Plan Review Details - Permit 08110518
Plan Review Stops For Permit 08110518
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-03-13 Cont ID  
Sent By jwitmer Date 2009-03-13 Time 12:06 Rev Time 1.22
Received By jwitmer Date 2009-03-13 Time 12:06 Sent To  
Notes
2009-03-13 12:14:05BUILDING PLAN REVIEW
 PERMIT: 08110518
 ADD: 2400 N FLAGLER
 CONT: PLAN REVIEW
 TEL: (561)248-5574/ CARL SHEPARD
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 3RD REVIEW
 MARCH 13/09
 ACTION:REVIEWED
  
 NOTE: BOAT ADA TRANSFER LIFT REQUIRED BY DEPARTMENT OF
 JUSTICE FOR TRANSPORTATION SYSTEMS: TITLE II PUBLIC
 FACILITY. NOT ENFOREABLE BY THIS AGENCY.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-03-09 Cont ID  
Sent By jwitmer Date 2009-03-09 Time 13:48 Rev Time 2.22
Received By jwitmer Date 2009-03-09 Time 13:48 Sent To  
Notes
2009-03-09 15:19:31BUILDING PLAN REVIEW
 PERMIT: 08110518
 ADD: 2400 N FLAGLER
 CONT: PLAN REVIEW
 TEL: (561)248-5574/ CARL SHEPARD
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 MARCH 09/09
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 2) COMPLIED.
  
 3) COMPLIED.
  
 4) COMPLIED.
  
 5) BOAT ADA LIFT REMOVED FROM SHEET 1 THROUGH 7. ADA
 TRANSFER OR BOAT LIFT, PLEASE PROVIDE INFORMATION
 .TITLE III OF THE ADA PUBLIC TRANSPORTATION SYSTEMS AND
 TITLE II PUBLIC FACILITY.
  
 6) SEMI-COMPLIED. PLANS NOW SHOW A GUARD RAIL ON THE
 SIDES OF THE FLOATING DOCK WHERE BOATS ARE NOT LOADING.
 THE PROBLEM IS THE 1012.3 OPENING LIMITATIONS, THE
 GUARD IS TO BE ABLE TO REJECT A 4" SPHERE, THE PLANS
 FOR BOTH THE FLOATING DOCK AND GANGWAY DO NOT INDICATE
 THIS.
  
 7) 2ND REQUEST, SHEET 6 INDICATES THE USE OF HURRICANE
 STRAPS OR TIES, RULE 9-B REQUIRES PRODUCT APPROVALS FOR
 SUCH ITEMS, RULE 9-B(31)(G).
 106.3 PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO
 COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE
 APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL,
 SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR
 SITE SPECIFIC FORM PER RULE 9B-72.
  
 8) NOT TO BE ENFORCED BY RULE OF NEW B.O.
  
 9) ELECTRICAL SHEET# 4 INDICATES THE USE OF LIGHT POLES
 BUT AGAIN THERE IS NO DESIGN CRITERIA FOR WIND,
 1603.1.4.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-12-10 Cont ID  
Sent By jwitmer Date 2008-12-10 Time 09:27 Rev Time 2.22
Received By jwitmer Date 2008-12-10 Time 09:27 Sent To  
Notes
2008-12-10 11:21:08BUILDING PLAN REVIEW
 PERMIT: 08110518
 ADD: 2400 N FLAGLER
 CONT: PLAN REVIEW
 TEL: (561)248-5574/ CARL SHEPARD
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 2) CITY CODE OF ORDINANCES REQUIRES: SEC. 94-378.
 SHORELINE MANAGEMENT.
 (A) DOCKS, MARINAS, ETC.
 (1) NEW BOAT BASINS, MARINAS, DOCKS AND OTHER MOORING
 FACILITIES ARE PROHIBITED UNLESS APPROVED BY THE
 APPROPRIATE GOVERNMENTAL AGENCIES, SUCH AS THE U.S.
 ARMY CORP OF ENGINEERS, STATE DEPARTMENT OF
 ENVIRONMENTAL REGULATION, STATE DEPARTMENT OF NATURAL
 RESOURCES, BOARD OF TRUSTEES OF THE INTERNAL
 IMPROVEMENT TRUST FUND, AND THE SOUTH FLORIDA WATER
 MANAGEMENT DISTRICT.
 (2) IN NO EVENT SHALL ANY NEW BOAT BASIN, MARINA,
 DOCKS, OR ANY OTHER STRUCTURE BE APPROVED WHICH WOULD
 CONSTRICT WATER CIRCULATION IN LAKE WORTH.
  
 3) PLANS DO NOT INDICATE WIND DESIGN CRITERIA: 1603.1.4
 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDINGS AND STRUCTURES:
  
 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR
 TABLE 6-1, ASCE 7 AND BUILDING CLASSIFICATION IN TABLE
 1-1, ASCE 7.
  
