Plan Review Details - Permit 08090597
Plan Review Stops For Permit 08090597
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-11-03 Cont ID  
Sent By lmartine Date 2008-11-03 Time 13:36 Rev Time 0.00
Received By lmartine Date 2008-11-03 Time 13:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-03 Cont ID  
Sent By shill Date 2008-10-03 Time 10:25 Rev Time 0.00
Received By shill Date 2008-10-03 Time 10:25 Sent To  
Notes
2008-10-03 10:26:28****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 FS481. ONE SET WAS NOT SIGNED, SEALED AND DATED.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-10-31 Cont ID  
Sent By mwennerg Date 2008-10-31 Time 14:37 Rev Time 0.00
Received By mwennerg Date 2008-10-31 Time 14:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-10-07 Cont ID  
Sent By mawillia Date 2008-10-07 Time 13:18 Rev Time 0.00
Received By mawillia Date 2008-10-07 Time 13:07 Sent To  
Notes
2008-10-07 13:18:08*****PROVISO*****
  
  
 THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN
 THE BELOW ITEM AS WELL OTHER REVIEWERS' COMMENTS HAVE
 BEEN ADDRESSED
  
 1. ON THE APPROPIATE EXTERIOR ELEVATION FRONTING 25TH
 STREET, DISPLAY THE NUMERICAL ADDRESS ON THE STRUCTURE
 OF THE BUILDING. AS PER WEST PALM BEACH CODE, THE
 NUMBERS SHALL BE NO LESS THAN 6" IN HEIGHT - 1" IN
 WIDTH AND SHALL CONTRAST TO THE BACKGROUND OF THE
 BUILDING.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-17 Cont ID  
Sent By adarroug Date 2008-10-17 Time 08:46 Rev Time 0.00
Received By adarroug Date 2008-10-17 Time 08:46 Sent To  
Notes
2008-10-21 09:53:10TO "COMM" BD#9
2008-10-17 08:47:14WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-07 Cont ID  
Sent By mawillia Date 2008-10-07 Time 13:07 Rev Time 0.00
Received By mawillia Date 2008-09-24 Time 12:53 Sent To  
Notes
2008-10-06 11:09:2010/6/08--FIRE THE LAST TO REVIEW. PLANS TAKEN OFF THE
 BD AND ROUTED TO MIKE WILLIAMS
2008-09-24 12:54:01TO "COMM" BD#12

Review Stop Z ZONING
Rev No 2 Status P Date 2008-10-23 Cont ID  
Sent By lfranco Date 2008-10-23 Time 18:12 Rev Time 0.00
Received By lfranco Date 2008-10-23 Time 18:12 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-10-03 Cont ID  
Sent By lfranco Date 2008-10-03 Time 15:09 Rev Time 0.00
Received By lfranco Date 2008-10-03 Time 15:09 Sent To  
Notes
2008-10-03 15:37:27PLANNING AND ZONING: **** FAILED *****
  
 1. PROVIDE RESPONSES TO COMMENTS IN WRITING.
  
 2. PURSUANT TO SECTION 94-211(D)(5)C. - PROVIDE
 CALCULATIONS FOR THE FACADE'S CLEAR GLAZING. INCLUDING
 BUT NOT LIMITED TO THE PERCENTAGE OF REQUIRED AND
 PROVIDED. A MINIMUM OF 50% CLEAR GLAZED AREA OF THE
 FACADE, BETWEEN TWO AND EIGHT FEET (SHOW AREA WITH
 DASHED LINES ACCORDINGLY) FROM THE GROUND SHALL BE
 PROVIDED.
  
 3. THE FOLLOWING COMMENTS ARE FOR THE WINDOWS LOCATED
 ON THE WEST SIDE OF THE FACADE, THEY ARE AS FOLLOWS:
  
 A. PURSUANT TO SECTION 94-211(D)(7) - WINDOWS SHALL BE
 VERTICAL OR SQUARE IN PROPORTION. THE PROPOSED WINDOWS
 DO NOT COMPLY WITH THE PROPORTION REQUIREMENT;
 B. PURSUANT TO PURSUANT TO SECTION 94-211(D)(9),
 MULTIPLE WINDOWS IN THE SAME ROUGH OPENING SHALL BE
 SEPARATED BY A FOUR-INCH WIDE POST AND SIT ON ONE
 CONTINUOUS SILL (THE SILL IS NOT SHOWN); AND,
 C. PURSUANT TO SECTION 94-211(D)(10) - OPENING SHALL BE
 A MINIMUM OF TWO FEET FROM BUILDING CORNERS. PROVIDE
 DIMENSION ON PLANS ACCORDINGLY.
 D. PURSUANT TO SECTION 94-211(D)(13), ALL WINDOWS,
 SHALL BE OPERABLE. ACCORDING TO WINDOW SCHEDULE ON PAGE
 A-2, WINDOW "B" IS DEPICTED AS FIXED.
  
 4. REVISE SHEET A-1 "SOUTH ELEVATION" AS PROPOSED OR
 SIMILAR, SINCE IT IS NOT THE DEMOLITION ELEVATION AS
 SHOWN ON SHEET D-1.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME AT THE
 NUMBER BELOW.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  