Plan Review Stops For Permit 09020221 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2009-02-25 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2009-02-25 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2009-02-24 |
Time |
17:00 |
Sent To |
|
|
Notes |
2009-02-24 18:25:13 | NOTE: | | 105.13. SPECIAL FOUNDATION PERMIT | | WHEN APPLICATION FOR A PERMIT TO ERECT OR ENLARGE A | | BUILDING HAS BEEN FILED, & PENDING ISSUANCE OF SUCH | | PERMIT, THE BUILDING OFFICIAL MAY, AT HIS/ HER | | DISCRETION, ISSUE A SPECIAL PERMIT FOR THE FOUNDATION | | ONLY, UPON WRITTEN REQUEST OF THE OWNER AND CONTRACTOR. | | THE HOLDER OF SUCH A SPECIAL PERMIT IS PROCEEDING AT | | HIS OR HER OWN RISK AND WITHOUT ASSURANCE THAT A PERMIT | | FOR THE REMAINDER OF THE WORK WILL BE GRANTED AND THAT | | CORRECTIONS WILL NOT BE REQUIRED IN ORDER TO MEET THE | | PROVISIONS OF THE TECHNICAL CODE. | | | | PROVISOR: PROVIDE INFORMATION PERTAINING TO TERMITE | | PROTECTION TO THE INSPECTOR PRIOR TO ANY CONCRETE POUR. | | SEE FBC 106.3.5.1.1(8) AND FBC SECTION 1816. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-04-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-02 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-02 |
Time |
17:41 |
Sent To |
|
|
Notes |
2009-04-02 17:43:00 | VERIFIED IMPACT FEES PAID UNDER MAIN BUILDING. | | PLANS TO BE PROCESSED FOR ISSUANCE BY LUIS MARTINEZ |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-03-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-03-03 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-03-03 |
Time |
17:50 |
Sent To |
|
|
Notes |
2009-03-03 17:50:49 | *** NOTE*** | | | | 1) NOTE: PLAN REVIEW TO REMAIN IN FAILED STATUS UNTIL | | PLANS HAVE HAD REQUIRED STAMPS AND ATTACHED RECEIPT | | FROM PALM BEACH COUNTY IMPACT FEE DEPARTMENT. AS THE | | LAST BUILDING PLANS EXAMINER VERIFICATION OF THE ABOVE | | MUST BE DONE BEFORE REVIEW CAN BE PLACED INTO A PASSED | | STATUS FOR ISSUANCE. | | THIS IS NOT DONE BY THE ENGINEERING OR ZONING | | DEPARTMENTS | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-02-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-02-23 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-02-23 |
Time |
17:36 |
Sent To |
|
|
Notes |
2009-02-23 17:37:02 | ** DENIED ** | | | | | | | | 1) NOTE: PLEASE SUBMIT PLANS SHOWING COMPLETE GROUNDING | | ELECTRODE SYSTEM. MUST INCLUDE ALL MINIMUMS PER | | 250.50,250.104, 250.53 ETC | | FOUNDATION/ FOOTER STEEL, METALLIC COLD WATER SYSTEMS, | | BUILDING STEEL ETC | | | | 2) NOTE: THE ELECTRICAL SITE PLAN DOES NOT INCLUDE ANY | | REVISED LOCATIONS FOR SERVICE ENTRANCE CONDUITS. THERE | | WERE COMMENTS ON THE BASE BUILDING WHICH WOULD REVISE | | POSSIBLE LOCATIONS AND CONDUITS TO BE INSTALLED IN | | FOUNDATION AND SLAB. | | PLEASE SEE COMMENTS ON BASE BUILDING WITH RESPECT TO | | 230.70 FOR DISCONNECTING MEANS LOCATION. | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2009-03-11 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2009-03-11 |
Time |
08:29 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2009-03-11 |
Time |
08:29 |
Sent To |
|
|
Notes |
2009-03-11 08:31:16 | ***** APPROVED AS-NOTED **** | | | | PLANS PRESENTED SHOWED SITE ELECTRICAL ONLY. | | CALL 811 BEFORE YOU DIG. | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2009-03-02 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2009-03-02 |
Time |
11:27 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2009-03-02 |
Time |
11:26 |
Sent To |
ENG |
|
Notes |
2009-03-02 11:29:58 | **** NOT APPROVED ***** | | | | F.F.E. MAY NEED TO BE LOOKED AT DUE TO PALM BEACH LAKES | | ROAD ELEVATION AND STORMWATER MANAGEMENT. | | THE STORMWATER CONTROL ELEVATION MANHOLE SEEMS TO HAVE | | CONFLICTING INFORMATION THAT WILL NEED EXPLANATION OR | | ENGINEERING REVIEW. | | PLEASE CONTACT ENGINEERING FOR FURTHER DETAIL. (561) | | 494-1085 MANNY GONZALEZ - PROJECT COORDINATOR. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2009-02-24 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2009-02-24 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2009-02-24 |
Time |
13:58 |
Sent To |
|
|
Notes |
2009-02-24 13:59:15 | FOUNDATION ONLY-OK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-03-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-03-03 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-03-03 |
Time |
15:33 |
Sent To |
|
|
Notes |
2009-03-03 15:33:53 | TO "COMM" BD#17 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-03-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-03-02 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-23 |
Time |
09:51 |
Sent To |
|
|
Notes |
2009-02-23 09:52:13 | TO COMM BOARD #45 | | PAID EXPEDITED REVIEW |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-02-23 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-02-23 |
Time |
17:22 |
Sent To |
|
|
Notes |
2009-02-23 17:28:40 | FOUNDATION ONLY OK THIS PERMIT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-03-12 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-03-12 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-03-12 |
Time |
16:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-02-26 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-02-26 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-02-26 |
Time |
09:39 |
Sent To |
|
|
Notes |
2009-02-26 09:39:57 | ZONING PLAN REVIEW | | | | PERMIT NO.: 09020221 | | ADDRESS: 1615 PALM BEACH LAKES BOULEVARD | | CONTRACTOR/CONTACT: RICHARD RHODES | | TELEPHONE NO.: (954) 429.3700 | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) INFORMAL SITE PLAN REVIEW APPLICATION MUST BE | | APPROVED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. AS | | PER DISCUSSIONS WITH WACHOVIA, THERE ARE FEW | | OUTSTANDING ISSUES THAT ARE BEING RESOLVED WITH THE | | CITY'S ENGINEERING SERVICES DEPARTMENT. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. | | |
|
|