Plan Review Details - Permit 09020142
Plan Review Stops For Permit 09020142 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-04-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-04-01 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-04-01 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-02-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-02-17 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-02-17 |
Time |
08:56 |
Sent To |
|
|
Notes |
2009-02-17 09:24:21 | 2004 FBC W/2007 REVISIONS | | INSTALL FABRIC AWNING | | | | DENIED BY BUILDING | | | | 1) ADDRESS ZONING COMMENTS. | | | | 2) SHOW COMPLIANCE WITH FBC 3105.1.1.1 FABRIC AWNINGS | | AND FABRIC-COVERED FRAMES LOCATED OVER PUBLIC PROPERTY | | OR IN AREAS ACCESSIBLE TO THE GENERAL PUBLIC SHALL BE | | CONSTRUCTED SO THAT NO RIGID PART OF SUCH FABRIC | | AWNINGS OR FABRIC-COVERED FRAMES SHALL BE LESS THAN 7 | | FEET, 6 INCHES (2286 MM) FROM THE GRADE DIRECTLY BELOW, | | AND NO PART OF THE CLOTH DROP SHALL BE LESS THAN 7 FEET | | (2134 MM). | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-03-27 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-03-27 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-03-25 |
Time |
10:18 |
Sent To |
Z |
|
Notes |
2009-03-27 10:19:14 | DELIVERED TO ES IN ZONING. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-02-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-13 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-13 |
Time |
14:58 |
Sent To |
|
|
Notes |
2009-02-13 14:59:33 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-02-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-02-17 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-02-06 |
Time |
10:12 |
Sent To |
|
|
Notes |
2009-02-06 10:12:31 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-03-31 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-03-31 |
Time |
10:23 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2009-03-31 |
Time |
10:23 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2009-02-12 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-02-12 |
Time |
16:29 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2009-02-12 |
Time |
16:29 |
Sent To |
I |
|
Notes |
2009-02-12 16:30:05 | FAILED | | | | 1) THE CITYPLACE "APPROVED" STAMP IS REQUIRED ON THE | | AWNING COLOR SHEET. | | | | 2) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS | | MUST PROVIDE A MINIMUM OF EIGHT (8) FEET OF CLEARANCE | | BETWEEN THE FLOOR AND THE LOWEST POINT OF THE AWNING. | | PLEASE PROVIDE THE HEIGHT INFORMATION. | | | | 3) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS | | ON THE SECOND FLOOR SHALL PROJECT THREE (3) FEET FROM | | THE BUILDING FACADE. THE AWNING IS SHOWN PROJECTING 7' | | 3-1/2" FROM THE BUILDING FACADE. | | | | 4) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT BOTH | | SIDES OF A SHED AWNING MUST BE OPEN. UNABLE TO TELL | | FROM DRAWINGS IF THE END OF THE AWNING NOT AFFIXED TO | | THE WALL IS OPEN. PLEASE PROVIDE INFORMATION. | | | | 5) THE CITYPLACE MASTER SIGN PLAN DOES NOT ALLOW | | VALANCES ON SECOND STORY AWNINGS. UNABLE TO TELL FROM | | THE DRAWINGS IF AWNING HAS VALANCES. PLEASE PROVIDE | | INFORMATION. | | | | 6) THE CITYPLACE MASTER SIGN PLAN ALLOWS VARIANCES FROM | | THE PROVISIONS OF 2, 3, 4 & 5 ABOVE. PROVIDE A | | NOTARIZED LETTER FROM CITYPLACE THAT THEY HAVE GRANTED | | THE SPECIFIC VARIANCES NEEDED TO CONSTRUCT THE PROPOSED | | AWNINGS OR REVISE AWNINGS TO ADHERE TO THE CITYPLACE | | MASTER SIGN PLAN REQUIREMENTS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. | | |
|
|
|