Plan Review Details - Permit 09020579
Plan Review Stops For Permit 09020579
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-02 Cont ID  
Sent By shill Date 2009-04-02 Time 17:06 Rev Time 0.00
Received By shill Date 2009-04-02 Time 17:06 Sent To  
Notes
2009-04-02 17:27:23****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PROVIDE DIMENSIONS OF PROPOSED SHED TO PROPERTY
 LINES, FBC601.
  
 2. DECLARE OCCUPANCY CLASSIFICATION, FBC CHAPTER 3. THE
 SHED PLANS DECLARE THIS STRUCTURE AS RESIDENTIAL LAWN
 STORAGE; THIS DOES NOT APPEAR TO BE APPLICABLE FOR THIS
 PROJECT.
  
 3. DECLARE OCCUPANT LOAD, FBC CHAPTER 10.
  
 4. PLANS SHOW THIS AS ONE PARCEL; PAPA SHOWS THIS AS
 THREE SEPARATE PARCELS. IF THIS IS THE CASE, EACH
 PARCEL SHOULD HAVE A SEPARATE PERMIT (OTHERWISE, PLEASE
 PROVIDE EVIDENCE THAT THESE THREE PARCELS HAVE BEEN
 COMBINED INTO ONE PARCEL). PLEASE SEE COMMENT 1; THIS
 WOULD BE APPLICABLE TO THE PROPERTY LINE OF THE PARCEL
 ON WHICH THE SHED WILL BE LOCATED, NOT THE ADJACENT
 PARCEL INCLUDED IN THIS PROJECT.
  
 5. PROVIDE A DETAIL FOR THE PROPOSED WALL.
  
 6. SHOW ACCESSIBLE ROUTE AS DESCRIBED IN
 FBC11-4.1.2(1), INCLUDING ACCESSIBILITY AT THE BUILDING
 ENTRANCE.
  
 7. SEE COMMENT 4. FBC1002, SEE DEFINITION OF EXIT AND
 PUBLIC WAY. IT APPEARS THAT NO EXITING TO THE PUBLIC
 WAY IS PROVIDED FROM THE PROPOSED STRUCTURE WITHOUT
 CROSSING OVER OTHER PARCELS. PLEASE ADDRESS.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-03-26 Cont ID  
Sent By dpalmer Date 2009-03-26 Time 16:49 Rev Time 0.00
Received By dpalmer Date 2009-03-26 Time 16:49 Sent To  
Notes
2009-03-26 16:49:42** DENIED REVIEW **
  
 1) NOTE: PLEASE SEE THE ADDRESS LOCATION ON PLANS NEEDS
 TO CORRELATE WITH THE LOCATION AS APPLIED. THE PLANS
 CALL FOR AVON RD. HOWEVER ACTUAL LOCATION IS 425
 BELVEDERE RD.
  
 2) NOTE: RISER INDICATES AN EQUIPMENT GROUNDING
 CONDUCTOR FROM METER TO MAIN. THIS IS NOT PERMITTED PER
 250.6,250.24
  
 3) NOTE: THE SUBMITTED LOAD CALCULATIONS DO NOT MEET
 THE MINIMUM NEC 220 REQUIREMENTS. PLEASE SEE NEC
 220.12,220.14,220.44, 220.42 ETC
 PLEASE ALSO BE SURE TO SEE 215.3,230.42 ETC FOR ALL
 CONTINUOUS LOADS WHICH ARE REQUIRED TO BE SHOWN AT
 125%.
  
 3) NOTE: PLEASE BE SURE TO COORDINATE THE PANEL
 SCHEDULE AND LOAD CALCULATIONS. SOME EXAMPLES OF ITEMS
 WHICH DO NOT COORDINATE IS POOL PUMP, WATER COOLER/
 BOTH DO THESE ARE NOT ON PANEL SCHEDULES. SOME ITEMS ON
 SCHEDULE NOT IN LOAD CALCULATIONS ARE SPRINKLER PUMP.
 408.4, 220.
  
 4) NOTE: PLEASE SEE SOME LIGHTS ON PLANS NOT ON ANY
 CONTROL OR CIRCUIT. THIS WAS REDLINED ON ONE COPY.
 PLEASE SEE 408.4, 310.16, 220 ETC FOR MINIMUMS.
  
 5) NOTE: PLEASE SEE FBC 13-415.1.ABC.1.4 FOR REQUIRED
 EXTERIOR LIGHTING CONTROLS. MAY NOT USE STANDARD SINGLE
 POLE SWITCHES.
  
 6) NOTE: PLEASE PROVIDE PRESCRIPTIVE SPACE PERFORMANCE
 LEVELS PER 13-415.2.ABC.1.1, .1.2. PLEASE SEE
 13-415.2.B.2 FOR EXTERIOR OF BUILDING PERFORMANCE
 LEVELS.
  
 7) NOTE: PLEASE PROVIDE INFORMATION ON WHAT THE *E* ON
 THE PLANS IS. THIS IS LOCATED ON THE SHED PLANS. IS
 THIS AN EXIT SIGN?
 IF SO THE SYMBOL LEGEND DOES NOT INDICATE THIS SYMBOL
 AND THERE IS NOT CIRCUIT SHOWN. PLEASE SEE 700.12F FOR
 CIRCUITING IF INDEED AN EXIT SIGN OR SOME SORT.
  
 8) NOTE: PLEASE PROVIDE AIC RATINGS FOR ALL EQUIPMENT
 PER 110.9. ALL SERVICE EQUIPMENT AND BREAKERS SHALL BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
  
 9) NOTE: PLEASE PROVIDE THE OCCUPANCY CLASSIFICATION
 PER CHAPTER 3 OF THE FBC.
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-04-14 Cont ID  
Sent By mawillia Date 2009-04-14 Time 10:15 Rev Time 0.00
Received By mawillia Date 2009-04-14 Time 09:13 Sent To  
Notes
2009-04-14 10:01:40*****UNSAT*****
  
 1. THE PROJECT SITE ADDRESS SHALL BE IN THE TITLE BLOCK
 OF EACH SUBMITTED PLAN SHEET.
  
 2. DISPLAY/SHOW THE NUMERICAL ADDRESS OF THE BUILDING
 ON THE APPROPIATE EXTERIOR ELEVATION VISIBLE FROM
 BELVEDERE ROAD. AS PER WEST PALM BEACH CODE, THE
 ADDRESS NUMBERS SHALL BE NO LESS THAN 6" IN HEIGHT AND
 NO LESS THAN 1" IN WIDTH/STROKE. IN THE EVENT THAT THE
 VISIBILITY OF THE ADDRESS IS NOT PLAINLY VISIBLE FROM
 THE ROADWAY, A MARKEE AND/OR SIGN POST WITH THE ADDRESS
 WILL BE REQUIRED IN ADDITION TO THE ADDRESS ON THE
 BUILDING.
  
 3. LANDSCAPING AND THE LIKE SUCH OPERATIONS SHALL NOT
 OBSTRUCT A FIRE HYDRANT OR FIRE PROTECTION APPLIANCE
 AND HINDER OR PREVENT ITS IMMEDIATE USE BY THE FIRE
 PERSONNEL. SUCH FIRE HYDRANT OR FIRE PROTECTION
 APPLIANCE SHALL BE MAINTAINED READILY VISIBLE AT ALL
 TIMES.
  
 4. SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHER LOCATED INSIDE THE STRUCTURE.
  
 5. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE
 REFERENCED.
  
 6. BASED ON THE ASSUMPTION THAT THIS STRUCTURE IS A
 STORAGE OCCUPANCY, CLASSIFY THE MATERIALS TO BE STORED
 AS LOW HAZARD, ORDINARY HAZARD, OR HIGH HAZARD.
  
 7. ON SHEET A04, A SMOKE DETECTOR (SD) IS SHOWN IN THE
 ELECTRICAL FLOOR PLAN. IS THIS DEVICE A SMOKE DETECTOR
 OR A SMOKE ALARM (SA)? PLEASE BE ADVISED THAT A SMOKE
 DETECTOR IS TIED TO THE BUILDING'S FIRE ALARM SYSTEM
 WHEREAS A SMOKE DETECTOR ALERTS THE OCCUPANT(S) ONLY
 AND IS NOT TIED INTO A FIRE ALARM SYSTEM.
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHER E EACH COMMENT WAS ADDRESSED.
  
 CAPT MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-17 Cont ID  
Sent By hmoser Date 2009-04-17 Time 09:55 Rev Time 0.00
Received By hmoser Date 2009-02-27 Time 16:31 Sent To  
Notes
2009-02-27 16:35:01TO "COMM" BD#46

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-03-11 Cont ID  
Sent By rkussner Date 2009-03-11 Time 15:47 Rev Time 0.00
Received By rkussner Date 2009-03-11 Time 11:40 Sent To PC
Notes
2009-03-11 16:55:25***LANDSCAPE REVIEW FAILED***
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. PURSUANT TO SECTION 94-442(A), LANDSCAPE PLANS SHALL
 BE SIGNED AND SEALED BY A REGISTERED LANDSCAPE
 ARCHITECT.
  
