Plan Review Details - Permit 09020609
Plan Review Stops For Permit 09020609 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-04-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-04-17 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-04-17 |
Time |
08:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-04-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-04-16 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-04-16 |
Time |
16:43 |
Sent To |
|
|
Notes |
2009-04-16 16:46:39 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | FROM PREVIOUS LIST: | | | | 5. SHUTTER CONNECTION MOUNTING TYPE NOTED ON THE | | INSTALLATION SCHEDULE IS "12"; THIS DOES NOT CORRELATE | | WITH THE ANCHOR CHARTS ON SHEET 3. THE CONNECTION TYPE | | SHOULD BE ONE INCLUDED ON THE ANCHOR CHARTS; C1 THROUGH | | C5. | | | | NOT ADDRESSED; PLEASE REVISE. SEE SHEET 3. | | | | NEW COMMENT: | | | | BASED ON THE DESIGN PRESSURE (53.24 SO MUST USE THE ROW | | FOR -63) AND SUBSTRATE (BLOCK AS STATED BY CONTRACTOR) | | EITHER 11" OR 6" SPACING REQUIRED DEPENDING ON WHICH | | SHUTTER CONNECTION MOUNTING TYPE IS USED, NOT 12". | | PLEASE REVISE. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-03-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-02 |
Time |
13:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-03-02 |
Time |
13:21 |
Sent To |
|
|
Notes |
2009-03-02 13:58:46 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. ONLY TWO OPENINGS ARE SHOWN AS PROTECTED ON THE | | INSTALLATION SCHEDULE, BUT THE FLOOR PLAN SHOWS 5 | | OPENINGS. | | | | 2. ONE OF THE OPENINGS ON THE INSTALLATION SCHEDULE | | DOES NOT INCLUDE THE OPENING SIZE. | | | | 3. THE OPENINGS ON THE FLOOR PLAN SHOULD BE NUMBERED, | | TO CORRELATE WITH THE OPENINGS ON THE INSTALLATION | | SCHEDULE. | | | | 4. THE FASTENER SPECIFIED, ELCO TAPCON, IS NOT AN | | OPTION IN THE PRODUCT APPROVAL SUBMITTED, SEE SHEET 3. | | ENGINEERING WOULD BE REQUIRED TO USE FASTENERS OTHER | | THAN THOSE TESTED/ENGINEERED IN THE PRODUCT APPROVAL. | | | | 5. SHUTTER CONNECTION MOUNTING TYPE NOTED ON THE | | INSTALLATION SCHEDULE IS "12"; THIS DOES NOT CORRELATE | | WITH THE ANCHOR CHARTS ON SHEET 3. THE CONNECTION TYPE | | SHOULD BE ONE INCLUDED ON THE ANCHOR CHARTS; C1 THROUGH | | C5. | | | | 6. NOTE THAT ONLY TWO FASTENER TYPES ALLOWED FOR 2" | | EDGE DISTANCE, SEE SHEET 3 OF THE PRODUCT APPROVAL. | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2009-02-27 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2009-02-27 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2009-02-27 |
Time |
13:20 |
Sent To |
|
|
Notes |
2009-02-27 13:21:07 | HISTORIC APPROVED BY JPAPA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-03-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-02 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-04-17 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
|