Plan Review Details - Permit 08090384
Plan Review Stops For Permit 08090384
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2008-10-23 Cont ID  
Sent By jnguyen Date 2008-10-23 Time 13:16 Rev Time 0.00
Received By jnguyen Date 2008-10-08 Time 13:00 Sent To  
Notes
2008-10-23 13:16:22I HAVE ISSUED THIS IN COMMUNITYPLUS UNDER THE
 SEQUENTIAL UNIT RECORD 0039 OF THE BUS SHELTER PCN#
 74-43-43-09-13-000-0080, WHICH HAS AN ADDRESS @ 140
 CLEARWATER DR - RESTROOM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-11-21 Cont ID  
Sent By jwitmer Date 2008-11-21 Time 07:37 Rev Time 1.55
Received By jwitmer Date 2008-11-21 Time 07:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-09-29 Cont ID  
Sent By jwitmer Date 2008-09-29 Time 08:52 Rev Time 2.22
Received By jwitmer Date 2008-09-29 Time 08:52 Sent To  
Notes
2008-09-29 08:59:32BUILDING PLAN REVIEW
 PERMIT: 08090384
 ADD: 150 CLEARWATER DRIVE
 CONT: CATALFUMO
 TEL: (561)694-8853
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
 MASONARY PUBLIC RESTROOM FACILITY.
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1C) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS SHEET
 S-3 NEEDS TO UPDATE SUPPLEMENTS OF THE 2007SUPPLEMENTS.
  
 1D) THE PERMIT APPLICATION UNDER ADDRESS IS INDICATED
 AS 150 CLEARWATER DRIVE, THIS IS A SITE ADDRESS AND
 WILL REQUIRE A SEPERATE ADDRESS FOR THE RESTROOMS.
 PLEASE CONTACT JAMES JUDGE AT (561)822-1226, 106.1.2
 ADDITIONAL INFORMATION REQUIRED.
  
 1E) THE PERMIT APPLICATION INDICATES A MASONARY PUBLIC
 RESTROOM FACILITY TO BE CONSTRUCTED. PLANS SUBMITTED
 ARE TWO SETS OF A6 & A7 AND SEVEN 2OF 65 CIVIL
 DRAWINGS. THERE WERE NO PLANS ACTAULLY SUBMITTED FOR
 THE RESTROOM. THE REVIEW WILL BE COMPLETED USING THE
 A1-A5, S1-S3 OF THE GENERAL SITE IMPROVEMENT PERMIT SET
 OF PLANS WHICH THESE PLANS ARE A PART OF. PLEASE
 PROVIDE THE REQUIED (2) SETS OF PLANS WITHIN THIS
 PERMIT APPLICATION FOR COMPLIANCE WITH MINIMUM PLAN
 REVIEW CRITERIA FOR COMMERCIAL BUILDINGS 106.3.5.1.1.
 SITE PLAN
 OCCUPANCY GROUP REQUIREMENTS SHALL BE DETERMINED
 MINIMUMTYPE OF CONSTRUCTION SHALL BE DETERMINED PLEASE
 PROVIDE THE MINIMUM BUILDING TYPE CONSTRUCTION. TABLE
 503/ TABLE 601
 SOILS CONDITION
 BUILDING ENVELOPE COMPONENTS
  
 1F) AS OF 9-29-08 PERMIT FEES HAVE NOT BEEN PAID, FEES
 ARE TO BE PAID AT TIME OF PERMIT APPLICATION. FEES OWED
 ARE $3,085.91. CITY CODE OF ORDINANCES18.1(D) ALL
 PERMIT FEES MUST BE PAID IN FULL AT TIME OF PERMIT
 APPLICATION.
  
 2) PLEAS E SUBMIT 2 ORIGINALS SIGNED AND SEALED SOILS
 REPORTS. 1802.2.1 QUESTIONABLE SOIL. WHERE THE
 SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE
 A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS
 CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE
 THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF
 SECTIONS 1802.4 THROUGH 1802.6 .
  
 3) SHEET A-2 & DETAILS ON A-3 DO NOT INDICATE
 COMPLIANCE WITH 1203.2 WITH 50% OF THE REQUIRED
 VENTILATION AT LEAST 3 FEET ABOVE THE THE EAVE OR
 CORNICE VENTS.
  
 4) 1209.2 ATTIC SPACE. AN OPENING NOT LESS THAN 20
 INCHES BY 30 INCHES SHALL BE PROVIDED TO ANY ATTIC AREA
 HAVING A CLEAR HEIGHT OF OVER 30 INCHES.
  
 5) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE
 2 COPIES, 3 IF THRESHOLD OR RESIDENT INSPECTOR OF
 PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS
 FOLLOWS:
 5A)WALL LOUVERS RULE 9B-72 (31) (C)
 5B) LOUVERED EXTERIOR DOORS RULE 9B-72(31) (A)
 5C) TRUSS ANCHORS RULE 9B-72(31) (G)
 5D) ROOFING ASSEMBLIES, UNDERLAYMENTS, ROOF TILE
 ADHESIVES, ROOF TILES AND OR ANY PART OF AN INTEGRAL
 PART OF ANY ROOFING ASSEMBLY.
  
 6) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT
 IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT
 HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR
 LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 7) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 8) PLANS NOR THE NOTES ON S-3 DO NOT PROVIDE
 INFORMATION ON TERMITE TREATMENT AS PER SECTION 1816.1,
 OR FOR A VAPOR BARRIER AS REQUIRED IN 1816.1.4.
  
 9) SHEET A-3 EAVE DETAIL# 4 WILL NEED TO COMPLY WITH
 1503.6 PROTECTION AGAINST DECAY AND TERMITES. GUTTERS
 WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS WITH
 EAVES OF LESS THAN 6 INCHES (152 MM) HORIZONTAL
 PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF
 ABOVE ANOTHER ROOF. CONDENSATE LINES AND ROOF
 DOWNSPOUTS SHALL DISCHARGE AT LEAST 1 FOOT (305 MM)
 AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY
 UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS.
  
 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-03-31 Cont ID  
Sent By dpalmer Date 2009-03-31 Time 08:35 Rev Time 0.00
Received By dpalmer Date 2009-03-30 Time 17:03 Sent To  
Notes
2009-03-31 08:35:47REV SHEETS 1-5
  
 REDLINED SHEET E-3, AS SEPARATE PERMIT REQUIRED FOR LV
 CAMERAS

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-11-10 Cont ID  
Sent By dpalmer Date 2008-11-10 Time 16:09 Rev Time 0.00
Received By dpalmer Date 2008-11-10 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-09-30 Cont ID  
Sent By dpalmer Date 2008-09-30 Time 10:19 Rev Time 0.00
Received By dpalmer Date 2008-09-30 Time 10:19 Sent To  
Notes
2008-09-30 10:20:07** DENIED REVIEW **
  
 1) NOTE: PERMIT APPLICATION FEE WAS NOT PAID. FEES ARE
 REQUIRED TO BE PAID AT TIME OF PERMIT APPLICATION. FBC
 108.3
  
 2) NOTE: NO ELECTRICAL PLANS SUBMITTED AND INCLUDED.
 PLEASE SEE THE 2005 NEC FOR MINIMUM ELECTRICAL DESIGN.
 PLEASE BE SURE TO SEE 230.70,.71,72,76,79,240,250.32,25
 0.50,215.5,,225.31-225.39 ETC
 FBC 106.3.5.1.2
  
 3) NOTE: PLEASE SEE FBC CHAPTER 13 FOR ANY MINIMUM
 DESIGNS REQUIRED.
  
  
  
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-11-14 Cont ID  
Sent By mwennerg Date 2008-11-14 Time 10:30 Rev Time 0.00
Received By mwennerg Date 2008-11-14 Time 10:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-10-03 Cont ID  
Sent By mwennerg Date 2008-10-03 Time 14:23 Rev Time 0.00
Received By mwennerg Date 2008-10-03 Time 14:23 Sent To  
Notes
2008-10-03 14:25:52***DENIED***
  
 1) ACCESS TO 2A-10B,C RATED FIRE EXTINGUISHER SHALL BE
 PROVIDED.
  
 2) SEE COMMENTS REGARDING ADDRESSING FOR SPECIFIC
 STRUCTURE.
  
 3) LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003
 EDITION.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-04-14 Cont ID  
Sent By mjacobs Date 2009-04-14 Time 13:59 Rev Time 0.00
Received By mjacobs Date 2009-04-14 Time 13:59 Sent To E
Notes
2009-04-14 13:59:40SENT TO DP DESK. MJ

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-03-05 Cont ID  
Sent By adarroug Date 2009-03-05 Time 13:27 Rev Time 0.00
Received By adarroug Date 2009-03-05 Time 13:27 Sent To  
Notes
2009-03-05 13:30:07TO "COMM" BD#9

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-11-05 Cont ID  
Sent By adarroug Date 2008-11-05 Time 10:23 Rev Time 0.00
Received By adarroug Date 2008-11-05 Time 10:23 Sent To  
Notes
2008-11-05 10:23:52TO "COMM" BD#35

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-24 Cont ID  
Sent By adarroug Date 2008-09-24 Time 09:12 Rev Time 0.00
Received By adarroug Date 2008-09-24 Time 09:12 Sent To B
Notes
2008-09-24 09:15:22TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-03 Cont ID  
Sent By mwennerg Date 2008-10-03 Time 14:28 Rev Time 0.00
Received By mwennerg Date 2008-09-17 Time 11:24 Sent To  
Notes
2008-09-17 11:27:39TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-04-03 Cont ID  
Sent By kstevens Date 2009-04-03 Time 15:07 Rev Time 0.00
Received By kstevens Date 2009-04-03 Time 15:06 Sent To  
Notes
2009-04-03 15:07:29REVISIONS OK -- SHT M-1 & M-2

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-11-24 Cont ID  
Sent By kstevens Date 2008-11-24 Time 16:44 Rev Time 0.00
Received By kstevens Date 2008-11-24 Time 16:44 Sent To B
Notes
2008-11-24 16:51:12 
  
  
  
 PASSED/PROVISO
 SHT M-2 REVISION REQUIRED. THE VENT UPSTREAM OF THE P-6
 MOP SINK IS A HORIZONTAL DRY VENT WHICH IS NOT
 APPROVED. THE P-1 W/C IN THE WOMEN'S ACCESSIBLE STALL
 IS NOT VENTED AND DOES NOT REFLECT THE FLOOR PLAN. THE
 FLOOR DRAIN ON THE SANT. RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN. THE FLOOR PLAN SHOWS THE CONNECTION
 UPSTREAM OF THE SECOND P-2 WATER CLOSET BUT IS SHOWN
 DOWNSTREAM OF THE 1ST P-2 W/C. PLEASE CORRELATE. SUBMIT
 REVISION AS SOON AS POSSIBLE SO AS NOT TO HOLD UP
 INSPECTIONS.
  
  
  
  
 .

Review Stop Z ZONING
Rev No 3 Status N Date 2009-03-12 Cont ID  
Sent By mflis Date 2009-03-12 Time 08:54 Rev Time 0.00
Received By mflis Date 2009-03-12 Time 08:54 Sent To  
Notes
2009-03-12 08:55:10ZONING REVIEW (PLUMBING AND ELECTRICAL MODIFICATIONS) :
 NOT REQUIRED
  
 ** DRAWINGS REVIEWED; NO ZONING REQUIRED FOR E&P
 CHANGES
  
 MATT FLIS - 822-1445

Review Stop Z ZONING
Rev No 2 Status P Date 2008-11-07 Cont ID  
Sent By mflis Date 2008-11-07 Time 08:50 Rev Time 0.00
Received By mflis Date 2008-11-07 Time 08:50 Sent To  
Notes
2008-11-07 08:50:46ZONING REVIEW: PASSED
  
 ** REFER TO SITE IMPROVEMENTS PERMIT FOR RESTROOM
 LOCATION
  
 MATT FLIS - 822-1445

Review Stop Z ZONING
Rev No 1 Status F Date 2008-09-23 Cont ID  
Sent By mflis Date 2008-09-23 Time 13:30 Rev Time 0.00
Received By mflis Date 2008-09-23 Time 13:30 Sent To  
Notes
2008-09-23 13:30:58ZONING REVIEW: FAILED
  
 ** NO RESTROOM DRAWINGS INCLUDED WITH PERMIT SET
  
 MATT FLIS - 822-1445


Account Summary | Usage Policy | Privacy Policy