 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS.
  
 3. PURSUANT TO SECTION 94-442 (B)(1), AT LEAST ONE
 FLOWERING TREE SHALL BE PLANTED FOR EACH 6400 SQUARE
 FEET OF OPEN SPACE OR PORTION THEREOF.
  
 4. PLEASE BE SPECIFIC AS TO WHAT TREES AND PLANT
 MATERIAL ARE BEING PROPOSED. COCONUT PALMS ARE NOT IN
 THE SAME CLASSIFICATION AS SABAL PALMS. JASMINE IS NOT
 A HEDGE AND SO ON.
  
 5. PURSUANT TO SECTION 94-443(C)(3)(A), EACH ROW OF
 PARKING SPACES SHALL BE TERMINATED BY LANDSCAPED
 ISLANDS OF NOT LESS THAN FIVE FEET IN WIDTH AND LOT
 LESS THAN THE LENGTH OF THE ADJACENT PARKING STALL. THE
 ISLAND AT THE NORTH END OF THE PARKING ROW IS NOT THE
 FULL LENGTH OF THE ADJACENT PARKING STALL.
  
 6. UNLESS THE TRAVEL AISLE IS ONE-WAY ONLY, 90 DEGREE
 PARKING IS PREFERRED.
  
 7. PURSUANT TO SECTION 94-443(C)(4), FOR OTHER PAVED
 AREAS UTILIZED BY MOTOR VEHICLES, INCLUDING AISLES,
 ADDITIONAL LANDSCAPING SHALL BE PROVIDED AS FOLLOWS:
 FOUR SQUARE FEET OF LANDSCAPED AREA SHALL BE REQUIRED
 FOR EACH 100 SQUARE FEET OR FRACTION THEREOF.
  
 8. PURSUANT TO SECTION 94-443(C)(5)(A), LANDSCAPE AREAS
 SHALL BE SEPARATED FROM VEHICULAR USE AREAS BY
 NONMOUNTABLE, CONCRETE CURBING OF THE TYPE
 CHARACTERIZED AS "TYPE D". CURBING WAS NOT SHOWN ALONG
 THE EAST SIDE OF THE DRIVE AISLE, ADJACENT TO THE
 POTTED PLANTS.
  
 9. THE PAVED AREA BETWEEN THE DRIVE AISLE AND THE SHED
 IS DESIGNATED AS A LANDSCAPED AREA ON THE SITE PLAN.
 PLEASE CLARIFY. POTTED PLANTS CANNOT BE USED TO DEFINE
 A DRIVEWAY.
  
 10. ON THE LANDSCAPE PLAN, PLEASE SHOW ALL UTILITIES,
 EASEMENTS, STREET LIGHTS AND TREES ON NEIGHBORING
 PROPERTY IN CLOSE PROXIMITY TO SHARED PROPERTY LINES
 AND ANYTHING ELSE THAT MAY INTERFERE WITH THE PROPOSED
 LANDSCAPING.
  
 11.THERE ARE PROPOSED LIVE OAK TREES UNDER POWER LINES,
 YOU ARE REQUIRED TO FOLLOW FPL'S "PLANT THE RIGHT TREE
 IN THE RIGHT PLACE" GUIDELINES FOR WHAT IS ALLOWED TO
 BE PLANTED NEAR OF UNDER POWER LINES. THE GUIDELINES
 WOULD NOT ALLOW THE OAKS TO BE PLANTED IN THAT
 LOCATION.
  
 12. FOR THIS TO BE UTILIZED AS ONE-WAY CIRCULATION, IT
 MUST BE STRIPED AND MARKED ACCORDINGLY PER CITY
 STANDARDS.
  
 13. PURSUANT TO SECTION 94-442(D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED.
  
 14. PURSUANT TO SECTION 94-445(4)(G)(3), AUTOMATIC
 IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED
 LANDSCAPE AREAS FOR ALL PROPERTIES. THIS INCLUDES THE
 RIGHT-OF-WAY, ADJACENT TO AVON ROAD.
  
 15. SUBMIT A CERTIFIED COST ESTIMATE THAT INCLUDES THE
 TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR.
  
 16. HEDGE MATERIAL ADJACENT TO A RIGHT-OF-WAY SHALL BE
 PLANTED ALONG THE INTERIOR PERIMETER TO THE LANDSCAPE
 SETBACK (ON STREET SIDE OF A FENCE) . GROUND COVER AND
 SOD SHALL BE PLANTED BETWEEN THE HEDGE AND THE PROPERTY
 LINE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2009-04-17 Cont ID  
Sent By hmoser Date 2009-04-17 Time 09:55 Rev Time 0.00
Received By hmoser Date 2009-04-17 Time 09:55 Sent To  
Notes
2009-04-17 09:57:05PERMIT NOT REQUIRED .

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-04-14 Cont ID  
Sent By kstevens Date 2009-04-14 Time 11:35 Rev Time 0.00
Received By kstevens Date 2009-04-14 Time 11:35 Sent To  
Notes
2009-04-14 11:52:02DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. PLANS SHALL INDICATE THE LOCATION OF THE WORK IN THE
 TITLE BLOCK. THE ADDRESS INDICATED ON THE APPLICATION
 AND IN THE CITY ADDRESSING SYSTEM IS 425 BELVEDERE
 ROAD. SECTION 106.1.1
  
 2. SUBMIT A SITE PLAN INDICATING THE LOCATION OF THE
 SEWER CONNECTION, THE WATER METER, THE BACKFLOW, THE
 SEWER PIPING & THE WATER SERVICE LINE. SECTIONS 106.1.2
 (MORE INFORMATION REQUIRED), 603, 701, 708, ETC.
  
 3. PER TABLE 403.1 A SERVICE SINK IS REQUIRED IN ALL
 STORAGE OCCUPANCIES. PLEASE INDICATE THE LOCATION OF
 THE REQUIRED SINK.
  
 4. SHOW COMPLIANCE FOR THE FOLLOWING:
  
 ___W/C:
 A. 11-4.16.2 CLEAR FLOOR SPACE
 B. 11-4.16.4 GRAB BARS (MINIMUM 36" REQUIRED BEHIND THE
 W/C - 30" SHOWN)
  
 ___LAV:
 A. 11-4.19.2 HEIGHT & CLEARANCES
 B. 11-4.19.3 CLEAR FLOOR SPACE
 C. 11-4.19.4 EXPOSED PIPES & SURFACES
 D. 11-4.19.5 FAUCETS
  
 ___D/F:
 A. 11-4.15.5 CLEAR FLOOR SPACE (FORWARD APPROACH REQD)
 B. 11-4.1.3(10(A) PROVISIONS FOR THOSE WHO HAVE
 DIFFICULTY BENDING OR STOOPING.
  
 5. SHT 4 OF 4 SANITARY RISER DIAGRAM, A TWO WAY
 CLEANOUT SHALL BE USED NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER, OR A SEPARATE
 CLEANOUT FOR THE SEWER IS REQUIRED. SECTION 708.3.2.
  
 6. A WATER ISOMETRIC RISER DIAGRAM IS REQUIRED PER
 SECTION 106.3.5.1.3. INDICATE ALL PIPE SIZES, VALVES,
 ETC.
  
 7. HOT WATER IS REQUIRED FOR THE SERVICE SINK PER
 SECTION 607.1. PLEASE SHOW ON THE FLOOR PLAN AND THE
 WATER ISOMETRIC RISER DIAGRAM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-03-10 Cont ID  
Sent By jroach Date 2009-03-10 Time 20:31 Rev Time 0.00
Received By jroach Date 2009-03-10 Time 20:31 Sent To  
Notes
2009-03-10 21:17:21ZONING PLAN REVIEW
  
 PERMIT NO.: 09020579
 ADDRESS: 425 BELVEDERE ROAD
 CONTRACTOR/CONTACT: ROBERT BROCKMAN
 TELEPHONE NO.: 561.719.3702
 SCOPE OF REVIEW: INSTALLATION OF PRE-FABRICATED SHED
 AND RELATED SITE IMPROVEMENTS.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY SHALL BE
 PROVIDED; ONLY ONE (1) COPY WAS SUBMITTED WITH THE
 PERMIT APPLICATION.
  
 2) SETBACK DIMENSIONS SHALL BE PROVIDED FROM ALL
 PROPERTY LINES TO THE EXTERIOR OF THE PROPOSED
 PRE-FABRICATED SHED. ALL SETBACKS SHALL CONFORM TO THE
 GENERAL COMMERCIAL (GC) ZONING DESIGNATION.
  
