Plan Review Details - Permit 08120128
Plan Review Stops For Permit 08120128
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-02-19 Cont ID  
Sent By jgomez Date 2009-02-19 Time 11:17 Rev Time 0.00
Received By jgomez Date 2009-02-19 Time 11:17 Sent To  
Notes
2009-02-19 11:21:32BUILDING REVIEW APPROVED WITH PROVISO:
 1- CLARIFY WHICH SHUTTERS PRODUCT APPROVAL IS GOING TO
 BE USED. FLORIDA PRODUCT APPROVAL FL 722 OR NOA
 06-0110.04. FLORIDA PRODUCT APPROVAL FL722 IS MISSING
 THE DRAWINGS.
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 SELECTED PRODUCT APPROVAL AS REQUIRED BY SEC. 106.3.3
 CITY AMENDMENTS TO FBC 2004.
 3- A) PROVIDE COMPLETE INSTALLATION SCHEDULE FOR STORM
 SHUTTERS.
 B) CLEARLY MARK ON SHUTTERS DRAWINGS SPECIFIC MOUNTING
 CONDITIONS (EG: WALL MOUNTED, BUILT OUT, ETC) AND
 ANCHOR TYPE AND SPACING TO BE USED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-02-10 Cont ID  
Sent By jgomez Date 2009-02-10 Time 14:03 Rev Time 0.00
Received By jgomez Date 2009-02-10 Time 14:03 Sent To PC
Notes
2009-02-10 14:59:28RESIDENTIAL (R3) REPAIRS, BUILDING REVIEW SECOND
 CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 1- FLOOR PLANS SPECIFY EXISTING 33"X40" SINGLE HUNG
 WINDOWS TO REMAIN AS IS. CONTRACTOR STATES THAT WINDOWS
 ARE GOING TO BE REPLACED. REVISE PLANS AS REQUIRED.
 ***NOTE: IF WINDOWS ARE NOT TO BE REPLACED, THEN WHY
 ENGINEER IS APPROVING PRODUCT APPROVAL FOR WINDOWS AND
 SHUTTERS?.
  
 2- REVISE WIND INFORMATION ON SHEET A1:
 A) DESIGN PRESSURES FOR DOORS AND WINDOWS ARE MISSING.
 THERE IS NOT SHEET A-2.
  
 B) PROVIDE ACTUAL ROOF CLADDING CALCULATIONS. SPECIFY
 TRIBUTARY AREA AND REVISE DIMENSION FOR ROOF ZONE 2 AND
 3. SEE FOOTNOTE "A" ON FIGURE R301.2(8) OF 2004 FLORIDA
 RESIDENTIAL CODE FOR MINIMUM REQUIRED DIMENSIONS.
  
 ***NOTE: CLARIFY WHY PROVIDING ROOF CLADDING PRESSURES
 IF NOT WORK IS TO BE DONE ON THE ROOF.
  
 3- PRODUCT APPROVAL FOR SHUTTERS FL722 AND NOA
 06-0110.04 SUBMITTED DON'T CORRESPOND TO EACH OTHER. IF
 USING FL722, THEN NEED TO PROVIDE COMPLETE SET OF
 DRAWINGS THAT WERE APPROVED FOR THIS PRODUCT APPROVAL.
 GO TO WWW.FLORIDABUILDING.ORG TO DOWNLOAD CORRECT SET
 OF DRAWINGS.
 IF USING THE NOA 06-0110.04, THEN ENGINEER NEEDS TO
 REVIEW AND APPROVE THIS PRODUCT APPROVAL ACCORDINGLY.
  
 4- PROVIDE COMPLETE INFORMATION ON INSTALLATION
 SCHEDULE FOR STORM SHUTTERS.
  
 5- ENERGY CALCULATIONS NEED TO BE SIGNED AND DATED BY
 THE OWNER/AGENT.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-12-29 Cont ID  
Sent By jgomez Date 2008-12-29 Time 16:57 Rev Time 0.00
Received By jgomez Date 2008-12-29 Time 16:57 Sent To PC
Notes
2008-12-30 10:02:06RESIDENTIAL (R3) REPAIRS, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 13-600.0 OF FBC 2004.
 ***NOTE: MAKE SURE CORRECT 2004 REVISED FORM IS USED.
 ALSO, MAKE SURE ALL INFORMATION IS COMPLETED AND
 OWNER/AGENT SIGNS AND DATES BOTTOM OF FORM AS WELL.
  
 2- CLEARLY IDENTIFY ON PLANS SCOPE OF WORK. CLEARLY
 IDENTIFY IF TENANT SEPARATION WALL IS GOING TO BE
 REPAIRED. IF SO, THEN PROVIDE SPECIFICATIONS FOR ONE
 HOUR FIRE RATED WALL AS REQUIRED BY SEC. R317.1 OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 3- CLEARLY IDENTIFY WINDOWS TO BE REPLACED. SPECIFY
 TYPE OF EXISTING WINDOW (EG: SINGLE HUNG, HORIZONTAL
 SLIDER, ETC). TO VERIFY COMPLIANCE WITH THE EGRESS
 REQUIREMENTS OF SEC. R310.
  
 4- PROVIDE COMPLETE INSTALLATION SCHEDULE FOR STORM
 SHUTTERS. SEE ATTACHED SAMPLE. ALSO, CLEARLY MARK ON
 SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS (EG:
 WALL MOUNTED, BUILD OUT, ETC) AND SPECIFIC ANCHOR TYPE
 AND SPACING TO BE USED.
  
 5- PRODUCT APPROVAL SUBMITTED FOR ENTRY DOOR NEED TO BE
 REPLACED. ACCORDING TO MIAMI-DADE COUNTY WEBSITE NOA
 07-0731.04 SUBMITTED IS CLOSED. SEE ATTACHED COPY FROM
 MIAMI-DADE COUNTY WEBSITE. NEED TO PROVIDE CURRENT AND
 ACTIVE PRODUCT APPROVAL.
  
 6- ENGINEER OF RECORD NEEDS TO REVIEW AND APPROVE IN
 WRITING (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 AS REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC
 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-02-04 Cont ID  
Sent By btrobaug Date 2009-02-04 Time 15:50 Rev Time 0.00
Received By btrobaug Date 2009-02-04 Time 15:50 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-12-08 Cont ID  
Sent By btrobaug Date 2008-12-08 Time 08:53 Rev Time 0.00
Received By btrobaug Date 2008-12-08 Time 08:47 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-01-27 Cont ID  
Sent By adarroug Date 2009-01-27 Time 11:07 Rev Time 0.00
Received By adarroug Date 2009-01-27 Time 11:07 Sent To Z
Notes
2009-01-27 11:07:28TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-12 Cont ID  
Sent By adarroug Date 2008-12-12 Time 16:51 Rev Time 0.00
Received By adarroug Date 2008-12-12 Time 16:51 Sent To M
Notes
2008-12-12 16:52:15TO "SFR" "M"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-12-29 Cont ID  
Sent By jgomez Date 2008-12-29 Time 16:57 Rev Time 0.00
Received By jgomez Date 2008-12-05 Time 10:45 Sent To  
Notes
2008-12-05 10:47:58TO "SFR" "E"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-12-18 Cont ID  
Sent By hmoser Date 2008-12-18 Time 09:08 Rev Time 0.00
Received By hmoser Date 2008-12-18 Time 09:08 Sent To B
Notes
2008-12-18 09:12:2012/18/08
 INSTALLING WALL UNITS MECHANICAL PERMIT NOT REQUIRED
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-02-06 Cont ID  
Sent By kstevens Date 2009-02-06 Time 09:14 Rev Time 0.00
Received By kstevens Date 2009-02-06 Time 09:14 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-12-16 Cont ID  
Sent By kstevens Date 2008-12-16 Time 16:34 Rev Time 0.00
Received By kstevens Date 2008-12-16 Time 16:34 Sent To  
Notes
2008-12-16 16:52:33DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER1
 FBC-2004 EXISTING BUILDING
  
 1. PLEASE INDICATE WHICH UNIT WILL BE PERMITTED FOR
 WORK ON THE APPLICATION . PLANS SHOW APT A & APT B.
 SECTION 106.1.1.
  
 2. SHT A1 SANITARY RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN, NOR DOES IT MEET CODE REQUIREMENTS. THE
 FIXTURE DOWNSTREAM OF THE W/C IS INDICATED AS A SINK ON
 THE RISER DIAGRAM, BUT A LAV ON THE FLOOR PLAN. THE
 FIXTURE IS NOT VENTED AS SHOWN, NOR IS THE TUB. IF THE
 SANITARY PIPING IS TO BE REPLACED, THEN IT SHALL BE
 CODE COMPLIANT. SECTIONS 106.1.1 & 909.1. (SEE RED LINE
 EXAMPLE ON ONE SET OF PLANS). INDICATE PIPE SIZES.
  
 3. PLEASE SUBMIT A CODE SUMMARY SHOWING CODE IN EFFECT,
 (FBC-2004 W/20005, 2006 & 2007 AMENDMENTS), AND
 INDICATE THE LEVEL OF ALTERATION PER CHAPTER 3 OF THE
 EXISTING BUILD CODE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2009-02-04 Cont ID  
Sent By mcruz Date 2009-02-04 Time 13:38 Rev Time 0.00
Received By mcruz Date 2009-02-04 Time 08:43 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-12-12 Cont ID  
Sent By mcruz Date 2008-12-12 Time 10:22 Rev Time 0.00
Received By mcruz Date 2008-12-12 Time 10:20 Sent To I
Notes
2008-12-12 10:22:43PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY?S ADDRESS AND LEGAL DESCRIPTION.
  
 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR,
 SECTION 94-305(B)(4): WINDOW AIR-CONDITIONING UNITS MAY
 NOT PROJECT MORE THAN 18 INCHES INTO A REQUIRED SIDE
 SETBACK.
  
 4. PROVIDE THE SCOPE OF WORK AND VALUATION FOR EACH
 BUILDING ON THE PROPERTY. NOTE: PURSUANT TO THE ZLDR,
 SECTION 94-441(C)(2): AS THE VALUE OF THE PROPOSED WORK
 MAY EXCEED 50% OF THE STRUCTURE'S VALUE (LISTED AS
 "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV.
  
 IF APPLICABLE, PLEASE SUBMIT TWO (2) COPIES OF A
 LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTIONS 94-442
 AND 94-445 OF THE ZLDR.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved