Plan Review Details - Permit 09030208
Plan Review Stops For Permit 09030208
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-03-13 Cont ID  
Sent By jgomez Date 2009-03-13 Time 16:54 Rev Time 0.00
Received By jgomez Date 2009-03-13 Time 16:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-03-11 Cont ID  
Sent By jgomez Date 2009-03-11 Time 16:18 Rev Time 0.00
Received By jgomez Date 2009-03-11 Time 16:18 Sent To PC
Notes
2009-03-11 16:38:43RESIDENTIAL (R3) SHUTTERS, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE.
  
 1- AS OF MARCH 1ST 2009 THE NEW 2007 FBC IS IN EFFECT.
 PRODUCT APPROVAL FL7279 SUBMITTED IS FOR 2004 CODE
 VERSION. NEED TO PROVIDE PRODUCT APPROVAL FOR 2007 CODE
 VERSION.
  
 2- REVISE INSTALLATION SCHEDULE:
 A) ANCHOR SCHEDULE ON SHEETS 13 AND 14 OF SHUTTER
 DRAWINGS SUBMITTED ASSUMES 3-1/2" EDGE DISTANCE. EDGE
 DISTANCE SHOWN ON INSTALLATION SCHEDULE SUBMITTED
 SPECIFIES 3" EDGE DISTANCE. NEED TO REVISE ANCHOR
 SPACING AS REQUIRED BY TABLE ON SHEET 14 OF SHUTTERS
 DRAWINGS.
  
 B) SEE PRODUCT APPROVAL FOR SPECIFIC TYPE OF TAPCON TO
 BE USED AND SPECIFY EXACT SAME TYPE OF TAPCON AS
 REQUIRED TO MATCH PRODUCT APPROVAL.
  
 C) OPENING #1 CALLS FOR CONCRETE SUBSTRATE AT BOTTOM.
 PROVIDE PROOF THAT EXISTING CONCRETE HAS 3000 PSI
 STRENGTH AS REQUIRED BY NOTE #1 ON SHEET 14 OF SHUTTERS
 DRAWINGS SUBMITTED.
  
 D) COORDINATE SHUTTER SPAN IN COLUMN #6 WITH EDGE
 DISTANCE ON COLUMN #8 OF INSTALLATION SCHEDULE
 PROVIDED.
  
 E) REVISE INFORMATION ON TOP OF FORM. THIS IS A
 CONCRETE BLOCK HOUSE NOT CONCRETE. REVISE TYPE OF
 CONSTRUCTION ON TOP OF FORM. ALSO, REVISE NUMBER SHOWN
 ON PRODUCT COMPLIANCE REPORT. NUMBER SPECIFIED IS THE
 CONTRACTOR'S LICENSE NUMBER. NEED TO SPECIFY THE
 PRODUCT APPROVAL NUMBER.
  
 3- SPECIFY HOW COMPLYING WITH THE EMERGENCY EGRESS
 REQUIREMENTS OF SEC. R310.4 OF 2007 FLORIDA RESIDENTIAL
 CODE.
  
 4- PLEASE, IDENTIFY EACH OPENING ON THE KEY PLAN
 PROVIDED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-03-11 Cont ID  
Sent By jgomez Date 2009-03-11 Time 16:39 Rev Time 0.00
Received By jgomez Date 2009-03-11 Time 16:18 Sent To  
Notes
***NONE***