Plan Review Details - Permit 08100237
Plan Review Stops For Permit 08100237 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-12-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-12-18 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-12-18 |
Time |
17:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-12-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-12-03 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-12-03 |
Time |
15:11 |
Sent To |
|
|
Notes |
2008-12-03 15:16:08 | COURTESY PARTIAL REVIEW | | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | THIS IS A CURSORY REVIEW; LIST MAY NOT BE COMPLETE | | | | 1. SEE SHEET 6, 2 1/2" EDGE DISTANCE REQUIRES A FACTOR | | OF .71. 9" SPACING HAS BEEN CIRCLED ON THE PRODUCT | | APPROVAL, 9 X .71 = 6.39, BUT INSTALLATION SCHEDULE | | SPECIFIES 7.74. SEE OTHER COMMENTS REGARDING ANCHOR | | SPACING. | | | | 2. SHUTTER CONNECTION MOUNTING TYPE SHOULD CORRELATE | | WITH THE ANCHOR CHART. YOU'VE CIRCLED ANCHOR SPACING IN | | COLUMN "D", BUT HAVE SPECIFIED P-P3, NOT SURE WHAT THAT | | MEANS IN RELATION TO THE ANCHOR CHARTS. | | | | 3. A DESIGN PRESSURE OF -70.6 HAS BEEN SPECIFIED, | | SHOULD USE THE ROW FOR 60 - 100. HOWEVER -70.6 IS VERY | | HIGH FOR A 15' STRUCTURE LOCATED IN EXPOSURE B. IT IS | | ACCEPTABLE TO EXCEED CODE COMPLIANCE BUT IF YOU STATE | | YOU ARE DESIGNING TO -70.6PSF, ANCHOR SPACING MUST | | COMPLY. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU NEED ASSISTANCE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-11-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-11-12 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-11-12 |
Time |
13:58 |
Sent To |
|
|
Notes |
2008-11-12 14:05:51 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | 1. SEE SHEET 6, SPACING IS FOR 3" EDGE DISTANCE. 2" | | EDGE DISTANCE REQUIRES A FACTOR OF .5. | | | | 2. PLEASE CLARIFY HOW YOU HAVE DETERMINED 3000PSI | | CONCRETE STRENGTH. IT STATES THAT A TEST WAS PERFORMED. | | PLEASE INDICATE WHICH TESTING METHOD WAS USED. FBC | | R301. | | | | 2ND REVIEW, NOT ADDRESSED. PUTTING A TAPCON INTO | | CONCRETE DOES NOT PROVIDE INFORMATION REGARDING THE | | STRENGTH OF THE CONCRETE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-10-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-10-17 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-10-17 |
Time |
13:55 |
Sent To |
|
|
Notes |
2008-10-17 13:55:42 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | 1. COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS | | REQUIRED. | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | 2. PLEASE CLARIFY HOW YOU HAVE DETERMINED 3000PSI | | CONCRETE STRENGTH. IT STATES THAT A TEST WAS PERFORMED. | | PLEASE INDICATE WHICH TESTING METHOD WAS USED. FBC | | R301. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-12-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-15 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-15 |
Time |
11:19 |
Sent To |
B |
|
Notes |
2008-12-15 11:19:49 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-11-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-05 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-05 |
Time |
16:25 |
Sent To |
B |
|
Notes |
2008-11-05 16:25:47 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-10-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-10-17 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-10-10 |
Time |
11:44 |
Sent To |
|
|
Notes |
2008-10-10 11:44:47 | TO "MISC" BOX#1 |
|
|
|