Plan Review Details - Permit 09020476
Plan Review Stops For Permit 09020476
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2010-09-08 Cont ID  
Sent By jwitmer Date 2010-09-08 Time 09:39 Rev Time 0.77
Received By jwitmer Date 2010-09-08 Time 09:39 Sent To  
Notes
2010-09-08 09:44:00BUILDING PLAN REVIEW
 PERMIT: 09020476
 ADD: 455 HIBISCUS STREET- FOUNDATION PERMIT
 CONT: MOSS & ASSOCIATES LLC
 TEL: (954)444-0933
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 ARCHITECT: DONALD T. YOSHINO, AIA
 STRUCTURAL ENGINEER: JOEL MIDDLEBROOKS, P.E.
  
 SEPT. 08/2010
  
 1) INFORMATIONAL ONLY: THRESHOLD INSPECTOR: WPB
 AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES
 DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL
 INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA
 STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS
 CODE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER
 INFORMATION BEFORE THE PERMIT MAY BE ISSUED. COPIES OF
 THE SPECIAL INSPECTOR AGREEMENT ARE INCLUDED WITHIN
 THIS REVIEW.
  
  
 2) BUILDING PROVISO: AS PER CONVERSATION IN A
 PRE-CONSTRUCTION MEETING WITH THE DESIGNERS AND
 CONTRACTOR SOILS TO THE EAST OF THE PROJECT UNDER THE
 EXISTING BUILDING MUST BE STABILIZED BEFORE THE
 DIGGING.
 3304.1.2 SURCHARGE. NO FILL OR OTHER SURCHARGE LOADS
 SHALL BE PLACED ADJACENT TO ANY BUILDING OR STRUCTURE
 UNLESS SUCH BUILDING OR STRUCTURE IS CAPABLE OF
 WITHSTANDING THE ADDITIONAL LOADS CAUSED BY THE FILL OR
 SURCHARGE. EXISTING FOOTINGS OR FOUNDATIONS WHICH CAN
 BE AFFECTED BY ANY EXCAVATION SHALL BE UNDERPINNED
 ADEQUATELY OR OTHERWISE PROTECTED AGAINST SETTLEMENT
 AND SHALL BE PROTECTED AGAINST LATER MOVEMENT.
 3307.1 PROTECTION REQUIRED. ADJOINING PUBLIC AND
 PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE DURING
 CONSTRUCTION, REMODELING AND DEMOLITION WORK.
 PROTECTION MUST BE PROVIDED FOR FOOTINGS, FOUNDATIONS,
 PARTY WALLS, CHIMNEYS, SKYLIGHTS AND ROOFS. PROVISIONS
 SHALL BE MADE TO CONTROL WATER RUNOFF AND EROSION
 DURING CONSTRUCTION OR DEMOLITION ACTIVITIES. THE
 PERSON MAKING OR CAUSING AN EXCAVATION TO BE MADE SHALL
 PROVIDE WRITTEN NOTICE TO THE OWNERS OF ADJOINING
 BUILDINGS ADVISING THEM THAT THE EXCAVATION IS TO BE
 MADE AND THAT THE ADJOINING BUILDINGS SHOULD BE
 PROTECTED. SAID NOTIFICATION SHALL BE DELIVERED NOT
 LESS THAN 10 DAYS PRIOR TO THE SCHEDULED STARTING DATE
 OF THE EXCAVATION.
  
 3) NOTE AN ELECTRIAL CONTRACTOR WILL NEED TO BE SIGNED
 ON (PERMITTED) FOR BONDING/ GROUNDING BEFORE STEEL
 INSPECTION.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-06-18 Cont ID  
Sent By jwitmer Date 2009-06-18 Time 10:03 Rev Time 2.22
Received By jwitmer Date 2009-06-17 Time 11:32 Sent To  
Notes
2009-06-17 12:04:45THRESHOLD INSPECTION PLAN LOCATED ON S0.04
  
 BUILDING PROVISO: AS PER CONVERSATION IN A
 PRE-CONSTRUCTION MEETING WITH THE DESIGNERS AND
 CONTRACTOR SOILS TO THE EAST OF THE PROJECT UNDER THE
 EXISTING BUILDING MUST BE STABALIZIED BEFORE THE
 DIGGING.
 3304.1.2 SURCHARGE. NO FILL OR OTHER SURCHARGE LOADS
 SHALL BE PLACED ADJACENT TO ANY BUILDING OR STRUCTURE
 UNLESS SUCH BUILDING OR STRUCTURE IS CAPABLE OF
 WITHSTANDING THE ADDITIONAL LOADS CAUSED BY THE FILL OR
 SURCHARGE. EXISTING FOOTINGS OR FOUNDATIONS WHICH CAN
 BE AFFECTED BY ANY EXCAVATION SHALL BE UNDERPINNED
 ADEQUATELY OR OTHERWISE PROTECTED AGAINST SETTLEMENT
 AND SHALL BE PROTECTED AGAINST LATERAL MOVEMENT.
 3307.1 PROTECTION REQUIRED. ADJOINING PUBLIC AND
 PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE DURING
 CONSTRUCTION, REMODELING AND DEMOLITION WORK.
 PROTECTION MUST BE PROVIDED FOR FOOTINGS, FOUNDATIONS,
 PARTY WALLS, CHIMNEYS, SKYLIGHTS AND ROOFS. PROVISIONS
 SHALL BE MADE TO CONTROL WATER RUNOFF AND EROSION
 DURING CONSTRUCTION OR DEMOLITION ACTIVITIES. THE
 PERSON MAKING OR CAUSING AN EXCAVATION TO BE MADE SHALL
 PROVIDE WRITTEN NOTICE TO THE OWNERS OF ADJOINING
 BUILDINGS ADVISING THEM THAT THE EXCAVATION IS TO BE
 MADE AND THAT THE ADJOINING BUILDINGS SHOULD BE
 PROTECTED. SAID NOTIFICATION SHALL BE DELIVERED NOT
 LESS THAN 10 DAYS PRIOR TO THE SCHEDULED STARTING DATE
 OF THE EXCAVATION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-06-03 Cont ID  
Sent By jwitmer Date 2009-06-03 Time 15:00 Rev Time 1.50
Received By jwitmer Date 2009-06-03 Time 13:30 Sent To  
Notes
2009-06-03 14:29:30BUILDING PLAN REVIEW
 PERMIT: 09020476
 ADD: 455 HIBISCUS STREET- FOUNDATION PERMIT
 CONT: MOSS & ASSOCIATES LLC
 TEL: (954)444-0933
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 ARCHITECT: DONALD T. YOSHINO, AIA
 STRUCTURAL ENGINEER: JOEL MIDDLEBROOKS, P.E.
  
 JUNE 03/ 2009
 2ND REVIEW
 ACTION: REVIEWED
  
 1) INFORMATIONAL ONLY: THE REMAINDER OF THE PERMIT AND
 STATE RADON FEES ARE TO BE PAID BEFORE THE ISSUANCE OF
 THE FOUNDATION PERMIT.
  
 2)INFORMATIONAL ONLY: BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY. THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED
 BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED
 TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025
 FOR MORE INFORMATION.
  
 3) INFORMATIONAL ONLY: THRESHOLD INSPECTOR: WPB
 AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES
 DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL
 INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA
 STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS
 CODE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER
 INFORMATION BEFORE THE PERMIT MAY BE ISSUED. COPIES OF
 THE SPECIAL INSPECTOR AGREEMENT ARE INCLUDED WITHIN
 THIS REVIEW.
  
 4) BUILDING PROVISO: AS PER CONVERSATION IN A
 PRE-CONSTRUCTION MEETING WITH THE DESIGNERS AND
 CONTRACTOR SOILS TO THE EAST OF THE PROJECT UNDER THE
 EXISTING BUILDING MUST BE STABALIZIED BEFORE THE
 DIGGING.
 3304.1.2 SURCHARGE. NO FILL OR OTHER SURCHARGE LOADS
 SHALL BE PLACED ADJACENT TO ANY BUILDING OR STRUCTURE
 UNLESS SUCH BUILDING OR STRUCTURE IS CAPABLE OF
 WITHSTANDING THE ADDITIONAL LOADS CAUSED BY THE FILL OR
 SURCHARGE. EXISTING FOOTINGS OR FOUNDATIONS WHICH CAN
 BE AFFECTED BY ANY EXCAVATION SHALL BE UNDERPINNED
 ADEQUATELY OR OTHERWISE PROTECTED AGAINST SETTLEMENT
 AND SHALL BE PROTECTED AGAINST LATER MOVEMENT.
 3307.1 PROTECTION REQUIRED. ADJOINING PUBLIC AND
 PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE DURING
 CONSTRUCTION, REMODELING AND DEMOLITION WORK.
 PROTECTION MUST BE PROVIDED FOR FOOTINGS, FOUNDATIONS,
 PARTY WALLS, CHIMNEYS, SKYLIGHTS AND ROOFS. PROVISIONS
 SHALL BE MADE TO CONTROL WATER RUNOFF AND EROSION
 DURING CONSTRUCTION OR DEMOLITION ACTIVITIES. THE
 PERSON MAKING OR CAUSING AN EXCAVATION TO BE MADE SHALL
 PROVIDE WRITTEN NOTICE TO THE OWNERS OF ADJOINING
 BUILDINGS ADVISING THEM THAT THE EXCAVATION IS TO BE
 MADE AND THAT THE ADJOINING BUILDINGS SHOULD BE
 PROTECTED. SAID NOTIFICATION SHALL BE DELIVERED NOT
 LESS THAN 10 DAYS PRIOR TO THE SCHEDULED STARTING DATE
 OF THE EXCAVATION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-03-04 Cont ID  
Sent By jwitmer Date 2009-03-04 Time 11:59 Rev Time 6.00
Received By jwitmer Date 2009-03-04 Time 09:35 Sent To  
Notes
2009-03-04 13:30:12BUILDING PLAN REVIEW
 PERMIT: 09020476
 ADD: 455 HIBISCUS STREET- FOUNDATION PERMIT
 CONT: MOSS & ASSOCIATES LLC
 TEL: (954)444-0933
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 ARCHITECT: DONALD T. YOSHINO, AIA
 STRUCTURAL ENGINEER: JOEL MIDDLEBROOKS, P.E.
  
 1ST REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) PLEASE SUBMIT 3 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT. YOUR PROJECT WILL REQUIRE A
 THRESHOLD INSPECTOR (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTS WEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1D) : PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.SHEET GN1 DOES
 INCLUDE THE 2004 FBC BUT NOT THE SUPPLEMENTS. THE OTHER
 ISSUE IS THE PLANS ALSO INDICATE THE 2004 FBC EXISTING
 BUILDING CODE WHICH WOULD NOT BE APPLICABLE SINCE THIS
 IS NEW CONSTRUCTION.
 PLEASE UPDATE SHEET S0.01 THE 2004 FBC TO INCLUDE THE
 2007 SUPPLE
 2) THRESHOLD BUILDING REQUIREMENTS:
  
 2A) SEMI-COMPLIED. 109.3.6.1 THE ENFORCING AGENCY SHALL
 REQUIRE A SPECIAL INSPECTOR TO PERFORM STRUCTURAL
 INSPECTIONS ON A THRESHOLD BUILDING PURSUANT TO A
 WRITTEN STRUCTURAL INSPECTION PLAN PREPARED BY THE
 ENGINEER OF RECORD. THE (WRITTEN) STRUCTURAL INSPECTION
 PLAN MUST BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO
 THE ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION
 OF A THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL
 INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION
 PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE
 ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED
 DOCUMENTS.
  
 SHEET S0.04 DOES HAVE A THRESHOLD INSPECTION PLAN FOR
 THE FOUNDATION AND FIRST LIFT, THE ISSUE IS THERE IS NO
 INFORMATION FOR THE REQUIRED AUGER CAST PILE, THERE ARE
 NOTES ON S0.02 FOR AUGER CAST PILE BUT WERE NOT
 INCLUDED UNDER THE THRESHOLD INSPECTION PLAN. FOR THE
 COMPLETE BUILDING PERMIT INSPECTION INFORMATION FOR THE
 EXTERIOR COMPONENTS ( COMPONENTS AND CLADDING) WILL
 NEED TO BE ADDED TO THE THRESHOLD INSPECTION PLAN ALSO.
  
 2B)THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S
 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS
 REQUIRED BY THIS CODE. CONTACT KEN CONRAD MANAGER OF
 THE SPECIAL INSPECTOR PROGRAM AT (561)805-6666 FOR
 FURTHER INFORMATION BEFORE THE PERMIT MAY BE ISSUED.
 COPIES OF THE SPECIAL INSPECTOR AGREEMENT ARE INCLUDED
 WITHIN THIS REVIEW.
  
  
  
 3) PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE
 PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE
 CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS
 PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT
 BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER.
 THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF
 DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE
 STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION
 ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE
 WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY
 REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY,
 DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ
 FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A
 PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED
 DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A
 CERTIFICATION FROM A LICENSED ENGINEER SHALL BE
 SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL
 OF THE FINAL INSPECTION.
  
 4) PROVISO 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE
 UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED
 MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS.
 AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH
 CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE
 EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN
 SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH
 CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY
 PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE
 CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24
 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE
 SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO
 THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS
 SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO
 SECTION 113 OF THIS CHAPTER.
  
 5) S0.01 DESIGN CRITERIA (D1) PLANS INDICATE DESIGNED
 TO THE 2004 FBC BUT DOES NOT MENTION THE 2007
 SUPPLEMENTS.
  
 6) SHEET S0.02
 6A) NOTE ACP3 PLEASE REVIEW SECTION 1810.3.3
 INSTALATION, AUGERED CAST PILE SHALL NOT BE INSTALLED
 WITHIN SIX PILE DIAMETERS CENTER TO CENTER OF A PILE
 FILLED WITH CONCRETE LESS THAN 12 HOURS OLD.
  
