Plan Review Details - Permit 08100683
Plan Review Stops For Permit 08100683
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-11 Cont ID  
Sent By mjacobs Date 2008-12-11 Time 15:21 Rev Time 0.00
Received By mjacobs Date 2008-12-11 Time 15:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-11-05 Cont ID  
Sent By mjacobs Date 2008-11-05 Time 13:28 Rev Time 0.00
Received By mjacobs Date 2008-11-05 Time 13:28 Sent To  
Notes
2008-11-05 13:28:06BUILDING PLAN REVIEW
 PERMIT: 08100683
 ADD: 301 N. OLIVE AVE. 4TH FL.
 CONT: H.A. CONTRACTING CORP.
 TEL: (305)591-9212
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 11-5-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION
 SHALL BE INDICATED ON THE PLANS.
  
 3) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE.
  
 4) SHEET BP-1 SHOWS DOORS #4095 AND #4106 HOWEVER THE
 OTHER PAGES IN BOTH SET OF PLANS DO NOT SHOW THOSE
 DOORS. IF THESE DOORS ARE CLOSED OFF PROVIDE
 INFORMATION ON THE DRAWINGS TO REFLECT THE DOORS BEING
 DELETED. IF THESE DOORS ARE TO REMAIN, PLEASE SHOW THEM
 ON THE OTHER PAGES. SHEET BP-1 ALSO INDICATES THAT THE
 ELECTRICAL ROOM #1454 IS WILL BE UNDER THIS PERMIT:
 HOWEVER, IT IS NOT CLEAR WHAT TYPE OF CHANGES WILL BE
 MADE TO THE ROOM. ADDITIONAL INFORMATION IS REQUIRED.
 106.1.2*
  
 5) 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE & EXTENT OF THE WORK
 PROPOSED & SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 AND RULES AND REGULATIONS AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-12-18 Cont ID  
Sent By dpalmer Date 2008-12-18 Time 14:50 Rev Time 0.00
Received By dpalmer Date 2008-12-18 Time 14:50 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-11-04 Cont ID  
Sent By dpalmer Date 2008-11-04 Time 13:19 Rev Time 0.00
Received By dpalmer Date 2008-11-04 Time 13:19 Sent To  
Notes
2008-11-04 13:20:10 
  
  
  
 ** DENIED REVIEW **
  
 1) NOTE:
  
 2) NOTE: PLEASE BE SURE THE FOLLOWING CODES AS ADOPTED
 BY FS 553.73 ARE LISTED ON PLANS ACCORDINGLY. FOR
 EXAMPLE COVER SHEET INDICATES NFPA-70 ( NATIONAL
 ELECTRICAL CODE) AS THE 2002 EDITION. THIS CODE HAS NOT
 BEEN IN EFFECT IN THE STATE OF FLORIDA SINCE DECEMBER
 8TH, 2006.
 PLANS SHOULD NOTE AS FOLLOWS.
 2004 FBC W/ 2007 REVISIONS.
 2003 NFPA-101
 2002 NFPA-72
 2005 NFPA-70.
  
 ** SOME OF THESE ARE SHOWN ON ELECTRICAL PLANS HOWEVER
 COORDINATION WITH OTHER PLANS IS NEEDED. ELECTRICAL
 PLANS DO NOT LIST SPECIFIC ADOPTED CODES
  
 3) NOTE: PLEASE INCLUDE NEW LIGHTING CONTROLS FOR NEW
 AREAS PER 13-415.1.ABC.1.1, .1.2 AND .1.3.
 ** THIS IS FOR NEW INSTALLED ONLY.
 ** PLEASE VERIFY CONTROLS AS THE SYMBOL LEGEND CALL FOR
 NEW SWITCHES, YET NONE ARE SHOWN AS EXISTING OR NEW.
  
 4) NOTE: PLEASE INCLUDE LIGHTING PERFORMANCE
 CALCULATIONS PER 13-415.2, 13-415.2.ABC.1.1,.1.2.
 ** NEW BEING INSTALLED.
 ** PLEASE BE SURE TO COMPLETE FIXTURE LEGEND WITH
 SPECIFIC FIXTURES.
  
 5) NOTE: PLEASE BE SURE TO LIST THE REQUIRED LOCATIONS,
 LEVELS AND HEIGHTS OF FIRE ALARM DEVICES PER FBC
 11-4.28.1, .2 AND 3. QUOTING ANSI OR OTHER CODES IN
 LIEU OF SPECIFIC CODE REQUIRED DETAIL IS NOT PERMITTED.
  
 ** IT IS IMPORTANT TO KNOW AS THERE IS SOME INFORMATION
 NOT YET SUBMITTED THERE MAY VERY WELL BE NEW COMMENTS
 ON THE FOLLOWING REVIEW WHICH CAN NOT BE MADE AT THIS
 TIME.
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-12-15 Cont ID  
Sent By mwennerg Date 2008-12-15 Time 13:29 Rev Time 0.00
Received By mwennerg Date 2008-12-15 Time 13:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-11-07 Cont ID  
Sent By mwennerg Date 2008-11-07 Time 14:26 Rev Time 0.00
Received By mwennerg Date 2008-11-07 Time 14:26 Sent To  
Notes
2008-11-07 14:30:55***DENIED***
  
 1) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE
 SAFETY SHALL COMPLY WITH NFPA 101, 2003 EDITION.
  
 2) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE
 SPRINKLER AND FIRE ALARM REMODEL.
  
 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-11 Cont ID  
Sent By adarroug Date 2008-12-11 Time 08:42 Rev Time 0.00
Received By adarroug Date 2008-12-11 Time 08:42 Sent To  
Notes
2008-12-11 08:44:46TO "BOB"#7

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-11-10 Cont ID  
Sent By mperson Date 2008-11-10 Time 08:27 Rev Time 0.00
Received By mperson Date 2008-11-03 Time 13:56 Sent To PC
Notes
2008-11-03 13:56:53TO "BOB"#4

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2009-07-08 Cont ID  
Sent By rregueir Date 2009-07-08 Time 10:50 Rev Time 0.00
Received By rregueir Date 2009-07-08 Time 10:50 Sent To PC
Notes
2009-07-08 10:51:03PAGE M1 REVISION #4

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-12-14 Cont ID  
Sent By rregueir Date 2008-12-14 Time 15:09 Rev Time 0.00
Received By rregueir Date 2008-12-14 Time 15:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-11-05 Cont ID  
Sent By tgordon Date 2008-11-05 Time 08:18 Rev Time 0.45
Received By tgordon Date 2008-11-05 Time 08:18 Sent To  
Notes
2008-11-05 08:29:55PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) PLEASE SHOW THE SIZE OF ALL NEW DUCTS (FLEX), PER
 2004 FBC 603.2.
  
 2) ADD SYMBOLS TO THE HVAC LEGEND FOR EXISTING DUCTS
 (FLEX) AND NEW DUCTS (FLEX), OR SHOW N FOR NEW AND E
 FOR EXISTING AT THE DUCTS (FLEX) LOCATION, PER 2004 FBC
 106.1.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2008-11-10 Cont ID  
Sent By mperson Date 2008-11-10 Time 08:25 Rev Time 0.00
Received By mperson Date 2008-11-10 Time 08:25 Sent To I
Notes
2008-11-10 08:27:35NOTE: THERE IS NO PROPOSED PLUMBING WORK ON SUBMITTED
 PLANS OR A PLUMBING PERMIT BEING APPLIED FOR AT THIS
 TIME. *MRPERSON.

Review Stop Z ZONING
Rev No 1 Status N Date 2008-11-07 Cont ID  
Sent By mflis Date 2008-11-07 Time 13:38 Rev Time 0.00
Received By mflis Date 2008-11-07 Time 13:38 Sent To  
Notes
2008-11-07 13:39:17ZONING REVIEW: NOT REQUIRED
  
 ** INTERIOR RENOVATION ONLY
  
 MATT FLIS - 822-1445