Plan Review Stops For Permit 09010310 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2009-08-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-08-11 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-08-11 |
Time |
16:26 |
Sent To |
|
|
Notes |
2009-08-11 16:31:34 | BUILDING REVIEW FOURTH CHECKLIST. | | 2004 FBC WITH 2007 REVISIONS. | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. | | ***NOTE: THIS MAY BE PROVIDED AT TIME OF PERMIT PICK | | UP. | | | | 2- WOMEN TOILET ROOM DOESN'T COMPLY WITH SEC. 11-4.22. | | TOILET ROOM PROVIDED DOESN'T PROVIDE THE UNOBSTRUCTED | | TURNING SPACE COMPLYING WITH SEC. 11-4.2.3. | | | | 3- DOOR LEADING TO WOMEN TOILET ROOM DOESN'T COMPLY | | WITH SEC. 11-4.13.5. NEED MINIMUM CLEAR OPENING OF 32". | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2009-05-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-29 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-29 |
Time |
09:45 |
Sent To |
|
|
Notes |
2009-05-29 10:03:20 | MOTOR VEHICLE SHOWROOM (B), BUILDING REVIEW THIRD | | CHECKLIST. | | REVIEW UNDER 2004 FBC WITH 2007 REVISIONS. | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | BY SEC. 713.13 FLORIDA STATUTE. | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | 2- ORIGINAL COMMENT: MEN TOILET ROOM NEEDS TO COMPLY | | WITH CHAPTER 11 FBC 2004 SEC. 11-4.1.3(11). IF TOILETS | | ARE PROVIDED THEN BOTH MEN AND WOMEN NEED TO COMPLY. | | RESPONSE SAYING THAT HANDICAPPED TOILET ROOM FOR MEN IS | | ON ANOTHER AREA DOESN'T PROVIDE EQUALITY FOR EVERYBODY. | | CODE SECTION REQUIRES EACH TOILET ROOM TO COMPLY. | | | | *** ARCHITECT'S RESPONSE TO THIS COMMENT: "MEN'S TOILET | | HAS BEEN REMOVED AS PER BUILDING DEPARTMENT | | REQUIREMENT". | | | | CLARIFICATION: IT IS NOT THE BUILDING DEPARTMENT | | REQUIREMENT TO REMOVE THE MEN'S TOILET. IF TOILETS ARE | | PROVIDED, THEN BOTH NEED TO COMPLY WITH SEC. | | 11-4.1.3(11) OF 2004 FBC. PLANS NOW SHOW ONLY TOILET | | ROOM FOR WOMEN. NEED TO PROVIDE TOILET ROOM FOR MEN | | ALSO AND BOTH NEED TO BE ADA COMPLIANT. ANOTHER | | SOLUTION MAY BE TO PROVIDE UNISEX TOILET. CHECK WITH | | THE PLUMBING CODE FOR REQUIRED NUMBER OF FIXTURES. | | REVISE PLANS AS REQUIRED. | | | | 3- NEED TO PROVIDE TURNING AREA AT THE KITCHENETTE AREA | | TO COMPLY WITH SEC. 11-4.2.3 FBC 2004. T-SHAPED SPACE | | SHOWN IS OUTSIDE THE KITCHENETTE AREA. NEED TO PROVIDE | | TURNING AREA INSIDE THE KITCHENETTE AREA. OTHERWISE A | | PERSON USING A WHEELCHAIR NEEDS TO REVERSE TO GET OUT. | | | | REVISED PLAN STILL DOESN'T PROVIDE TURNING AREA. | | HANDICAPPED PERSON USING THE REFRIGERATOR STILL HAS TO | | BACK UP ALL THE WAY BACK. THERE IS NO TURNING AREA | | PROVIDED IN THIS AREA. TURNING AREA IS STILL PROVIDED | | OUTSIDE THE KITCHENETTE AREA, NOT INSIDE. REVISE PLANS | | AS REQUIRED. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-03-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-03-30 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-03-30 |
Time |
13:55 |
Sent To |
|
|
Notes |
