Plan Review Stops For Permit 08120128 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-02-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-02-19 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-02-19 |
Time |
11:17 |
Sent To |
|
|
Notes |
2009-02-19 11:21:32 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- CLARIFY WHICH SHUTTERS PRODUCT APPROVAL IS GOING TO | | BE USED. FLORIDA PRODUCT APPROVAL FL 722 OR NOA | | 06-0110.04. FLORIDA PRODUCT APPROVAL FL722 IS MISSING | | THE DRAWINGS. | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | SELECTED PRODUCT APPROVAL AS REQUIRED BY SEC. 106.3.3 | | CITY AMENDMENTS TO FBC 2004. | | 3- A) PROVIDE COMPLETE INSTALLATION SCHEDULE FOR STORM | | SHUTTERS. | | B) CLEARLY MARK ON SHUTTERS DRAWINGS SPECIFIC MOUNTING | | CONDITIONS (EG: WALL MOUNTED, BUILT OUT, ETC) AND | | ANCHOR TYPE AND SPACING TO BE USED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-02-10 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-02-10 |
Time |
14:03 |
Sent To |
PC |
|
Notes |
2009-02-10 14:59:28 | RESIDENTIAL (R3) REPAIRS, BUILDING REVIEW SECOND | | CHECKLIST. | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | REVISIONS. | | | | 1- FLOOR PLANS SPECIFY EXISTING 33"X40" SINGLE HUNG | | WINDOWS TO REMAIN AS IS. CONTRACTOR STATES THAT WINDOWS | | ARE GOING TO BE REPLACED. REVISE PLANS AS REQUIRED. | | ***NOTE: IF WINDOWS ARE NOT TO BE REPLACED, THEN WHY | | ENGINEER IS APPROVING PRODUCT APPROVAL FOR WINDOWS AND | | SHUTTERS?. | | | | 2- REVISE WIND INFORMATION ON SHEET A1: | | A) DESIGN PRESSURES FOR DOORS AND WINDOWS ARE MISSING. | | THERE IS NOT SHEET A-2. | | | | B) PROVIDE ACTUAL ROOF CLADDING CALCULATIONS. SPECIFY | | TRIBUTARY AREA AND REVISE DIMENSION FOR ROOF ZONE 2 AND | | 3. SEE FOOTNOTE "A" ON FIGURE R301.2(8) OF 2004 FLORIDA | | RESIDENTIAL CODE FOR MINIMUM REQUIRED DIMENSIONS. | | | | ***NOTE: CLARIFY WHY PROVIDING ROOF CLADDING PRESSURES | | IF NOT WORK IS TO BE DONE ON THE ROOF. | | | | 3- PRODUCT APPROVAL FOR SHUTTERS FL722 AND NOA | | 06-0110.04 SUBMITTED DON'T CORRESPOND TO EACH OTHER. IF | | USING FL722, THEN NEED TO PROVIDE COMPLETE SET OF | | DRAWINGS THAT WERE APPROVED FOR THIS PRODUCT APPROVAL. | | GO TO WWW.FLORIDABUILDING.ORG TO DOWNLOAD CORRECT SET | | OF DRAWINGS. | | IF USING THE NOA 06-0110.04, THEN ENGINEER NEEDS TO | | REVIEW AND APPROVE THIS PRODUCT APPROVAL ACCORDINGLY. | | | | 4- PROVIDE COMPLETE INFORMATION ON INSTALLATION | | SCHEDULE FOR STORM SHUTTERS. | | | | 5- ENERGY CALCULATIONS NEED TO BE SIGNED AND DATED BY | | THE OWNER/AGENT. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-12-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-12-29 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-12-29 |
Time |
16:57 |
Sent To |
PC |
|
Notes |
2008-12-30 10:02:06 | RESIDENTIAL (R3) REPAIRS, BUILDING REVIEW CHECKLIST. | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | REVISIONS. | | | | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | 13-600.0 OF FBC 2004. | | ***NOTE: MAKE SURE CORRECT 2004 REVISED FORM IS USED. | | ALSO, MAKE SURE ALL INFORMATION IS COMPLETED AND | | OWNER/AGENT SIGNS AND DATES BOTTOM OF FORM AS WELL. | | | | 2- CLEARLY IDENTIFY ON PLANS SCOPE OF WORK. CLEARLY | | IDENTIFY IF TENANT SEPARATION WALL IS GOING TO BE | | REPAIRED. IF SO, THEN PROVIDE SPECIFICATIONS FOR ONE | | HOUR FIRE RATED WALL AS REQUIRED BY SEC. R317.1 OF 2004 | | FLORIDA RESIDENTIAL CODE. | | | | 3- CLEARLY IDENTIFY WINDOWS TO BE REPLACED. SPECIFY | | TYPE OF EXISTING WINDOW (EG: SINGLE HUNG, HORIZONTAL | | SLIDER, ETC). TO VERIFY COMPLIANCE WITH THE EGRESS | | REQUIREMENTS OF SEC. R310. | | | | 4- PROVIDE COMPLETE INSTALLATION SCHEDULE FOR STORM | | SHUTTERS. SEE ATTACHED SAMPLE. ALSO, CLEARLY MARK ON | | SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS (EG: | | WALL MOUNTED, BUILD OUT, ETC) AND SPECIFIC ANCHOR TYPE | | AND SPACING TO BE USED. | | | | 5- PRODUCT APPROVAL SUBMITTED FOR ENTRY DOOR NEED TO BE | | REPLACED. ACCORDING TO MIAMI-DADE COUNTY WEBSITE NOA | | 07-0731.04 SUBMITTED IS CLOSED. SEE ATTACHED COPY FROM | | MIAMI-DADE COUNTY WEBSITE. NEED TO PROVIDE CURRENT AND | | ACTIVE PRODUCT APPROVAL. | | | | 6- ENGINEER OF RECORD NEEDS TO REVIEW AND APPROVE IN | | WRITING (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | AS REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC | | 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2009-02-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-02-04 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-02-04 |
Time |
15:50 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-08 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-08 |
Time |
08:47 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-27 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-27 |
Time |
11:07 |
Sent To |
Z |
|
Notes |
2009-01-27 11:07:28 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-12-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-12 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-12 |
Time |
16:51 |
Sent To |
M |
|
Notes |
2008-12-12 16:52:15 | TO "SFR" "M" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-12-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-12-29 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-12-05 |
Time |
10:45 |
Sent To |
|
|
Notes |
2008-12-05 10:47:58 | TO "SFR" "E" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2008-12-18 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2008-12-18 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2008-12-18 |
Time |
09:08 |
Sent To |
B |
|
Notes |
2008-12-18 09:12:20 | 12/18/08 | | INSTALLING WALL UNITS MECHANICAL PERMIT NOT REQUIRED | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-02-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-02-06 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-02-06 |
Time |
09:14 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-12-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-16 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-16 |
Time |
16:34 |
Sent To |
|
|
Notes |
2008-12-16 16:52:33 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER1 | | FBC-2004 EXISTING BUILDING | | | | 1. PLEASE INDICATE WHICH UNIT WILL BE PERMITTED FOR | | WORK ON THE APPLICATION . PLANS SHOW APT A & APT B. | | SECTION 106.1.1. | | | | 2. SHT A1 SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | FLOOR PLAN, NOR DOES IT MEET CODE REQUIREMENTS. THE | | FIXTURE DOWNSTREAM OF THE W/C IS INDICATED AS A SINK ON | | THE RISER DIAGRAM, BUT A LAV ON THE FLOOR PLAN. THE | | FIXTURE IS NOT VENTED AS SHOWN, NOR IS THE TUB. IF THE | | SANITARY PIPING IS TO BE REPLACED, THEN IT SHALL BE | | CODE COMPLIANT. SECTIONS 106.1.1 & 909.1. (SEE RED LINE | | EXAMPLE ON ONE SET OF PLANS). INDICATE PIPE SIZES. | | | | 3. PLEASE SUBMIT A CODE SUMMARY SHOWING CODE IN EFFECT, | | (FBC-2004 W/20005, 2006 & 2007 AMENDMENTS), AND | | INDICATE THE LEVEL OF ALTERATION PER CHAPTER 3 OF THE | | EXISTING BUILD CODE. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2009-02-04 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2009-02-04 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2009-02-04 |
Time |
08:43 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-12-12 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-12-12 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-12-12 |
Time |
10:20 |
Sent To |
I |
|
Notes |
2008-12-12 10:22:43 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTY?S ADDRESS AND LEGAL DESCRIPTION. | | | | 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR, | | SECTION 94-305(B)(4): WINDOW AIR-CONDITIONING UNITS MAY | | NOT PROJECT MORE THAN 18 INCHES INTO A REQUIRED SIDE | | SETBACK. | | | | 4. PROVIDE THE SCOPE OF WORK AND VALUATION FOR EACH | | BUILDING ON THE PROPERTY. NOTE: PURSUANT TO THE ZLDR, | | SECTION 94-441(C)(2): AS THE VALUE OF THE PROPOSED WORK | | MAY EXCEED 50% OF THE STRUCTURE'S VALUE (LISTED AS | | "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV. | | | | IF APPLICABLE, PLEASE SUBMIT TWO (2) COPIES OF A | | LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTIONS 94-442 | | AND 94-445 OF THE ZLDR. | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | GENERATE ADDITIONAL COMMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1444 OR (561) 805-6720 | | E-MAIL: [email protected] | | |
|
|