 6B) NOTE ACP5 INDICATES BROKEN OR OTHER NON COMPLIANT
 PILE SECTION 1810.3.3 ALSO PROVIDES INSTALATION
 INSTRUCTIONS WHEN ANY COMPLETED PILE DROPS DURING
 INSTALATION OF ANY ADJACENT PILE, THE PILE SHALL BE
 REPLACED.
  
 7) SHEET S1.01
 7A) THE NORTH PROPERTY LINE IN THE LEFT HAND CORNER
 THERE IS A DETAIL # 1/ S6.01, THERE IS NO SHEET
 S6.01.PLEASE PROVIDE THIS DETAIL AND THE RELATIONSHIP
 TO THE PROPERTY LINE. 3202.2.
  
 7B) PILE CAP SW7 APPEARS TO CROSS THE PROPERTY LINE,
 3202.2.
  
 7C) EAST PROPERTY LINE THERE IS A SECTION/ DETAIL
 MARKER THAT IS NOT FILLED IN, PLEASE UPDATE AND INCLUDE
 THE RELATIONSHIP OF THE GRADE BEAM AND PROPERTY LINE.
 3202.2.
  
 7D) SOUTH PROPERTY LINE DETAIL # 1/ S6.02 ALSO MISSING
 PLEASE PROVIDE DETAIL AND RELATIONSHIP TO PROPERTY
 LINE, 3202.02.
  
 7E) SOUTH PROPERTY LINE DETAIL# 6/ S2.14 PLEASE INCLUDE
 PROPERTY LINE WITHIN THIS DETAIL, 3202.02.
  
 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 9) PLEASE SEE ATTACHMENT OF OUTSTANDING FEES INCLUSIVE
 OF RADON FEES. $10,323.06.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-03-03 Cont ID  
Sent By dpalmer Date 2009-03-03 Time 13:59 Rev Time 0.00
Received By dpalmer Date 2009-03-03 Time 13:59 Sent To  
Notes
2009-03-03 13:59:23 
 *** NOTES REDLINED
  
 FOUNDATION ONLY INCLUDING UNDERGROUND REQUIRED
 GROUNDING ELECTRODE SYSTEM.
 ELECTRICAL RISER NOT REVIEWED.
 A SEPARATE ELECTRICAL PERMIT FOR FOUNDATION WORK OF
 CONDUITS AND GROUNDING ELECTRODE SYSTEM WILL BE NEEDED
 BY A LICENSED ELECTRICAL CONTRACTOR. ONCE THE BASE
 FOUNDATION PERMIT IS ISSUED THE ELECTRICAL CONTRACTOR
 MAY APPLY BY REFERENCING FOUNDATION PERMIT AND WILL BE
 ISSUED A TURN AROUND PERMIT AT THAT TIME. BASE PERMIT
 FEE FOR SUB CONTRACTOR WILL BE DUE. THIS WILL BE $76
 FOR THE SEPARATE ELECTRICAL PERMIT.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2010-09-23 Cont ID  
Sent By mgonzale Date 2010-09-23 Time 07:10 Rev Time 0.50
Received By mgonzale Date 2010-09-23 Time 07:10 Sent To  
Notes
2010-09-23 08:14:36FAIL STATUS:
  
 COMMENT #1
 - NO POLLUTION CONTROL PLAN SUBMITTED OR SUBMITTED WITH
 OUT ENGINEERING SERVICES DEPARTMENT APPROVED STAMP.
 - SILT FENCE NEEDS TO BE INSTALLED AROUND ANY AREAS TO
 BE DISTURBED.
 - FILTER FABRIC IS REQUIRED UNDER THE CATCH BASIN
 GRATES WITH ROCK BAGS AT ANY CURBED INLET ON-SITE TO
 STOP SOLIDS FROM ENTER THE SYSTEM.
 - FILTER FABRIC IS REQUIRED UNDER THE CATCH BASIN
 GRATES WITH ROCK BAGS AT ANY CURBED INLET OFF-SITE TO
 STOP SOLIDS FROM ENTER THE SYSTEM.
 - ADD TURBIDITY BARRIER AT THE OUTFALL TO: (LIST THE
 CANAL OR AREA OF INTRACOASTAL THAT NEEDS PROTECTING.
 -SUPPLY POLLUTION CONTROL PLAN SHOWING:
 A) WHERE SILT SCREENS WILL BE INSTALLED,
 B) SHOW THE PROTECTION OF ALL ON-SITE CATCH BASINS
 C) SHOW PROTECTION OF ALL OFF-SITE CATCH BASINS
 D) INCLUDE DETAILS AS TO THE TYPE OF PROTECTION USED ON
 THE CATCH BASINS
 E) SHOW HOW SITE DIRT WILL NOT BE TRACKED INTO THE
 ROADS
 RUNOFF SHALL BE DISCHARGED FROM IMPERVIOUS SURFACES
 THROUGH RETENTION AREAS, DETENTION DEVICES, FILTERING
 AND CLEANSING DEVICES, OR SUBJECT TO SOME OTHER TYPE OF
 BEST MANAGEMENT PRACTICE (BMP) PRIOR TO DISCHARGE FROM
 THE PROJECT SITE. PROJECTS WHICH INCLUDE SUBSTANTIAL
 PAVED AREAS, SUCH AS, SHOPPING CENTERS, LARGE HIGHWAY
 INTERSECTIONS WITH FREQUENT STOPPED TRAFFIC, AND HIGH
 DENSITY DEVELOPMENTS, PROVISIONS SHALL BE MADE FOR THE
 REMOVAL OF OIL, GREASE, AND SEDIMENT FROM STORM WATER
 DISCHARGES.
  
 CODE OF ORDINANCES, CITY OF WEST PALM BEACH, FLORIDA,
 CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED SEPT. 22,
 2008. (SUPPLEMENT NO. 18), CHAPTER 90 UTILITIES,
 ARTICLE V. STORMWATER POLLUTION PREVENTION
 SEC. 90-203. PROHIBITED DISCHARGES; ILLICIT
 CONNECTIONS.
 (A) GENERAL PROHIBITION. EXCEPT AS PROVIDED IN SECTION
 90-205, AND EXCEPT PURSUANT TO A VALID NPDES
  PERMIT, IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 DIRECTLY OR INDIRECTLY DEPOSIT, DISCHARGE, SPILL, OR
 DUMP INTO
  ANY OF THE PUBLIC WATERS OR MUNICIPAL SEPARATE STORM
 SEWER SYSTEM WITHIN THE CITY, ANY SUBSTANCE OTHER
  THAN THAT COMPOSED ENTIRELY OF STORM WATER.
  
 CODE OF ORDINANCES, CITY OF WEST PALM BEACH, FLORIDA,
 CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED SEPT. 22,
 2008. (SUPPLEMENT NO. 18), CHAPTER 94 ZONING AND LAND
 DEVELOPMENT REGULATIONS
 ARTICLE XIV. LANDSCAPING, LAND CLEARING, AND TREE
 PROTECTION
 SEC. 94-450. VACANT LOT AND CONSTRUCTION SITE
 MAINTENANCE.
 (A) INTENT. THE INTENT OF THIS SECTION IS TO MINIMIZE
 THE DETRIMENTAL HEALTH, SAFETY, GENERAL WELFARE AND
 IMPACTS OF VACANT
  LOTS AND CONSTRUCTION ACTIVITIES ON THE RESIDENTS OF
 THE CITY OF WEST PALM BEACH; TO ENSURE THAT EACH VACANT
 LOT AND
  CONSTRUCTION SITE IS MAINTAINED, AND EACH CONSTRUCTION
 ACTIVITY IS CONDUCTED IN SUCH A MANNER SO AS TO AVOID
  UNNECESSARY INCONVENIENCE AND ANNOYANCE TO THE GENERAL
 PUBLIC AND THE OCCUPANTS OF THE NEIGHBORING PROPERTIES;
  AND TO REQUIRE MAINTENANCE PRACTICES THAT WILL REDUCE
 THE AMOUNT OF SEDIMENT AND OTHER POLLUTANTS LEAVING
  CONSTRUCTION SITES DURING LAND DEVELOPMENT OR LAND
 DISTURBING CONSTRUCTION ACTIVITIES.
  
 COMMENT #2
 FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (FDEP) -
 PROVIDE PROOF OF NOTICE OF INTENT.
 HTTP://EPIC229.DEP.STATE.FL.US/DWRMINOI/
 HTTP://WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/
  
 NPDES STORM WATER NOTICES CENTER, MS# 2510
 FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION
 2600 BLAIR STONE ROAD
 TALLAHASSEE, FLORIDA 32399-2400
 PHONE (850) 245-7522
  
 NOTE: FDEP (PREVIOUSLY FLORIDA DEPARTMENT OF
 ENVIRONMENTAL REGULATION ??? FDER) HISTORICALLY HAS
 REGULATED DREDGE AND FILL OPERATIONS, AND STORM WATER
 DISCHARGE QUALITY UNDER CHAPTERS 62??302 (WATER
 QUALITY), 62-4 (PERMITS), 62-312 (DREDGE AND FILL),
 62-550 (DRINKING WATER), AND 62-25 (REGULATION OF STORM
 WATER DISCHARGE) OF THE FLORIDA ADMINISTRATIVE CODE
 (FAC). FDEP???S REGULATORY RESPONSIBILITIES HAVE GROWN
 SINCE THE ADOPTION OF THE FLORIDA AIR AND WATER
 POLLUTION CONTROL ACT. ADDITIONAL RESPONSIBILITIES
 ASSIGNED THROUGH THE NOVA CANAL SYSTEM WATERSHED STUDY
 AREA INCLUDE DESIGNATING AND ADMINISTERING OUTSTANDING
 FLORIDA WATERS (OFW) AND CLASS III SURFACE WATER
 QUALITY AREAS. FURTHERMORE, LEGISLATION HAS DEFINED
 DEP???S ROLE IN THE STATE NATIONAL POLLUTION DISCHARGE
 ELIMINATION SYSTEM (NPDES) PROGRAM, CREATION OF
 STORMWATER UTILITIES, AND WETLAND PROTECTION. DREDGE
 AND FILL ACTIVITIES WITHIN WETLANDS REQUIRE A PERMIT,
 EXCEPT FOR THOSE WHICH HAVE BEEN DELEGATED TO SFWMD.
  
 COMMENT#3
 PROJECT MUST MEET WATER QUALITY CRITERIA PER SFWMD
 (SOUTH FLORIDA WATER MANAGEMENT DISTRICT CRITERIA)
 RETENTION/DETENTION CALCULATIONS INCLUDING PERVIOUS AND
 IMPERVIOUS AREAS.
 SURFACE WATER CRITERIA:
 SFWMD, APPLICANTS TREAT FIRST INCH OF RUNOFF OR
 2 ?? TIMES THE IMPERVIOUS AREA, WHICH EVER IS GREATER.
 (ADDITIONAL 50% TREATMENT MUST BE PROVIDED FOR
 DISCHARGE INTO CLASS I AND II WATER BODIES.) (LITORAL
 ZONES OR CONSTRUCTED WETLANDS) (INCREASED CONTACT TIME
 WITH ???IN-WATER BAFFLE SYSTEMS OR INCREASED LAKES
 WIDTH AND TRAVEL DISTANCE.
 SUSPENTION OF SOLIDS IS ALSO A QUALITY ISSUE. REDUCE
 THE IMPACT OF NUTRIENT DISCHARGES FROM SURFACE WATER.
 WATER QUALITY.
 PRE ???VS- POST ANALYSIS DEMONSTRATING THAT THE
 PROPOSED POST-DEVELOPMENT DISCHARGE WILL BE NO GREATER
 THAN THE PRE-DEVELOPMENT (CURRENT CONDITION) DISCHARGE
 FOR THE PARAMETER THAT???S IMPAIRED.
  
 COMMENT #4
 ENGINEERING SERVICES EROSION CONTROL & LAND
 STABILIZATION BOND (ORD. 4060-07) *
 HTTP://WWW.CITYOFWPB.COM/ENGINEERING/UPLOADS/2009-06-16
 -14-38-16-PERFORMANCEBOND-IMPROVEMENTS.PDF
  
 COMMENT #5
 - NO SIDEWALK OR DRIVEWAY APPROACH PLAN SUBMITTED -
 ENGINEERING SERVICES DEPARTMENT APPROVAL.
 DRIVEWAY APPROACH CONFIGURATION, SITE CONSTRUCTION
 ACCESSIBILITY AND LOGISTICS PLAN SHOULD BE DISCUSSED
 WITH THE RIGHT-OF-WAY DIVISION PRIOR TO BEING SUBMITTED
 TO CONSTRUCTION SERVICES.
 MAINTENANCE OF TRAFFIC PLAN (M.O.T. PLAN) ??? IS
 REQUIRED TO ADDRESS SPECIFIC PLANS FOR LANE CLOSURES,
 DETOURS, OR OTHER IMPACTS ON OR AFFECTING STREETS AND
 ROADS UNDER THE JURISDICTION OF THE CITY.
 THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE
 CONSTRUCTION PERMITS ADDRESS, RESERVATION OF CAPACITY
 BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS,
 BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION.
 CONTACT THE RIGHT-OF-WAY REVIEWER, WINDEL PALMER,
 PROJECT COORDINATOR, THE TRAFFIC ENGINEERS OFFICE AT:
 LOCATION ADDRESS:
 CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 401 - CLEMATIS, FOURTH FLOOR,
 WEST PALM BEACH FL 33401
 MAILING ADDRESS:
 CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 P.O. BOX 3366
 WEST PALM BEACH FL 33402
 TELEPHONES:
 MAIN OFFICE: 561-494-1040
 FAX: 561-494-1116
  