 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE
 AND APPLICABLE WIND DIRECTION SHALL BE INDICATED.
  
 4) PLEASE SHOW ACCESSIBLE ROUTE TO DOCK PLANS INDICATE
 STAIRS ALONG THE BULKHEAD IT APPEARS THERE IS NO
 RAMPAGE.11-4.3.2 (2) AT LEAST ONE ACCESSIBLE ROUTE
 SHALL CONNECT ACCESSIBLE BUILDINGS, ELEMENTS, AND
 SPACES THAT ARE ON THE SAME SITE.
  
 5) SHEET 1 AND 4 THE PLANS APPEAR TO HAVE A ADA
 TRANSFER OR BOAT LIFT, PLEASE PROVIDE INFORMATION
 .TITLE III OF THE ADA PUBLIC TRANSPORTATION SYSTEMS AND
 TITLE II PUBLIC FACILITY.
  
 6) PLANS FAIL TO SHOW GUARDS ON THE FLOATING DOCK WHERE
 THERE IS TO BE NO LOADING INTO BOATS PLEASE REVIEW
 1012.1. SECTION 1618.4.2 CAN NOT BE USED SINCE THIS IS
 FOR THE HIGH-VELOCITY HURRICANE ZONES- SPECIAL LOAD
 CONSIDERATIONS.
  
 7) SHEET 6 INDICATES THE USE OF HURRICANE STRAPS OR
 TIES, RULE 9-B REQUIRES PRODUCT APPROVALS FOR SUCH
 ITEMS, RULE 9-B(31)(G).
 106.3 PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO
 COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE
 APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL,
 SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR
 SITE SPECIFIC FORM PER RULE 9B-72.
  
 8) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 9) SHEET 9 INDICATES THE USE OF LIGHT POLES BUT AGAIN
 THERE IS NO DESIGN CRITERIA FOR WIND,
 1603.1.4.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-03-13 Cont ID  
Sent By btrobaug Date 2009-03-03 Time 14:50 Rev Time 0.00
Received By btrobaug Date 2009-03-03 Time 14:33 Sent To B
Notes
2009-03-13 10:49:25FOR CONDUIT AND WIRE ONLY, POLE TYPE AND WIND
 CALCULATION WILL BE SUBMITTED AT A LATER DATE./WRT.
2009-03-12 09:30:22 
  
  
2009-03-03 14:50:12 
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-12-09 Cont ID  
Sent By btrobaug Date 2008-12-09 Time 15:42 Rev Time 0.00
Received By btrobaug Date 2008-12-09 Time 13:35 Sent To  
Notes
2008-12-09 15:33:58 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} INCLUDE THE ADDRESS OF THE PROJECT ON THE PLANS PER
 106.1.1 FBC AS AMENDED.
  
 2} 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE
 PERMITTED TO BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL (SEE ALSO SECTION
 106.3.5).THERE IS NOT ENOUGH INFORMATION ON THE PLAN TO
 REVIEW ELECTRICAL EQUIPMENT, SYSTEM, INSTALLATION ETC.
 ALSO SEE ARTICLE 555 NEC, 2005, NFPA-303-2000 CHAPTER
 3.
  
 3} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471
 FS, RESPECTIVELY.
 THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL
 IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES,
 IF EXEMPTIONS APPLY.SEE PAGES 8 & 9.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2009-03-04 Cont ID  
Sent By mgonzale Date 2009-03-04 Time 14:04 Rev Time 1.00
Received By mgonzale Date 2009-03-04 Time 14:01 Sent To  
Notes
2009-03-04 14:04:31**** APPROVED *****
  
 PLANS DATED 02-09-09
 SOME DETAIL CALL-OUTS HAVE BEEN MARKED-UP FOR
 CLARIFICATION.
  
 ALL AS-BUILTS, INCLUDING ELECTRICAL MUST BE SUBMITTED
 IN CAD AND IN PDF FORMAT.
  
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2008-12-26 Cont ID  
Sent By mgonzale Date 2008-12-26 Time 12:53 Rev Time 1.00
Received By mgonzale Date 2008-12-26 Time 12:46 Sent To ENG
Notes
2008-12-26 12:53:02***** FAILED ******
  
 PLANS FAILED, LOTS OF COMMENTS. PLEASE SEE PLANS.
 SECTION VIEWS ARE CALLED OUT INCORRECTLY
 QUETIONS ON REQUIRED PERMITTING BY DEP AND OR ARMY CORE
 OF ENGINEERING.
 PLAN REQUIRES EXTRA DIMENSIONING TO PROPERLY CONTROL
 THE PLACEMENT OF PILES
 NORTH ARROW MISSING
 LOCATION MAP NEEDS MORE DETAIL.
 HARDWARE SHOULD BE STAINLESS.
 REMOVAL OF EXISTING PILES SHOULD FALL UNDER
 CONSTRUCTION PLANS.
 IS THE BOAT DOCK AVAILABLE TO ANY BOAT OR JUST WATER
 TAXI, MORE SPECIFIC SIGNS MAY NEED TO BE IN PLACE TO
 ADVISE BOATERS.
 PLEASE SEE PLANS FOR REDLINES.
  
 MANUEL J GONZALEZ, PROJECT COORDINATOR
 LOCATION ADDRESS:
 CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 1000 - 45TH STREET, SUITE 15
 WEST PALM BEACH FL 33407
 MAILING ADDRESS:
 CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 P.O. BOX 3506
 WEST PALM BEACH FL 33401
 TELEPHONE:
 45TH STREET OFFICE : 561-494-1040
 45TH DIRECT: 561-494-1085
 FAX: 561-494-1117
 CITY HALL OFFICE: (561) 805-6723
 CITY HALL DIRECT: (561) 805-6327
 CITY HALL FAX: (561) 805-6731 OR 805-6676
 NEXTEL: 561-644-7301
 NEXTEL DIRECT CONNECT: 159*28165*38
 EMERGENCIES:
 CENTRAL OPERATIONS CENTER (DISPATCH) 561-822-2210
 E-MAIL:
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2009-03-12 Cont ID  
Sent By mwennerg Date 2009-03-12 Time 15:50 Rev Time 0.00
Received By mwennerg Date 2009-03-12 Time 15:50 Sent To  
Notes
2009-03-12 15:52:17***PROVISO***
  
 1) SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED FOR FIRE
 STANDPIPE SYSTEM.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2009-03-04 Cont ID  
Sent By mwennerg Date 2009-03-04 Time 10:32 Rev Time 0.00
Received By mwennerg Date 2009-03-04 Time 10:32 Sent To  
Notes
2009-03-04 10:37:42***DENIED***
  
 1) OK
  
 2) OK
  
 3) THE PLANS ILLUSTRATE THE DISTANCE FROM THE CLOSEST
 FIRE HYDRANT. THE PREVIOUS COMMENT REQUESTED THE HOSE
 LAY DIATNCE FROM A FIRE APPARATUS. PLEASE NOTE THAT IF
 THE DISTANCE EXCEEDS 150' A CLASS I STANDPIPE SYSTEM IS
 REQUIRED IN ACCORDANCE WITH NFPA 303, SEC. 4.4.1. IF
 THIS PROJECT REQUIRES A STANDPIPE SYSTEM, PROVIDE THE
 FIRE PROTECTION DRAWINGS AND DETAILS.
  
 4) OK
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-12-11 Cont ID  
Sent By mwennerg Date 2008-12-11 Time 12:42 Rev Time 0.00
Received By mwennerg Date 2008-12-11 Time 12:42 Sent To  
Notes
2008-12-11 12:46:46***DENIED***
  
 1) WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 303,
 STANDARD FOR MARINAS AND BOATYARDS.
  
 2) PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED.
  
 3) PROVIDE APPROXIMATE HOSE LAY DISTANCE FROM FIRE
 APPARATUS TO DETERMINE NEED FOR CLASS I STANDPIPE
 SYSTEM.
  
 4) WILL FUELING OPERATIONS BE CONDUCTED OR ANTICIPATED?
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-03-13 Cont ID  
Sent By jwitmer Date 2009-03-13 Time 10:21 Rev Time 0.00
Received By jwitmer Date 2009-03-13 Time 10:21 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-02-27 Cont ID  
Sent By adarroug Date 2009-02-18 Time 10:54 Rev Time 0.00
Received By adarroug Date 2009-02-18 Time 10:55 Sent To  
Notes
2009-03-03 09:14:51CORRECTION: TO "COMM" BD #25 **EXPEDITED**
2009-02-27 10:55:31TO "COMM" BD#18--EXPEDITED--

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-12-26 Time   Rev Time 0.00
Received By adarroug Date 2008-11-26 Time 09:56 Sent To  
Notes
2008-11-26 10:08:04TO "COMM" BD#44--EXPEDITED--

Review Stop Z ZONING
Rev No 2 Status P Date 2009-02-26 Cont ID  
Sent By kdfreema Date 2009-02-26 Time 11:39 Rev Time 0.00
Received By kdfreema Date 2009-02-26 Time 11:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-12-04 Cont ID  
Sent By kdfreema Date 2008-12-04 Time 16:09 Rev Time 0.00
Received By kdfreema Date 2008-12-04 Time 16:09 Sent To  
Notes
2008-12-04 16:11:17PLANS ARE ZONING-COMPLIANT.
  
 ONCE AN OFFICIAL PERMIT SUBMITTAL IS MADE, PLANS WILL
 BE STAMPED AND THE FAILED STATUS WILL BE CHANGED TO
 PASS.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER AT X1458 WITH
 QUESTIONS.