2009-03-30 15:30:46 | MOTOR VEHICLE SHOWROOM (B), BUILDING REVIEW SECOND | | CHECKLIST. | | REVIEW UNDER 2004 FBC WITH 2007 REVISIONS. | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | BY SEC. 713.13 FLORIDA STATUTE. | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | 2- MEN TOILET ROOM NEEDS TO COMPLY WITH CHAPTER 11 FBC | | 2004 SEC. 11-4.1.3(11). IF TOILETS ARE PROVIDED THEN | | BOTH MEN AND WOMEN NEED TO COMPLY. RESPONSE SAYING THAT | | HANDICAPPED TOILET ROOM FOR MEN IS ON ANOTHER AREA | | DOESN'T PROVIDE EQUALITY FOR EVERYBODY. CODE SECTION | | REQUIRES EACH TOILET ROOM TO COMPLY. | | | | 3- DOOR LEADING TO THE WOMEN TOILET ROOM DOESN'T COMPLY | | WITH MANEUVERING CLEARANCES AT DOORS AS REQUIRED BY | | SEC. 11-4.13.6 FBC 2004 AND FIGURE 25. PULL SIDE | | REQUIRES 60" MIN. REVISE AS REQUIRED. | | | | 4- SHEET A-105. CLARIFY WHAT IS THE DOTTED LINE SHOWN | | ON SECTION-B OF HC SINK AT KITCHENETTE COUNTER DETAIL | | FOR. | | | | 5- NEED TO PROVIDE TURNING AREA AT THE KITCHENETTE AREA | | TO COMPLY WITH SEC. 11-4.2.3 FBC 2004. T-SHAPED SPACE | | SHOWN IS OUTSIDE THE KITCHENETTE AREA. NEED TO PROVIDE | | TURNING AREA INSIDE THE KITCHENETTE AREA. OTHERWISE A | | PERSON USING A WHEELCHAIR NEEDS TO REVERSE TO GET OUT. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-01-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-01-27 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-01-27 |
Time |
10:55 |
Sent To |
|
|
Notes |
2009-01-27 11:00:07 | MOTOR VEHICLE SHOWROOM (B), BUILDING REVIEW CHECKLIST. | | REVIEW UNDER 2004 FBC WITH 2007 REVISIONS. | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | BY SEC. 713.13 FLORIDA STATUTE. SEE ITEM #10 BELOW FOR | | CORRECT ADDRESS AND PARCEL ID NUMBER INFORMATION. | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | 2- CLEAR FLOOR SPACE OF WOMEN HANDICAPPED RESTROOM | | DOESN'T COMPLY WITH SEC. 11-4.22.3 FBC 2004. THERE IS | | NOT AN UNOBSTRUCTED TURNING SPACE COMPLYING WITH SEC. | | 11-4.2.3. | | | | 3- SPECIFY ALL DIMENSIONS ON WOMEN HANDICAPPED TOILET | | RESTROOM TO VERIFY COMPLIANCE WITH ALL MINIMUM | | CLEARANCES REQUIRED BY CHAPTER 11 FBC 2004. | | | | 4- CLARIFY WHY THE MEN'S TOILET ROOM IS NOT DESIGNED TO | | COMPLY WITH CHAPTER 11 FBC 2004 SEC. 11-4.1.3(11). | | | | 5- SPECIFY ALL DIMENSIONS FOR OFFICE NEXT TO THE | | KITCHENETTE TO VERIFY CLEARANCES BETWEEN COUNTERS. SEC. | | 11-4.3 FBC 2004. | | | | 6- SPECIFY ALL DIMENSIONS NEXT TO THE DOORS TO VERIFY | | COMPLIANCE WITH MANEUVERING CLEARANCES AT DOORS AS | | REQUIRED BY SEC. 11-4.13.6 FBC 2004. CHECK DOOR THAT | | PROVIDES ACCESS TO THE WOMENS TOILET ROOM. THERE IS NO | | ENOUGH ROOM. ALSO, CHECK DOOR IN OFFICE NEXT TO THE | | KITCHENETTE AREA. | | | | 7- UPPER CABINETS SHOWN ON OFFICE NEXT TO THE | | KITCHENETTE AREA AND IN THE KITCHENETTE AREA NEED TO | | COMPLY WITH SEC. 11-4.25.3. FBC 2004. | | | | 8- SHEET A-103: PROPOSED OPENING DETAIL SPECIFIES THAT | | MAXIMUM OPENING TO BE 50", WHILE SHEET A-101 SPECIFIES | | OPENING TO BE 4'-6" X 7'-2". REVISE AS REQUIRED TO | | MATCH. | | ***NOTE: COORDINATE OPENING DIMENSIONS WITH REQUIRED | | CLEARANCE FOR DOOR MANEUVERING. SEE ITEM #5 ABOVE. | | | | 9- SHEET A-105: KITCHENETTE SINK DIMENSIONS TO COMPLY | | WITH SEC. 11-4.24.3 (KNEE CLEARANCE), 11-4.24.4 (SINK | | DEPTH) AND SEC. 11-4.24.5 (CLEAR FLOOR SPACE UNDERNEATH | | THE SINK). REVISE AS REQUIRED. | | | | 10- CLARIFY TYPE OF HARDWARE FOR ALL ACCESSIBLE DOORS | | TO REVIEW COMPLIANCE WITH SEC. 11-4.13.9 FBC 2004. DOOR | | TYPES SHOWN ON DOOR SCHEDULE ON SHEET A-106 DON'T SHOW | | APPROVED TYPE OF HARDWARE. THEY SHOW TWISTING HANDLES. | | REVISE/CLARIFY SPECIFICATIONS AND DRAWINGS AS REQUIRED. | | | | 11- CLARIFY ADDRESS OF BUILDING. ACCORDING TO THE | | PROPERTY APPRAISAL WEBSITE, THERE ARE THREE DIFFERENT | | BUILDING WITH THREE DIFFERENT ADDRESSES THAT ARE OWNED | | BY THE SAME OWNER. BUILDING WHERE WORK IS TAKEN PLACE | | IS THE 901 S. DIXIE HWY, NOT 915 S. DIXIE HWY. SEE | | ATTACHED COPY OF PROPERTY APPRAISAL AERIAL VIEW. REVISE | | ADDRESS ON PLANS AND PERMIT APPLICATION AS REQUIRED. | | ***NOTE: PLEASE MAKE SURE CORRECT PARCEL ID NUMBER IS | | USED ON PERMIT APPLICATION TO AVOID ANY CONFLICTS OR | | DELAYS. ALSO, INFORMATION ON NOTICE OF COMMENCEMENT | | NEED TO MATCH ACCORDINGLY. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-28 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-04-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-04-15 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-04-15 |
Time |
08:46 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-02-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-02-06 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-02-06 |
Time |
07:15 |
Sent To |
I |
|
Notes |
2009-02-06 10:17:03 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2006, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} INDICATE CIRCUIT NUMBERS SOR THE LIGHTING CIRCUITS | | SHOWN ON SHEET E-102. 106.3.5 FBC AS AMENDED. | | | | 2} THE LPD OF 1.2 W/SQ.FT FOR THE CORRIDOR DENSITY IS | | INCORRECT PER 13-415.2.B WHICH LISTS CORRIDORS @ 0.5 | | ALLOWED W/SQ.FT. SHEET E-102. | | | | 3} PROVIDE A PANEL SCHEDULES FOR THE REMODEL AREA | | CIRCUITING PER 408.4 NEC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-05-27 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-05-27 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-05-27 |
Time |
15:41 |
Sent To |
|
|
Notes |
2009-05-27 16:00:59 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED; PLAN SHEETS A-101, A-102, E-101, & | | E-102 WERE STAMPED, INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2009-04-07 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-04-07 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-04-07 |
Time |
13:55 |
Sent To |
|
|
Notes |
2009-04-07 14:02:09 | *****PROVISO***** | | | | | | 1. ON SHEET A-101, AMEND INFORMATION (NEW INTERIOR WALL | | CEILING FINISH) TO REFLECT THAT THE 2006 EDITION OF | | NFPA 101- LIFE SAFETY CODE - IS REFERENCED. (BE ADVISED | | THAT THE CHANGE OF EDITIONS WENT INTO EFFECT AS OF | | 12/31/2008.) | | | | THE APPROPIATE PLAN SHEETS ( A-101, A-102, E-101, & | | E-102) TO BE FIRE-STAMPED WHEN THE ABOVE COMMENT AS | | WELL AS THE OTHER PLAN EXAMINERS' COMMENTS HAVE BEEN | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2009-02-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-02-02 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-02-02 |
