Plan Review Stops For Permit 08110405 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2010-10-28 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-10-28 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-10-28 |
Time |
11:17 |
Sent To |
|
|
Notes |
2010-10-28 11:22:12 | BUILDING PROVISO | | | | | | UPDATED ENERGY CALCULATIONS ARE REQUIRED TO BE | | SUBMITTED ON THE 2007 FORMS. | | | | | | | | LUIS MARTINEZ | | CHIEF PLANS EXAMINER | | 561-805-6710 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2010-03-17 |
|
|
Cont ID |
|
Sent By |
pyusko |
Date |
2010-03-17 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
pyusko |
Date |
2010-03-17 |
Time |
14:27 |
Sent To |
|
|
Notes |
2010-03-17 14:44:08 | BUILDING REVIEW COMMENTS: | | | | 1. ENERGY CALCS ARE REQUIRED | | 2. HISTORICAL APPROVAL IS REQUIRED | | 3. SEPARATE PERMITS FOR FENCE AND WALL | | | | LUIS MARTINEZ, 805-6710 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-28 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-28 |
Time |
08:27 |
Sent To |
|
|
Notes |
2009-05-28 08:29:53 | BUILDING REVIEW CHECKLIST. | | | | 1- PLANS SUBMITTED NEED TO BE COORDINATED. SHEET 6.1 | | SUBMITTED IS THE OLD SHEET THAT WAS DENIED THE FIRST | | TIME PLANS WERE REVIEWED. PROVIDE REVISED SHEET 6.1. | | | | 2- FLAT ROOF PRODUCT APPROVAL SUBMITTED: SPECIFY WHICH | | APPROVED ASSEMBLY AND BASE SHEET FASTENING OPTION IS | | GOING TO BE USED. PROVIDE RAS 117 CALCULATIONS FOR NAIL | | ENHANCING AT PERIMETER AND CORNER AREAS AS REQUIRED BY | | GENERAL LIMITATION #7. PRODUCT APPROVAL NOA SUBMITTED | | WAS SUPERSEDED BY DADE COUNTY. SEE ATTACHED COPY FROM | | DADE COUNTY WEBSITE. NEED TO PROVIDE CURRENT NOA. | | | | 3- PROVIDE INFORMATION REQUESTED ON PROVISO DATED | | 5/6/09. SEE ATTACHED COPY. NEED GUARDRAILS COMPLETE | | DETAILS/SPECS. PRODUCT APPROVAL FL4334-R3 SUBMITTED IS | | FOR 2007 CODE VERSION. PLANS WERE REVIEW UNDER 2004 | | CODE VERSION. ALSO, NEED TO PROVIDE PRODUCT APPROVAL | | FOR ALL DOORS AS SHOWN ON PLANS. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
N |
Date |
2009-05-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-05-06 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-05-06 |
Time |
10:07 |
Sent To |
|
|
Notes |
2009-05-06 13:15:28 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | BALCONY GUARDRAIL TO SHOW COMPLIANCE WITH TABLE R301.5 | | AND SEC. R312 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 2- PROVIDE 2 COPIES OF PRODUCT APPROVALS FOR EXTERIOR | | SWING DOORS AS SHOWN ON PLANS. DCA RULE 9B-72. | | ***NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE THEM | | PRIOR TO SUBMITTAL. SEC. 106.3.3 CITY AMENDMENTS TO FBC | | 2004. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-03-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-03-03 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-03-03 |
Time |
17:02 |
Sent To |
PC |
|
Notes |
2009-03-03 17:06:43 | RESIDENTIAL (R3) ADDITION/ALTERATION/RENOVATION | | BUILDING REVIEW SECOND CHECKLIST. | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | REVISIONS. | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. | | ***NOTE: THIS DOCUMENT MAY BE RECORDED LATER AT TIME OF | | PERMIT PICK UP. | | | | 2- SHEET 1.1: | | A) CLARIFY SCOPE OF WORK. PERMIT APPLICATION DESCRIBES | | REMODELING THE INTERIOR AND EXTERIOR ACCORDING TO | | PLANS. PERMIT APPLICATION DOESN'T INCLUDE THE ADDITION | | OF THE NEW BALCONY. ALSO, IS NOT CLEAR IF AREA OF WORK | | IS THE REAR ACCESSORY BUILDING ONLY. OR IF EXISTING | | MAIN HOUSE IS GOING TO HAVE SOME WORK ALSO. THERE IS | | ONLY ONE NOTE ON MAIN HOUSE SAYING THAT EXISTING | | RESIDENCE TO BE REMODELED, BUT THE DRAWINGS DON'T SHOW | | ANY WORK FOR THE MAIN HOUSE. FENCES AND PRIVACY WALL | | ARE TO BE DONE UNDER SEPARATE PERMITS. CLARIFY NOTES | | REGARDING GRADING SLOPE. IS REGRADING PART OF THE SCOPE | | OF WORK IN THIS PERMIT? | | ***COMMENTS TO INFORMATION SUBMITTED: | | (A) STILL NO CLEAR. PLANS SAY "NEW COVERED ENTRY AT | | EXISTING ENTRY" AND "NEW ADDITION" ON REAR OF HOUSE BUT | | THERE IS NOT INFORMATION PROVIDED ON PLANS. PROVIDE | | ONLY THE INFORMATION FOR SCOPE OF WORK TO BE PERFORMED | | AND PROVIDE INFORMATION ON SEPARATE PERMITS WHEN | | SEPARATE PERMITS ARE REQUIRED. | | | | 3- SHEET 2.1: CLARIFY SCOPE OF WORK FOR GUEST HOUSE | | NOTE: EXPAND BUILDING +/- 1'-6" TO ACCOMMODATE STAIRS | | TO MEET CURRENT CODE. THERE IS NOT INFORMATION PROVIDED | | TO SHOW COMPLIANCE WITH THIS NOTE. AND, PLANS DON'T | | SHOW ANY BUILDING EXPANSION. ON THE OTHER HAND CHECK | | ZONING COMMENTS REGARDING BUILDING EXPANSION. | | ***OK. | | | | 4- SHEET 3.1: | | A) SPECIFY