Plan Review Details - Permit 09030300
Plan Review Stops For Permit 09030300 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-04-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-04-01 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2009-04-01 14:43:03 | PROVISO - ILLEGIBLE DETAILS SUBJECT TO INSPECTOR'S | | DISCRETION | | REVISION MAY BE REQUIRED | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-03-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-31 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-03-31 |
Time |
15:33 |
Sent To |
|
|
Notes |
2009-03-31 15:44:44 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 2. ON EITHER A FLOOR PLAN OR ELEVATIONS, SHOW LOCATION | | AND SCOPE OF REPAIR AREA(S). NOTE WHICH REPAIR DETAIL | | WILL BE USED IN EACH LOCATION. RATED AND UNRATED WALL | | SECTIONS WERE SUBMITTED. ON EITHER FLOOR PLANS OR | | ELEVATIONS SHOW ALL RATED WALLS WHICH WILL BE REPAIRED. | | FBC 6 AND FBC 7. | | | | PARTIALLY ADDRESSED. FLOOR PLAN/ELEVATION SUBMITTED, | | AREA OF WORK MARKED, BUT NOT CLEAR WHY PATIO/BALCONETTE | | DETAIL WAS SUBMITTED; DOES WORK AREA EXTEND INTO THE | | PATIO AREA? WHY DOESN'T THE PATIO WALL HAVE THE SAME | | FIRE RESISTANCE RATING AS THE OTHER EXTERIOR WALL? FBC | | CHAPTERS 5, 6, 7. | | | | 4. PLEASE PROVIDE LEGIBLE DETAILS. FOR INSTANCE, DETAIL | | MARKED 6 AD77, WINDOW HEAD DETAIL. | | | | DETAILS NOT LEGIBLE. THIS PERMIT CAN BE ISSUED WITH | | PROVISO, AT OWNER'S/CONTRACTOR'S RISK; SUBJECT TO FIELD | | INSPECTOR'S DISCRETION, REVISION CLARIFYING DETAILS MAY | | BE REQUIRED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-03-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-24 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-03-24 |
Time |
15:55 |
Sent To |
|
|
Notes |
2009-03-24 16:11:48 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. UL DETAIL PROVIDED DOES NOT MATCH THE CURRENT TESTED | | ASSEMBLY; PLEASE REVISE. THIS MAY BE AVAILABLE AT THE | | UL WEBSITE. | | | | 2. ON EITHER A FLOOR PLAN OR ELEVATIONS, SHOW LOCATION | | AND SCOPE OF REPAIR AREA(S). NOTE WHICH REPAIR DETAIL | | WILL BE USED IN EACH LOCATION. RATED AND UNRATED WALL | | SECTIONS WERE SUBMITTED. ON EITHER FLOOR PLANS OR | | ELEVATIONS SHOW ALL RATED WALLS WHICH WILL BE REPAIRED. | | FBC 6 AND FBC 7. | | | | 4. PLEASE PROVIDE LEGIBLE DETAILS. FOR INSTANCE, DETAIL | | MARKED 6 AD77, WINDOW HEAD DETAIL. | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-03-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-03-30 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-03-30 |
Time |
13:49 |
Sent To |
B |
|
Notes |
2009-03-30 13:49:42 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-03-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-24 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-03-13 |
Time |
16:22 |
Sent To |
|
|
Notes |
2009-03-13 16:22:44 | TO "MISC" BOX#1 |
|
|
|