Plan Review Stops For Permit 08120054 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-12-26 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-12-26 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-12-26 |
Time |
14:10 |
Sent To |
|
|
Notes |
2008-12-26 13:57:43 | PROVISOR: DOOR #302B: AN EXIT ACCESS SHALL NOT PASS | | THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. | | | | | | | | PROVISOR: DOOR #302B: AN EXIT ACCESS SHALL NOT PASS | | THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-12-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-12-08 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-12-08 |
Time |
14:04 |
Sent To |
|
|
Notes |
2008-12-08 14:04:30 | BUILDING PLAN REVIEW | | PERMIT: 08120054 | | ADD: 444 WEST RAILROAD AVE. #300 | | CONT: PBM DEVELOPMENT INC. | | TEL: (561)368-2544 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 12-8-08 | | REVIEW: 1ST | | ACTION: DENIED | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION | | SHALL BE SHOWN ON THE PLANS. | | | | 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | THIS CODE. INDICATE THE LEVEL OF ALTERATION ON THE | | PLANS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-09-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-09-02 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-09-02 |
Time |
16:41 |
Sent To |
PC |
|
Notes |
2009-09-02 16:43:16 | | | | | REVISION #3, SHEETS E2.1, E3.1, E5.1./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-12-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-30 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-30 |
Time |
14:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-12-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-09 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-09 |
Time |
08:40 |
Sent To |
|
|
Notes |
2008-12-09 13:26:45 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} PER 13-415.2.ABC.1.1. PAGE #2 OF THE ENERGY GAUGE | | INPUT DATA REPORT, DOES NOT INDICATE THE CORRECT NUMBER | | OF FIXTURES AS SHOWN ON THE PLAN, | | | | 2} THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING | | OR A SEPARATELY METERED OR PERMITTED PORTION OF A | | BUILDING SHALL BE DETERMINED BY EITHER THE BUILDING | | AREA METHOD DESCRIBED IN SECTION 415.2.C.1 OR THE | | SPACE-BY-SPACE METHOD DESCRIBED IN SECTION 415.2.B.1. | | THE INSTALLED INTERIOR LIGHTING POWER IDENTIFIED IN | | ACCORDANCE WITH SECTION 415.2.ABC.1.1 SHALL NOT EXCEED | | THE INTERIOR LIGHTING POWER ALLOWANCE DEVELOPED IN | | ACCORDANCE WITH SECTION 415.2.C.1 OR 415.2.B.1. THIS | | CAN BE DEMONSTRATED ON THE PLANS INDICATING THE | | WATTAGES OF THE LUMINAIRES CHOSEN FOR THE PROJECT | | CONFORM TO THE DENSITY REQUIREMENTS. INDICATE WATTAGES | | ON THE FIXTURE SCHEDULE TO CORRELATE WITH THE ONES IN | | THE CALCULATIONS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2009-01-06 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2009-01-06 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2009-01-06 |
Time |
10:22 |
Sent To |
|
|
Notes |
2009-01-06 10:23:53 | ***PROVISO*** | | | | PER DISCUSSION WITH ARCHITECT OF RECORD, DOORS LEADING | | TO STAIRWELLS ARE (1) HOUR FIRE RATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2008-12-11 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-12-11 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-12-11 |
Time |
14:55 |
Sent To |
|
|
Notes |
2008-12-11 15:10:30 | PLANS APPEAR TO BE CODE COMPLIANT. PLEASE SEE THE | | FOLLOWING FOR CLARIFICATION: | | | | 1) DOOR SCHEDULE INDICATES (2) 1 HOUR RATED DOORS AND | | DRAWINGS SHOW (2) 45 MINUTE DOORS. PLEASE CORRELATE | | INFORMATION. | | | | 2) IF APPLICABLE, DUCT SMOKE DETECTORS SHALL INITIATE A | | GENERAL FIRE ALARM IN ACCORDANCE WITH LOCAL | | REQUIREMENTS. SEE SHEET FA0.1 | | | | | | PLANS WILL BE STAMPED WHEN RETURNED WITH THIS AND OTHER | | REVIEW COMMENT CORRECTIONS. | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-10-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-10-05 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-10-05 |
Time |
10:52 |
Sent To |
M |
|
Notes |
2009-10-05 10:56:01 | TO RR'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-12-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-22 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-22 |
Time |
16:51 |
Sent To |
|
|
Notes |
2008-12-22 16:53:56 | TO "BOB"#8 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-12-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-15 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-03 |
Time |
09:06 |
Sent To |
|
|
Notes |
2008-12-03 09:10:39 | TO "BOB"#5 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2009-10-07 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-10-07 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-10-07 |
Time |
12:05 |
Sent To |
|
|
Notes |
2009-10-07 12:05:56 | REVISED M2.1 AND M4.1 DELTA 4 - PROVISOS ADDRESSED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2008-12-14 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-12-14 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-12-14 |
Time |
11:52 |
Sent To |
|
|
Notes |
2008-12-14 11:57:33 | REVIEW #: 1ST | | ACTION: PASS W/ PROVISO | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | THE FOLLOWING RED-LINE NOTES HAVE BEEN PLACED ON PLANS. | | PLEASE MAKE CORRECTION, REVISE AND RESUBMIT CORRECTED | | PLANS FOR REVISION. | | | | **PROVISO** | | PAGE M2.1: THERE ARE TWO VAV BOXES LABELED AS | | "VAV-3-32" AND THERE IS NO VAV 3-21 SHOWN ON FLOOR | | PLAN. PLEASE CORRECT AND REVISE. FBCM 603.1 AND FBCB | | 106.1.1. | | | | **PROVISO** | | PAGE M6.1: FLEX DUCT DETAIL CALLS FOR MIN. 1" WIDE | | STRAP FOR FLEX DUCT SUPPORT. THE SUPPORT SHALL BE MIN. | | 1 1/2" WIDE IN ACCORDANCE WITH FBCM 603.5.6.6. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2008-12-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-15 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-15 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-12-10 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2008-12-10 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2008-12-10 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|