SAFETY GLASS FOR WINDOWS ON BATHROOMS AS | | REQUIRED BY SEC. R308.4 OF 2004 FLORIDA RESIDENTIAL | | CODE. | | ***COMMENTS TO INFORMATION SUBMITTED: | | (A) PLANS SUBMITTED SPECIFY ""ALL BATH WINDOWS TO BE | | GLAZED FOR PRIVACY". PRIVACY AND SAFETY GLASS ARE TWO | | DIFFERENT THINGS. SEE SEC. R308.4 AND REVISE AS | | REQUIRED. | | | | B) CLARIFY SCOPE OF WORK FOR GUEST HOUSE REGARDING THE | | EXPANSION OF BUILDING +/- 1'-6" TO ACCOMMODATE STAIRS. | | THERE IS NOT INFORMATION ON PLANS REGARDING THIS ISSUE. | | ***OK. | | | | C) CLARIFY FLOOR FRAMING NOTE. THERE IS NOT SECTION #1 | | ON SHEET 6.1. ALSO, CLARIFY SCOPE OF WORK TO BE | | PERFORMED. COORDINATE WITH ITEM 2A ABOVE. | | ***OK. | | | | D) NEW BALCONY FRAMING PLAN: | | *SPECIFY ALL BEAMS. CLARIFY WHY SHOWING ONLY ONE MEMBER | | TO RECEIVE ALL FLOOR JOISTS?. | | ***OK. | | | | **CLARIFY IF USING 2X6 FLOOR JOISTS OR 2X8 FLOOR | | JOISTS. BOTH ARE MENTIONED ON PLAN. SEE COMMENTS ON | | REVIEWED SET OF PLANS. | | NOTE: COORDINATE SIZE OF JOIST HANGER ACCORDINGLY. | | ***OK. | | | | ***CLARIFY ATTACHMENT OF WOOD POST TO BEAM. PROVIDE | | DETAIL. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004 TO | | VERIFY COMPLIANCE WITH THE CALCULATED LOADS OF SEC. | | R301 OF 2004 FLORIDA RESIDENTIAL CODE. WHY IS THERE A | | LEDGER SHOWN INSTEAD OF A BEAM TO POST CONNECTION?. | | CLEARLY SPECIFY CONNECTIONS AT CORNER POSTS AND | | INTERMEDIATE POSTS. | | ***OK. | | | | ****SPECIFY HOW MANY SCREWS ARE REQUIRED TO ATTACH 2X6 | | WOOD DECK. TO VERIFY COMPLIANCE WITH UPLIFT LOADS OF | | SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE. | | ***OK. | | | | *****CLARIFY WHY DIMENSIONS SHOW 6" WHEN SHOWING THE | | WOOD POST IF THE POSTS ARE SPECIFIED AS 4X4 POSTS? SEE | | COMMENTS ON PLANS. | | ***OK. | | | | | | E) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | GUARDRAIL TO SHOW COMPLIANCE WITH TABLE R301.5, AND | | SECTION R312 OF 2004 FLORIDA RESIDENTIAL CODE. | | ***COMMENTS TO INFORMATION SUBMITTED: | | (A) DETAIL SUBMITTED ON SHEET 5.1 DOESN'T PROVIDE ANY | | FASTENING SPECIFICATIONS. ALSO, THERE IS A NOTE SAYING | | THAT "WOOD HANDRAIL AND GUARDRAIL TO BE DESIGNED IN | | ACCORDANCE TO 2004 FBC". DESIGNER OF RECORD NEEDS TO | | PROVIDE THE DESIGN INFORMATION, NOT JUST CITE THE CODE | | IN GENERAL. | | | | 5- SHEET 4.1: | | A) INFORMATION SHOWN ON EXISTING ROOF PLAN DOESN'T | | MATCH INFORMATION SHOWN ON CONNECTOR SCHEDULE. CLARIFY | | SCOPE OF WORK. COORDINATE WITH ITEM 2A ABOVE. | | ***OK. | | | | B) REVISE NOTES AT BOTTOM OF CONNECTOR SCHEDULE. SEE | | COMMENTS ON PLANS. SEE SEC. R803.2.3.1 OF 2004 FLORIDA | | RESIDENTIAL CODE FOR MINIMUM NAIL SIZE/TYPE AND SPACING | | INCLUDING ON ROOF ZONE #3. | | ***OK. | | | | C) COMPONENTS AND CLADDING PRESSURES ZONES TABLES FOR | | ROOF AND WALLS IS MISSING THE NAILING SPACING AT | | INTERMEDIATE SUPPORTS. IT ONLY CALLS FOR NAILING AT | | EDGES. SEE COMMENTS ON PLANS. | | ***COMMENTS TO INFORMATION SUBMITTED: | | (A) NEED TO REVISE SPACING AT INTERMEDIATE SUPPORTS. | | SEE SEC. R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE | | AND REVISE AS REQUIRED. | | | | D) CLARIFY WHY THE NAILING SPACING SHOWN ON WALLS | | COMPONENTS AND CLADDING TABLE IS CLOSER TOGETHER FOR | | WALL ZONE 4 THAN FOR WALL ZONE 5. | | ***COMMENTS TO INFORMATION SUBMITTED: | | (A) NO DONE. WHY ZONE 4 IS STRONGER THAN ZONE 5? | | | | 6- SHEET 5.1: | | A) TYPICAL TWO STORY WALL SECTION: | | *CLEARLY SPECIFY WHAT'S NEW AND WHAT'S EXISTING. | | COORDINATE WITH ITEM 2A ABOVE. | | ***COMMENTS TO INFORMATION SUBMITTED: | | (A) STILL NO CLEAR WHAT'S NEW AND WHAT'S EXISTING. | | INFORMATION PROVIDED IS VERY CONFUSING. EG: IS THERE A | | NEW T&G SOFFIT?. HOW IS THE INSTALLATION OF NEW H10 | | SIMPSON CONNECTORS DONE?. IS THERE A NEW GYPSUM BOARD | | CEILING ON INSIDE?. IS THER A NEW WALL SHEATHING | | OUTSIDE?. INFORMATION PROVIDED IS NOT CLEAR. | | | | **SPECIFY ALL CONNECTORS FROM ROOF TO FOOTING TO SHOW | | CONTINUOUS LOAD PATH AS REQUIRED BY SEC. R601.2 OF 2004 | | FLORIDA RESIDENTIAL CODE. | | NOTE: CLARIFY WHY ONLY SECOND FLOOR JOISTS ARE RESTING | | ON ONLY ONE TOP PLATE IF THIS IS A BEARING WALL?. | | ***RESPONSE TO INFORMATION SUBMITTED: | | (A) ARE CONNECTORS NEW OR THEY ARE EXISTING?. | | | | ***SOFFIT AREA SPECIFIES 3"X16" VENTS AT 72"O.C.. | | PROVIDE CALCULATIONS TO SHOW THAT THESE VENTS ARE | | ADEQUATE TO COMPLY WITH SEC. R806 OF 2004 FLORIDA | | RESIDENTIAL CODE. | | SEE COMMENTS ON PLANS. | | ***OK. | | | | B) DOOR AND WINDOWS JAMB DETAILS DON'T MATCH WITH | | TYPICAL WINDOW OPENING SECTION AND TYPICAL WALL FRAMING | | SECTION. REVISE AS REQUIRED TO MATCH. SEE COMMENTS ON | | PLANS