Plan Review Stops For Permit 09010323 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-05-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-22 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-22 |
Time |
12:12 |
Sent To |
PC |
|
Notes |
2009-05-22 12:15:01 | BUILDING REVISIONS OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-04-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-04-06 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-04-06 |
Time |
14:45 |
Sent To |
|
|
Notes |
2009-04-06 14:55:27 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- RE-SUBMIT PRODUCT APPROVAL FOR ROOF TILE ADHESIVE. | | NEED TO PROVIDE REPORT # 9822B AS SHOWN ON FLORIDA | | PRODUCT APPROVAL FL830-R1. ESR-1709 REPORT SUBMITTED | | DOESN'T CORRESPOND TO FL830-R1. | | | | 2- PROVIDE DIMENSIONS ON DETAIL 3/S-1 TO SHOW | | COMPLIANCE WITH RISER/TREAD RATIO SEC. R311.5.3.2 OF | | 2004 FLORIDA RESIDENTIAL CODE. | | | | 3- SPECIFY MIN. 8D RING SHANK NAILS ON DETAIL D-1/A-2 | | SIDE VIEW DETAIL. ALSO, REVISE ROOF SHEATHING FASTENING | | SPECIFICATIONS ON DETAIL 5/S-2 TO COMPLY WITH SEC. | | R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-02-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-02-17 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-02-17 |
Time |
16:29 |
Sent To |
M |
|
Notes |
2009-02-17 16:50:15 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST. | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | REVISIONS. | | | | 1- SHEET SP-1: | | A) DESIGN CRITERIA SPECIFIES BUILDING TO BE ON EXPOSURE | | "C", WHILE DESIGN CRITERIA ON SHEET S-1 AND SHEET S-2 | | SPECIFIES EXPOSURE "B". REVISE AS REQUIRED TO MATCH. | | AND, PROVIDE CORRESPONDING DESIGN PRESSURES. | | | | B) CLARIFY IF CONSTRUCTION TYPE IS VA OR VB. | | | | 2- SPECIFY TYPE OF EXISTING LOUVERS AND PROVIDE DETAILS | | SHOWING HOW ARE THEY GOING TO BE RE-INSTALLED | | CONSIDERING THAT NEW WINDOWS WILL BE INSTALLED ON SAME | | OPENING TO VERIFY COMPLIANCE WITH THE DESIGN LOADS OF | | SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | A) WINDOW MULLIONS. AND, CLEARLY MARK SPECIFIC MULLION | | SIZE AND ANCHORING TO VERIFY COMPLIANCE WITH THE | | CALCULATED DESIGN PRESSURES. | | | | B) ROOF TILE ADHESIVE TO BE USED. SEE PRODUCT APPROVAL | | FOR REFERENCED INFORMATION. | | | | 4- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT | | APPROVALS PRIOR TO SUBMITTAL TO THIS OFFICE. SEC. | | 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | 5- REVISE DETAIL 3/S-1 TO COMPLY WITH THE RISER/TREAD | | RATIO OF SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL | | CODE. | | | | 6- PROVIDE SPECIFICATION FOR TONGUE AND GROOVE ROOF | | SHEATHING FOR NEW CANOPY. SEC. R803.2.3.1 OF 2004 | | FLORIDA RESIDENTIAL CODE. | | | | 7- EXTERIOR ELEVATIONS CARDINAL ORIENTATION SHOWN ON | | SHEET D-2 DON'T CORRESPOND TO ORIENTATION SHOWN ON | | SHEET A-3. EG: FRONT ELEVATION IS CALLED NORTH ON SHEET | | D-2, BUT CALLED SOUTH ON SHEET A-3. REVISE ALL AS | | REQUIRED. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2009-04-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-04-28 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-04-28 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2009-01-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-01-26 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-01-26 |
Time |
07:54 |
Sent To |
Z |
|
Notes |
2009-01-26 09:24:32 | | | | | REDLINED REFERENCE TO "CITY OF LAKE WORTH" E-1, | | REFERENCE TO "EXISTING PANEL LA" SHEETS E-2, E-3, AND | | #6 GEC TO #4./WRT. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2009-01-21 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2009-01-21 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2009-01-21 |
Time |
16:07 |
Sent To |
|
|
Notes |
2009-01-21 16:07:51 | OK PER JILLIAN PAPA MMILLER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-06-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-06-09 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-06-09 |
Time |
08:42 |
Sent To |
P |
|
Notes |
2009-06-09 08:42:35 | TO P INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-05-13 |
Time |
11:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-03-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-03-30 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-03-30 |
Time |
13:39 |
Sent To |
|
|
Notes |
2009-03-30 13:42:34 | TO "R5" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-02-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-03 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-03 |
Time |
15:15 |
Sent To |
M |
|
Notes |
2009-02-03 15:16:04 | TO "SFR" "M" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-03-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-02-20 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-01-23 |
Time |
10:10 |
Sent To |
|
|
Notes |
2009-03-09 16:35:31 | KEN STEVENS CALLED FOR PICK UP. | 2009-01-23 10:10:34 | TO "SFR" "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-02-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2009-02-19 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2009-02-19 |
Time |
14:48 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2009-06-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-15 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-15 |
Time |
10:36 |
Sent To |
|
|
Notes |
2009-06-15 10:37:33 | REVISION OK -- SHTS P-3 & P-4. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-14 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-14 |
Time |
13:09 |
Sent To |
|
|
Notes |
2009-05-14 13:14:26 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | | | 1. SHTS P-3 & P-4. THE VENT FOR THE TUB/SHOWER/WATER | | CLOSET IS A DRY HORIZONTAL VENT. PER SECTION 905.4 | | EVERY DRY VENT SHALL RISE VERTICALLY TO A MINIMUM OF 6 | | INCHES ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST TRAP OR | | TRAPPED FIXTURE BEING VENTED. THE VENT SHALL RISE | | VERTICALLY TO 6 INCHES ABOVE THE TOILET FLOOD LEVEL RIM | | PRIOR TO OFFSETTING HORIZONTALLY. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-04-28 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-04-28 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-04-28 |
Time |
11:37 |
Sent To |
|
|
Notes |
2009-04-28 11:39:16 | | | | | | | PASSED/PROVISO | | | | SHTS P-3 & P-4 PLUMBING 2ND FLOOR & SANITARY RISER | | DIAGRAM SHOWS A HORIZONTAL DRY VENT UPSTREAM OF THE TUB | | & SHOWER. THIS IS PROHIBITED BY SECTIONS 905.3 & 905.4. | | REVISION REQUIRED. | | | | | | | | | | | | | | . |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-02-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-02-20 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-02-20 |
Time |
16:07 |
Sent To |
|
|
Notes |
2009-02-20 16:12:58 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | | | 1. SHTS P-3 & P-4 PLUMBING 2ND FLOOR & SANITARY RISER | | DIAGRAM SHOWS A HORIZONTAL DRY VENT UPSTREAM OF THE TUB | | & SHOWER. THIS IS PROHIBITED BY SECTIONS 905.3 & 905.4. | | (SEE RED LINE EXAMPLE TO CORRECT VENT). | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-04-23 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-04-23 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-04-22 |
Time |
09:26 |
Sent To |
E |
|
Notes |
2009-04-23 09:30:53 | ROUTED TO BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2009-02-01 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-02-01 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-02-01 |
Time |
15:10 |
Sent To |
I |
|
Notes |
|
|