Time |
15:14 |
Sent To |
|
|
Notes |
2009-02-02 15:35:01 | *****UNSAT***** | | | | | | 1. ON SHEETS A-100 AND A-101, AMEND INFORMATION TO | | REFLECT THAT THE 2006 EDITION OF NFPA 101- LIFE SAFETY | | CODE - IS REFERENCED. (BE ADVISED THAT THE CHANGE OF | | EDITIONS WENT INTO EFFECT AS OF 12/31/2008.) | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | THE ABOVE COMMENT AS WELL AS THE OTHER PLAN EXAMINERS' | | COMMENTS HAVE BEEN ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-07-22 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-07-22 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-07-22 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
P |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-28 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-13 |
Time |
10:10 |
Sent To |
|
|
Notes |
2009-05-13 10:10:50 | INCOMING TO C-4 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-03-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2009-03-12 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2009-03-12 |
Time |
09:32 |
Sent To |
|
|
Notes |
2009-03-12 09:32:23 | TO "BOB"#1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-02-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-02-06 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-01-23 |
Time |
10:30 |
Sent To |
PC |
|
Notes |
2009-01-23 10:32:44 | TO "BOB"#12 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-08-05 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-08-05 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-08-05 |
Time |
08:30 |
Sent To |
|
|
Notes |
2009-08-05 08:44:41 | PREVIOUSLY PASSED PAGE M101 REPLACED BY REVISION DELTA | | 5. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-02-05 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-02-05 |
Time |
20:14 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-02-05 |
Time |
20:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2009-08-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-08-10 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-08-10 |
Time |
14:00 |
Sent To |
|
|
Notes |
2009-08-13 10:20:41 | DENIED | | REFERENCE: | | FBC-2004 CHAPTER 11 | | | | 1. PLANS AS SUBMITTED INDICATE 2 SEPARATE TOILET ROOMS. | | PER SECTION 11-4.1.3(11) EACH TOILET ROOM SHALL BE | | ACCESSIBLE. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2009-05-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-22 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-22 |
Time |
09:13 |
Sent To |
|
|
Notes |