AND RETURN REVIEWED SET AFTER PLANS ARE REVISED. | | ***OK. | | | | *** C) NEW COMMENTS TO NEW TYPICAL STAIR DETAIL | | SUBMITTED: | | (A) CLARIFY IF RE-DOING EXISTING STAIRS. RISER TO TREAD | | RATION SHOWN ON THIS DETAIL DOESN'T COMPLY WITH SEC. | | R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE. ALSO, WHY | | SHOWING A GUARDRAIL ON STAIRWAY. GUARDRAIL NOT | | REQUIRED. ONLY HANDRAIL IS REQUIRED. SPECIFICATIONS | | CALL FOR 2 LAYERS OF TYPE X GYPSUM BD. ONLY ONE LAYER | | WAS SHOWN. SEE COMMENTS ON PLANS. | | | | 7- BRING REVISED PLANS FOR HISTORIC REVIEW STAMP (5TH | | FLOOR) PRIOR TO SUBMITTAL TO THIS OFFICE. | | ***NEED TO BRING ANY PLANS THAT ARE REVISED AFTER | | TODAY'S COMMENTS. | | | | 8- OWES $1.70 FOR NEW BALCONY RADON FEES AS REQUIRED BY | | CHAPTER 10D-91 FLORIDA ADMINISTRATIVE CODE., SUBPART B. | | ***OK. | | | | 9- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | A) ALL NEW EXTERIOR DOORS. CLEARLY IDENTIFY ENTRY DOORS | | AND BALCONY DOORS. | | *** INFORMATION NOT PROVIDED. | | | | 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | *** THIS APPLIES TO PRODUCT APPROVALS NOT SUBMITTED AT | | THIS TIME. | | | | 11- NEW COMMENT: | | (A) CLARIFY WHY SUBMITTING SEPARATE WIND LOAD | | CALCULATIONS. | | (B) SEPARATE WIND LOAD CALCULATIONS DON'T MATCH THOSE | | SHOWN ON SHEET 4.1. REVISE AS REQUIRED. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2009-01-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-01-14 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-01-14 |
Time |
12:33 |
Sent To |
PC |
|
Notes |
2009-01-14 13:26:24 | RESIDENTIAL (R3) ADDITION/ALTERATION/RENOVATION | | BUILDING REVIEW CHECKLIST. | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | REVISIONS. | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. | | ***NOTE: THIS DOCUMENT MAY BE RECORDED LATER AT TIME OF | | PERMIT PICK UP. | | | | 2- SHEET 1.1: | | A) CLARIFY SCOPE OF WORK. PERMIT APPLICATION DESCRIBES | | REMODELING THE INTERIOR AND EXTERIOR ACCORDING TO | | PLANS. PERMIT APPLICATION DOESN'T INCLUDE THE ADDITION | | OF THE NEW BALCONY. ALSO, IS NOT CLEAR IF AREA OF WORK | | IS THE REAR ACCESSORY BUILDING ONLY. OR IF EXISTING | | MAIN HOUSE IS GOING TO HAVE SOME WORK ALSO. THERE IS | | ONLY ONE NOTE ON MAIN HOUSE SAYING THAT EXISTING | | RESIDENCE TO BE REMODELED, BUT THE DRAWINGS DON'T SHOW | | ANY WORK FOR THE MAIN HOUSE. FENCES AND PRIVACY WALL | | ARE TO BE DONE UNDER SEPARATE PERMITS. CLARIFY NOTES | | REGARDING GRADING SLOPE. IS REGRADING PART OF THE SCOPE | | OF WORK IN THIS PERMIT? | | | | ***NOTE: SEE COMMENTS ON REVIEWED SET OF PLANS AND | | RETURN REVIEWED SET AFTER COMMENTS ARE ADDRESSED ON | | ORIGINAL PLANS TO EXPEDITE THE REVIEW PROCESS. | | | | 3- SHEET 2.1: CLARIFY SCOPE OF WORK FOR GUEST HOUSE | | NOTE: EXPAND BUILDING +/- 1'-6" TO ACCOMMODATE STAIRS | | TO MEET CURRENT CODE. THERE IS NOT INFORMATION PROVIDED | | TO SHOW COMPLIANCE WITH THIS NOTE. AND, PLANS DON'T | | SHOW ANY BUILDING EXPANSION. ON THE OTHER HAND CHECK | | ZONING COMMENTS REGARDING BUILDING EXPANSION. | | | | 4- SHEET 3.1: | | A) SPECIFY SAFETY GLASS FOR WINDOWS ON BATHROOMS AS | | REQUIRED BY SEC. R308.4 OF 2004 FLORIDA RESIDENTIAL | | CODE. | | | | B) CLARIFY SCOPE OF WORK FOR GUEST HOUSE REGARDING THE | | EXPANSION OF BUILDING +/- 1'-6" TO ACCOMMODATE STAIRS. | | THERE IS NOT INFORMATION ON PLANS REGARDING THIS ISSUE. | | | | C) CLARIFY FLOOR FRAMING NOTE. THERE IS NOT SECTION #1 | | ON SHEET 6.1. ALSO, CLARIFY SCOPE OF WORK TO BE | | PERFORMED. COORDINATE WITH ITEM 2A ABOVE. | | | | D) NEW BALCONY FRAMING PLAN: | | *SPECIFY ALL BEAMS. CLARIFY WHY SHOWING ONLY ONE MEMBER | | TO RECEIVE ALL FLOOR JOISTS?. | | | | **CLARIFY IF USING 2X6 FLOOR JOISTS OR 2X8 FLOOR | | JOISTS. BOTH ARE MENTIONED ON PLAN. SEE COMMENTS ON | | REVIEWED SET OF PLANS. | | NOTE: COORDINATE SIZE OF JOIST HANGER ACCORDINGLY. | | | | ***CLARIFY ATTACHMENT OF WOOD POST TO BEAM. PROVIDE | | DETAIL. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004 TO | | VERIFY COMPLIANCE WITH THE CALCULATED LOADS OF SEC. | | R301 OF 2004 FLORIDA RESIDENTIAL CODE. WHY IS THERE A | | LEDGER SHOWN INSTEAD OF A BEAM TO POST CONNECTION?. | | CLEARLY SPECIFY CONNECTIONS AT CORNER POSTS AND | | INTERMEDIATE POSTS. | | | | ****SPECIFY HOW MANY SCREWS ARE REQUIRED TO ATTACH 2X6 | | WOOD DECK. TO VERIFY COMPLIANCE WITH UPLIFT LOADS OF | | SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | *****CLARIFY WHY DIMENSIONS SHOW 6" WHEN SHOWING THE | | WOOD POST IF THE POSTS ARE SPECIFIED AS 4X4 POSTS? SEE | | COMMENTS ON PLANS. | | | | | | E) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR | | GUARDRAIL