Plan Review Details - Permit 08100001
Plan Review Stops For Permit 08100001
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-01-15 Cont ID  
Sent By shill Date 2009-01-15 Time 17:55 Rev Time 0.00
Received By shill Date 2009-01-15 Time 17:54 Sent To  
Notes
2009-01-15 18:00:49CALCS OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-12-10 Cont ID  
Sent By shill Date 2008-12-10 Time 11:07 Rev Time 0.00
Received By shill Date 2008-12-10 Time 11:07 Sent To  
Notes
2008-12-10 11:07:41PROVISO - SUBMIT LIGHT POLE & FIXTURE CALCULATIONS
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-12-10 Cont ID  
Sent By shill Date 2008-12-10 Time 09:42 Rev Time 0.00
Received By shill Date 2008-12-10 Time 09:42 Sent To  
Notes
2008-12-10 09:47:07****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1. CALCULATIONS ARE TO BE SUBMITTED IN ACCORDANCE WITH
 FAC61G15-23.002.
  
 CALCULATIONS ARE TO BE EITHER SIGNED AND SEALED WITH A
 TITLE BLOCK ON EACH SHEET, OR AN INDEX SHEET WHICH
 IDENTIFIES EACH SHEET SHOUD BE IMPLEMENTED.
  
 2. ADDRESSED.
  
 3. THE FIRST PAGE OF THE CALCULATIONS STATE THAT THE
 BANNER WILL "BREAK AWAY @ 70 MPH". PLEASE PROVIDE
 INFORMATION REGARDING WHERE A PROVISION FOR THIS DESIGN
 CAN BE FOUND. SEE FBC1609. IF NECESSARY, PROVIDE A COPY
 OF THE REFERENCE AS WELL AS THE CODE SECTION WHERE THIS
 DESIGN IS PERMITTED. PLEASE NOTE THAT I DO NOT HAVE
 AASHTO REFERENCES AVAILABLE IN OUR OFFICE.
  
 THE DRAWING SUBMITTED DOES NOT SHOW A BANNER. IT IS
 UNCLEAR WHAT PORTION OF THIS JOB HAS BEEN DESIGNED TO
 70MPH. THE SUPPORTING DOCUMENTATION IS FOR VEHICULAR
 IMPACT TO MINIMIZE INJURY, NOT FOR WIND. IS THIS FOR
 THE BANNER STRUCTURE OR THE BANNER FABRIC? ONE SET OF
 CALCULATIONS HAS BEEN RETAINED FOR REFERENCE. A CALL
 HAS BEEN PLACED TO THE ENGINEER, YOUSSEF HACHEM, PE FOR
 CLARIFICATION. WHEN RESUBMITTING, PLEASE SUBMIT TWO
 SETS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-28 Cont ID  
Sent By shill Date 2008-10-28 Time 15:23 Rev Time 0.00
Received By shill Date 2008-10-28 Time 15:23 Sent To  
Notes
2008-10-28 15:28:45****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. CALCULATINS ARE TO BE SUBMITTED IN ACCORDANCE WITH
 FAC61G15-23.002.
  
 2. THE CALCULATIONS, PAGE 2, REFER TO INCORRECT CODE
 SECTINO, FBC1606.1.1. PLEASE REVISE; WIND IS IN FBC
 1609.
  
 3. THE FIRST PAGE OF THE CALCULATIONS STATE THAT THE
 BANNER WILL "BREAK AWAY @ 70 MPH". PLEASE PROVIDE
 INFORMATION REGARDING WHERE A PROVISION FOR THIS DESIGN
 CAN BE FOUND. SEE FBC1609. IF NECESSARY, PROVIDE A COPY
 OF THE REFERENCE AS WELL AS THE CODE SECTION WHERE THIS
 DESIGN IS PERMITTED. PLEASE NOTE THAT I DO NOT HAVE
 AASHTO REFERENCES AVAILABLE IN OUR OFFICE.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-12-05 Cont ID  
Sent By btrobaug Date 2008-12-05 Time 09:49 Rev Time 0.00
Received By btrobaug Date 2008-12-05 Time 09:48 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-10-23 Cont ID  
Sent By btrobaug Date 2008-10-23 Time 08:38 Rev Time 0.00
Received By btrobaug Date 2008-10-23 Time 08:11 Sent To B
Notes
2008-10-23 08:30:34 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 SAME COMMENT AS THE PREVIOUS REVIEW:
  
 2} PAGE # 2 ON THE ENGINEERING CALCS REFERENCES
 1606.1.1, A SECTION THAT DOES NOT EXIST IN THE 2004
 FBC. SECTION 1609.1.1 WOULD BE THE CORRECT REFERENCE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-10-06 Cont ID  
Sent By btrobaug Date 2008-10-06 Time 08:38 Rev Time 0.00
Received By btrobaug Date 2008-10-06 Time 08:12 Sent To I
Notes
2008-10-06 08:36:17 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE ADDRESS ON THE ENGINEERING REFERENCES THE WRONG
 LOCATION.AND PROJECT (COVER SHEET).
  
 2} PAGE # 2 ON THE ENGINEERING CALCS REFERENCES
 1606.1.1, A SECTION THAT DOES NOT EXIST IN THE 2004
 FBC. SECTION 1609.1.1 WOULD BE THE CORRECT REFERENCE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-22 Cont ID  
Sent By adarroug Date 2008-10-22 Time 14:52 Rev Time 0.00
Received By adarroug Date 2008-10-22 Time 14:52 Sent To E
Notes
2008-10-22 14:52:53TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-06 Cont ID  
Sent By btrobaug Date 2008-10-06 Time 08:38 Rev Time 0.00
Received By btrobaug Date 2008-10-06 Time 08:12 Sent To I
Notes
***NONE***