Plan Review Stops For Permit 08120102 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2009-01-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-01-14 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-01-14 |
Time |
09:57 |
Sent To |
M |
|
Notes |
2009-01-14 10:02:03 | BUILDING PROVISO | | | | SUBMIT 2 COPIES OF THE PRODUCT APPROVALS FOR THE | | OUT-SWING IMPACT RATED GLAZED EXTERIOR ALUMINUM DOOR | | FOR APPROVAL PRIOR TO INSTALLATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-12-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-12-05 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-12-05 |
Time |
09:17 |
Sent To |
E |
|
Notes |
2008-12-05 09:17:30 | 2004 FBC W/2007 REVISIONS | | LEVEL 2 ALTERATION | | | | DENIED BY BUILDING | | | | 1) ON SHEET A.1 THE FLOOD ZONE IS INCORRECTLY SPECIFIED | | AS "C". THE CORRECT ONE IS "A5". FBC 106.1.1* CITY | | AMENDMENTS AND SEC. 94-541 CITY OF WPB MUNICIPAL CODE. | | | | 2) ON A.1 THE LEVEL OF ALTERATION IS SPECIFIED AS LEVEL | | 1 AND IT IS ACTUALLY LEVEL 2. FBC EXISTING BUILDING | | CHAPTER 3 SECTION 304. | | | | 3) ON A.1 THE ADDRESS OF THE PROJECT IN THE TITLE BLOCK | | IS INCORRECTLY SPECIFIED AS 313 GREGORY PLACE. PLEASE | | CORRECT. SEE FAC 61G-16.004 AND FBC 106.1.1* CITY | | AMENDMENTS. | | | | 4) THE S.1 SHEETS THAT WERE SUBMITTED DO NOT MATCH. | | THEY CONTAIN DIFFERENT INFORMATION. BOTH SETS OF PLANS | | ARE REQUIRED TO CONTAIN IDENTICAL INFORMATION. ONE OF | | THE SHEETS SPECIFIES A PROPOSED BARN IN WELLINGTON FOR | | THE PROJECT IDENTIFICATION IN THE TITLE BLOCK. PLEASE | | CORRECT. SEE FAC 61G-16.004 AND FBC 106.1.1* CITY | | AMENDMENTS. | | | | 5) PROVIDE A STRUCTURAL DETAIL INDICATING HOW THE | | EXTERIOR BATHROOM WINDOWS WILL BE ENCLOSED. FBC R601.2 | | | | 6) ON SHEET A1 THE SHOWER ELEVATIONS ARE LABELED DEMO | | PLAN. PLEASE CLARIFY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-01-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-01-27 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-01-27 |
Time |
07:24 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-12-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-29 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-29 |
Time |
12:21 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2008-12-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-05 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-05 |
Time |
12:43 |
Sent To |
M |
|
Notes |
2008-12-05 14:28:13 | | | | | PROVISO/REDLINED | | | | 313.1.1 NOTE. 410.4(D) SHOWER LIGHT, 680.43(A)(3) NOT | | LABELED GFI, 680.43(B)-NO HEIGHT GIVEN, MAY NEED | | GFI./WRT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-01-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-26 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-26 |
Time |
10:49 |
Sent To |
E |
|
Notes |
2009-01-26 10:49:21 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-12-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-17 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-17 |
Time |
09:47 |
Sent To |
E |
|
Notes |
2008-12-17 09:47:50 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-12-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-09 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-04 |
Time |
15:06 |
Sent To |
|
|
Notes |
2008-12-04 15:06:56 | TO "SFR" "E" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2008-12-07 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-12-07 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-12-07 |
Time |
11:03 |
Sent To |
P |
|
Notes |
2008-12-07 11:05:03 | SEPARATE MECHANICAL PERMIT REQUIRED FOR NEW BATH | | EXHAUST AND MODIFIED DRYER EXHAUST SYSTEMS. PERMIT | | APPLICATION MAY BE SUBMITTED BY MECHANICAL, A/C | | CONTRACTORS OR OWNER/BUILDER. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-01-28 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-01-28 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-01-28 |
Time |
10:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2009-01-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-01-13 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-01-13 |
Time |
14:53 |
Sent To |
M |
|
Notes |
2009-01-13 15:00:39 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | | | 1. SHT PE.1 NEW SANITARY RISER DIAGRAM DOES NOT MEET | | CODE REQUIREMENTS. THE TUB, SHOWER, AND WASH MACHINE | | SHALL BE TRAPPED. SECTION 1002.1. THE WASH MACHINE | | REQUIRES A STANDPIPE PER SECTION 1002.1 & SHALL CONFORM | | TO SECTION 802.4. THE RISER INDICATES TRAPS FOR THE LAV | | UNDERGROUND. THE TRAPS SHALL BE PLACED AS CLOSE AS | | POSSIBLE TO THE FIXTURE OUTLET AND THE VERTICLE | | DISTANCE FROM THE FIXTURE OUTLET TO THE TRAP WEIR SHALL | | NOT EXCEED 24 INCHES. SECTION 1002.1. PLEASE SEE RED | | LINE INFORMATION ON ONE SET OF PLANS AND CORRECT PLANS | | SO THEY MEET THESE CODE REQUIREMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-12-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-09 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-09 |
Time |
15:06 |
Sent To |
|
|
Notes |
2008-12-09 15:23:46 | DENIED | | REFERENCE: | | FBC-2004 RESIDENTIAL | | FBC-2004 FUEL GAS | | FBC-2004 EXISTING BUILDING | | FBC-2004 CHAPTER 1 | | | | 1. SHT A-1 ADDRESS IN THE TITLE BLOCK DOES NOT REFLECT | | THE ADDRESS ON THE APPLICATION NOR THE ADDRESS ON THE | | OTHER SHEETS. SECTION 106.1.1. | | | | 2. SHT A-1 THE LEVEL OF ALTERATION IS INCORRECT. | | SECTION 303.4. | | | | 3. SHT A-1 DETAIL FOR THE SHOWER IS TITLED "DEMOLITION" | | PLEASE CLARIFY. SECTION 106.1.1. | | | | 4. SHT A-1 DEMOLITION PLAN. IN THE REMOVAL OF ANY PART | | OF A DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | PLEASE INDICATE ON THE RISER DIAGRAM WHERE THE WASH | | MACHINE CONNECTION TO THE SANITARY IS CAPPED. OFF | | SECTION 704.5. | | | | 5. SHT PE.1 THE SANITARY RISER DIAGRAM SUBMITTED IS FOR | | THE KITCHEN AND ANOTHER SINK NOT INDICATED ON THE FLOOR | | PLAN. WORK IN THE KITCHEN AREA IS NOT INDICATED ON THE | | APPLICATION. PLEASE SUBMIT A SANITARY RISER DIAGRAM FOR | | THE BATHROOM AND THE LAUNDRY ROOM SHOWING ALL PIPE | | SIZES, TRAPS, VENTS AND CONNECTION LOCATION TO EXISTING | | BUILDING DRAIN. SECTION 106.3.5.1.3(4)(6)(13). | | | | 6. A SEPARATE GAS PERMIT IS REQUIRED FOR THE GAS WATER | | HEATER. SEE ATTACHED SHEET WITH REQUIREMENTS FOR A GAS | | PERMIT. INFORMATION REQUIRED WHEN APPLYING FOR GAS | | PERMIT. | | | | 7. SHT S.1 HAS INFORMATION THAT IS DIFFERENT FOR EACH | | SHEET SUBMITTED. PLEASE SUBMIT 2 SETS OF PLANS WITH THE | | SAME INFORMATION FOR REVIEW. SECTION 106.1. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|