Plan Review Stops For Permit 09020471 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-05-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-05-19 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-05-19 |
Time |
15:09 |
Sent To |
|
|
Notes |
2009-05-19 15:10:12 | PLANS REDLINED | | TAMKO 07-0111.03 REVIEWED BY DOR |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-04-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-04-30 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-04-30 |
Time |
08:09 |
Sent To |
|
|
Notes |
2009-04-30 09:42:52 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STA | | | | 1-4. ADDRESSED. | | | | 4. SHOW COMPLIANCE WITH FBC R704, INSPECTION FOR | | TERMITES. | | | | 2ND REVIEW, DETAILS SHOW STUCCO EXTENDING TO GRADE. | | PLEASE SEE FBC R704 AND REVISE DETAIL ACCORDINGLY. | | | | 5-6. ADDRESSED. | | | | 7. ROOF PERMIT HAS BEEN APPLIED FOR. THEREFORE, ALL | | ROOF PERMIT INFORMATION REQUIRED AT THIS TIME: | | | | A. ADDRESSED. | | | | B. PROVIDE ENHANCED FASTENING PATTERN FOR PERIMETER AND | | CORNER ZONES | | | | 2ND REVIEW, PLAN WAS REVISED TO STATE "FASTEN TO ALL | | SUPPORTS W/8D NAILS @ 6"EDGES, 6" FIELD." IT APPEARS | | THAT THIS IS INTENDED TO BE PLYWOOD SHEATHING | | FASTENING, BUT THIS DOES NOT COMPLY WITH FBC R | | 803.2.3.1 ZONE 3. ADDITIONALLY, THIS DOES NOT ADDRESS | | THE COMMENT FOR THE ROOF. PLEASE SEE NOA, GENERAL | | LIMITATION #7 ON PAGE 19, ENHANCED FASTENING TO BE IN | | ACCORDANCE WITH RAS117 (ALSO NOTE THAT THERE ARE TWO | | DIFFERENT FASTENING OPTIONS; ENHANCED FASTENING SHOULD | | REFER TO WHICH OPTION IS PROPOSED IN ORDER TO DETERMINE | | CODE COMPLIANCE UNLESS THE PATTERN PROPOSED COMPLIES | | WITH BOTH). PLEASE NOTE THAT IF ALL REQUIRED | | INFORMATION IS NOT PROVIDED PRIOR TO ISSUANCE OF THE | | MASTER PERMIT, THE ROOF PERMIT WILL BE VOIDED AND A | | SEPARATE PERMIT WILL BE REQUIRED IN ORDER TO AVOID | | DELAYS ON THE MASTER PERMIT. | | | | 8. ADDRESSED. | | | | 9. FBC R403.1.4, SHOW DISTANCE OF BOTTOM OF FOOTING TO | | GRADE. | | | | 2ND REVIEW, THIS IS SHOWN AS 10IN. SEE FBC R403.1.4, | | MINIMUM DEPTH REQUIRED IS 12IN. | | | | 10-11. ADDRESSED. | | | | 12. ROOF SHEATHING NAILING NOT COMPLIANT WITH FBC R | | 803.2.3.1. SEE DETAILS 1 A3, 2 A3, CHECK ALL. | | | | 2ND REVIEW, 4IN REQUIRED AT ZONE 3, SEE FBC R803.2.3.1. | | | | 13-14. ADDRESSED. | | | | 15. IMPACT FEES MAY BE DUE. PLEASE CONTACT PALM BEACH | | COUNTY, 233-5025. | | | | 2ND REVIEW, THE PLANS MUST BE STAMPED AND THE RECEIPT | | (IF FEES ARE DUE) ATTACHED TO THE APPLICATION. THIS MAY | | BE DONE AFTER ALL PLAN REVIEWS ARE COMPLETED BUT MUST | | BE DONE PRIOR TO PERMIT ISSUANCE. | | | | 16-17. ADDRESSED. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-03-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-30 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-03-30 |
Time |
13:50 |
Sent To |
|
|
Notes |
2009-03-30 14:33:59 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STA | | | | 1. TYPE IV CONSTRUCTION DECLARED; NOT CONSISTENT WITH | | DETAILS. TYPE IV IS HEAVY TIMBER; PLEASE CLARIFY. | | | | 2. PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF | | RECORD FBC*106. | | | | 3. PROVIDE ROOM DESIGNATIONS ON THE PLAN, FBC*106. | | | | 4. SHOW COMPLIANCE WITH FBC R704, INSPECTION FOR | | TERMITES. | | | | 5. FBC R703.6.3, BOND BREAK REQUIRED, REVISE ALL | | AFFECTED DETAILS. | | | | 6. ENERGY CALCS REQUIRED FBC 13-103. | | | | 7. ROOF PERMIT HAS BEEN APPLIED FOR. THEREFORE, ALL | | ROOF PERMIT INFORMATION REQUIRED AT THIS TIME: | | | | A. INDICATE WHICH APPROVED ASSEMBLY IS TO BE INSTALLED | | | | B. PROVIDE ENHANCED FASTENING PATTERN FOR PERIMETER AND | | CORNER ZONES | | | | 8. SHOW COMPLIANCE WITH FBC R401.3, DRAINAGE. | | | | 9. FBC R403.1.4, SHOW DISTANCE OF BOTTOM OF FOOTING TO | | GRADE. | | | | 10. SHOW FINISHED FLOOR ELEVATION IN RELATION TO GRADE, | | FBC*106. | | | | 11. SMOKE ALARMS REQUIRED, FBC R313.1. | | | | 12. ROOF SHEATHING NAILING NOT COMPLIANT WITH FBC R | | 803.2.3.1. SEE DETAILS 1 A3, 2 A3, CHECK ALL. | | | | 13. DETAIL 4 A3 SPECIFIES 2X WALL STUDS, IN CONFLICT | | WITH OTHER DETAILS, PLEASE CLARIFY DESIGN INTENT. | | CALCULATIONS MAY BE REQUIRED. | | | | 14. DETAIL 4 A3 SPECIFIES "APPROVED HURRICANE STRAP," | | PLEASE SPECIFY (BRAND, MODEL #). CHECK ALL DETAILS. | | | | 15. IMPACT FEES MAY BE DUE. PLEASE CONTACT PALM BEACH | | COUNTY, 233-5025. | | | | 16. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | FOR THE WINDOW, FAC9B72. | | | | 17. IMPACT PROTECTION REQUIRED FOR THE NEW WINDOW, FBC | | R301. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-04-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-04-16 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-04-16 |
Time |
13:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-03-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-03-09 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-03-09 |
Time |
09:44 |
Sent To |
M |
|
Notes |
2009-03-09 10:04:48 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND | | 210.52(A)(2). 2005 NEC. SEE REVIEWED PLAN FOR | | DEFICIENCIES | | | | 2} 210.70(B)(B) FOR DWELLING UNITS, ATTACHED GARAGES, | | AND DETACHED GARAGES WITH ELECTRIC POWER, AT LEAST ONE | | WALL SWITCH???CONTROLLED LIGHTING OUTLET SHALL BE | | INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR SIDE | | OF OUTDOOR ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS. | | A VEHICLE DOOR IN A GARAGE SHALL NOT BE CONSIDERED AS | | AN OUTDOOR ENTRANCE OR EXIT. | | | | 2} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE | | ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE | | INTERCONNECTION AND LOCATE THE ALARMS ON THE PLAN. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2009-04-13 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2009-04-13 |
Time |
12:30 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2009-04-13 |
Time |
12:29 |
Sent To |
|
|
Notes |
2009-04-13 12:30:36 | HISTORIC APPROVED BY JPAPA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-05-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-05-19 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-05-19 |
Time |
11:29 |
Sent To |
|
|
Notes |
2009-05-19 11:29:48 | TO SAMANTA'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-04-13 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2009-04-13 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2009-04-13 |
Time |
15:48 |
Sent To |
|
|
Notes |
2009-04-13 15:50:19 | TO 'SFR' #1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-03-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-30 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-02-26 |
Time |
08:38 |
Sent To |
|
|
Notes |
2009-02-26 08:41:06 | TO "SFR" "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2009-04-17 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2009-04-17 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2009-04-17 |
Time |
13:15 |
Sent To |
|
|
Notes |
2009-04-17 13:18:47 | MECHANICAL PERMIT IS NOT REQUIRED .( WALL UNITS) |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2009-03-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2009-03-25 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2009-03-25 |
Time |
15:03 |
Sent To |
P |
|
Notes |
2009-03-25 15:04:13 | NO MECHANICAL PLANS . |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2009-03-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-03-27 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-03-27 |
Time |
15:35 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-04-29 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-04-29 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-04-29 |
Time |
12:54 |
Sent To |
P |
|
Notes |
2009-04-29 12:59:35 | ROUTED TO SH |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-03-05 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-03-05 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-03-05 |
Time |
11:47 |
Sent To |
E |
|
Notes |
2009-03-05 11:55:10 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | 2. INDICATE THE SETBACK DIMENSIONS FROM ANY EXTERIOR | | IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. PURSUANT | | TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-72(A)(2): | | SINGLE-FAMILY LOW DENSITY (SF7) RESIDENTIAL DISTRICT - | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | A. FRONT: 25 FEET; | | | | B. CORNER: 12.5 FEET; | | | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER | | IS LESS; | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | 3. INDICATE OVERHANG DIMENSIONS OF THE PROPOSED | | ADDITION. PURSUANT TO THE ZLDR, SECTION 94-305(B): | | OVERHANGS SHALL NOT PROJECT MORE THAN THREE (3) FEET | | INTO A REQUIRED SETBACK. | | | | 4. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED ADDITION ON | | THE ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION | | 94-611, THE HEIGHT SHALL BE MEASURED AS THE VERTICAL | | DISTANCE FROM THE AVERAGE ELEVATION OF THE FINISHED | | GRADE OF THE BUILDING TO THE MEAN HEIGHT LEVEL BETWEEN | | EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. | | | | 5. INDICATE IF ANY TREES WILL BE REMOVED AS A RESULT OF | | THE PROPOSED PROJECT. IF YES, A TREE ALTERATION/REMOVAL | | PERMIT WILL BE REQUIRED. CONTACT ROBERT KUSSNER, CITY | | LANDSCAPE PLANNER, AT (561) 822-1462 FOR THE | | APPLICATION. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | GENERATE ADDITIONAL COMMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1444 OR (561) 805-6720 | | E-MAIL: [email protected] | | |
|
|