TO SHOW COMPLIANCE WITH TABLE R301.5, AND | | SECTION R312 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 5- SHEET 4.1: | | A) INFORMATION SHOWN ON EXISTING ROOF PLAN DOESN'T | | MATCH INFORMATION SHOWN ON CONNECTOR SCHEDULE. CLARIFY | | SCOPE OF WORK. COORDINATE WITH ITEM 2A ABOVE. | | | | B) REVISE NOTES AT BOTTOM OF CONNECTOR SCHEDULE. SEE | | COMMENTS ON PLANS. SEE SEC. R803.2.3.1 OF 2004 FLORIDA | | RESIDENTIAL CODE FOR MINIMUM NAIL SIZE/TYPE AND SPACING | | INCLUDING ON ROOF ZONE #3. | | | | C) COMPONENTS AND CLADDING PRESSURES ZONES TABLES FOR | | ROOF AND WALLS IS MISSING THE NAILING SPACING AT | | INTERMEDIATE SUPPORTS. IT ONLY CALLS FOR NAILING AT | | EDGES. SEE COMMENTS ON PLANS. | | | | D) CLARIFY WHY THE NAILING SPACING SHOWN ON WALLS | | COMPONENTS AND CLADDING TABLE IS CLOSER TOGETHER FOR | | WALL ZONE 4 THAN FOR WALL ZONE 5. | | | | 6- SHEET 5.1: | | A) TYPICAL TWO STORY WALL SECTION: | | *CLEARLY SPECIFY WHAT'S NEW AND WHAT'S EXISTING. | | COORDINATE WITH ITEM 2A ABOVE. | | | | **SPECIFY ALL CONNECTORS FROM ROOF TO FOOTING TO SHOW | | CONTINUOUS LOAD PATH AS REQUIRED BY SEC. R601.2 OF 2004 | | FLORIDA RESIDENTIAL CODE. | | NOTE: CLARIFY WHY ONLY SECOND FLOOR JOISTS ARE RESTING | | ON ONLY ONE TOP PLATE IF THIS IS A BEARING WALL?. | | | | ***SOFFIT AREA SPECIFIES 3"X16" VENTS AT 72"O.C.. | | PROVIDE CALCULATIONS TO SHOW THAT THESE VENTS ARE | | ADEQUATE TO COMPLY WITH SEC. R806 OF 2004 FLORIDA | | RESIDENTIAL CODE. | | SEE COMMENTS ON PLANS. | | | | B) DOOR AND WINDOWS JAMB DETAILS DON'T MATCH WITH | | TYPICAL WINDOW OPENING SECTION AND TYPICAL WALL FRAMING | | SECTION. REVISE AS REQUIRED TO MATCH. SEE COMMENTS ON | | PLANS AND RETURN REVIEWED SET AFTER PLANS ARE REVISED. | | | | 7- BRING REVISED PLANS FOR HISTORIC REVIEW STAMP (5TH | | FLOOR) PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | 8- OWES $1.70 FOR NEW BALCONY RADON FEES AS REQUIRED BY | | CHAPTER 10D-91 FLORIDA ADMINISTRATIVE CODE., SUBPART B. | | | | 9- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | A) METAL ROOF AS SHOWN ON PLANS. | | | | B) ALL NEW EXTERIOR DOORS. CLEARLY IDENTIFY ENTRY DOORS | | AND BALCONY DOORS. | | | | C) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | D) STORM SHUTTERS IF WINDOWS AND DOORS WITH GLAZING | | DON'T HAVE IMPACT GLAZING. | | ***NOTE: PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE | | ATTACHED COPY. AND, CLEARLY MARK ON SHUTTERS DRAWINGS | | SPECIFIC MOUNTING CONDITIONS (EG: WALL MOUNTED, BUILD | | OUT, ETC) AND SPECIFIC ANCHOR TYPE AND SPACING TO BE | | USED TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF | | SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2010-05-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-05-18 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-05-18 |
Time |
16:15 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2010-05-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-05-03 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-05-03 |
Time |
12:16 |
Sent To |
|
|
Notes |
2010-05-03 12:25:43 | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2008 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS | | AMENDED.PLANS INDICATING THE SCOPE OF WORK MUST BE | | SUBMITTED WITH THE APPLICATION. 106.1 FBC AS AMENDED. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2010-03-17 |
|
|
Cont ID |
|
Sent By |
pyusko |
Date |
2010-03-17 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
pyusko |
Date |
2010-03-17 |
Time |
15:01 |
Sent To |
|
|
Notes |
2010-03-17 15:33:00 | ELECTRICAL REVIEW COMMENTS: | | | | 1. NOTE: REVIEW WAS DONE UNDER THE 2008 NEC. IF UNDER | | THE 2005 NEC PLEASE DISREGARD AREA COMMENTS NOTED WITH | | 2008 NEC. | | | | 2. NOTE: THERE IS CONFUSION OVER THE SERVICE AS SHOWN. | | THE ELECTRICAL RISER STATES *EXISTING ELECTRICAL RISER | | DIAGRAM*. HOWEVER, THERE ARE SEVERAL ITEMS WHICH ARE | | ALSO SHOWN AS NEW. REVIEW IS BASED ON THESE ITEMS AS | | NEW AND NOT EXISTING. THERE IS INFORMATION NOT YET | | SHOWN TO CONFIRM A COMPLETE REVIEW. | | A) PLEASE SEE 250.94 FOR REQUIRED INTERSYSTEM BOND. | | 2008 NEC. | | B) PLEASE INDICATE THE SIZE OF THE EXISTING SERVICE TO | | INCLUDE SERVICE ENTRANCE CONDUCTORS. 240.4, 31.16, | | 310.15 ETC. | | C) PLEASE COORDINATE PANELS AND RISER. PANELS ARE SHOWN | | RATED AT 150AMPS, YET THE RISER INDICATES PANELS AS | | 100AMPS. | | D) PLEASE SEE RISER AS BOTH DISCONNECTS SHOWN FOR BOTH | | UPSTAIRS AND DOWNSTAIRS PANELS ARE RATED AT 200AMPS. IT | | IS NOT PERMITTED TO HAVE 200AMP RATED OVER CURRENT | | PROTECTION FEEDING 100AMP OR 150AMP RATED PANELS. | | E) THE SAME 200AMP RATED DISCONNECTS ARE SHOWN ON | | FEEDERS RATED FOR 100AMPS. THIS IS NOT PERMITTED. | | PLEASE VERIFY MAINS AND OVERCURRENT PROTECTION. 