 3) PLEASE CLARIFY THE CALCULATIONS PROVIDED IN THE SITE
 DATA TABLE. IMPERVIOUS AREA AND LANDCAPE ARE SHOULD
 EQUAL 100%. ADDITIONALLY, THE PERCENTAGE OF OPEN SPACE
 (LOT AREA MINUS BLDG. FOOTPRINT) SHALL BE PROVIDED.
  
 4) PURSUANT TO SECTION 94-401 OF THE CITY'S ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDRS), THE EXISTING SIGN
 POLES SHALL BE REMOVED.
  
 5) ELEVATIONS OF THE PROPOSED SHED SHALL BE PROVIDED
 SHOWING THE OVERALL HEIGHT OF THE STRUCTURE. BUILDING
 HEIGHT SHALL BE MEASURED FROM GRADE TO THE MEAN POINT
 OF A PITCHED ROOF. THE PRODUCT APPROVALS SUBMITTED AS
 PART OF THE PERMIT APPLICATION DO NOT SHOW THE OVERALL
 HEIGHT IN THE DRAWINGS.
  
 6) A DETAIL OF THE PROPOSED FENCE/GATE SHALL BE
 PROVIDED.
  
 7) PLEASE INDICATE THE LOCATION OF ANY PROPOSED
 MECHANICAL EQUIPMENT. PURSUANT TO SECTION 94-444, ALL
 MECHANICAL EQUIPMENT SHALL BE SCREENED. SCREENING SHALL
 CONSIST OF BRICK, DECORATIVE CONCRETE, OTHER DECORATIVE
 MASONRY, OR COMPARABLY DURABLE WOOD OR STEEL.
 ADDITIONALLY, SHRUBS OR HEDGES SHALL BE PLANTED AT
 2-FOOT INTERVALS.
  
 8) AN APPROVED TRAFFIC CONCURRECY LETTER FROM THE PALM
 BEACH COUNTY DEPARTMENT OF ENGINEERING AND PUBLIC WORKS
 - TRAFFIC ENGINEERING DIVISION SHALL BE SUBMITTED WITH
 THE PERMIT APPLICATION.
  
 9) THE PROPOSED SITE PLAN ON SHEET A01 NEEDS TO BE
 ADJUSTED. THERE IS AN AREA LABELED AS "LANDSCAPE AREA"
 BUT IS SHADED AS "AREA CURRENTLY PAVED." ADDITIONALLY,
 THE LABEL "APPLIED STRIPES AS PER ADA" IS NOT POINTED
 AT ANYTHING. PLEASE ADJUST PLAN ACCORDINGLY.
  
 10) PURSUANT TO SECTION 94-448(D)(2)(R), LANDSCAPE
 PLANS SHALL BE PREPARED BY A REGISTERED LANDSCAPE
 ARCHITECT. ADDITIONALLY, REFER TO SECTION 94-448(D)(2)
 REGARDING MINIMUM REQUIREMENTS OF THE LANDSCAPE PLANS.
  
 11) PLEASE PROVIDE WRITTEN CONFIRMATION FROM THE CITY'S
 ENGINEERING SERVICES DEPARTMENT THAT A DUMPSTER IS NOT
 REQUIRED. IF A DUMPSTER IS REQUIRED, IT SHALL BE
 SCREENED IN ACCORDANCE WITH SECTION 94-444 OF THE
 ZLDRS.
  
 12) A PARKING DETAIL SHALL BE PROVIDED SHOWING
 COMPLIANCE OF THE STRIPING (SEE ATTACHED).
  
 13) THE AISLE WIDTH OF THE PARKING AREA SHALL BE
 DIMENSIONED AND SHALL BE A MINIMUM OF 13 FEET.
  
 14) BICYCLE PARKING SHALL BE PROVIDED AT A RATE OF 1
 SPACE PER 20 PARKING SPACES, OR FRACTION THEREOF.
 PLEASE REFER TO THE ATTACHED DOCUMENTATION REGARDING
 STYLE AND PLACEMENT OF BIKE RACKS.
  
 15) A DATA TABLE SHOWING THE PARKING CALCULATIONS SHALL
 BE PROVIDED ON THE SITE PLAN.
  
 REMINDER, THE NURSERY IS TO BE FOR RETAIL SALES ONLY OF
 MATERIAL GROWN OFF-SITE....NO PLANTS ARE TO BE GROWN ON
 THE PROPERTY.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.
  