 COMMENT #6
 CITY OF WEST PALM BEACH HAS A NUMBER OF REGULATIONS AND
 PERMIT REQUIREMENTS WHICH DIRECTLY AFFECT THE
 DEVELOPMENT AND INSTALLATION OF WATER AND WASTEWATER
 UTILITIES WITHIN THE CITY OF WEST PALM BEACH.
 PLEASE SEE: DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS
 AT THE LINK BELOW:
 HTTP://WWW.CITYOFWPB.COM/ENGINEERING/UPLOADS/2010-08-24
 -14-41-27-DEVELOPMENTPERMITPACKAGE2010.PDF
  
 COMMENT #7
 PROVIDE ELEVATIONS AS IT RELATES TO NEW AND EXISTING
 BUILDINGS WHICH HAVE PLUMBING DRAIN OUTLETS AT AN
 ELEVATION 12??? OR LESS ABOVE THE GROUND SURFACE OF THE
 NEXT UPSTREAM
 MANHOLE, WHERE THE ELEVATION OF ANY FLOOR IS AT OR
 BELOW THE INVERT OF THE ADJACENT CITY SANITARY SEWER
 MAIN OR IS LESS THAN 12???ABOVE THE GROUND SURFACE OF
 THE NEXT UPSTREAM
 MANHOLE, OR WHERE A CONDITION EXISTS WHERE A PLUG IN
 THE CITY SANITARY SEWER MAIN WILL CAUSE THE HYDRAULIC
 GRADIENT TO RISE ABOVE THE LOWEST FLOOR LEVEL.
  
 COMMENT #8
 SUBMIT 3 COPIES OF APPROVED SITE PLAN.
  
 *******************************************************
 *************************
 CITY OF WPB ENGINEERING FORMS AND DESIGN REQUIREMENT
 INFORMATION
 CAN BE FOUND AT THE INTERNET LINK BELOW
 HTTP://WWW.CITYOFWPB.COM/ENGINEERING/ENG_FORMS.PHP
 *******************************************************
 *************************
  
 FEEL FREE TO CONTACT ME IF ANY QUESTIONS OR CONCERNS,
 THANKS!
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2009-03-02 Cont ID  
Sent By mgonzale Date 2009-03-02 Time   Rev Time 1.00
Received By mgonzale Date 2009-03-02 Time 16:04 Sent To ENG
Notes
2009-03-02 16:04:53*** PASSED PER ENG EMERY FABIAN 561 494-1040 ***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-03-04 Cont ID  
Sent By mwennerg Date 2009-03-04 Time 11:23 Rev Time 0.00
Received By mwennerg Date 2009-03-04 Time 11:23 Sent To  
Notes
2009-03-04 11:25:25***FOUNDATION ONLY***
  
  
 FIRE PROTECTION LINES AND ASSOCIATED EQUIPMENT IS
 PROHIBITED AT ANY POINT BENEATH THE FOUNDATION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-06-03 Cont ID  
Sent By jgomez Date 2009-06-03 Time 10:56 Rev Time 0.00
Received By jgomez Date 2009-06-03 Time 10:56 Sent To  
Notes
2009-06-03 11:06:43SENT TO BOX C4.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-03-09 Cont ID  
Sent By jwitmer Date 2009-03-09 Time 11:44 Rev Time 0.00
Received By jwitmer Date 2009-02-25 Time 09:16 Sent To  
Notes
2009-02-25 09:16:35TO "COMM" BD#56---EXPEDITED---

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2010-06-15 Time   Rev Time 0.00
Received By amckenzi Date 2010-06-15 Time 12:24 Sent To  
Notes
***NONE***

Review Stop X PERMIT EXTENSION
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2010-06-15 Time   Rev Time 0.00
Received By amckenzi Date 2010-06-15 Time 12:29 Sent To  
Notes
2010-06-15 12:26:10EXTEND PERMIT APPLICATION 8/14/10/AMM

Review Stop X PERMIT EXTENSION
Rev No 2 Status N Date 2010-04-05 Cont ID  
Sent By amckenzi Date 2010-04-05 Time 14:36 Rev Time 0.00
Received By amckenzi Date 2010-04-05 Time 14:35 Sent To  
Notes
2010-04-05 14:37:05EXTEND PERMIT APPLICATION TO 6/16/10 PER DBW/AMM

Review Stop X PERMIT EXTENSION
Rev No 1 Status N Date 2009-12-21 Cont ID  
Sent By rbrown Date 2009-12-21 Time 18:41 Rev Time 0.00
Received By rbrown Date 2009-12-21 Time 16:09 Sent To  
Notes
2009-12-21 18:41:27PERMIT APPLICATION EXTENDED TO 3/18/2010 (NOT
 6/18/2010).
  
2009-12-21 16:14:23PERMIT APPLICATION EXTENDED TO 6/18/2010 PER RAB

Review Stop Z ZONING
Rev No 3 Status P Date 2009-06-18 Cont ID  
Sent By aaponte Date 2009-06-18 Time 10:47 Rev Time 0.00
Received By aaponte Date 2009-06-18 Time 10:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2009-06-10 Cont ID  
Sent By mflis Date 2009-06-10 Time 13:55 Rev Time 0.00
Received By mflis Date 2009-06-10 Time 13:55 Sent To  
Notes
2009-06-10 13:58:04ZONING REVIEW: FAILED
  
 FOUNDATION PERMIT ONLY
  
 OLD COMMENTS:
  
 1) APPROVED TREE ALTERATION PERMIT WITH MITIGATION
 MEASURES REQUIRED PRIOR TO FOUNDATION APPROVAL. PLEASE
 COORDINATE WITH LANDSCAPE PLANNER ROBERT KUSSNER AT
 822-1435. ALTERATION MITIGATION MEASURES ARE UNDER
 REVIEW, AND NO FINAL DETERMINATION HAS BEEN RESOLVED
 WITH OWNER YET.
 2) OK
 3) OK
 4) OK
 5) OK
 6) OK
 7) ON SL-1, PLANS INDICATE PARTIAL CLOSURE OF ALLEY.
 PLEASE COORDINATE WITH ENGINEERING SERVICES AS A
 REVOCABLE PERMIT OR OTHER TEMPORARY PERMIT MAY BE
 NECESSARY TO CLOSE THE ALLEY DURING CONSTRUCTION. (FOR
 REFERENCE)
  
 NEW COMMENTS:
  
 1) ARCHITECTURAL DRAWINGS ARE NOT SEALED. IF INCLUDED
 WITH DRAWING SET, ARCH DRAWINGS SHOULD HAVE RAISED ARCH
 SEAL.
  
 MATT FLIS - 822-1445

Review Stop Z ZONING
Rev No 1 Status F Date 2009-03-03 Cont ID  
Sent By mflis Date 2009-03-03 Time 08:51 Rev Time 0.00
Received By mflis Date 2009-03-03 Time 08:51 Sent To  
Notes
2009-03-03 09:08:19ZONING REVIEW: FAILED
  
 FOUNDATION PERMIT ONLY
  
 1) APPROVED TREE ALTERATION PERMIT WITH MITIGATION
 MEASURES REQUIRED PRIOR TO FOUNDATION APPROVAL. PLEASE
 COORDINATE WITH LANDSCAPE PLANNER ROBERT KUSSNER AT
 822-1435.
 2) ON C-6, PORTION OF SIDEWALK INDICATES 2% SLOPE
 TRANSITIONING TO 7.5% SLOPE. A SECTION MUST BE PROVIDED
 THROUGH THIS AREA AND/OR ALL SIMILAR CONDITIONS FOR
 REVIEW. PUBLIC SIDEWALKS SHALL BE CONSISTENT IN SLOPE
 AND POSE NO HAZARD TO PEDESTRIANS OR THOSE WITH
 DISABILITIES. SIGNIFICANT SLOPES CAN BE PROBLEMATIC FOR
 THOSE IN WHEELCHAIRS.
 3) ON C-9, ALL UTILITY METERS SHALL BE LOCATED OUT OF
 SIDEWALK AREA, INCLUDING IRRIGATION AND SPRINKLER
 CONNECTIONS. THE SIDEWALK SHALL BE FREE AND CLEAR FOR
 ITS FULL WIDTH (SEE EAST END OF BUILDING).
 4) ON C-9, WEST END OF BUILDING: CAN WALL-MOUNTED FDC
 BE RELOCATED TO BUILDING INSET AREA SO THAT IT DOES
 STICK OUT DIRECTLY INTO SIDEWALK PATH OF TRAVEL? (WOULD
 BE SHIFTED SLIGHTLY TO EAST).
 5) ON S1.01 - CONFIRM THAT ALL FOOTINGS AND SLABS ARE
 LOCATED WITHIN THE PROPERTY LIMITS. ANY STRUCTURAL
 ELEMENTS WHICH EXTEND INTO RIGHT-OF-WAY (STREET OR
 ALLEY) WILL REQUIRE EASEMENTS.
 6) ON SL-1, CONSTRUCTION FENCE PERMIT WILL BE REQUIRED
 FOR SITE.
 7) ON SL-1, PLANS INDICATE PARTIAL CLOSURE OF ALLEY.
 PLEASE COORDINATE WITH ENGINEERING SERVICES AS A
 REVOCABLE PERMIT OR OTHER TEMPORARY PERMIT MAY BE
 NECESSARY TO CLOSE THE ALLEY DURING CONSTRUCTION.
  
 MATT FLIS - 822-1445