310.16, | | 240.4, 310.15B6 | | | | 3. NOTE: PLEASE SEE 210.12 OF THE 2008 NEC AND LIST ALL | | REQUIRED ARC FAULT PROTECTED CIRCUITS. PLEASE SEE SAME | | CODE SECTION UNDER THE 2005 NEC AND LIST ACCORDINGLY. | | | | 4. NOTE: PLEASE SEE 406.8 FOR REQUIRED RECEPTACLES | | OUTSIDE IN DAMP OR WET LOCATIONS. 2008 NEC | | | | 5. NOTE: PLEASE SEE 250.32, 250.66, 250.50 FOR | | GROUNDING ELECTRODE SYSTEM REQUIRED AT DETACHED | | BUILDING. | | | | 6. NOTE: PLEASE SEE 250.66 FOR SIZING OF THE GROUNDING | | ELECTRODE CONDUCTOR AT SERVICE. AS THE SERVICE ENTRANCE | | CONDUCTORS AND THE SIZE OF SERVICE ARE NOT SHOWN, THE | | #4 AS SHOWN CANNOT BE CONFIRMED TO BE CODE COMPLIANT. | | BASED ON THE LOAD AND SIZE OF ALL OVER CURRENT | | PROTECTIVE DEVICES SHOWN, THE GROUNDING ELECTRODE IS | | TOO SMALL. | | | | 7. NOTE: CLOSET LIGHT FIXTURES SHOWN DO NOT APPEAR TO | | MEET 410.8 | | | | 8. NOTE: PLANS DO NOT CONTAIN ANY DESIGN PROFESSIONAL | | MEETING 481, 471, 489 OR 481.229, 471.003 EXCEPTIONS | | PLEASE BE SURE PLANS CONTAIN RESPONSIBLE DESIGNER UNDER | | SECTIONS NOTED. | | | | 9. NOTE: ALL RECEPTACLES SERVING KITCHEN COUNTER SPACE | | ARE REQUIRED TO BE GFI/GFI PROTECTED. 210.8A6 | | | | 10. NOTE: OVER CURRENT PROTECTION FOR 5KW AHU IS TOO | | HIGH. 422.11 | | | | 11. NOTE: LIGHTING FIXTURE REQUIRED IN KITCHEN AND ALSO | | SHOWS LIGHT SWITCH NOT CONTROLLING ANYTHING? 210.70 | | NEW OR EXISTING LIGHT FIXTURES IN STAIRS? | | NEW OR EXISTING LIGHT IN SECOND FLOOR BATH? | | | | 12. NOTE: MISSING SMOKE ALARM PER 11.5.1, 11.8.3 OF | | NFPA-72 ON LOWER LEVEL OF STAIRS LEADING TO FLOOR | | ABOVE. | | | | 13. NOTE: PANEL SCHEDULES NEED TO BE SPECIFIC. FIRST | | FLOOR ONLY INDICATES ONE CIRCUIT FOR GENERAL LIGHTING. | | WHERE ARE THE OTHER GENERAL LIGHTING AND RECEPTACLE | | CIRCUITS? THESE ARE ALSO REQUIRED TO BE SPECIFIC TO | | ROOMS AND AREAS IN WHICH THEY FEED. THE USE OF GENERAL | | LIGHTING AND RECEPTACLES IS NO LONGER ACCEPTACLE UNDER | | THE 2005 AND 2008 NEC. 408.4 | | | | 14. NOTE: NO ELECTRICAL SHOWN ON PLANS FOR SECOND FLOOR | | WASHER/DRYER? FBC 106.3.5.1.2, 210.52F, 210.11C2 | | | | 15. NOTE: DISCONNECTS FOR PANELS AT DETACHED STRUCTURE | | ARE SHOWN ON PLANS, HOWEVER NOT ON RISER. 225.31-225.39 | | | | | | DEWEY PALMER | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-15 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-15 |
Time |
12:31 |
Sent To |
B |
|
Notes |
2009-05-15 13:54:51 | | | | | TO JULIO'S DESK, NEEDS STATUS ENTERED./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-02-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-02-18 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-02-18 |
Time |
12:12 |
Sent To |
P |
|
Notes |
2009-02-18 12:51:58 | | | APPLICATION #08110405 ELECTRICAL PLAN REVIEW | | 716 NEW YORK STREET 1/8/09 | | WEST PALM BEACH, FL. | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, 2004 FBC AS AMENDED, CHAPTER 1, AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | ALL COMMENTS RELATE TO SHEET 7.1, UNLESS OTHERWISE | | NOTED | | | | THESE COMMENTS FROM THE PREVIOUS REVIEW NEED FURTHER | | RESPONCE, INDICATED BY *** | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471 | | FS, RESPECTIVELY*** NOT DONE AND NO RESPONSE GIVEN. | | | | 3} PROVIDE A SITE PLAN INDICATING THE LOCATION OF ALL | | SERVICE EQUIPMENT SO THAT COMPLIANCE WITH ARTICLES 230 | | AND 225 CAN BE REVIEWED*** THE SITE PLAN SHOWS THERE | | ARE NO DISCONNECTS ON THE BACK BUILDING PER | | 230.70(A)(1) "READILY ACCESSIBLE LOCATION THE SERVICE | | DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY | | ACCESSIBLE LOCATION EITHER OUTSIDE OF A BUILDING OR | | STRUCTURE OR INSIDE NEAREST THE POINT OF ENTRANCE OF | | THE SERVICE CONDUCTORS". ALSO SEE 250.32 FOR GROUNDING | | OF SEPARATE STRUCTURES. INCLUDE ON THE RISER. | | | | 7 } PROVIDE CONDUIT AND CONDUCTOR SIZE AND TYPE FOR THE | | FEEDERS ON THE RISER DIAGRAM.***THIS COMMENT MUST BE | | RESPONDED TOO SO THE COMPLIANCE FOR 250.122, | | 310.15(B)(6) CAN BE REVIEWED. THE RESPONSE OF THE | | SERVICE BEING INSTALLED UNDER ANOTHER PERMIT IS ONLY | | PARTIALLY CORRECT AS THAT PERMIT (#06120063) EXPIRED | | WITHOUT HAVING PASSED ANY INSPECTIONS. THE CONDUCTORS | | AND CONDUIT SIZE AND TYPE NEED TO BE VERIFIED AS | | COMPLIANT. INDICATE ON DRAWINGS. | | | | PLEASE REMOVE OLD SHEETS, INSERT NEW ONES, SUBMIT OLD | | SHEETS (ONE SET) TO EXPEDITE REVIEW AND SUBMIT WRITTEN | | RESPONSE TO THE COMMENTS MADE IN THIS REVIEW. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2009-01-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-01-08 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-01-08 |
Time |
14:34 |
Sent To |
P |
|
Notes |
2009-01-08 16:31:35 | | | | | APPLICATION #08110405 ELECTRICAL PLAN REVIEW | | 716 NEW YORK STREET 1/8/09 | | WEST PALM BEACH, FL. | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, 2004 FBC AS AMENDED, CHAPTER 1, AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | ALL COMMENTS RELATE TO SHEET 7.1, UNLESS OTHERWISE | | NOTED | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471 | | FS, RESPECTIVELY. | | | | 2} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT | | CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE | | EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS | | EQUAL TO OR GREATER THAN THE AVAILABLE FAULT. | | | | 3} PROVIDE A SITE PLAN INDICATING THE LOCATION OF ALL | | SERVICE EQUIPMENT SO THAT COMPLIANCE WITH ARTICLES 230 | | AND 225 CAN BE REVIEWED. | | | | 4} PROVIDE LOAD CALCULATIONS FOR THE SERVICE SHOWN | | (INCLUDING THE MAIN HOUSE) PER ARTICLE 220 PART III, | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. | | | | 5} THERE ARE TWO RECTANGULAR BOXES IN THE FEED FROM THE | | PANEL TO THE 100 AMP PANELS IN THE BACK BUILDING. | | INDICATE IF THESE ARE EQUIPMENT, AND IF SO WHAT. ADD TO | | ELECTRICAL SYMBOLS LEGEND ALONG WITH AN EXPLANATORY | | NOTE. 215.5 NEC | | | | 6} LOCATE ALL PANELS AND DISCONNECTS ON THE FLOOR PLAN | | FOR THE UNITS, THIS SHEET. 215.5 NEC. | | | | 7 } PROVIDE CONDUIT AND CONDUCTOR SIZE AND TYPE FOR THE | | FEEDERS ON THE RISER DIAGRAM. | | | | 8} THE A/C IS LISTED AS 5 KW IN THE LOAD CALCULATIONS | | BUT SHOWN AS 10 KW IN THE PANEL SCHEDULES, BOTH FLOORS. | | THERE ARE NO MANUFACTURES SPECIFICATIONS FOR THE AIR | | HANDLERS ON SHEET 6.1, PROVIDE SAME SO THE CORRECT | | CALCULATIONS AND PANEL SCHEDULE OCP AND CONDUCTOR SIZES | | MAY BE REVIEWED. 220, 240 NEC. SEE NOTE 16 THIS SHEET. | | | | 9} THE BATH CIRCUITS REQUIRED BY 210.11(C)(3) ARE NOT | | LISTED ON THE PANEL SCHEDULE. | | | | 10} THERE ARE DISHWASHERS ON THE PANEL SCHEDULES (BOTH) | | THAT ARE NOT SHOWN IN THE UNITS OR LISTED IN THE | | CALCULATIONS. 408.4 NEC. | | | | 11} THERE ARE NO SMOKE ALARMS IN THE FIRST FLOOR UNIT. | | 313.1.1 | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2008-11-19 |
|
|
Cont ID |
|
Sent By |
ssherman |
Date |
2008-11-19 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
ssherman |
Date |
2008-11-19 |
Time |
11:43 |
Sent To |
|
|
Notes |
2008-11-19 11:44:02 | HISTORICAL APPROVAL PER JILLIAN PAPA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2010-04-30 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-04-29 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-04-29 |
Time |
12:22 |
Sent To |
|
|
Notes |
2010-04-30 12:23:39 | GAVE TO BILL, PLANS ARE BEING HAND CARRIED |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-05-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-21 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-21 |
Time |
11:52 |
Sent To |
|
|
Notes |
2009-05-21 11:54:30 | TO R15 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-29 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-29 |
Time |
10:29 |
Sent To |
|
|
Notes |
2009-04-29 10:29:28 | TO R-20 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-02-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-10 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-10 |
Time |
09:37 |
Sent To |
Z |
|
Notes |
2009-02-10 09:37:26 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-12-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-12 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-12 |
Time |
10:34 |
Sent To |
E |
|
Notes |
2008-12-12 10:35:15 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2009-01-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-01-14 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-11-21 |
Time |
08:31 |
Sent To |
|
|
Notes |
2008-11-21 08:31:58 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2010-05-18 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-05-18 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-05-18 |
Time |
14:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2010-03-17 |
|
|
Cont ID |
|
Sent By |
pyusko |
Date |
2010-03-17 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
pyusko |
Date |
2010-03-17 |
Time |
14:44 |
Sent To |
|
|
Notes |
2010-03-17 14:49:50 | MECHANICAL REVIEW COMMENTS: | | | | M1401.3 - HEATING AND COOLING LOAD CALCULATIONS | | | | N1108.0.8 - ALL REPLACED OR RETROFITTED SYSTEMS AND | | COMPONENTS SHALL MEET PRESCRIPTION REQUIREMENTS | | CONTAINED IN METHOD B | | | | LUIS MARTINEZ, 805-6710 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2009-01-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2009-01-13 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2009-01-13 |
Time |
09:46 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2010-05-18 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-05-18 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-05-18 |
Time |
10:53 |
Sent To |
M |
|
Notes |
2010-05-18 10:57:28 | PLUMBING PERMIT REQUIRED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2010-03-17 |
|
|
Cont ID |
|
Sent By |
pyusko |
Date |
2010-03-17 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
pyusko |
Date |
2010-03-17 |
Time |
14:50 |
Sent To |
|
|
Notes |
2010-03-17 15:00:44 | PLUMBING REVIEW COMMENTS: | | | | 1. P3005.6 - PROVIDE CLEANOUT AT BASE OF VERTICAL WASTE | | STACK | | | | 2. P2706.2 - STANDPIPE FOR WASHING MACHINE SHALL EXTEND | | A MINIMUM OF 18" AND A MAXIMUM OF 42" | | | | LUIS MARTINEZ, 805-6710 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2009-06-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-06-15 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-06-15 |
Time |
14:06 |
Sent To |
|
|
Notes |
2009-06-15 14:14:35 | DENIED | | REFERENCE: | | FBC-2004 W/2007 REVISIONS | | FBC-2004 RESIDENTIAL | | FBC-2004 CHAPTER 1 | | | | 1. SHT 6.1 (7 OF 9) NOW SUBMITTED HAS A SANITARY RISER | | DIAGRAM THAT DOES NOT REFLECT THE FLOOR PLAN, NOR DOES | | IT MEET CODE REQUIREMENTS. AN APPROVED SANITARY RISER | | DIAGRAM IS STILL SHOWN ON SHT 5.1 (5 OF 8). PLEASE | | CLARIFY AND CORRELATE PLANS. SHT C.1 INDICATES 9 | | SHEETS, BUT MANY SHEETS ARE INDICATED AS SHEETS # 2, 3, | | 4, 5, 6 & 8 OF 8. SECTIONS 106.1 & 106.1.1. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2009-05-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-05 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-05 |
Time |
10:45 |
Sent To |
|
|
Notes |
2009-05-05 10:48:51 | PLANS ARE CODE COMPLIANT FOR THE FBC-2004 PLUMBING, BUT | | SHEET C.1 ON BOTH SETS OF PLANS SUBMITTED FOR PUBLIC | | RECORD ARE PHOTO COPIES AND ARE NOT SEALED. WHEN THE | | SHEETS ARE LEGALLY SIGNED, SEALED & DATED PER FAC | | 61G1-15 & FS 481.2055 THEN THE PLUMBING STATUS WILL BE | | CHANGED TO PASSED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2009-02-27 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-02-27 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-02-27 |
Time |
14:02 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-12-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-16 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-16 |
Time |
14:13 |
Sent To |
E |
|
Notes |
2008-12-16 14:36:02 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 EXISTING BUILDING | | FBC-2004 RESIDENTIAL | | FBC-2004 CHAPTER 1 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. SHT 3.1 SCOPE OF WORK AND APPLICATION DOES NOT | | INDICATE PLUMBING WORK. PLANS SHOW EXISTING BATHROOMS, | | KITCHENS BUT NOT WASH MACHINES. SUBMITTED ON SHT 5.1 IS | | A SANITARY RISER DIAGRAM. PLEASE CLARIFY. WILL THERE BE | | PLUMBING WORK FOR THIS PERMIT? WILL THERE BE NEW | | FIXTURES, NEW SHOWER PANS, ETC.? SECTION 106.1.1. | | INDICATE THE EXTENT OF PLUMBING WORK IF ANY. | | | | 2. ALL SHEETS. THE ADDRESS IN THE TITLE BLOCK OF THE | | ARCHITECT OF RECORD DOES NOT RELECT THE ADDRESS ON THE | | STATE OF FLORIDA DBPR WEBSITE, (2669 FOREST HILL BLVD). | | PLEASE UPDATE THE TITLE BLOCKS ON THE PLANS OR THE | | STATE OF FLORIDA DBPR WEBSITE PRIOR TO RESUBMITTING | | PLANS FOR REVIEW. FAC G1G1-16.004(1) & FS 481.2055. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2010-05-11 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2010-05-11 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2010-05-11 |
Time |
16:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2009-06-03 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-06-03 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-06-03 |
Time |
08:58 |
Sent To |
|
|
Notes |
2009-06-03 09:00:42 | ZONING PLAN REVIEW | | | | PERMIT NO.: 08110405 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: PERUSA CONSULTANT & INVESTMENT | | TELEPHONE NO.: 772.528.9436 | | SCOPE OF REVIEW: REMODEL OF INTERIOR/EXTERIOR OF | | ACCESSORY STRUCTURE | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) THE FOLLOWING COMMENT IS A REPEAT COMMENT THAT WAS | | GENERATED DUE TO REVISIONS THAT WERE MADE ON THE LAST | | SUBMITTAL: | | | | 1A) THE MECHANICAL (A/C) EQUIPMENT SHOW FOR THE | | ACCESSORY STRUCTURE DOES NOT MEET SETBACK REQUIREMENTS. | | PURSUANT TO SECTION 94-305 OF THE CITY'S ZONING AND | | LAND DEVELOPMENT REGULATIONS, MECHANICAL EQUIPMENT | | SHALL ENCROACH NO MORE THAN FOUR (5) FEET INTO A | | REQUIRED SETBACK. AS THE REQUIRED SETBACK IS 12 FEET | | FOR THE SUBJECT PROPERTY, MECHANICAL EQUIPMENT SHALL BE | | LOCATED NO CLOSER THAN EIGHT (8) FEET TO THE REAR | | PROPERTY LINE. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1459 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2009-05-08 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-05-08 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-05-08 |