2009-05-22 09:18:52 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | ****FROM PREVIOUS REVIEW: | | | | ******FROM PREVIOUS REVIEWS: | | | | 1. OK | | | | 2. SHT A-101 SUBMIT DETAILS/ELEVATIONS SHOWING | | COMPLIANCE WITH THE FOLLOWING: | | | | A. DRINKING FOUNTAIN | | 1. 11-4.15 WITH ALL SUBSECTIONS AS WELL AS SECTION | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. | | ****RESPONSE NOTED, BUT COMMENT CONSERNING SECTION | | 11-4.1.3(10)(A) NOT ADDRESSED. | | ******RESPONSE NOTED, BUT COMMENT CONSERNING SECTION | | 11-4.1.3(10)(A) STILL NOT ADDRESSED. | | | | B. OK (DELETED) | | | | C. STALLS | | 1. 11-4.17.3 SIZE & ARRANGEMENT EXCEPTION (1)(2) LAV | | REQUIRED IN STALL. (SEE FIGURE 30(E)). | | ****RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PER | | SECTION 11-4.1.6(1)(B) IF EXISTING ELEMENTS, SPACES, OR | | COMMON AREAS ARE ALTERED, THEN EACH SUCH ALTERED | | ELEMENT, SPACE, FEATURE, OR AREA SHALL COMPLY WITH THE | | APPLICABLE PROVISIONS OF SECTION 11-4.1.1 TO SECTION | | 11-4.1.3, MINIMUM REQUIREMENTS FOR NEW CONSTRUCTION. AS | | SUCH THE LAV IS REQUIRED. THE COMMENT RESPONSE | | INDICATES THAT ON PERMIT NUMBERS 07080049 & 07110548 I | | HAD COMPLETED THE REVIEWS AND THAT I HAD VERIFIED WITH | | THE BUILDING OFFICIAL. PLAN REVIEWER MIKE PERSON | | FINISHED THE REVIEW FOR PERMIT 07080049 IN WHICH I HAD | | INDICATED THE REQUIRMENT FOR THE LAV. MIKE PERSON ALSO | | DID THE REVIEW FOR PERMIT 07110548. IF THERE IS AN | | EXCEPTION TO THE REQUIREMENT PLEASE SUBMIT THE | | EXCEPTION. THE E-MAIL WAS NOT FROM ME SO I AM NOT | | FAMILIAR WITH THE E-MAIL. | | ****RESPONSE NOTED, BUT COMMENT RESPONSE "MEN'S TOILET | | HAS BEEN REMOVED FROM THE PLANS AS PER BUILDING | | DEPARTMENT REQUIRMENT" DOES NOT ADDRESS THE COMMENT AND | | REMOVAL OF THE MEN'S TOILET ROOM HAS NEVER BEEN A | | REQUIREMENT. THE ONLY REQUIREMENT WAS THAT THE MEN'S | | TOILET ROOM BE ACCESSIBLE. | | | | D. OK | | | | F. TOILET ROOMS | | 1. OK (DELETED) | | 3. OK (DELETED) | | OK | | 4. OK | | 5. OK | | 6. OK | | 7. OK | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2009-04-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-04-01 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-04-01 |
Time |
14:54 |
Sent To |
|
|
Notes |
2009-04-01 16:28:14 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | ****FROM PREVIOUS REVIEW: | | | | 1. OK | | | | 2. SHT A-101 SUBMIT DETAILS/ELEVATIONS SHOWING | | COMPLIANCE WITH THE FOLLOWING: | | | | A. DRINKING FOUNTAIN | | 1. 11-4.15 WITH ALL SUBSECTIONS AS WELL AS SECTION | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. | | ****RESPONSE NOTED, BUT COMMENT CONSERNING SECTION | | 11-4.1.3(10)(A) NOT ADDRESSED. | | | | B. W/C'S | | 1. 11-4.16.4 GRAB BARS (NOT SHOWN IN MEN'S TOILET | | ROOM). | | ****RESPONSE NOTED, BUT THE DEMO SHEET DOES NOT SHOW | | THE MENS TOILET ROOM AS EXISTING SO THIS IS A NEW | | TOILET ROOM AND AS SUCH PER SECTION 11-4.1.3(11) IF | | TOILET ROOMS ARE PROVIDED, THEN EACH TOILET ROOM SHALL | | COMPLY WITH SECTION 11-4.22. SECTION 11-4.1.6((1)(B). | | COMMENT NOT ADDRESSED. | | | | C. STALLS | | 1. 