Plan Review Details - Permit 08090534
Plan Review Stops For Permit 08090534
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-11-17 Cont ID  
Sent By shill Date 2008-11-17 Time 10:22 Rev Time 0.00
Received By shill Date 2008-11-17 Time 10:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-10-27 Cont ID  
Sent By shill Date 2008-10-27 Time 14:10 Rev Time 0.00
Received By shill Date 2008-10-27 Time 14:10 Sent To  
Notes
2008-10-27 14:23:55****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. SEE PAGE 14 OF THE PRODUCT APPROVAL. A 3" EDGE
 DISTANCE REQUIRES A FACTOR OF .83.
  
 2. THE "SHUTTER CONNECTION MOUNTING TYPE" SHOULD
 CORRELATE WITH THE ANCHOR CHARTS ON THE PRODUCT
 APPROVAL. IT APPEARS THAT YOU ARE USING MOUNTING TYPES
 A, D, AND I. PLEASE NOTE THAT, IF THE ANCHOR SPACING
 WERE COMPLIANT (SEE COMMENT #1), THIS PERMIT WOULD NOT
 HAVE BEEN DENIED FOR THIS REASON ONLY.
  
 3. ACCORDION SHUTTERS ARE, TO MY KNOWLEDGE, ALWAYS
 INSTALLED VERTICALLY (NOT HORIZONTALLY AS NOTED ON THE
 INSTALLATION SCHEDULE). PLEASE REVISE. ALSO PLEASE
 REVISE SPANS. FOR INSTANCE, OPENING 4 SPECIFIES A 209"
 SPAN. THIS EXCEEDS THE SPAN ALLOWED. FOR ACCORDION
 SHUTTERS, THE SPAN EQUALS BLADE LENGTH.
  
 THE INSTALLATION SCHEDULE SUBMITTED DID NOT ADDRESS THE
 COMMENTS; ALL INFORMATION IS THE SAME EXCEPT FOR THE
 SHUTTER SPAN. PLEASE HAVE THE QUALIFIER REVIEW THE
 COMMENT LIST AND THE INSTALLATION SCHEDULE BEFORE
 RESUBMITTING. IF YOU NEED ASSISTANCE, PLEASE HAVE THE
 QUALIFIER CONTACT ME.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-10-17 Cont ID  
Sent By shill Date 2008-10-17 Time 10:17 Rev Time 0.00
Received By shill Date 2008-10-17 Time 10:17 Sent To  
Notes
2008-10-17 10:23:37****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. SEE PAGE 14 OF THE PRODUCT APPROVAL. A 3" EDGE
 DISTANCE REQUIRES A FACTOR OF .83.
  
 2. THE "SHUTTER CONNECTION MOUNTING TYPE" SHOULD
 CORRELATE WITH THE ANCHOR CHARTS ON THE PRODUCT
 APPROVAL. IT APPEARS THAT YOU ARE USING MOUNTING TYPES
 A, D, AND I. PLEASE NOTE THAT, IF THE ANCHOR SPACING
 WERE COMPLIANT (SEE COMMENT #1), THIS PERMIT WOULD NOT
 HAVE BEEN DENIED FOR THIS REASON ONLY.
  
 3. ACCORDION SHUTTERS ARE, TO MY KNOWLEDGE, ALWAYS
 INSTALLED VERTICALLY (NOT HORIZONTALLY AS NOTED ON THE
 INSTALLATION SCHEDULE). PLEASE REVISE. ALSO PLEASE
 REVISE SPANS. FOR INSTANCE, OPENING 4 SPECIFIES A 209"
 SPAN. THIS EXCEEDS THE SPAN ALLOWED. FOR ACCORDION
 SHUTTERS, THE SPAN EQUALS BLADE LENGTH.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-10-06 Cont ID  
Sent By shill Date 2008-10-06 Time 14:09 Rev Time 0.00
Received By shill Date 2008-10-06 Time 14:09 Sent To  
Notes
2008-10-06 14:12:11****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____ 1. PROVIDE BUILDING HEIGHT ON THE PLAN. DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT
 OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16.
  
 _XX_ 2. COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR
 PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106. TWO SETS REQUIRED.
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 ____ 3. FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____ 4. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.
  
 ____ 5. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS
 WILL BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH
 THE INSTALLATION SCHEDULE, ITEM 2 ABOVE.
  
 _XX_ 6. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE
 FOR EXPOSURE B. NOTE THAT THE DEFINITION FOR EXPOSURE C
 HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-11-03 Cont ID  
Sent By adarroug Date 2008-11-03 Time 14:05 Rev Time 0.00
Received By adarroug Date 2008-11-03 Time 14:05 Sent To B
Notes
2008-11-03 14:06:10TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-10-22 Cont ID  
Sent By adarroug Date 2008-10-22 Time 13:51 Rev Time 0.00
Received By adarroug Date 2008-10-22 Time 13:51 Sent To B
Notes
2008-10-22 13:52:11TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-07 Cont ID  
Sent By adarroug Date 2008-10-07 Time 15:45 Rev Time 0.00
Received By adarroug Date 2008-10-07 Time 15:45 Sent To B
Notes
2008-10-07 15:45:52TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-06 Cont ID  
Sent By shill Date 2008-10-06 Time 14:12 Rev Time 0.00
Received By shill Date 2008-09-23 Time 10:39 Sent To  
Notes
2008-09-23 10:39:21TO "MISC" BOX#1