Time |
11:45 |
Sent To |
|
|
Notes |
2009-05-08 11:49:29 | ZONING PLAN REVIEW | | | | PERMIT NO.: 08110405 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: PERUSA CONSULTANT & INVESTMENT | | TELEPHONE NO.: 772.528.9436 | | SCOPE OF REVIEW: | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) THE FOLLOWING COMMENT HAS BEEN GENERATED DUE TO | | REVISIONS THAT WERE MADE SINCE THE LAST SUBMITTAL: | | | | 1A) THE MECHANICAL (A/C) EQUIPMENT SHOW FOR THE | | ACCESSORY STRUCTURE DOES NOT MEET SETBACK REQUIREMENTS. | | PURSUANT TO SECTION 94-305 OF THE CITY'S ZONING AND | | LAND DEVELOPMENT REGULATIONS, MECHANICAL EQUIPMENT | | SHALL ENCROACH NO MORE THAN FOUR (5) FEET INTO A | | REQUIRED SETBACK. AS THE REQUIRED SETBACK IS 12 FEET | | FOR THE SUBJECT PROPERTY, MECHANICAL EQUIPMENT SHALL BE | | LOCATED NO CLOSER THAN EIGHT (8) FEET TO THE REAR | | PROPERTY LINE. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1459 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2009-02-17 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2009-02-17 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2009-02-17 |
Time |
09:33 |
Sent To |
|
|
Notes |
2009-02-17 09:36:37 | ZONING PLAN REVIEW | | | | PERMIT NO.: 08110405 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: FERUSA CONSULTANT & INVESTMENT | | TELEPHONE NO.: (772) 528-9436 | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) THE FOLLOWING COMMENTS FROM PREVIOUS REVIEWS HAVE | | NOT BE ADDRESSED: | | | | 1A) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY SHALL | | BE PROVIDED. | | | | 1B) THE VALUE OF THE PROPOSED WORK ($35,000) IN | | ADDITION TO THE VALUE OF WORK ALREADY COMPLETED | | ($26,313.31 ACCORDING TO DOCUMATION PROVIDED BY THE | | PROPERTY OWNER), EXCEEDS 50% OF THE VALUE OF THE | | STRUCTURE ($100,677.51 ACCORDING TO AN APPRAISAL | | PROVIDED BY THE PROPERTY OWNER). PURSUANT TO SECTION | | 94-513(B)(1)(D) OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS, NONCONFORMING USES WITH NO | | ADVERSE IMPACTS MAY ONLY BE REPAIRED OR ALTERED SO LONG | | AS THE COSTS INCURRED DO NOT EXCEED 50% OF THE ACCESSED | | VALUE OF THE STRUCTURE WITHIN ANY 12-MONTH PERIOD. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-12-11 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2008-12-11 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2008-12-11 |
Time |
17:43 |
Sent To |
|
|
Notes |
2008-12-11 17:55:41 | ZONING PLAN REVIEW | | | | PERMIT NO.: 08110405 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: FERUSA CONSULTANT & INVESTMENT | | TELEPHONE NO.: (772) 871-0175 | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) TWO (2) COPIES OF A CURRENT/ACCURATE SURVEY SHALL BE | | PROVIDED. | | | | 2) PURSUANT TO THE FINAL ORDER ISSUED IN ZBA CASE NO. | | 3232, THE FOLLOWING ITEMS HAVE NOT BEEN ADDRESSED: | | | | 2A) A SIX (6) FOOT FENCE SHALL BE PROVIDED ALONG THE | | EAST PROPERTY LINE, IMMEDIATELY ADJACENT TO THE | | ACCESSORY STRUCTURE. | | | | 2B) LANDSCAPING SHALL BE INSTALLED TO SCREEN THE DECK | | FROM THE IMMEDIATE ADJOINING NEIGHBOR. | | | | 2C) SHIELDING SHALL BE PROVIDED OF ANY LIGHT UPON THE | | IMMEDIATE ADJOINGING NEIGHBOR. | | | | 3) THE SCOPE OF WORK NOTED ON THE PLANS CONTINUE TO | | PROVIDE AN EXPANSION OF ONE (1) FOOT SIX (6) INCHES TO | | ACCOMMODATE THE STAIRS. PURSUANT TO THE FINAL ORDER IN | | ZBA CASE NO. 3232, THE ACCESSORY STRUCTURE MAY NOT BE | | ENLARGED IN ANY MANNER. | | | | 4) THE VALUE OF THE PROPOSED WORK ($35,000) IN ADDITION | | TO THE VALUE OF WORK ALREADY COMPLETED ($26,313.31 | | ACCORDING TO DOCUMATION PROVIDED BY THE PROPERTY | | OWNER), EXCEEDS 50% OF THE VALUE OF THE STRUCTURE | | ($100,677.51 ACCORDING TO AN APPRAISAL PROVIDED BY THE | | PROPERTY OWNER). PURSUANT TO SECTION 94-513(B)(1)(D) OF | | THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS, | | NONCONFORMING USES WITH NO ADVERSE IMPACTS MAY ONLY BE | | REPAIRED OR ALTERED SO LONG AS THE COSTS INCURRED DO | | NOT EXCEED 50% OF THE ACCESSED VALUE OF THE STRUCTURE | | WITHIN ANY 12-MONTH PERIOD. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. | | |
|
|