11-4.17.3 SIZE & ARRANGEMENT EXCEPTION (1)(2) LAV | | REQUIRED IN STALL. (SEE FIGURE 30(E)). | | ****RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PER | | SECTION 11-4.1.6(1)(B) IF EXISTING ELEMENTS, SPACES, OR | | COMMON AREAS ARE ALTERED, THEN EACH SUCH ALTERED | | ELEMENT, SPACE, FEATURE, OR AREA SHALL COMPLY WITH THE | | APPLICABLE PROVISIONS OF SECTION 11-4.1.1 TO SECTION | | 11-4.1.3, MINIMUM REQUIREMENTS FOR NEW CONSTRUCTION. AS | | SUCH THE LAV IS REQUIRED. THE COMMENT RESPONSE | | INDICATES THAT ON PERMIT NUMBERS 07080049 & 07110548 I | | HAD COMPLETED THE REVIEWS AND THAT I HAD VERIFIED WITH | | THE BUILDING OFFICIAL. PLAN REVIEWER MIKE PERSON | | FINISHED THE REVIEW FOR PERMIT 07080049 IN WHICH I HAD | | INDICATED THE REQUIRMENT FOR THE LAV. MIKE PERSON ALSO | | DID THE REVIEW FOR PERMIT 07110548. IF THERE IS AN | | EXCEPTION TO THE REQUIREMENT PLEASE SUBMIT THE | | EXCEPTION. THE E-MAIL WAS NOT FROM ME SO I AM NOT | | FAMILIAR WITH THE E-MAIL. | | | | D. OK | | | | F. TOILET ROOMS | | 1. 11-4.22.3 UNOBSTRUCTED TURNING AREA REQUIRED. (NOT | | SHOWN IN MEN'S TOILET ROOM). | | ****RESPONSE NOTED, BUT SINCE THIS IS A NEW TOILET ROOM | | IT SHALL BE ACCESSIBLE. SECTION 11-4.1.6(1)B). | | | | 3. MEN'S TOILET ROOM SHALL BE ACCESSIBLE. SECTION | | 11-4.1.6(1)(B). | | ****RESPONSE NOTED, BUT ALL TOILET ROOMS PROVIDED SHALL | | COMPLY WITH SECTION 11-4.22. | | | | 4. A TURNING AREA IS REQUIRED AT THE KITCHENETTE. | | SECTION 11-4.2.3. | | ****RESPONSE NOTED, BUT THE TURNING AREA IS REQUIRED | | "IN" THE KITCHENETTE, NOT OUTSIDE THE KITCHENETTE. | | | | 5. OK | | 6. OK | | 7. OK | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2009-02-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-02-04 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-02-04 |
Time |
14:22 |
Sent To |
|
|
Notes |
2009-02-04 14:43:50 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | 1. SHT A-101 REFERENCES DETAILED FIXTURE & ACCESSORIES | | ON SHEET A-104, BUT NO FIXTURES AND ACCESSORIES WERE | | FOUND. PLEASE CLARIFY & CORRELATE. SECTION 106.1.1 & | | CHAPTER 11. | | | | 2. SHT A-101 SUBMIT DETAILS/ELEVATIONS SHOWING | | COMPLIANCE WITH THE FOLLOWING: | | | | A. DRINKING FOUNTAIN | | 1. 11-4.15 WITH ALL SUBSECTIONS AS WELL AS SECTION | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. | | | | B. W/C'S | | 1. 11-4.16.4 GRAB BARS (NOT SHOWN IN MEN'S TOILET | | ROOM). | | | | C. STALLS | | 1. 11-4.17.3 SIZE & ARRANGEMENT EXCEPTION (1)(2) LAV | | REQUIRED IN STALL. (SEE FIGURE 30(E)). | | | | D. LAV'S | | 1. 11-4.19.2 CLEARANCE (29"). | | | | F. TOILET ROOMS | | 1. 11-4.22.3 UNOBSTRUCTED TURNING AREA REQUIRED. (NOT | | SHOWN IN MEN'S TOILET ROOM). | | | | 3. MEN'S TOILET ROOM SHALL BE ACCESSIBLE. SECTION | | 11-4.1.6(1)(B). | | | | 4. A TURNING AREA IS REQUIRED AT THE KITCHENETTE. | | SECTION 11-4.2.3. | | | | 5. SUBMIT A WATER ISOMETRIC RISER DIAGRAM REQUIRED BY | | SECTION 106.3.5.1.3(3)(5)(8)(10)(13). SHOW ALL PIPE | | SIZES, VALVES, WATER HEATER, THERMAL EXPANSION CONTROL, | | WATER HAMMER ARRESTORS & RPZV BACKFLOW PREVENTOR. | | SECTIONS 604.1, 604.9, 606.1, 606.2, 607.13.2 & | | 608.13.2. | | | | 6. SHT P-102 PLUMBING SPECIFICATIONS 2(A) CODES TO | | INCLUDE THE 2007 AMENDMENTS TO THE FBC-2004 PLUMBING | | CODE. THE STANDARD CODE IS NOT ADOPTED. PLEASE DELETE | | REFERENCE TO STANDARD CODE. SECTION 106.1.2 | | | | 7. SHT P-102 PLUMBING SPECIFICATIONS 5(F) AIR CHAMBERS | | ARE NOT APPROVED. PLEASE DELETE REFERENCE. SECTION | | 604.9 AND PDI-WH 201. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|