Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-05-15 Cont ID  
Sent By rmcdouga Date 2009-05-15 Time 10:13 Rev Time 0.00
Received By rmcdouga Date 2009-05-15 Time 10:13 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-03-24 Cont ID  
Sent By rmcdouga Date 2009-03-24 Time 10:35 Rev Time 0.00
Received By rmcdouga Date 2009-03-24 Time 10:35 Sent To Z
Notes
2009-03-24 11:05:282004 FBC W/2007 REVISIONS
 CONCRETE BLOCK FENCE
  
 DENIED BY BUILDING
  
 1) THE PLANS HAVE AN ENGINEER LISTED IN THE TITLE BLOCK
 AND ARE THEREFORE REQUIRED TO HAVE THE EMBOSSED SEAL
 AND ORIGINAL SIGNATURE OF THE ENGINEER. FS 471
  
 2) THE PERMIT APPLICATION DATE WAS PRIOR TO THE
 IMPLEMENTATION DATE OF THE 2007 FBC. THEREFORE, THE
 2004 FBC IS THE CODE THAT APPLIES. PLEASE REVISE PLANS
 TO SPECIFY THE 2004 FBC. FS 553
  
 3) THE EDITION OF ASCE 7 REFERENCED BY THE 2004 FBC IS
 ASCE 7-02. PLEASE CORRECT PLANS. 2004 FBC CHAPTER 35
  
 4) THE PLANS SHOW A FOOTING FOR THE WALL THAT EXTENDS
 14" ON EACH SIDE OF THE WALL. PLEASE NOTE THAT THE
 FOOTING CAN NOT EXTEND BEYOND THE PROPERTY LINES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-03-02 Cont ID  
Sent By rmcdouga Date 2009-03-02 Time 07:38 Rev Time 0.00
Received By rmcdouga Date 2009-03-02 Time 07:38 Sent To  
Notes
2009-03-02 07:41:052004 FBC W/2007 REVISIONS
 CONCRETE FENCE
  
 DENIED BY BUILDING
  
 1) COMMENTS FROM FIRST REVIEW WERE NOT ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-02-18 Cont ID  
Sent By rmcdouga Date 2009-02-18 Time 06:54 Rev Time 0.00
Received By rmcdouga Date 2009-02-18 Time 06:53 Sent To  
Notes
2009-02-18 07:40:372004 FBC W/2007 REVISIONS
 CONCRETE FENCE
  
 DENIED BY BUILDING
  
 1) PLEASE CLARIFY IF THE WALL IS POURED REINFORCED
 CONCRETE OR REINFORCED CONCRETE BLOCK. FBC 106.1.1*
 CITY AMENDMENTS
  
 2) SPECIFY DESIGN DATA ON THE PLAN. WINDSPEED, EXPOSURE
 CATEGORY, ETC. R301.1
  
 3) SUBMIT 2 COPIES OF STRUCTURAL DETAILS. PROVIDE ALL
 DIMENSIONS. SPECIFY THE FOUNDATION SIZE AND
 REINFORCEMENT. SPECIFY WALL REINFORCEMENT SIZE AND
 SPACING. IF IT IS A CONCRETE BLOCK FENCE SPECIFY THE
 TIE BEAM SIZE AND REINFORCING. PROVIDE ALL APPLICABLE
 STRUCTURAL INFORMATION. R301.1
  
 4) INDICATE THE NAME AND CONTACT INFORMATION OF THE
 PERSON RESPONSIBLE FOR THE DESIGN ON THE PLANS. FBC
 106.1.2* CITY AMENDMENTS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-05-14 Cont ID  
Sent By shill Date 2009-05-14 Time 10:49 Rev Time 0.00
Received By shill Date 2009-05-14 Time 10:49 Sent To B
Notes
2009-05-14 10:49:46TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-03-17 Cont ID  
Sent By adarroug Date 2009-03-17 Time 12:56 Rev Time 0.00
Received By adarroug Date 2009-03-17 Time 12:56 Sent To B
Notes
2009-03-17 12:56:23TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-02-27 Cont ID  
Sent By adarroug Date 2009-02-27 Time 16:47 Rev Time 0.00
Received By adarroug Date 2009-02-27 Time 16:47 Sent To B
Notes
2009-02-27 16:47:39TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-02-17 Cont ID  
Sent By adarroug Date 2009-02-17 Time 11:17 Rev Time 0.00
Received By adarroug Date 2009-02-17 Time 11:17 Sent To B
Notes
2009-02-17 11:19:39TO "MISC' BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-02-18 Cont ID  
Sent By rmcdouga Date 2009-02-18 Time 07:40 Rev Time 0.00
Received By rmcdouga Date 2009-02-06 Time 15:12 Sent To  
Notes
2009-02-06 15:12:51TO "Z" BOX

Review Stop Z ZONING
Rev No 3 Status P Date 2009-05-19 Cont ID  
Sent By mcruz Date 2009-05-19 Time 11:48 Rev Time 0.00
Received By mcruz Date 2009-05-19 Time 11:48 Sent To  
Notes
2009-05-19 11:48:47PASSED - AS NOTED ON PLANS, WALL SHALL NOT EXCEED
 PROPERTY LINE BOUNDARIES.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2009-03-27 Cont ID  
Sent By mcruz Date 2009-03-27 Time 11:06 Rev Time 0.00
Received By mcruz Date 2009-03-27 Time 11:02 Sent To  
Notes
2009-03-27 11:06:18PASSED - AS NOTED ON PLANS, WALL SHALL NOT EXCEED
 PROPERTY LINE BOUNDARIES.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2009-02-16 Cont ID  
Sent By mcruz Date 2009-02-16 Time 10:59 Rev Time 0.00
Received By mcruz Date 2009-02-16 Time 10:57 Sent To I
Notes
***NONE***