Plan Review Details - Permit 08120235
Plan Review Stops For Permit 08120235
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-01-16 Cont ID  
Sent By mjacobs Date 2009-01-16 Time 09:05 Rev Time 0.00
Received By mjacobs Date 2009-01-16 Time 09:05 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-12-31 Cont ID  
Sent By mjacobs Date 2008-12-31 Time 09:00 Rev Time 0.00
Received By mjacobs Date 2008-12-31 Time 09:00 Sent To PC
Notes
2008-12-31 09:00:00BUILDING PLAN REVIEW
 PERMIT: 08120235
 ADD: 2685 PAW PAW CAY
 CONT: SCREEN BUILDERS
 TEL: (561)793-6029
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 12/31/08
 REVIEW: 2ND
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 **SECOND REVIEW**
 2) THE SHEET WITH THE ELEVATION DRAWINGS STATES THE
 EXPOSURE CATEGORY AS 'B', HOWEVER, EXPOSURE 'C' APPLY
 TO ANY BUILDING LOCATED WITHIN EXPOSURE 'B' WHERE THE
 BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF EXPOSURE
 'C' TYPE TERRAIN AND ANY QUADRANT FOR A DISTANCE OF
 MORE THAN 600 FEET. THE LOCATION OF THE STRUCTURE SEEMS
 TO FALL IN EXPOSURE 'C' CATEGORY. FBC 1609.4(3)
 R301.2.1.4 EXPOSURE CATEGORY. (3). EXPOSURE C. OPEN
 TERRAIN WITH SCATTERED OBSTRUCTIONS, INCLUDING SURFACE
 UNDULATIONS OR OTHER IRREGULARITIES, HAVING HEIGHTS
 GENERALLY LESS THAN 30 FEET (9144 MM) EXTENDING MORE
 THAN 1,500 FEET (457.2 M) FROM THE BUILDING SITE IN ANY
 QUADRANT. THIS EXPOSURE SHALL ALSO APPLY TO ANY
 BUILDING LOCATED WITHIN EXPOSURE B-TYPE TERRAIN WHERE
 THE BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF
 EXPOSURE C-TYPE TERRAIN IN ANY QUADRANT FOR A DISTANCE
 OF MORE THAN 600 FEET (182.9 M). SHORT-TERM (LESS THAN
 TWO YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE,
 FOR THE PURPOSES OF DEVELOPMENT, SHALL NOT BE
 CONSIDERED OPEN FIELDS. WHERE DEVELOPMENT BUILD OUT
 WILL OCCUR WITHIN THREE YEARS AND THE RESULTANT
 CONDITION WILL MEET THE DEFINITION OF EXPOSURE B,
 EXPOSURE B SHALL BE REGULATING FOR THE PURPOSE OF
 PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY,
 GRASSLANDS AND OCEAN OR GULF SHORELINES. THIS CATEGORY
 DOES NOT INCLUDE INLAND BODIES OF WATER THAT PRESENT A
 FETCH OF 1 MILE (1.61 KM) OR MORE OR INLAND WATERWAYS
 OR RIVERS WITH A WIDTH OF 1 MILE (1.61 KM) OR MORE (SEE
 EXPOSURE D). PLEASE SEE ADDITIONAL CODE INFORMATION
 ATTACHED REGARDING EXPOSURE 'C' INCLUDING THE AREAL
 PHOTO WHICH SHOWS THE SHORTEST DISTANCE AT 648 FEET TO
 THE NEAREST STRUCTURE.
  
 3) OK
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-12-16 Cont ID  
Sent By mjacobs Date 2008-12-16 Time 08:15 Rev Time 0.00
Received By mjacobs Date 2008-12-16 Time 07:41 Sent To PC
Notes
2008-12-16 10:53:07BUILDING PLAN REVIEW
 PERMIT: 08120235
 ADD: 2685 PAW PAW CAY
 CONT: SCREEN BUILDERS
 TEL: (561)793-6029
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 12/16/08
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) THE SHEET WITH THE ELEVATION DRAWINGS STATES THE
 EXPOSURE CATEGORY AS 'B', HOWEVER, EXPOSURE 'C' APPLY
 TO ANY BUILDING LOCATED WITHIN EXPOSURE 'B' WHERE THE
 BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF EXPOSURE
 'C' TYPE TERRAIN AND ANY QUADRANT FOR A DISTANCE OF
 MORE THAN 600 FEET. THE LOCATION OF THE STRUCTURE SEEMS
 TO FALL IN EXPOSURE 'C' CATEGORY. FBC 1609.4(3)
  
 3) IF THE SCREEN ENCLOSURE HAS DOORS WHICH LEAD TO A
 POOL, THEY SHALL BE EQUIPPED WITH SELF-CLOSING;
 SELF-LATCHING LOCKING DEVICE LOCATED NOT LESS THAN 54
 INCHES FROM THE BOTTOM OF THE GATE. FBC
 424.2.17.1.9(2). SHOW COMPLIANCE ON THE DRAWINGS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-01-14 Cont ID  
Sent By adarroug Date 2009-01-14 Time 16:01 Rev Time 0.00
Received By adarroug Date 2009-01-14 Time 16:01 Sent To B
Notes
2009-01-14 16:03:22TO "MJACOBS" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-12-24 Cont ID  
Sent By adarroug Date 2008-12-24 Time 09:36 Rev Time 0.00
Received By adarroug Date 2008-12-24 Time 09:36 Sent To Z
Notes
2008-12-24 09:36:42TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-15 Cont ID  
Sent By adarroug Date 2008-12-15 Time 09:52 Rev Time 0.00
Received By adarroug Date 2008-12-15 Time 09:52 Sent To B
Notes
2008-12-15 09:52:40TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-12-16 Time   Rev Time 0.00
Received By adarroug Date 2008-12-11 Time 08:49 Sent To  
Notes
2008-12-11 08:49:40TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2008-12-30 Cont ID  
Sent By mcruz Date 2008-12-30 Time 13:00 Rev Time 0.00
Received By mcruz Date 2008-12-30 Time 12:56 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-12-12 Cont ID  
Sent By mcruz Date 2008-12-12 Time 16:36 Rev Time 0.00
Received By mcruz Date 2008-12-12 Time 16:33 Sent To I
Notes
2008-12-12 16:36:22PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. INDICATE ON PLAN/SURVEY THAT THE SCREEN ENCLOSURE
 WILL MEET THE FOLLOWING PROVISION. PURSUANT TO THE CITY
 OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SECTION, 94-304(D)(2)(B)+(C):
 B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT
 LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN
 ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH
 AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL
 BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved