Plan Review Details - Permit 09020334
Plan Review Stops For Permit 09020334
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-03-10 Cont ID  
Sent By mjacobs Date 2009-03-10 Time 16:20 Rev Time 0.00
Received By mjacobs Date 2009-03-10 Time 16:10 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-03-04 Cont ID  
Sent By btrobaug Date 2009-03-04 Time 14:36 Rev Time 0.00
Received By btrobaug Date 2009-03-04 Time 14:30 Sent To B
Notes
2009-03-04 14:36:27 
  
 PROVISO
  
 680.26(B) BONDED PARTS THE PARTS SPECIFIED IN
 680.26(B)(1) THROUGH (B)(5) SHALL BE BONDED
 TOGETHER.THE METAL PARTS REQUIRED TO BE BONDED PER
 680.26(B) INCLUDE ALL METAL PARTS OF ELECTRICAL
 EQUIPMENT ASSOCIATED WITH THE WATER-CIRCULATING SYSTEM
 OF THE POOL, ALL METAL PARTS OF THE POOL STRUCTURE, AND
 ALL FIXED METAL PARTS, WHICH INCLUDE CONDUIT AND
 PIPING, METAL DOOR FRAMES, AND METAL WINDOW FRAMES,
 WITHIN 5 FT OF THE INSIDE WALLS OF THE POOL AND NOT
 SEPARATED BY A PERMANENT BARRIER. THE BONDING OF THESE
 PARTS DOES NOT MEAN THEY ARE REQUIRED TO BE CONNECTED
 TO EACH OTHER; RATHER, IT MEANS THEY ARE REQUIRED TO BE
 CONNECTED TO A COMMON BONDING GRID BY USING AN
 INSULATED, COVERED, OR BARE SOLID COPPER CONDUCTOR NOT
 SMALLER THAN 8 AWG OR BY USING BRASS OR OTHER
 CORROSION-RESISTANT METAL CONDUIT. SEE EXHIBIT 680.11.
 CONNECTIONS ARE REQUIRED TO BE MADE BY EXOTHERMIC WELDS
 OR BY LISTED PRESSURE CONNECTORS, CLAMPS, OR OTHER
 LISTED MEANS, IN ACCORDANCE WITH 250.8.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-02-26 Cont ID  
Sent By adarroug Date 2009-02-26 Time 11:09 Rev Time 0.00
Received By adarroug Date 2009-02-26 Time 11:09 Sent To B
Notes
2009-02-26 11:10:13TO "E" BOX--ALUMINUM FENCE SURROUNDING POOL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-02-25 Cont ID  
Sent By mcruz Date 2009-02-25 Time 10:04 Rev Time 0.00
Received By mcruz Date 2009-02-18 Time 08:38 Sent To  
Notes
2009-02-18 08:38:44TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2009-02-25 Cont ID  
Sent By mcruz Date 2009-02-25 Time 10:03 Rev Time 0.00
Received By mcruz Date 2009-02-25 Time 09:58 Sent To  
Notes
***NONE***