS ARE
 BEING UPDATED WHICH MAY HAVE A HIGHER AVAILABLE FAULT
 CURRENT. PLEASE BE SURE TO CHECK WITH THE LOCAL FPL
 REPRESENTATIVE.
  
 9) NOTE: PLEASE COORDINATE RISER AND PANELS. PANEL
 SCHEDULE FOR MAIN HOUSE IS LISTED AS 150AMP MCB YET
 RISER SHOWS COMPLETELY DIFFERENT EQUIPMENT.
 230.70, 230.71, 110.3 SECTIONS GIVEN AS GENERAL
 SECTIONS DUE TO MORE COORDINATION OF PLANS.
 FBC 106.1.1 FOR CLARITY.
  
 10) NOTE: PLEASE PROVIDE A RESPONSE FOR SCOPE OF WORK
 AT GUEST HOUSE/ COTTAGE. WILL THE NEW ELECTRICAL
 SERVICE BE THE ONLY WORK?
  
 11) NOTE: PLANS DO NOT INDICATE LOAD CALCULATIONS FOR
 SERVICE. PLEASE SEE NEC 220
 ONLY SHOWS LOAD FOR MAIN HOUSE.
  
  
  
  
  
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-09-22 Cont ID  
Sent By lmartine Date 2009-09-17 Time 11:06 Rev Time 0.00
Received By lmartine Date 2009-09-17 Time 11:05 Sent To  
Notes
2009-09-22 11:09:53GAVE TO MCDOUGAL, ROUTED ON 9/22

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-06-08 Cont ID  
Sent By mcruz Date 2009-06-08 Time 16:10 Rev Time 0.00
Received By mcruz Date 2009-06-04 Time 14:45 Sent To  
Notes
2009-06-04 14:46:41RESUB TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-04-30 Cont ID  
Sent By rregueir Date 2009-04-30 Time 15:55 Rev Time 0.00
Received By rregueir Date 2009-04-30 Time 15:54 Sent To  
Notes
2009-04-30 15:55:08R14

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-03-26 Cont ID  
Sent By adarroug Date 2009-03-26 Time 14:33 Rev Time 0.00
Received By adarroug Date 2009-03-26 Time 14:33 Sent To  
Notes
2009-03-26 14:37:37TO "RESIDENTIAL" R1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-14 Cont ID  
Sent By rmcdouga Date 2009-04-14 Time 11:07 Rev Time 0.00
Received By rmcdouga Date 2009-03-16 Time 16:34 Sent To  
Notes
2009-03-16 16:35:15TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2009-06-05 Cont ID  
Sent By rkussner Date 2009-06-05 Time 13:48 Rev Time 0.00
Received By rkussner Date 2009-06-05 Time 13:48 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-05-14 Cont ID  
Sent By rkussner Date 2009-05-14 Time 15:39 Rev Time 0.00
Received By rkussner Date 2009-05-14 Time 15:39 Sent To  
Notes
2009-05-14 16:02:06***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. SUBMIT A COST ESTIMATE BROKEN DOWN INTO UNIT COST
 THAT INCLUDES THE TOTAL COST OF ALL LANDSCAPE MATERIALS
 AND LABOR.
  
 2. THE OPEN AREA DOES NOT INCLUDE WALKWAYS, DRIVES,
 ETC. THE OPEN AREA FOR THIS HOME IS APPROXIMATELY 2755
 SQUARE FEET.. PURSUANT TO SECTION 94-442 (C), PALM
 TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35 PERCENT
 OF THE SHADE OR FLOWERING TREES REQUIRED BY THIS
 ARTICLE. THREE (3) TREES ARE REQUIRED AND ONLY ONE (1)
 PALM GROUPING CAN BE COUNTED IN MEETING THE TREE
 REQUIREMENT. AN ADDITIONAL SHADE OR FLOWERING TREE IS
 REQUIRED.
  
 3. IF UTILIZATION OF MOISTURE SENSING CONTROLLER OTHER
 THAN RAINSWITCH IS CREDITED TOWARD THE XERISCAPE DESIGN
 OPTIONS, PLEASE SPECIFY THE EQUIPMENT PROPOSED. ITEMS
 #2 AND 6 SHALL NOT BE CREDITED TOWARD MEETING THE
 XERISCAPE OPTIONS.
  
 4. IN KEEPING WITH XERISCAPE GUIDELINES, PALMS SHALL BE
 PLANTED TOGETHER IN GROUPINGS OF THREE (3) OR MORE AND
 UNDERPLANTED, INSTEAD OF BEING PLANTED SINGLE.
  
 5. IF THERE IS ANY LANDSCAPE AREA IN THE RIGHT-OF-WAY,
 SOD AND IRRIGATION IS REQUIRED.
  
 6. PLEASE SHOW ANY OVERHEAD LINES, UTILITIES, EASEMENTS
 AND ANYTHING ELSE ON THE LANDSCAPE PLAN THAT COULD
 INTERFERE WITH THE PROPOSED LANDSCAPING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2009-08-20 Cont ID  
Sent By rmcdouga Date 2009-08-20 Time 10:37 Rev Time 0.00
Received By rmcdouga Date 2009-08-20 Time 10:37 Sent To  
Notes
2009-08-20 10:37:47RESTAMPED PLAN

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2009-06-09 Cont ID  
Sent By rmcdouga Date 2009-06-09 Time 09:58 Rev Time 0.00
Received By rmcdouga Date 2009-06-09 Time 09:58 Sent To  
Notes
2009-06-09 10:01:57NO MECH PLANS SUBMITTED

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-03-27 Cont ID  
Sent By hmoser Date 2009-03-27 Time 13:16 Rev Time 0.00
Received By hmoser Date 2009-03-27 Time 13:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-04-08 Cont ID  
Sent By kstevens Date 2009-04-08 Time 14:24 Rev Time 0.00
Received By kstevens Date 2009-04-08 Time 14:24 Sent To  
Notes
2009-04-08 14:25:26PLUMBING WORK SHOWN IN 539 21ST ONLY.

Review Stop Z ZONING
Rev No 3 Status P Date 2009-06-08 Cont ID  
Sent By mcruz Date 2009-06-08 Time 16:10 Rev Time 0.00
Received By mcruz Date 2009-06-08 Time 16:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2009-05-15 Cont ID  
Sent By mcruz Date 2009-05-15 Time 11:26 Rev Time 0.00
Received By mcruz Date 2009-05-15 Time 11:08 Sent To  
Notes
2009-05-15 11:26:39PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PLEASE ADDRESS THE COMMENTS REGARDING THE LANDSCAPE
 PLAN FROM ROBERT KUSSNER, LANDSCAPE PLANNER.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 PLACED BACK ON RES RACK R14
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-03-18 Cont ID  
Sent By mcruz Date 2009-03-18 Time 19:40 Rev Time 0.00
Received By mcruz Date 2009-03-18 Time 19:39 Sent To I
Notes
2009-03-18 19:40:03PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK
 EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS
 "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  