Plan Review Details - Permit 08090375
Plan Review Stops For Permit 08090375
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-11-18 Cont ID  
Sent By mjacobs Date 2008-11-18 Time 07:28 Rev Time 0.00
Received By mjacobs Date 2008-11-18 Time 07:28 Sent To PC
Notes
2008-11-18 07:32:52NO ELECTRICAL WORK WITH THIS PERMIT; NO ELECTRICAL
 PAGES WERE SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-11-05 Cont ID  
Sent By mjacobs Date 2008-11-05 Time 09:52 Rev Time 0.00
Received By mjacobs Date 2008-11-05 Time 09:52 Sent To  
Notes
2008-11-05 09:52:53BUILDING PLAN REVIEW
 PERMIT: 08090375
 ADD: 307 EVERNIA AVE#200
 CONT: RAYMOND H. NORDINE
 TEL: (561)655-1912
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 11-5-08
 REVIEW: 3RD
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) OK
 3) OK
 4) OK
 5) OK
  
 **NO RESPONSE NOT ADDRESSED**
 6) THE CLAIMED VALUATION THE PERMIT APPLICATION IS LOW.
 FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST EXCLUDING
 LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD)
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER FBC
 108.3*.
  
 7) OK.
 8) OK
  
 **INDICATE THE TYPE OF WALL FINISHES AS REQUESTED. THE
 NOTE ON SHEET A-2 IS INSUFFICIENT**
 NEW: (A) THE NEW BATHROOM ADDED ON THE PLANS NEEDS TO
 INDICATE THE WALL AND FLOOR FINISHES IN COMPLIANCE WITH
 FBC 1210. WALLS WITHIN 2 FEET OF URINALS AND WATER
 CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT
 SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FINISH FLOOR.
 NOTE: PAINT ON DRYWALL IN NOT CONSIDERED A HARD
 SURFACE.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-10-17 Cont ID  
Sent By mjacobs Date 2008-10-17 Time 10:52 Rev Time 0.00
Received By mjacobs Date 2008-10-17 Time 10:52 Sent To  
Notes
2008-10-17 10:52:23 
  
  
 BUILDING PLAN REVIEW
 PERMIT: 08090375
 ADD: 307 EVERNIA AVE#200
 CONT: RAYMOND H. NORDINE
 TEL: (561)655-1912
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 10-17-08
 REVIEW: 2ND
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) OK
  
 NOTED: HOWEVER, SHEET A-2 FAILS TO INDICATE THE
 LOCATION OF THE SPRKILER HEAD IN THE NEW BATHROOM AND
 REMODELED SUPPLY CL. ROOM.
 3) IF THIS BUILDING HAS A SPRINKLER SYSTEM, PLEASE
 STATE THIS INFORMATION ON THE PLANS. NOW THE SPACE IS
 ALTERED SHOW THE LAYOUT AND LOCATION OF THE SPRINKLER
 HEADS IN RELATION TO THE NEW ROOMS; THIS INFORMATION
 CAN BE SHOW ON THE CEILING PLANS WHICH IS ALSO MISSING
 FROM THE DRAWINGS. FBC 106.3.5.1.1(5) FS 553.79(2).
  
 4) OK
  
 THE TOP TRACK WAS ADDRESSED HOWEVER; NO INFORMATION WAS
 GIVEN FOR THE BOTTOM TRACK.
 5) WALL TYPES W-1 AND W-2 FAIL TO INDICATE HOW THE TOP
 AND BOTTOM TRACK WILL BE FASTEN TO THE RESPECTIVE
 STRUCTURE. STATE THE TYPE OF FASTENERS TO BE USED TO
 HOLD THE TRACK IN PLACE AND THE SPACING OF THE
 FASTENERS. ADDITIONAL INFORMATION REQUIRED 106.1.2
  
  
 **NO RESPONSE NOT ADDRESSED**
 6) THE CLAIMED VALUATION THE PERMIT APPLICATION IS LOW.
 FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST EXCLUDING
 LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD)
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER FBC
 108.3*.
  
 7) OK.
 8) OK
 NEW: (A) THE NEW BATHROOM ADDED ON THE PLANS NEEDS TO
 INDICATE THE WALL AND FLOOR FINISHES IN COMPLIANCE WITH
 FBC 1210. WALLS WITHIN 2 FEET OF URINALS AND WATER
 CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT
 SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FINISH FLOOR.
 NOTE: PAINT ON DRYWALL IN NOT CONSIDERED A HARD
 SURFACE.
  
 (B) BATHROOMS SHALL BE MECHANICALLY VENTILATED IN
 ACCORDANCE WITH THE FLORIDA BUILDING MECHANICAL CODE.
 1203.4.2.1. INDICATE THE VENTILATION SYSTEM FOR THE
 BATHROOM.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-09-19 Cont ID  
Sent By mjacobs Date 2008-09-19 Time 10:38 Rev Time 0.00
Received By mjacobs Date 2008-09-18 Time 15:31 Sent To  
Notes
2008-09-19 10:38:16BUILDING PLAN REVIEW
 PERMIT: 08090375
 ADD: 307 EVERNIA AVE
 CONT: RAYMOND H. NORDINE
 TEL: (561)655-1912
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 9-19-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) INDICATE THE OCCUPANT LOAD OF EACH NEW CONFERENCE
 ROOM AND THE TOTAL OCCUPANCY OF THE SPACE PER TABLE
 1004.1.2.
  
 3) IF THIS BUILDING HAS A SPRINKLER SYSTEM, PLEASE
 STATE THIS INFORMATION ON THE PLANS. NOW THE SPACE IS
 ALTERED SHOW THE LAYOUT AND LOCATION OF THE SPRINKLER
 HEADS IN RELATION TO THE NEW ROOMS; THIS INFORMATION
 CAN BE SHOW ON THE CEILING PLANS WHICH IS ALSO MISSING
 FROM THE DRAWINGS. FBC 106.3.5.1.1(5) FS 553.79(2).
  
 4) TABLE 803.5 MINIMUM INTERIOR FINISH CLASSIFICATION;
 PROVIDE INFORMATION BASED ON INTERIOR FINISH
 REQUIREMENTS BASED ON OCCUPANCY. INDICATE THE INTERIOR
 FINISHES ON THE PLANS.
  
 5) WALL TYPES W-1 AND W-2 FAIL TO INDICATE HOW THE TOP
 AND BOTTOM TRACK WILL BE FASTEN TO THE RESPECTIVE
 STRUCTURE. STATE THE TYPE OF FASTENERS TO BE USED TO
 HOLD THE TRACK IN PLACE AND THE SPACING OF THE
 FASTENERS. ADDITIONAL INFORMATION REQUIRED 106.1.2
  
 6) THE CLAIMED VALUATION THE PERMIT APPLICATION IS LOW.
 FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST EXCLUDING
 LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD)
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER FBC
 108.3*.
  
 7) FBC 11-7(2) (I) A PORTION OF THE RECEPTIONIST
 COUNTER SHALL MAXIMUM HEIGHT OF 36 INCHES AND MINIMUM
 WIDTH OF 36 INCHES. PLEASE SHOW THIS INFORMATION ON THE
 SUBMITTED DRAWINGS. THE WALLS AROUND THE RECEPTIONIST
 SHOW A 42 INCH HIGH WALL.
  
 8) INDICATE THE TYPE AND HEIGHT OF THE BUILDING PER FBC
 TABLE 601 AND TABLE 503.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-12-02 Cont ID  
Sent By btrobaug Date 2008-12-02 Time 13:08 Rev Time 0.00
Received By btrobaug Date 2008-12-02 Time 12:00 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2008-10-23 Cont ID  
Sent By btrobaug Date 2008-10-23 Time 14:16 Rev Time 0.00
Received By btrobaug Date 2008-10-23 Time 14:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-11-18 Cont ID  
Sent By btrobaug Date 2008-09-30 Time 09:25 Rev Time 0.00
Received By rregueir Date 2008-09-30 Time 07:59 Sent To  
Notes
2008-11-18 09:13:35REVIEW STATUS CHANGED TO "FAIL". SCOPE OF WORK HAS
 CHANGED AND ELECTRICAL APPLICATION HAS BEEN DETACHED
 FROM THE MASTER. REVIEWS TO BE DONE UNDER ELECTRICAL
 PERMIT #08090736. RJR
2008-09-30 09:25:48 
  
 ONE EXIT LIGHT THIS PERMIT./WRT.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2008-11-17 Cont ID  
Sent By mawillia Date 2008-11-17 Time 16:01 Rev Time 0.00
Received By mawillia Date 2008-11-17 Time 15:41 Sent To  
Notes
2008-11-17 16:01:06*****APPROVED*****
  
 PLAN SHEETS A-1 AND A-2 WERE STAMPED, INITIALED, AND
 DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2008-11-07 Cont ID  
Sent By mwennerg Date 2008-11-07 Time 10:02 Rev Time 0.00
Received By mwennerg Date 2008-11-07 Time 10:02 Sent To  
Notes
2008-11-07 10:03:48***DENIED***
  
 THIRD REQUEST
  
  
 1) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE
 SAFETY SHALL COMPLY WITH NFPA 101, 2003. PLEASE ADD TO
 CODE TABULATION.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-10-23 Cont ID  
Sent By mwennerg Date 2008-10-23 Time 15:01 Rev Time 0.00
Received By mwennerg Date 2008-10-23 Time 15:01 Sent To  
Notes
2008-10-23 15:06:29***PROVISO***
  
 1) PLEASE ADD THE FOLLOWING CODES TO THE CODE
 TABULATION. THE PLANS WILL BE STAMPED WHEN RETURNED FOR
 THIS AND OTHER REVIEW COMMENT CORRECTIONS.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-10-01 Cont ID  
Sent By mwennerg Date 2008-10-01 Time 09:39 Rev Time 0.00
Received By mwennerg Date 2008-10-01 Time 09:29 Sent To  
Notes
2008-10-01 09:38:33***DENIED***
  
 1) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE
 SAFETY SHALL COMPLY WITH NFPA 101, 2003. PLEASE ADD TO
 CODE TABULATION.
  
 2) PLEASE ILLUSTRATE THE LOCATIONS OF ILLUMINATED EXIT
 SIGNS AND EMERGENCY LIGHTING FACILITIES. (NEW OR
 EXISTING)
  
 3) PLEASE SHOW LOCATION(S) OF REQUIRED 2A-10B,C RATED
 FIRE EXTINGUISHERS.
  
 4) IF SPACE IS PROTECTED BY AUTOMATIC FIRE SPRINKLER
 SYSTEM, SHOW SPRINKLER HEAD LAYOUT. ADDITIONALLY,
 SEPARATE SHOP DRAWINGS AND PERMIT WILL BE REQUIRED
 PRIOR TO FIRE SPRINKLER REMODEL IF APPLICABLE.
  
 5) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241. PLEASE ADD TO CODE TABULATION.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-12-29 Cont ID  
Sent By adarroug Date 2008-12-29 Time 08:59 Rev Time 0.00
Received By adarroug Date 2008-12-29 Time 08:59 Sent To P
Notes
2008-12-29 09:01:19TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-11-26 Cont ID  
Sent By adarroug Date 2008-11-26 Time 16:32 Rev Time 0.00
Received By adarroug Date 2008-11-26 Time 16:32 Sent To E
Notes
2008-11-26 16:32:32TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-11-10 Cont ID  
Sent By adarroug Date 2008-11-10 Time 16:27 Rev Time 0.00
Received By adarroug Date 2008-11-10 Time 16:27 Sent To  
Notes
2008-11-10 16:27:44TO "BOB"#8

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-10-29 Cont ID  
Sent By adarroug Date 2008-10-29 Time 13:54 Rev Time 0.00
Received By adarroug Date 2008-10-29 Time 13:54 Sent To  
Notes
2008-10-29 13:54:45TO "BOB"#6

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-15 Cont ID  
Sent By adarroug Date 2008-10-15 Time 14:53 Rev Time 0.00
Received By adarroug Date 2008-10-15 Time 14:53 Sent To  
Notes
2008-10-15 14:56:07TO "BOB"#3

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-10-01 Cont ID  
Sent By mperson Date 2008-10-01 Time 10:02 Rev Time 0.00
Received By mperson Date 2008-09-17 Time 14:42 Sent To PC
Notes
2008-09-17 14:45:34TO "BOB"#4

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-10-30 Cont ID  
Sent By tgordon Date 2008-10-30 Time 11:15 Rev Time 0.30
Received By tgordon Date 2008-10-30 Time 11:15 Sent To  
Notes
2008-10-30 11:16:07ONLY MECHANICAL WORK TO BE DONE INSTALL BATHROOM
 EXHAUST FAN.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-10-30 Cont ID  
Sent By tgordon Date 2008-10-22 Time 15:21 Rev Time 0.30
Received By tgordon Date 2008-10-22 Time 15:21 Sent To  
Notes
2008-10-22 15:29:29PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) AS REQUESTED IN LAST REVIEW 9-19-08, SUBMIT
 MECHANICAL (A/C) PLANS FOR REVIEW, SEE 2004 FBC/M
 401.2. (AS THE FLOOR PLAN IS BEING ALTERED AND ROOM
 SIZES CHANGED THE EXISTING SUPPLY AND RETURN GRILL
 LOCATIONS WILL NEED TO BE ALTERED AND AMOUNT OF AIR
 CFM'S TO EACH ROOM. PLEASE SUBMIT MECHANICAL PLAN
 SHOWING NEW REQUIREMENTS OR MECHANICAL PLAN SHOWING THE
 EXISTING LOCATIONS ARE MEETING THE NEW REQUIREMENTS AND
 CODES).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-09-19 Cont ID  
Sent By tgordon Date 2008-09-19 Time 12:16 Rev Time 0.30
Received By tgordon Date 2008-09-19 Time 12:16 Sent To  
Notes
2008-09-19 12:20:12PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) SUBMIT MECHANICAL (A/C) PLANS FOR REVIEW, SEE 2004
 FBC/M 401.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2009-01-06 Cont ID  
Sent By lwagner Date 2009-01-06 Time 14:28 Rev Time 0.00
Received By lwagner Date 2009-01-06 Time 13:56 Sent To  
Notes
2009-01-06 13:57:13REVISION OK LEW

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-11-12 Cont ID  
Sent By mperson Date 2008-11-12 Time 15:54 Rev Time 0.30
Received By mperson Date 2008-11-12 Time 15:54 Sent To  
Notes
2008-12-29 09:00:25TO "P" BOX/REV

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-11-04 Cont ID  
Sent By mperson Date 2008-11-04 Time 16:40 Rev Time 0.30
Received By mperson Date 2008-11-04 Time 16:40 Sent To  
Notes
2008-11-04 16:44:16PLUMBING PLAN REVIEW:
 DENIED 2ND TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 **THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND
 WITH THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS
 THE DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. THE VALUE ON THE PERMIT APPLICATION APPEARS LOW. THE
 VALUE ON THE PERMIT APPLICATION MUST INCLUDE THE TOTAL
 COST OF LABOR, MATERIALS AND DESIGN (WHICH NOW INCLUDES
 A NEW BATHROOM).
 PER (W.P.B AS AMENDED) SECTION 108.3 BUILDING PERMIT
 VALUATION. IF, IN THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF BUILDING, ALTERATION,
 STRUCTURAL, ELECTRICAL, GAS, MECHANICAL OR PLUMBING
 SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED.
  
 **NO COMMENT RESPONSE AND THE VALUE HAS NOT BEEN
 INCREASED BY THE CONTRACTOR. VALUE IS TO LOW FOR THE
 AMOUNT OF WORK BEING DONE.
  
 2. "OK" COMMENT ADDRESSED.
  
 3. "OK" COMMENT ADDRESSED.
  
 4. "OK" COMMENT ADDRESSED.
  
 5. "OK" COMMENT ADDRESSED.
  
 6. "OK" COMMENT ADDRESSED.
  
 7. "OK" COMMENT ADDRESSED.
  
 8. "OK" COMMENT ADDRESSED.
  
 END OF COMMENTS:
  
 *PLEASE CALL IF THERE ARE ANY QUESTIONS.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-10-17 Cont ID  
Sent By mperson Date 2008-10-17 Time 13:10 Rev Time 1.00
Received By mperson Date 2008-10-17 Time 13:10 Sent To  
Notes
2008-10-17 14:35:02PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THE VALUE ON THE PERMIT APPLICATION APPEARS LOW. THE
 VALUE ON THE PERMIT APPLICATION MUST INCLUDE THE TOTAL
 COST OF LABOR, MATERIALS AND DESIGN (WHICH NOW INCLUDES
 A NEW BATHROOM).
 PER (W.P.B AS AMENDED) SECTION 108.3 BUILDING PERMIT
 VALUATION. IF, IN THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF BUILDING, ALTERATION,
 STRUCTURAL, ELECTRICAL, GAS, MECHANICAL OR PLUMBING
 SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED.
  
 2. SHEET A-1 "GENERAL BUILDING CODE ANALISIS" THE
 "PLUMBING FIXTURE REQUIREMENTS" MINIMUM FIXTURE
 REQUIREMENTS PER TABLE 403.1 INDICATED ON THE PLAN
 SHEET IS WRONG FOR A BUSSINESS OCCUPANCY. PLEASE
 CORRECT MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
 FOR A BUSSINESS OCCUPANCY PER FBC-2004 PLUMBING TABLE
 403.1 TO BE THE FOLLOWING.
  
 WATER CLOSETS, MALE/FEMALE = 1 PER 25 FOR THE FIRST 50
 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50.
  
 LAVATORIES, MALE/FEMALE = 1 PER 40 FOR THE FIRST 50 AND
 1 PER 80 FOR THE REMAINDER EXCEEDING 50.
  
 DRINKING FOUNTAINS = 1 PER 100.
  
 3. SHEET A-1 PROPOSED FLOOR PLAN DOES NOT CLEARLY
 INDICATE THE REQUIERED DRINKING FOUNTAIN FOR A
 BUSSINESS OCCUPANCY. PER FBC-2004 PLUMBING TABLE 403.1
 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES FOR A
 BUSSINESS OCCUPANCY IS 1 PER 100 AND IT SHALL BE
 ACCESSIBLE PER THE FOLLOWING FBC-2004 CHAPTER 11,
 FLORIDA ACCESSIBILITY CODE SECTIONS.
  
 **SECTION 11-4.15 DRINKING FOUNTAINS AND WATER COOLERS
 (ELEVATION DETAIL REQUIRED WITH THE FOLLOWING
 INFORMATION)
  
 SECTION 11-4.15.2 SPOUT HEIGHT. SPOUT HEIGHT 36" TO
 OUTLET MAXIMUM.
  
 SECTION 11-4.15.3 SPOUT LOCATION. FRONT OF UNIT, WATER
 FLOW IN TRAJECTORY THAT IS PARALLEL OR NEARLY PARALLEL
 TO FRONT OF THE UNIT, WATER FLOW MINIMUM OF 4" HIGH. ON
 AN ACCESSIBLE OVAL OR ROUND BOWL FLOW OF WATER IS
 WITHIN 3" OF THE FRONT OF FOUNTAIN.
  
 SECTION 11-4.15.4 CONTROLS. SHALL BE FRONT MOUNTED OR
 SIDE MOUNTED NEAR FRONT EDGE.
  
 SECTION 11-4.15.5 CLEARANCES. KNEE 27" HIGH, & 30" X
 48" FLOOR SPACE.
  
 SECTION 11-4.1.3(10)(A) WHERE ONLY ONE DRINKING
 FOUNTAIN IS PROVIDED ON A FLOOR, THERE SHALL BE A
 DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO INDIVIDUALS
 WHO USE WHEELCHAIRS IN ACCORDANCE WITH SECTION 11-4.15
 AND ONE ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING
 OR STOOPING.(THIS CAN BE ACCOMMODATED BY THE USE OF A
 HI-LO FOUNTAIN OR BY SUCH OTHER MEANS AS WOULD ACHIEVE
 THE REQUIRED ACCESSIBILITY FOR EACH GROUP ON EACH
 FLOOR).
  
 4. SHEET A-1 PROPOSED FLOOR PLAN IS INDICATING A NEW
 BATHROOM. PLEASE PROVIDE THE FOLLOWING FBC-2004 CHAPTER
 11, FLORIDA ACCESSIBILITY CODE REQUIREMENTS FOR THE
 WATER CLOSET PER THE FOLLOWING CODE SECTIONS.
  
 **SECTION 11-4.16 WATER CLOSETS (ELEVATION DETAIL
 REQUIRED WITH THE FOLLOWING INFORMATION)
  
 SECTION 11-4.16.2 CLEAR FLOOR SPACE. (SEE FIGURE 28,
 18" SIDE- 36" MIN. TOTAL.
  
 SECTION 11-4.16.3 HEIGHT. 17" TO 19".
  
 SECTION 11-4.16.5 FLUSH CONTROLS. MOUNTED ON WIDE SIDE
 MAX. 44" HIGH.
  
 5. SHEET A-1 PROPOSED FLOOR PLAN DOES NOT CLEARLY
 INDICATE THE SINK NEXT TO THE NEW BATHROOM AS EXISTING
 OR PROPOSED NEW. PLEASE CLARIFY THIS ON THE RESUBMITTAL
 (PER FBC-2004 CHAPTER 1, W.P.B. AS AMENDED SECTION
 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS) AND
 PLEASE KNOW THAT IF THIS IS A NEW PROPOSED BREAK ROOM
 SINK THAT IT SHALL BE ACCESSIBLE PER THE FBC-2004
 CHAPTER 11, FLORIDA ACCESSIBILITY CODE SECTIONS.
  
 ** SECTION 11-4.24 SINKS (ELEVATION DETAIL REQUIRED
 WITH THE FOLLOWING INFORMATION)
  
 SECTION 11-4.24.2 HEIGHT. MAXIMUM 34" A.F.F. TO RIM OR
 COUNTER.
  
 SECTION 11-4.24.3 KNEE CLEARANCE. MINIMUM 27" HIGH, 30"
 WIDE, AND 19" DEEP.
  
 SECTION 11-4.24.4 DEPTH. MAXIMUM 6-1/2" DEEP.
  
 SECTION 11-4.24.5 CLEAR FLOOR SPACE. 30" X 48" AND
 CLEAR FLOOR SPACE SHALL EXTEND A MAXIMUM OF 19"
 UNDERNEATH THE SINK.
  
 SECTION 11-4.24.6 EXPOSED PIPES AND SURFACES. INSULATE
 TO PROTECT AGAINST CONTACT.
  
 SECTION 11-4.24.7 FAUCETS. LEVER-OPERATED, PUSH-TYPE,
 OR ELECTRONICALLY CONTROLLED ARE ACCEPTABLE DESIGNS.
  
 6. SHEET A-2 SANITARY PLUMBING RISER IS INDICATING A
 "SV" FOR THE VENT. PLEASE CLARIFY IF THIS IS AN AIR
 ADMITTANCE VALVE (A.A.V.) AS NO LEGEND WAS PROVIDED.
 PER FBC-2004 PLUMBING SECTION 901.1 SCOPE.
  
 7. NOTE: IF "SV" IS AN AIR ADMITTANCE VALVE CLEARLY
 INDICATE ON THE RESUBMITTED PLANS HOW MANY FLOORS THE
 BUILDING HAS AND HOW MANY FLOORS ARE LOCATED ABOVE THE
 AIR ADMITTANCE VALVE. PLEASE KNOW THAT PER FBC-2004
 PLUMBING SECTION 917.3.1 LOCATION OF BRANCH. THE
 HORIZONTAL BRANCH DRAIN SHALL CONNECT TO THE DRAINAGE
 STACK OR BUILDING DRAIN A MAXIMUM OF FOUR BRANCH
 INTERVALS FROM THE TOP OF THE STACK. WHICH MEANS THAT
 THERE CAN ONLY BE FOUR FLOORS ABOVE THE PROPOSED AIR
 ADMITTANCE VALVE FOR THE NEW BATHROOM.
  
 8. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.1.3,
 PLUMBING (3), (5), (8), (10), AND (13): AN ISOMETRIC
 POTABLE WATER RISER DIAGRAM IS REQUIRED FOR THE
 PROPOSED WORK FOR BOTH THE HOT AND COLD WATER
 INDICATING THE PIPE SIZES, VALVE LOCATIONS, LOCATION OF
 THE WATER SUPPLY LINE WITH BACKFLOW PREVENTER **608,
 THERMAL EXPANSION CONTROL FOR THE WATER HEATER (IF
 APPLICABLE) **607.3, AND LOCATION OF THE WATER-HAMMER
 ARRESTORS (IF APPLICABLE) WHERE QUICK CLOSING VALVES
 ARE UTILIZED (EXAMPLES=WASHING MACHINES, DISHWASHERS,
 ICE MAKERS) **604.9.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2008-10-01 Cont ID  
Sent By mperson Date 2008-10-01 Time 09:57 Rev Time 0.15
Received By mperson Date 2008-10-01 Time 09:57 Sent To I
Notes
2008-10-01 10:02:19NOTE: THERE IS NO PLUMBING WORK ON PLANS AND NO
 PLUMBING PERMIT APPLIED FOR AT THIS TIME. *MRPERSON.

Review Stop Z ZONING
Rev No 1 Status N Date 2008-09-30 Cont ID  
Sent By aaponte Date 2008-09-30 Time 11:44 Rev Time 0.00
Received By aaponte Date 2008-09-30 Time 11:44 Sent To  
Notes
***NONE***