Plan Review Details - Permit 08100424
Plan Review Stops For Permit 08100424
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-01 Cont ID  
Sent By mjacobs Date 2008-12-01 Time 08:48 Rev Time 0.00
Received By mjacobs Date 2008-12-01 Time 08:48 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-11-10 Cont ID  
Sent By mjacobs Date 2008-11-10 Time 09:25 Rev Time 0.00
Received By mjacobs Date 2008-11-10 Time 09:25 Sent To PC
Notes
2008-11-10 09:25:27BUILDING PLAN REVIEW
 PERMIT: 08100424
 ADD: 3960 WEST HAMILTON KEY DRIVE.
 CONT: CRAFT MASTER CUSTOM POOLS
 TEL: (561)798-7929
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) FBC 424.1.3.1 POOL WET DECKS SHALL BE CONSTRUCTED OF
 CONCRETE OR OTHER NONABSORBENT MATERIAL HAVING A SMOOTH
 SLIP-RESISTANT FINISH. THE DECK TYPE INDICATED ON THE
 PLANS IS "MARBLE" WHICH IS VERY SLIPPERY WHEN WET.
 PROVIDE INFORMATION SHOWING HOW THE MARBLE WILL MEET
 THIS REQUIREMENT. WITH THE MARBLE DECK THE VALUATION OF
 THE POOL WILL BE MORE THAN WHAT IS STATED ON THE
 APPLICATION. CLARIFY.
  
 4) FBC 424.1.3.1.2 POOL WET DECKS SHALL BE UNIFORMLY
 SLOPED AT A MINIMUM OF 2 PERCENT TO A MAXIMUM OF 4
 PERCENT AWAY FROM THE POOL OR TO DECK DRAINS TO PREVENT
 STANDING WATER.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-10-23 Cont ID  
Sent By btrobaug Date 2008-10-23 Time 10:47 Rev Time 0.00
Received By btrobaug Date 2008-10-23 Time 10:43 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2008-10-29 Cont ID  
Sent By mperson Date 2008-10-29 Time 16:34 Rev Time 0.00
Received By mperson Date 2008-10-29 Time 16:34 Sent To B
Notes
2008-10-29 16:34:43NOTE: POOL HEATER IS AN ELECTRIC HEAT PUMP.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-11-21 Cont ID  
Sent By adarroug Date 2008-11-21 Time 08:53 Rev Time 0.00
Received By adarroug Date 2008-11-21 Time 08:53 Sent To Z
Notes
2008-11-21 08:54:16TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-23 Cont ID  
Sent By adarroug Date 2008-10-23 Time 08:44 Rev Time 0.00
Received By adarroug Date 2008-10-23 Time 08:44 Sent To E
Notes
2008-10-23 08:45:33TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-11-10 Time   Rev Time 0.00
Received By adarroug Date 2008-10-21 Time 11:07 Sent To  
Notes
2008-10-21 11:08:12TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-10-29 Cont ID  
Sent By mperson Date 2008-10-29 Time 16:33 Rev Time 0.00
Received By mperson Date 2008-10-29 Time 16:33 Sent To G
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2008-11-25 Cont ID  
Sent By jroach Date 2008-11-25 Time 11:34 Rev Time 0.00
Received By jroach Date 2008-11-25 Time 11:34 Sent To  
Notes
2008-11-25 11:34:41PROVISO
  
 PRIOR TO FINAL INSPECTION, THE SWIMMING POOL SHALL BE
 COMPLETELY ENCLOSED BY A FENCE OR SIMILAR STRUCTURE
 WHICH IS INSTALLED TO OBSTRUCT ACCESS BY PERSONS OTHER
 THAN THE OWNERS OR OCCUPANTS OF THE RESIDENCE WITHIN
 WHICH A SWIMMING POOL IS LOCATED. BARRIERS OR FENCES
 SHALL BE AT LEAST FOUR FEET IN HEIGHT ABOVE GRADE.
 ("BABY FENCES" DO NOT SATISFY THIS REQUIREMENT....A
 PERMANENT FENCE IS REQUIRED).
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2008-10-21 Cont ID  
Sent By jroach Date 2008-10-21 Time 16:47 Rev Time 0.00
Received By jroach Date 2008-10-21 Time 16:47 Sent To  
Notes
2008-10-21 16:57:24***FAILED***
  
 1) PLEASE PROVIDE THE DIMENSION BETWEEN THE POOL
 EQUIPMENT AND THE PROPERTY LINE. MECHANICAL EQUIPMENT
 SHALL BE LOCATED A MINIMUM OF ONE (1) FOOT FROM THE
 PROPERTY LINE.
  
 2) EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE. ("BABY FENCES" DO NOT SATISFY THIS
 REQUIREMENT....A PERMANENT FENCE IS REQUIRED). IF A
 FENCE IS PROPOSED TO BE INSTALLED UNDER A SEPARATE
 PERMIT, PLEASE NOTE SUCH ON THE PLANS...OTHERWISE,
 PLEASE SHOW THE LOCATION AND HEIGHT OF THE PROPOSED
 FENCE.
  
 3) ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. PLEASE
 SEE COMMENT #2 ABOVE REGARDING SEPARATE PERMIT OR
 REVISE THE PLANS ACCORDINGLY.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved