Plan Review Stops For Permit 08100423 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-12-09 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-12-09 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-12-09 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-11-25 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-11-25 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-11-25 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-10-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-10-23 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-10-23 |
Time |
15:52 |
Sent To |
|
|
Notes |
2008-10-23 15:52:09 | 10-23-08 | | BUILDING PLAN REVIEW | | PERMIT: 08100423 | | ADD: 3109 45TH STREET #100 | | CONT: VILLA FRANCA DESIGN | | TEL: (561)575-2288 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 1ST | | ACTION: DENIED | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | INSPECTION. | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. SHOW THIS | | INFORMATION ON THE DRAWINGS. | | | | 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | THIS CODE. INDICATE THE LEVEL OF ALTERATION ON THE | | PLANS. | | | | 5) SHEET A1 SHOWS TWO OPENINGS BEING CLOSED OFF AT | | STORAGE ROOM #26 AND FUTURE EXAM ROOM #8: WILL THE | | EXISTING DOOR REMAIN IN THE STORAGE ROOM? PROVIDE A | | DETAIL DRAWING SHOWING WHAT MATERIAL WILL BE USED TO | | CLOSE THE OPENINGS, HOW THE TOP AND BOTTOM SECTION OF | | THE OPENINGS WILL BE ATTACHED TO THE EXISTING STRUCTURE | | AND HOW THE RATING OF THE EXISTING WALLS WILL BE | | MAINTAINED. A HEADER DETAIL IS REQUIRED FOR THE NEW | | OPENING IN THE 18 INCH CONCRETE WALL. THE HEADER SHALL | | CONSIST OF LINTEL OR SOME OTHER TYPE OF STRUCTURAL | | CONSTRUCTION TO HOLD THE EXISTING CONCRETE IN PLACE. | | FBC 2104.1.6 THE MINIMUM LENGTH OF END SUPPORT FOR | | LINTELS SHALL BE 4 INCHES. ADDITIONAL INFORMATION IS | | REQUIRED 106.1.2 | | | | 6) NOW THE SPACE IS ALTERED FIRE SPRINKLER PLANS ARE | | REQUIRED TO SHOW THE NEW LAYOUT OF THE FIRE SPRINKLER | | HEADS IN COMPARISON THE NEW ROOMS. THE NEW SPRINKLER | | HEAD LOCATIONS MAY BE SHOWN ON THE CEILING PLANS ON | | SHEET A3. FBC* 106.3.5.1.1(5) FS 553.79(2) | | | | 7) THE SOFFIT AND COVE LIGHT DETAILS ON SHEET A3 FAILS | | TO INDICATE HOW THE TOP TRACK OR METAL STUDS WILL BE | | ATTACHED TO THE STRUCTURE ABOVE AND WHAT TYPE OF | | FASTENERS WILL BE USED. | | | | 8) SHEET A4; THE ROOM FINISH SCHEDULE FAILS TO SHOW THE | | FINISHED OF THE WALLS. TABLE 803.5 MINIMUM INTERIOR | | FINISH CLASSIFICATION; PROVIDE INFORMATION BASED ON | | INTERIOR FINISH REQUIREMENTS BASED ON OCCUPANCY. PLEASE | | INDICATE THE FLAME SPREAD PER THIS TABLE. | | | | 9) FBC 1210.2 WALLS WITHIN 2 FEET OF URINALS AND WATER | | CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | SURFACE, T A HEIGHT OF 4 FEET. STATE THE WALL FINISHES | | FOR THE BATHROOMS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-02-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-02-18 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-02-18 |
Time |
12:06 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-12-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-01 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-01 |
Time |
15:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-10-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-10-29 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-28 |
Time |
14:57 |
Sent To |
|
|
Notes |
2008-10-29 14:49:17 | | | | | | | | | APPLICATION #08100423 ELECTRICAL PLAN REVIEW | | 3109 45TH STREET 10/28/08 | | WEST PALM BEACH, FL. | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, 2004 FBC AS AMENDED, CHAPTER 1, AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THIS PROJECT MUST COMPLY WITH CHAPTER 13 FBC. SEE | | 13-415.1ABC.1.1 FOR AUTOMATIC CONTROL REQUIREMENTS AND | | FOR LIGHTING DENSITIES. ALL THAT IS REQUIRED FOR THE | | ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE | | REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE | | CALCULATION PROCEDURES, GENERAL. | | THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR | | A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD | | DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE | | METHOD DESCRIBED IN SECTION 415.2.B.1. THE INSTALLED | | INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH | | SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR | | LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE | | DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF | | THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE | | DENSITY REQUIREMENTS. INDICATE WATTAGES ON THE FIXTURE | | SCHEDULE TO CORRELATE WITH THE ONES IN THE | | CALCULATIONS. | | | | 2} INDICATE COMPLIANCE WITH 517.13 ON THE PLANS. THIS | | CAN BE DONE IN NOTE FORM. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-12-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-12-10 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-12-10 |
Time |
10:54 |
Sent To |
|
|
Notes |
2008-12-10 11:03:00 | *****APPROVED***** | | | | | | PLAN SHEETS A1, A4, E1 & E2 WERE PREVIOUSLY STAMPED, | | INITIALED, AND DATED ON 12/02/2008; SHEET A4 WAS | | RE-STAMPED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2008-12-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-12-02 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-12-02 |
Time |
16:16 |
Sent To |
I |
|
Notes |
2008-12-02 16:35:53 | *****APPROVED***** | | | | | | PLAN SHEETS A1, A4, E1 & E2 WERE STAMPED, INITIALED, | | AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-10-31 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-31 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-10-31 |
Time |
09:56 |
Sent To |
|
|
Notes |
2008-10-31 10:04:02 | ***DENIED*** | | | | 1) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE | | SAFETY SHALL COMPLY WITH NFPA 101, 2003. | | | | 2) MINIMUM 2A-10B,C RATED FIRE EXTINGUISHERS TO BE | | MOUNTED AT LOCATIONS NOT TO EXCEED 75' TRAVEL DISTANCE. | | | | 3) PROVIDE MINIMUM INTERIOR FINISH CLASSIFICATION FOR | | WALLS AND CEILING. | | | | 4) SHEET E-2 INDICATES A FIRE ALARM SYSTEM TO INCLUDE A | | CONTROL PANEL. IF FIRE ALARM SUPERVISES AN AUTOMATIC | | FIRE SPRINKLER SYSTEM, IT SHALL BE UL CERTFICATED PRIOR | | TO FINAL INSPECTION. | | | | 5) PLEASE INDICATE THE MAXIMUM TRAVEL DISTANCE ON THE | | SAFETY FLOOR PLAN. | | | | 6) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | WITH NFPA 241. | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-05-12 |
Time |
|
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-05-12 |
Time |
16:58 |
Sent To |
M |
|
Notes |
2009-05-12 16:58:11 | GAVE TO RON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2009-04-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-22 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-22 |
Time |
11:53 |
Sent To |
M |
|
Notes |
2009-04-22 11:53:38 | TO RR DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-03-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-03-26 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-03-26 |
Time |
16:19 |
Sent To |
|
|
Notes |
2009-03-26 16:20:17 | TO "B5" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-02-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-17 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-17 |
Time |
11:00 |
Sent To |
E |
|
Notes |
2009-02-17 11:01:07 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-12-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-04 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-04 |
Time |
10:59 |
Sent To |
|
|
Notes |
2008-12-04 11:02:27 | TO "BOB"#15 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-11-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-14 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-14 |
Time |
13:35 |
Sent To |
|
|
Notes |
2008-11-14 13:39:02 | TO "BOB"#17 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-10-31 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-31 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-10-21 |
Time |
14:54 |
Sent To |
|
|
Notes |
2008-10-21 14:58:01 | TO "BOB"#12 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-05-28 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-05-28 |
Time |
15:50 |
Sent To |
PC |
|
Notes |
2009-05-28 16:00:02 | PAGE M1 REV 3 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2009-05-04 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-05-04 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-05-04 |
Time |
09:32 |
Sent To |
PC |
|
Notes |
2009-05-04 09:59:17 | REVIEW #: REVISION DELTA 3 | | ACTION: DENIED | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | REVISION HISTORY INDICATES THAT THIS IS REVISION DELTA | | 3. HOWEVER, NO DELTA 3 COULD BE FOUND ON PLANS. THERE | | IS NO INDICATION ONPLANS WHAT CHANGES WERE MADE | | SPECIFIC TO THIS REVISION. PLEASE CLEARLY IDENTIFY THE | | LOCATION OF THE CHANGES FROM THE PREVIOUSLY STAMPED | | PLANS AND RESUBMIT. SEE FBC-B 106.1.3 AS AMENDED BY THE | | CITY OF WEST PALM BEACH. | | NOTE: IT WOULD BE HELPFUL, IN ORDER TO FACILITATE A | | TIMELY REVIEW, TO REMOVE THE CLOUDS FROM PREVIOUS | | REVISIONS AND ONLY CLOUD THE AREAS BEING CHANGED | | SPECIFIC TO DELTA 3. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2009-04-02 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-04-02 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-04-02 |
Time |
11:19 |
Sent To |
|
|
Notes |
2009-04-02 11:33:14 | REVISED M-1 AND M-2 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-11-22 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-11-22 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-11-22 |
Time |
17:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-10-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-10-28 |
Time |
08:14 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-10-28 |
Time |
08:14 |
Sent To |
|
|
Notes |
2008-10-28 08:27:41 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | | | 1) PLAN A3 SHOWS BATT INSULATION LYING ON THE | | ACOUSTICAL CEILING, PER 2004 FBC 13-404.1.ABC.1 ROOF | | INSULATION SHALL NOT BE INSTALLED ON A SUSPENDED | | CEILING WITH REMOVABLE CEILING PANELS. PLEASE CORRECT. | | | | 2) PLEASE SUBMIT A COPY OF THE ASHRAE 62 (2004 OR 2007) | | SECTION THAT DEMONSTRATES THE EQUATION USED FOR THE | | OUTDOOR AIR CALCULATIONS FOR THE WAITING ROOM. SEE 2004 | | FBC/M 403.4 AND ASHRAE 62.1-2004 SECTION 6.2.6.2. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2009-04-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-04-06 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-04-06 |
Time |
09:37 |
Sent To |
|
|
Notes |
2009-04-06 09:39:26 | REVISIONS OK -- SHT P-1 & P-2. (SHT P-3 SHOWS NO | | CHANGES/REVISIONS - NO STAMPS REQUIRED) |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-12-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-15 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-15 |
Time |
12:13 |
Sent To |
|
|
Notes |
2008-12-15 12:14:14 | PROVISO: -- FORWARD APPROACH REQUIRED PER 11-4.24.5. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-11-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-11-25 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-09 |
Time |
07:42 |
Sent To |
|
|
Notes |
2008-11-25 13:50:49 | DENIED | | REFERENCE: | | FBC-2004 CHAPTER 11 | | | | ****FROM PREVIOUS REVIEW: | | | | 4. SHT A2 INTERIOR ELEVATION DETAIL (9) @ LOUNGE: | | PLEASE CORRECT/ADD THE FOLLOWING REQUIRED INFORMATION | | PER THE FBC-2004 CHAPTER 11, FLORIDA ACCESSIBLILITY | | CODE SECTION TO THE DETAIL FOR THE ACCESSIBLE SINK. | | | | *SECTION 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH, | | 30" WIDE AND 19" DEEP. (OPEN FRONT REQUIRED, REMOVE | | CABINET DOORS @ SINK). | | ****NO RESPONSE, COMMENT NOT ADDRESSED. (SCALES OUT | | JUST OVER 25" AND NO MINIMUM CLEARANCE (27") INDICATED. | | | | 5. SHEET A4 DETAILS: PLEASE ADD THE FOLLOWING REQUIRED | | INFORMATION PER THE FBC-2004 CHAPTER 11, FLORIDA | | ACCESSIBILITY CODE SECTION FOR THE FOLLOWING ACCESSIBLE | | PLUMBING FIXTURES. | | | | SECTION 11-4.15 CLEARANCES. KNEE 27" HIGH. | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | ********NEW COMMENTS******** | | | | 1B. SHT A1 SHOW CLEAR FLOOR SPACE FOR THE LOUNGE SINK | | PER SECTION 11-4.24.5 ON THE FLOOR PLAN. | | | | 2B. SHT A4 CLEAR FLOOR SPACE FOR THE DRINKING FOUNTAIN | | IS SHOWN AS A PARALLEL APPROACH. PER SECTION 11-4.15. | | SUCH UNITS SHALL HAVE A MINIMUM 30"X48" CLEAR FLOOR | | SPACE TO ALLOW A PERSON IN A WHEELCHAIR TO APPROACH THE | | UNIT FACING FORWARD. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-10-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-10-30 |
Time |
13:14 |
Rev Time |
1.30 |
Received By |
mperson |
Date |
2008-10-30 |
Time |
13:14 |
Sent To |
|
|
Notes |
2008-10-30 13:28:41 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. CLEARLY INDICATE THE CODE CYCLE ON THE PLANS. PER | | CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION 106.1.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS AND SECTION 106.5 | | RECORD RETENTION. | | THE CURRENT CODE CYCLE FOR THE PLANS IS "FBC-2004 WITH | | 2007 REVISIONS". | | | | 2. DECLARE THE LEVEL OF ALTERATION. PER FBC-2004 | | EXISTING BUILDING CHAPTER 3. | | | | 3. THE ADDRESS IS INCOMPLETE ON ALL PLAN SHEETS. THE | | SUITE NUMBER 110 IS MISSING FROM THE ADDRESS. PLEASE | | CORRECT PER FBC-2004 CHAPTER 1, (W.P.B. AS AMENDED | | SECTION 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS | | AND SECTION 106.5 RECORD RETENTION. | | | | 4. SHEET A2 INTERIOR ELEVATION DETAIL (9) @ LOUNGE: | | PLEASE CORRECT/ADD THE FOLLOWING REQUIRED INFORMATION | | PER THE FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE | | SECTION TO THE DETAIL FOR THE ACCESSIBLE SINK. | | | | *SECTION 11-4.24.2 HEIGHT. MAXIMUM 34" A.F.F. TO RIM OR | | COUNTER. (DETAIL INCORRECTLY INDICATES 3'-0") | | | | *SECTION 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH, | | 30" WIDE, AND 19" DEEP. (OPEN FRONT REQUIRED, REMOVE | | CABINET DOORS @ SINK) | | | | *SECTION 11-4.24.4 DEPTH. MAXIMUM 6-1/2" DEEP. | | | | 5. SHEET A4 DETAILS: PLEASE ADD THE FOLLOWING REQUIRED | | INFORMATION PER THE FBC-2004 CHAPTER 11, FLORIDA | | ACCESSIBILITY CODE SECTIONS FOR THE FOLLOWING | | ACCESSIBLE PLUMBING FIXTURES. | | | | *DRINKING FOUNTAIN SECTION 11-4.15. | | | | SECTION 11-4.15.4 CONTROLS. SHALL BE FRONT MOUNTED OR | | SIDE MOUNTED NEAR FRONT EDGE. | | | | SECTION 11-4.15.5 CLEARANCES. KNEE 27" HIGH. | | | | *WATER CLOSET SECTION 11-4.16. | | | | SECTION 11-4.16.5 FLUSH CONTROLS. MOUNTED ON WIDE SIDE | | MAX. 44" HIGH. | | | | 6. SHEET P-1 DETAIL (2) SANITARY PLUMBING ISOMETRIC | | DIAGRAM: PLEASE CORRECT THE FOLLOWING PER THE FBC-2004 | | PLUMBING CODE SECTIONS. | | | | A} W.C. #2 DOES NOT REFLECT THE FLOOR PLAN OF SHEET A1. | | PLEASE KNOW THAT THERE ARE TWO LAVATORIES BEING | | INDICATED IN THE ISOMETRIC, HOWEVER THE FLOOR PLAN IS | | ONLY INDICATING ONE LAVATORY. PLEASE CORRECT PER | | SECTION 401.1 AND 701.1 SCOPE. | | | | B} EXAM ROOM #4 AND #5 CLEARLY INDICATE THE FIXTURE | | TYPE ON THE ISOMETRIC. PER SECTION 401.1 AND 701.1 | | SCOPE. | | | | C} PLEASE KNOW THAT THE LABORATORY SINK PLUMBING ON | | BOTH THE SANITARY PLUMBING PLAN AND THE SANITARY | | PLUMBING ISOMETRIC DIAGRAM IS BEING INDICATED IN THE | | WRONG LOCATION AND DOES NOT REFLECT THE FLOOR PLAN OF | | SHEET A1. PLEASE CORRECT PER SECTION 701.1 SCOPE. | | | | 7. SHEET P-2 DETAIL (2) WATER PLUMBING ISOMETRIC | | DIAGRAM: PLEASE CLEARLY INDICATE THE REQUIRED FULL-OPEN | | VALVE LOCATED ON THE WATER SUPPLY PIPE TO THE WATER | | HEATER. PER FBC-2004 PLUMBING SECTION 606.1 LOCATION OF | | FULL-OPEN VALVES (7). | | | | 8. THE WATER HEATER AND HOT WATER PIPE INSULATION ARE | | MISSING FROM THE ENERGY CALCULATIONS. PER FBC-2004 | | CHAPTER 13, TABLE 13-411.1.ABC.2 MINIMUM PIPE | | INSULATION AND TABLE 13-412.1.ABC.3 PERFORMANCE | | REQUIREMENTS FOR WATER HEATING EQUIPMENT. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | *PLEASE CALL IF THERE ARE ANY QUESTIONS. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2009-04-03 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2009-04-03 |
Time |
08:50 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2009-04-03 |
Time |
08:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-10-30 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-10-30 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-10-30 |
Time |
16:53 |
Sent To |
|
|
Notes |
2008-10-30 17:02:48 | BUILDING VALUE @ $554,461 ACCORDING TO PAPA. NOTE THAT | | ALL IMPROVEMENTS PERMIT VALUE WITHIN ONE YEAR TO THIS | | BUILDING (BOTH BAYS) MAY NOT EXCEED $277,230 OR A | | LANDSCAPE PLAN MEETING ALL CODE STANDARDS IS REQUIRED. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|