Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-12-10 Cont ID  
Sent By jgomez Date 2008-12-10 Time 16:37 Rev Time 0.00
Received By jgomez Date 2008-12-10 Time 15:22 Sent To PC
Notes
2008-12-10 16:57:20RESIDENTIAL (R3) ROOF FRAMING, BUILDING REVIEW
 CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
 NOTE: THIS MAY BE SUBMITTED AT TIME OF PERMIT PICK UP.
  
 2- SHEET 2:
 A) PROVIDE CONNECTION DETAIL AT POINT WHERE THE TWO HIP
 RAFTERS MEET THE ROOF GIRDER. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH THE
 DESIGN LOADS OF SEC. R301 OF 2004 FLORIDA RESIDENTIAL
 CODE. THERE IS NOT DETAIL OR SPECS PROVIDED FOR THIS
 CONNECTION.
  
 B) CLARIFY IF ROOF IS GOING TO BE ATTACHED TO EXISTING
 HOUSE OR NOT. PROVIDE DETAIL AS REQUIRED. SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH
 THE DESIGN LOADS OF SEC. R301 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 C) CLARIFY IF HIP ROOF RAFTER IS A 2X MEMBER OR 4X
 MEMBER. CONNECTOR "B" SPECIFIED ON CONNECTOR SCHEDULE
 IS HCP4Z, WHICH IS FOR A 4X WOOD MEMBER. ROOF FRAMING
 PLAN SHOWS A 2X WOOD MEMBER. REVISE/CLARIFY AS
 REQUIRED.
  
 D) SPECIFY CONNECTION OF ROOF RAFTERS TO HIP RAFTER.
 THERE IS NOT CONNECTOR SPECIFIED ON ROOF FRAMING PLAN.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004 TO VERIFY
 COMPLIANCE WITH SEC. R301 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 3- SHEET 3:
 A) REVISE ROOF SHEATHING NAILING SCHEDULE TABLE AND
 PLYWOOD NAILING SKETCH. NAIL TYPE TO BE 8D RING SHANK
 NAILS (NOT PLAIN 8D) FOR ALL ROOF ZONES. ALSO, ROOF
 ZONE 3 NEEDS TO HAVE NAIL SPACING AT 4"O.C. AT EDGES
 AND INTERMEDIATE SUPPORTS AS REQUIRED BY SEC.
 R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE. REVISE AS
 REQUIRED.
 ALSO, REMOVE NOTE STATING THAT RING SHANK NAILS ARE NOT
 REQUIRED WHEN MEAN ROOF HEIGHT <25'.
  
 B) WIND ZONES SKETCH SHOWING THE HIP ROOF ON ONE SIDE
 AND GABLE END ON THE OTHER SIDE IS MISSING ROOF ZONES 2
 AND 3 ON HIP SIDE. REVISE AS REQUIRED. SEE FIGURE
 R301.2(8) OF 2004 FLORIDA RESIDENTIAL CODE.
  
 C) TYPICAL WALL SECTION SHOWS 1X6 FASCIA BOARD, WHILE
 PLYWOOD NAILING DETAIL SHOWS 2X6 WOOD FASCIA. REVISE AS
 REQUIRED TO MATCH.
  
 4- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR ALL SIMPSON STRUCTURAL CONNECTORS
 SPECIFIED ON PLANS AND DETAILS.
 NOTE: PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND PAGE WHERE CONNECTOR IS SHOWN. NO NEED TO
 SUBMIT COMPLETE REPORT. THIS APPLIES TO STRUCTURAL
 CONNECTORS ONLY.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-07-30 Cont ID  
Sent By jwitmer Date 2009-07-30 Time 09:28 Rev Time 0.00
Received By jwitmer Date 2009-07-30 Time 09:28 Sent To  
Notes
2009-07-30 09:30:54NICOMING: R-6

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-09 Cont ID  
Sent By adarroug Date 2008-12-09 Time 15:06 Rev Time 0.00
Received By adarroug Date 2008-12-09 Time 15:06 Sent To B
Notes
2008-12-09 15:06:19TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-12-10 Cont ID  
Sent By jgomez Date 2008-12-10 Time 16:57 Rev Time 0.00
Received By jgomez Date 2008-11-26 Time 16:00 Sent To  
Notes
2008-11-26 16:00:22TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2009-08-05 Cont ID  
Sent By mcruz Date 2009-08-05 Time 13:57 Rev Time 0.00
Received By mcruz Date 2009-08-05 Time 13:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-12-08 Cont ID  
Sent By mcruz Date 2008-12-08 Time 16:36 Rev Time 0.00
Received By mcruz Date 2008-12-08 Time 16:16 Sent To I
Notes
2008-12-08 16:31:43PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. WHAT WILL THIS STRUCTURE BE UTILIZED FOR? DWELLING
 UNIT OR AN ACCESSORY STRUCTURE? NOTE: A DWELLING IS NOT
 PERMITTED.
  
 PURSUANT TO SECTION 94-304(B)(3) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), ACCESSORY STRUCTURES
 SHALL BE LOCATED NO CLOSER THAN SIX (6) FEET TO THE
 PRINCIPAL STRUCTURE.
  
 THE SURVEY INDICATES THE EXISTING SEPERATION DISTANCE
 IS 4.8 FEET. A VARIANCE FROM THE ZONING BOARD OF
 APPEALS (ZBA) SHALL BE REQUIRED IF YOU WISH TO MAINTAIN
 THE ACCESSORY STRUCTURE AT THAT DISTANCE. CONTACT THE
 PLANNING AND ZONING DEPARTMENT IF YOU HAVE ANY
 QUESTIONS REGARDING THE ZBA PROCESS.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved