Plan Review Stops For Permit 08100531 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-04-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2009-04-08 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2009-04-08 |
Time |
12:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2009-04-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2009-03-09 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2009-03-09 |
Time |
07:44 |
Sent To |
|
|
Notes |
2009-03-09 09:17:22 | BUILDING PLAN REVIEW | | PERMIT: 08100531 | | ADD: 1118 25TH STREET #7 | | CONT: COMPLETE PROPERTY MANAGEMENT INC. | | TEL: (561)626-2778 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 3/9/09 | | REVIEW: 2NDT | | ACTION: DENIED | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | INSPECTION. | | | | 3) OK | | 4) OK | | | | 5) MEZZANINE DELETED FROM DRAWINGS. | | | | 6) THE DRAWINGS NEED TO CLEARLY INDICATE THE TYPE OF | | BUILDING PER CHAPTER 6 AND TABLE 503 AND THE USE AND | | OCCUPANCY PER CHAPTER 3. THE PLANS SHOW AN OCCUPANT | | LOAD OF 25 PERSONS. NOTE: THE OFFICE AREAS AND THE | | WAREHOUSE/STORAGE AREA SHALL BE CALCULATED ACCORDING | | THE DESIGN OCCUPANT LOAD PER TABLE 1004.1.2. IS | | OCCUPANCY TYPE S1 / F1 AND BUSINESS AS INDICATED? | | | | 7) MEZZANINE DELETED FROM DRAWINGS. | | 8) MEZZANINE DELETED FROM DRAWINGS. | | | | 9) PROVIDE AN EXISTING FLOOR PLAN OF THE EXISTING AREA | | AND A PROPOSED FLOOR PLAN. | | | | 10) MEZZANINE DELETED FROM DRAWINGS. | | 11) MEZZANINE DELETED FROM DRAWINGS. | | | | 12) DETAIL #3 IS MISSING FROM THE PLANS. SUBMIT A | | DETAIL CEILING FRAMING DRAWING SHOWING ALL MATERIALS | | AND FASTENERS ALONG WITH THE TYPE OF STUDS AND SPACING. | | | | 13) MEZZANINE DELETED FROM DRAWINGS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-11-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-11-03 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-11-03 |
Time |
10:49 |
Sent To |
|
|
Notes |
2008-10-31 17:00:10 | BUILDING PLAN REVIEW | | PERMIT: 08100531 | | ADD: 1118 25TH STREET #7 | | CONT: COMPLETE PROPERTY MANAGEMENT INC. | | TEL: (561)626-2778 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 10-31-08 | | REVIEW: 1ST | | ACTION: DENIED | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | INSPECTION. | | | | 3) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | THIS CODE. | | | | 4) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION | | SHALL BE INDICATED ON THE DRAWINGS. | | | | 5) THE INFORMATION FOR THE BUILDING IS NOT LEGIBLE | | 106.1.1. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE & EXTENT OF | | THE WORK PROPOSED & SHOW IN DETAIL THAT IT WILL CONFORM | | TO THE PROVISIONS OF THIS CODE AND RELEVANT LAWS, | | ORDINANCES, AND RULES AND REGULATIONS AS DETERMINED BY | | THE BUILDING OFFICIAL. INDICATE THE SQUARE FOOTAGE OF | | THE SPACE AND THE AREA OF THE MEZZANINE. | | | | 6) THE DRAWINGS NEED TO CLEARLY INDICATE THE TYPE OF | | BUILDING PER CHAPTER 6 AND TABLE 503 AND THE USE AND | | OCCUPANCY PER CHAPTER 3. | | | | 7) THE CLEAR HEIGHT ABOVE AND BELOW THE MEZZANINE FLOOR | | CONSTRUCTION SHALL NOT BE LESS THAN 7 FEET. FBC 505.1 | | SHOWS COMPLIANCE. THE AGGREGATE AREA OF THE MEZZANINE | | WITHIN A ROOM SHALL NOT EXCEED ONE-THIRD OF THE AREA OF | | THE ROOM OR SPACE IN WHICH THEY ARE LOCATED. FBC 502.2 | | | | 8) PLEASE INDICATE THE OCCUPANT LOAD OF THE MEZZANINE | | AND THE ENTIRE SPACE ON THE DRAWINGS PER 505.4 TABLE | | 1004.1.2 AND TABLE 1607.1 | | | | 9) PROVIDE AN EXISTING FLOOR PLAN OF THE EXISTING AREA | | AND A PROPOSED FLOOR PLAN WITH ALL ELEVATION OF THE NEW | | AREA INCLUDING THE FRONT AND SIDES ELEVATIONS. | | | | 10) 110.4.2 STORAGE & FACTORY- INDUS-TRIAL OCCUPANCIES. | | IT SHALL BE THE | | RESPONSIBILITY OF THE OWNER, AGENT, PROPRIETOR OR | | OCCUPANT OF GROUP S AND GROUP F OCCUPANCIES, OR ANY | | OCCUPANCY WHERE EXCESSIVE FLOOR LOADING IS LIKELY TO | | OCCUR, TO EMPLOY A COMPETENT ARCHITECT OR ENGINEER IN | | COMPUTING THE SAFE FLOOR LOAD CAPACITY. ALL SUCH | | COMPUTATIONS SHALL BE ACCOMPANIED BY AN AFFIDAVIT FROM | | THE ARCHITECT OR ENGINEER | | STATING THE SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN | | POUNDS PER SQ FT. THE COMPUTATIONS & AFFIDAVIT SHALL BE | | FILED AS A PERMANENT RECORD OF THE BLDG DEPT. | | | | 11) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR PART | | OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR HAZARDOUS | | PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED BY THE | | BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED ON | | PLATES OF APPROVED DESIGN WHICH SHALL BE SUPPLIED & | | SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A | | CONSPICUOUS PLACE IN EACH STORY TO | | WHICH THEY RELATE. SUCH PLATES SHALL NOT BE REMOVED OR | | DEFACED, & IF LOST, REMOVED THE OWNER OF THE BUILDING | | SHALL REPLACE THEM. PLEASE SEE FBC 1603.3 FOR MORE | | INFORMATION. | | | | 12) DETAIL #3 FAILS TO INDICATE THE ATTACHMENT DETAIL | | FOR THE FLOOR JOISTS. STATE THE TYPE OF CONNECTIONS FOR | | THE FLOOR JOISTS TO THE LEDGER AND THE OUTER WALL. | | INDICATE THE GRADE AND SPECIES OF THE FLOOR JOISTS ON | | THE PLANS PER FBC 2308.8. THE PLANS FAIL TO SHOW | | COLUMNS AND WALLS SUPPORTING THE MEZZANINE. THE | | CONNECTION DETAIL FOR THE GUARDRAIL IS ALSO REQUIRED. | | | | 13) IS THE STAIRWAY BEING ENCLOSED? IF SO, THIS WILL | | MAKE THE MEZZANINE AN ENCLOSED AREA. PLEASE SHOW | | CLEARLY IF THE WALL AROUND THE STAIRS GOES TO THE DECK | | ABOVE. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-15 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-15 |
Time |
11:17 |
Sent To |
|
|
Notes |
2009-05-15 11:18:26 | DISREGARD PROVISO FROM PREVIOUS REVIEW. LPD LOCATED ON | | A-1. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-04-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-10 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-10 |
Time |
16:54 |
Sent To |
|
|
Notes |
2009-04-10 16:54:50 | ** PROVISO ** | | | | 1) NOTE: LIGHTING PERFORMANCE CALCULATIONS STILL NEED | | TO BE COMPLETED. 13-415.2 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2009-03-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-03-11 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-03-11 |
Time |
10:44 |
Sent To |
|
|
Notes |
2009-03-11 10:44:31 | ** DENIED 2ND RESUB ** | | | | *** PLEASE KNOW THAT SEVERAL NOTES FROM PREVIOUS REVIEW | | ARE STILL IN NEED OF ADDRESSING. THERE ARE ALSO SEVERAL | | NEW NOTES AS SOME INFORMATION WHICH IS ONLY NOW | | SUBMITTED DOES NOT MEET MINIMUM CODE COMPLIANCE. NOTES | | BELOW WILL BE MARKED FOR NEW COMMENTS. NOTES BELOW WILL | | ALSO BE MARKED FOR PREVIOUS REVIEW COMMENTS. | | | | 1) NOTE: PREVIOUS REVIEW: PLEASE SUBMIT PLANS SHOWING | | MINIMUM CODE COMPLIANCE FOR LIGHTING CONTROLS FOR NEW | | PER FBC 13-415.1.ABC.1.1, .1.2. THE RESPONSE LETTER | | MENTIONS *NOTES* WERE ADDED TO PLANS. THE PLANS DO NOT | | CONTAIN ANY NOTES WITH RESPECT TO MINIMUM LIGHTING | | CONTROLS. IN EITHER CASE PLACING NOTES ON THE PLANS IN | | LIEU OF DETAILS IS NOT PERMITTED. PLEASE BE SURE TO ADD | | THE SPECIFIC TYPE OF CONTROLS, TIMES ETC. | | | | 2) NOTE: PREVIOUS REVIEW: PLEASE SEE 13-415.2, | | 13-415.2.ABC.1.1 AND .1.2. THE PREVIOUS REVIEW | | REQUESTED TO SHOW LIGHTING PERFORMANCE CALCULATIONS PER | | THE SECTIONS GIVEN. THE RESPONSE MENTIONS THESE ITEMS | | ARE SHOWN ON PLANS HOWEVER THERE ARE NO LIGHTING | | PERFORMANCE CALCULATIONS PER THE SECTIONS GIVEN SHOWN | | ON PLANS. | | | | 3) NOTE: NEW COMMENT: PLEASE SEE NEW RISER WHICH NOW | | SHOWS THE MAIN SERVICE WITH A 100AMP FEED TO A 100AMP | | PANEL YET THE PANEL SCHEDULE INDICATES A 200AMP PANEL. | | THESE DO NOT CORRELATE. | | PLEASE ALSO SEE THE LOAD CALCULATIONS FOR THIS UNIT IS | | NOT CODE COMPLIANT. THE RECEPTACLE LOAD FOR EXAMPLE | | INDICATE SONLY FOUR(4) TOTAL RECEPTACLES AT 180VA EACH. | | HOWEVER PLEASE TAKE A LOOK AT THE PLANS THERE IS A | | SUBSTANTIAL AMOUNT OF MORE RECEPTACLES THAN FOUR. | | 220.12,220.14,220.44 ETC. | | | | 4) NOTE: NEW COMMENT: PLEASE SEE THE TOTAL LOAD | | CALCULATIONS AS EACH BAY INDICATES THE SAME EXACT LOADS | | WHICH IS NOT POSSIBLE. SEVERAL OF THESE UNITS HAVE BEEN | | BUILT OUT WITH A SUBSTANTIAL AMOUNT OF MORE LOAD THAN | | WHAT IS SHOWN. | | PLEASE ALSO SEE THE TOTAL OF THE LOAD CALCULATIONS | | WHICH INDICATES THE LOAD AT 440AMPS ON A 600AMP | | SERVICE. HOWEVER THE RISER CLEARLY INDICATES THIS MAIN | | SERVICE AS 600AMP EQUIPMENT WITH 400AMP FUSES. THIS | | WOULD TAKE THE LOAD OVER THE RATING OF THE OVER CURRENT | | PROTECTION PROVIDED. THIS IS NOT ONLY NOT PERMITTED IT | | IS UNSAFE AND DOES NOT MEET: | | 220,230.70,230.71,230.76,230.79, 240.4, 310.16,110.14, | | ETC. THERE TOO MANY SECTIONS TO NOTE. THE LOAD MAY NOT | | EXCEED THE SERVICE RATING. | | | | 5) NOTE: NEW COMMENT: PLEASE SEE THE OCCUPANCY | | CLASSIFICATION IS NOW LISTED AS *F*. WHAT WILL BE | | MANUFACTURED IN THIS LOCATION? THERE ARE CONCERNS OVER | | THE TYPE OF MANUFACTURING AND PRODUCTS OF STORAGE ETC | | WITH RESPECT TO ELECTRICAL PERTAINING TO POSSIBLE CLASS | | AND DIVISION LOCATIONS. | | PLEASE BE SURE TO SEE NEC 500 (ALL) FOR POSSIBLE CODE | | REQUIREMENTS. | | | | 6) NOTE: PLEASE BE AWARE OF FS 553.80(2)(B) WITH | | RESPECT TO REPEAT COMMENTS FOR CODE COMPLIANCE. THERE | | ARE SECTIONS WHICH HAVE BEEN REPEATED A SECOND TIME. | | | | ** THERE ARE STILL SEVERAL UNANSWERED ITEMS OR | | CORRECTIONS WHICH NEED TO BE MADE WHICH MAY CREATE NEW | | COMMENTS. | | | | | | ** IMPORTANT ** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-11-04 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-11-04 |
Time |
08:36 |
Sent To |
|
|
Notes |
2008-11-04 08:37:05 | | | | | | | | | ** DENIED REVIEW ** | | | | 1) NOTE: PLEASE INCLUDE NEW OR EXISTING HORNS, STROBES, | | HORN/STROBE DEVICES MEETING FBC 11-4.28.1, .2 AND .3. | | PLEASE LIST THE HEIGHTS AND LEVELS. | | | | 2) NOTE: PLEASE INCLUDE THE LIGHTING PERFORMANCE | | CALCULATIONS PER 13-415.2, 13-415.2.ABC.1.1,.1.2. | | THESE WOULD BE FOR NEW AREAS ONLY AND MAY BE SHOWN ON | | PLANS FOR TABLE 13-415.2.B | | PLEASE BE SURE TO COMPLETE THE FIXTURE LEGEND. | | ** NEW BEING INSTALLED | | | | 3) NOTE: PLEASE INCLUDE LIGHTING CONTROLS PER | | 13-415.1.ABC.1.1, .1.2 AND .1.3. ** NEW BEING INSTALLED | | ONLY REQUIRED | | | | 4) NOTE: THE RISER AS SHOWN ON PLANS IS NOT SHOWN AS IT | | EXISTS. IF EXISTING THEN PLEASE INDICATE OTHERWISE THE | | REVIEW WILL BE DONE FOR NEW EQUIPMENT UNDER CURRENT | | CODES. | | 230,220,240 ETC | | | | 5) NOTE: PLEASE SEE THE CODE SECTION REFLECTED PER | | 700.12E IS NOW DIFFERENT UNDER THE CURRENT 2005 NEC. | | THE NEW CODE SECTION IS 700.12F. IF THIS HAD BEEN THE | | ONLY COMMENT IT WOULD HAVE BEEN REDLINED. PLEASE | | CORRECT AT THIS TIME. | | | | 6) NOTE: PLEASE SEE THE PLANS NEED TO STATE THE | | FOLLOWING CODES AS A DESIGN STANDARD AT A MINIMUM. | | THESE ARE FOR THIS REVIEWER ONLY. PLEASE BE AWARE OF | | ANY COMMENTS FORM OTHER TRADES WHICH MAY HAVE ANY | | COMMENTS | | | | 2004 FBC W/2007 REVISIONS. | | 2003 NFPA-101 | | 2005 NFPA-70 | | | | 7) NOTE: PLEASE SUBMIT A COMPLETE PANEL SCHEDULE FOR | | SCOPE OF WORK. AS NO PANEL SCHEDULE WAS SHOWN WITH | | CIRCUITING LOADS ETC REVIEW OF THESE ITEMS COULD NOT BE | | DONE. PLEASE INCLUDE THE NEW AND EXISTING LOADS ON | | PANEL. | | 220, 408.4, 215.3, 230.42 ETC | | FBC 106.1.1, .1.2 FOR ADDITIONAL INFORMATION, CLARITY | | AND COORDINATION. | | | | 8) NOTE: PLEASE SUBMIT LIGHTING LEVELS FOR STAIRS UNDER | | NORMAL AND EMERGENCY CONDITIONS. PLEASE SEE NFPA-101 | | 7.8.1.3, 7.9.1.2, .2.2. | | | | | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-04-10 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2009-04-10 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2009-04-10 |
Time |
10:36 |
Sent To |
|
|
Notes |
2009-04-10 10:49:27 | ***PROVISO*** | | | | THE RESPONSE LETTER INDICATES THAT THE REAR EXIT DOES | | NOT REQUIRE PASSING THROUGH AN OFFICE. THE PLANS DO | | SHOW EXITING THROUGH OFFICE #3. PROVIDED THAT THIS | | SPACE MEETS THE DEFINITION AND REQUIREMENTS FOR A | | SINGLE EXIT, THE EXIT SIGN INSIDE OFFICE #3 MUST BE | | REMOVED. IF A SECOND EXIT IS REQUIRED, IT WOULD HAVE TO | | BE RELOCATED OUTSIDE OF THE OFFICE AREA MAKING IT | | ACCESSIBLE AND OBVIOUS. | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2009-03-16 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-03-16 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-03-16 |
Time |
12:30 |
Sent To |
|
|
Notes |
2009-03-16 13:02:26 | *****DENIED***** | | | | | | | | 05. WHAT EQUIPMENT AND/OR PROCESSES WILL BE USED AT THE | | NEW MEZZANINE LEVEL? YOUR RESPONSE WAS THAT THE SPACE | | IS FOR VIDEO GAME STORAGE AND SOME REPAIR; HOWEVER | | RESPONSE TO PREVIOUS ITEMS 6 THRU 9 INDICATES THAT THE | | STAIRS TO THE MEZZANINE ARE TO BE REMOVED THE DRAWINGS | | AND WILL BE REMOVED FROM THE IMPROVEMENT. WHERE WILL | | THE STORAGE OF THESE ITEMS BE LOCATED. | | | | 10. SHOW THE LOCATION OF EXIT LIGHTS, EMERGENCY LIGHTS, | | AND FIRE EXTINGUISHER(S) FOR THE NEW FLOOR PLAN. COULD | | NOT LOCATE THE LOCATION OF THE FIRE EXTINGUISHER(S) | | | | NEW COMMENT: | | | | AA. IT APPEARS THAT EGRESSING AT THE REAR EXIT HAS TO | | DONE THROUGH AN OFFICE. PLEASE EXPLAIN AS PER NFPA 101, | | 2003 EDITION HOW THIS ARRANGEMENT IS ACCEPTABLE. | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE THE COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-11-03 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-11-03 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-11-03 |
Time |
13:21 |
Sent To |
|
|
Notes |
2008-11-03 14:35:49 | *****DENIED***** | | | | | | 01. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 02. THE 2003 EDITION OF NFPA 101 SHALL BE REFERENCED. | | | | 03. PLEASE LIST THE FOLLOWING INFORMATION FOR THIS | | OCCUPANCY: * OCCUPANT LOAD AND EGRESS CAPACITIES * IS | | THERE A FIRE ALARM SYSTEM? * IS THERE A FIRE SPRINKLER | | SYSTEM? | | | | 04. PROVIDE AN EXISTING FLOOR LAYOUT OF THE TENANT | | SPACE. | | | | 05. WHAT EQUIPMENT AND/OR PROCESSES WILL BE USED AT THE | | NEW MEZZANINE LEVEL? | | | | 06. STAIRS SHALL COMPLY WITH 7.2.2 OF NFPA 101 - 2003 | | EDITION. | | | | 07. PROVIDE THE PRESCRIPTIVE STRENGHTS FOR THE NEW | | HANDRAILS. | | | | 08. THE STAIRS SHALL HAVE HANDRAILS ON BOTH SIDES AND | | SHALL BE CONTINUOUSLY GRASPABLE ALONG THEIR ENTIRE | | LENGHT. | | | | 09. EXPLAIN THE STAIR'S 14 RISERS @ 7-5/8" AND ITS 13 | | TREADS @ 10" AS LISTED IN THE STAIR DETAIL. | | | | 10. SHOW THE LOCATION OF EXIT LIGHTS, EMERGENCY LIGHTS, | | AND FIRE EXTINGUISHER(S) FOR THE NEW FLOOR PLAN. | | | | 11. SPECIFY THE INTERIOR WALL AND CEILING FINISH | | MATERIALS FOR THE NEW OFFICES IN TERMS OF CLASS A, | | CLASS B, OR CLASS C. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE THE COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-04-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-04-06 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-04-06 |
Time |
09:39 |
Sent To |
|
|
Notes |
2009-04-06 09:39:29 | TO "B16" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2009-03-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-03-04 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-03-04 |
Time |
09:11 |
Sent To |
|
|
Notes |
2009-03-04 09:12:02 | TO "BOB"#9 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-11-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-11-04 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-10-24 |
Time |
14:20 |
Sent To |
|
|
Notes |
2008-10-24 14:25:16 | TO "BOB"#2 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2008-11-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-11-04 |
Time |
16:06 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2008-11-04 |
Time |
16:06 |
Sent To |
|
|
Notes |
2008-11-04 16:07:47 | THREE PORTABLE A/C UNITS BEING INSTALLED MECHANICAL | | PERMIT NOT REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-04-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-04-06 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-04-06 |
Time |
11:58 |
Sent To |
|
|
Notes |
2009-04-06 13:33:05 | | | | | PASSED/PROVISO: A VENT IS REQUIRED FOR THE D.F. SECTION | | 901.2.1. -- THE CLEAR FLOOR SPACE IS REQUIRED TO BE | | FORWARD APPROACH. SECTION 11-4.15.5(1). -- REVISION | | REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2009-03-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-03-12 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-03-12 |
Time |
15:52 |
Sent To |
|
|
Notes |
2009-03-12 15:59:37 | PLUMBING PLAN REVIEW: | | DENIED: | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | ****FROM PREVIOUS REVIEW: | | | | 1. PLEASE CLEARLY INDICATE THE BUILDING CLASSIFICATION | | AND OCCUPANCY LOAD ON THE PLANS. | | PER FBC BUILDING SECTION 302.1 GENERAL. STRUCTURES OR | | PORTIONS OF STRUCTURES SHALL BE CLASSIFIED WITH RESPECT | | TO OCCUPANCY IN ONE OR MORE OF THE GROUPS LISTED BELOW. | | ****NEW PLAN SHOW BOTH A STORAGE OCCUPANCY AND AN (F) | | OCCUPANCY. IT ALSO SHOWS 3 OFFICES WHICH INDICATE | | BUSINESS OCCUPANCY. PLEASE CLARIFY. IF THIS IS A MIXED | | OCCUPANCY, PLEASE INDICATE THE TOTAL OCCUPANCY OF EACH | | OCCUPANCY. TABLES 1004.1.2 & 403.1. | | | | 2. PLEASE INDICATE ON THE RESUBMITTED PLANS THAT THE | | FACILITY HAS AN EXISTING DRINKING FOUNTAIN AND SERVICE | | SINK OR PROVIDE SAID FIXTURES ACCORDINGLY. PLEASE KNOW | | THAT THE DRINKING FOUNTAIN SHALL BE ACCESSIBLE PER THE | | FBC???2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE | | SECTIONS. | | ****CONFLICTING INFORMATION IS INDICATED ON THE | | PLANS.THE FLOOR PLAN INDICATES AN EXISTING SERVICE SINK | | AND AN EXISTING DRINKING FOUNTAIN. THERE IS ALSO AN | | EXISTING WATER COOLER, (DRINKING FOUNTAIN) DETAIL. BUT | | ON THE SANITARY RISER DIAGRAM IT INDICATES A NEW | | DRINKING FOUNTAIN AND SHOWS NO SERVICE SINK. PLEASE | | CLARIFY. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-11-04 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-11-04 |
Time |
09:51 |
Rev Time |
0.30 |
Received By |
mperson |
Date |
2008-11-04 |
Time |
09:51 |
Sent To |
|
|
Notes |
2008-11-04 10:06:25 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. PLEASE CLEARLY INDICATE THE BUILDING CLASSIFICATION | | AND OCCUPANCY LOAD ON THE PLANS. | | PER FBC BUILDING SECTION 302.1 GENERAL. STRUCTURES OR | | PORTIONS OF STRUCTURES SHALL BE CLASSIFIED WITH RESPECT | | TO OCCUPANCY IN ONE OR MORE OF THE GROUPS LISTED BELOW. | | | | A} ASSEMBLY (SEE SECTION 303): GROUPS A-1, A-2, A-3, | | AND A-5 | | | | B} BUSSINESS (SEE SECTION 304): GROUP B | | | | C} EDUCATIONAL (SEE SECTION 305): GROUP E | | | | D} FACTORY AND INDUSTRIAL (SEE SECTION 306): GROUPS F-1 | | AND F-2 | | | | E} HIGH HAZARD (SEE SECTION 307) GROUPS H-1, H-2, H-3, | | H-4, AND H-5 | | | | F} INSTITUTIONAL (SEE SECTION 308): GROUP I-1, I-2, AND | | I-3 | | | | G} MERCANTILE (SEE SECTION 309): GROUP M | | | | H} RESIDENTIAL (SEE SECTION 310): GROUPS R-1, R-2, R-3 | | AS APPLICABLE IN SECTION 101.2, AND R-4 | | | | I} STORAGE (SEE SECTION 311): GROUPS S-1 AND S-2 | | | | J} UTILITY AND MISCELLANEOUS (SEE SECTION 312): GROUP U | | | | K} DAY CARE (SEE SECTION 313): GROUP D | | | | *NOTE: THIS APPEARS TO BE A STORAGE FACILITY. PLEASE | | KNOW THAT FOR A STORAGE FACILITY PER THE FBC-2004 | | PLUMBING TABLE 403.1 MINIMUM NUMBERS OF REQUIRED | | PLUMBING FIXTURES FOR A S-1 OR S-2 OCCUPANCY ARE THE | | FOLLOWING. | | | | *WATER CLOSETS= 1 PER 100. | | *LAVATORIES= 1 PER 100. | | *DRINKING FOUNTAIN= 1 PER 1000. | | *OTHER= 1 SERVICE SINK. | | | | PLEASE INDICATE ON THE RESUBMITTED PLANS THAT THE | | FACILITY HAS AN EXISTING DRINKING FOUNTAIN AND SERVICE | | SINK OR PROVIDE SAID FIXTURES ACCORDINGLY. PLEASE KNOW | | THAT THE DRINKING FOUNTAIN SHALL BE ACCESSIBLE PER THE | | FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE | | SECTIONS. | | | | **11-4.15 DRINKING FOUNTAINS AND WATER COOLERS | | (ELAVATION DETAIL REQUIRED WITH THE FOLLOWING | | INFORMATION) | | 11-4.15.2 SPOUT HEIGHT. SPOUT HEIGHT 36" TO OUTLET | | MAXIMUM. | | 11-4.15.3 SPOUT LOCATION. FRONT OF UNIT, WATER FLOW IN | | TRAJECTORY THAT IS PARALLEL OR NEARLY PARALLEL TO FRONT | | OF THE UNIT, WATER FLOW MINIMUM OF 4" HIGH. ON AN | | ACCESSIBLE OVAL OR ROUND BOWL FLOW OF WAER IS WITHIN 3" | | OF THE FRONT OF FOUNTAIN. | | 11-4.15.4 CONTROLS. SHALL BE FRONT MOUNTED OR SIDE | | MOUNTED NEAR FRONT EDGE. | | 11-4.15.5 CLEARANCES. KNEE 27" HIGH, & 30" X 48" FLOOR | | SPACE. | | 11-4.1.3(10)(A) WHERE ONLY ONE DRINKING FOUNTAIN IS | | PROVIDED ON A FLOOR, THERE SHALL BE A DRINKING FOUNTAIN | | WHICH IS ACCESSIBLE TO INDIVIDUALS WHO USE WHEELCHAIRS | | IN ACCORDANCE WITH SECTION 11-4.15 AND ONE ACCESSIBLE | | TO THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING.(THIS | | CAN BE ACCOMMODATED BY THE USE OF A HI-LO FOUNTAIN OR | | BY SUCH OTHER MEANS AS WOULD ACHIEVE THE REQUIRED | | ACCESSIBILITY FOR EACH GROUP ON EACH FLOOR). | | | | 2. CLEARLY INDICATE THE CODE CYCLE ON THE PLANS. PER | | CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION 106.1.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | THE CURRENT CODE CYCLE FOR THE PLANS IS "FBC-2004 WITH | | 2007 REVISIONS" | | | | END OF COMMENTS: | | | | *PLEASE CALL IS THERE ARE ANY QUESTIONS. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-10-29 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-10-29 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-10-29 |
Time |
11:20 |
Sent To |
|
|
Notes |
|
|