Plan Review Details - Permit 08120182
Plan Review Stops For Permit 08120182
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-01-14 Cont ID  
Sent By shill Date 2009-01-14 Time 17:26 Rev Time 0.00
Received By shill Date 2009-01-14 Time 17:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-01-14 Cont ID  
Sent By shill Date 2009-01-14 Time 17:13 Rev Time 0.00
Received By shill Date 2009-01-14 Time 17:13 Sent To  
Notes
2009-01-14 17:25:48****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PLLEASE SEE INSTALLATION SCHEDULE. IN THE COLUMN FOR
 "SPECIFIC ANCHOR TYPE", THE CONNECTION TYPE HAS BEEN
 WRITTEN (C2). THIS INFORMATION SHOULD BE IN THE FOURTH
 COLUMN, AND THIS COLUMN SHOULD SPECIFY THE SPECIFIC
 ANCHOR TYPE; IN THIS CASE, TAPCONS.
  
 2. WHEN SPECIFYING TAPCONS, IF THE PRODUCT APPROVAL
 PROVIDES MORE THAN ONE CHOICE, PLEASE SPECIFY WHICH
 TYPE OF TAPCON. THE PRODUCT APPROVAL FOR ACCORDIONS
 INCLUDES BOTH ITW AND ELCO TAPCON.
  
 3. 1 3/4" TAPCON SPECIFIED; PLEASE NOTE THAT THIS IS
 THE EMBEDMENT REQUIREMENT. A LONGER TAPCON MUST BE
 SPECIFIED DUE TO STUCCO AND OTHER FACTORS SUCH AS TRACK
 OR PANEL THICKNESS.
  
 4. SEE SHEET 6 OF THE ACCORDION PRODUCT APPROVAL.
 SEVERAL NUMBERS CIRCLED, MOST WHICH DO NOT APPLY TO
 THIS JOB. ALSO SEE SHEET3; BUILDOUT DETAIL CIRCLED BUT
 THIS IS NOT SPECIFIED ON THE INSTALLATION SCHEDULE. IF
 DETAILS ON THE PRODUCT APPROVAL ARE CIRCLED, THIS
 ASSISTS WITH BOTH PLAN REVIEW AND INSPECTIONS BUT
 SHOULD CORRELATE WITH THE INSTALLATION SCHEDULE AND THE
 JOB.
  
 5. CONCRETE SUBSTRATE SPECIFIED. SEE SHEET 6 OF THE
 ACCORDION PRODUCT APPROVAL. FOR THE ELCO TAPCON,
 3320PSI MINIMUM CONCRETE STRENGTH REQUIRED. IF USING
 THE ANCHOR SPACING FOR A CONCRETE SUBSTRATE, CONTRACTOR
 IS TO PROVIDE EVIDENCE THAT THE SUBSTRATE MEETS THIS
 REQUIREMENT. ALTERNATIVELY, THE CONTRACTOR CAN USE THE
 HOLLOW BLOCK CHART ANCHOR SPACING ON SHEET 7.
  
 6. CONTRACTOR HAS SPECIFIED ANCHOR SPACING WHICH
 EXCEEDED THE REQUIREMENTS FOR BOTH CONCRETE AND HOLLOW
 BLOCK FOR BOTH TYPES OF TAPCONS. THEREFORE, THE PLAN
 WILL BE REDLINED FOR ITEM #3.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-12-16 Cont ID  
Sent By shill Date 2008-12-16 Time 11:43 Rev Time 0.00
Received By shill Date 2008-12-16 Time 11:43 Sent To  
Notes
2008-12-16 11:44:04****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____ 1. PROVIDE BUILDING HEIGHT ON THE PLAN. DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT
 OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16.
  
 _XX_ 2. COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR
 PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS
 REQUIRED.
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 ____ 3. FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____ 4. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4.
  
 ____ 5. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS
 WILL BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH
 THE INSTALLATION SCHEDULE, ITEM 2 ABOVE. FBC R301,
 FBC1609, FBC*106.
  
 ____ 6. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE
 FOR EXPOSURE B. NOTE THAT THE DEFINITION FOR EXPOSURE C
 HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-12-16 Cont ID  
Sent By shill Date 2008-12-16 Time 11:44 Rev Time 0.00
Received By shill Date 2008-12-09 Time 08:54 Sent To  
Notes
2008-12-09 08:54:34TO "MISC" BOX#1