Plan Review Stops For Permit 08090106 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2009-03-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-03-13 |
Time |
15:08 |
Rev Time |
0.22 |
Received By |
jwitmer |
Date |
2009-03-13 |
Time |
15:08 |
Sent To |
PC |
|
Notes |
2009-03-13 15:09:31 | LETTER OF CLARIFICATION DATED 2-23-09 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-01-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-01-21 |
Time |
10:54 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2009-01-21 |
Time |
10:54 |
Sent To |
|
|
Notes |
2009-01-21 10:54:56 | REVISION# 2 DATED 12/24/08 SHEET A3.1- OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-10-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-10-24 |
Time |
14:23 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2008-10-24 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-09-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-09-12 |
Time |
11:12 |
Rev Time |
1.66 |
Received By |
jwitmer |
Date |
2008-09-12 |
Time |
11:12 |
Sent To |
|
|
Notes |
2008-09-12 12:03:26 | BUILDING PLAN REVIEW | | PERMIT: 08090106 | | ADD: 2090 PALM BEACH LAKES #1000 | | CONT: S .O. ENTERPRISES | | TEL: (561)827-6508 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | SEPT.12,2008 | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 1B) I INFORMATIONAL FL S S 713.13 NOTICE OF | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | INSPECTION. | | | | 2) NOTE LS.1 EXTRIOR VERTICAL EXITS INDICATE A 1 HR | | EXIT ENCLOSURE PLEASE SEE 1019.1 EXIT ENCLOSURES OVER 4 | | STORIES ARE TO BE 2HR RATED. THIS PERMIT IS FOR A | | INTERIOR FIT UP AND THE EXTERIOR STIARWAYS ARE NOT | | EFFECTED, EITHER CORRECT THE NOTE OR REMOVE IT FROM THE | | PLANS. | | | | 3) SHEET A3.1 DETAILS A & B INDICATE WOOD SUB-BUCKS, | | PLEASE ALLOWABLE COMBUSTABLES IN TYPE I TYPE II | | BUILDINGS. 603.1(1). | | | | 4) LS AND A1.1 BOTH INDICATE DOOR 101 A SET OF DOUBLE | | DOORS PARTIALLY BLOCKING DOOR 100 EGRESS. 1008.1.1 THIS | | CODE SECTION REQUIRES A CLEAR 32" WHEN OPENED AT A 90 | | DEGREE ANGLE. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2009-02-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-02-10 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-02-10 |
Time |
10:46 |
Sent To |
PC |
|
Notes |
2009-02-10 10:46:12 | ** PROVISO/REDLINED PLANS** | | | | 1) NOTE: THE INSTALLATION OF RODS INSTALLED TO CONCRETE | | DECK ABOVE BY USE OF EPOXY AS NOTED ON PLANS NEEDS TO | | BE VERIFIED BY STRUCTURAL ENGINEER. THE METHOD, TYPE | | AND INSTALLATION PROCESS IS NOT SPECIFIED THEREFORE | | THIS NEEDS TO BE VERIFIED. | | THE STRUCTURAL INTEGRITY FOR THE INSTALLATION OF THIS | | TRANSFORMER IS IMPERATIVE FOR THE TENSION LOAD. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2009-01-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-01-15 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-01-15 |
Time |
15:53 |
Sent To |
|
|
Notes |
2009-01-15 15:53:57 | ** DENIED REVIEW OF REVISIONS** | | | | | | 1) NOTE: THERE ARE A FEW ITEMS REDLINE DON PREVIOUS | | PLANS WHICH STILL NEED TO BE COORDINATED. | | THE PLANS STILL SHOW A TRANSFORMER IN FRONT OF THE | | PANELS. PLEASE VERIFY WHETHER OR NOT THE TRANSFORMER IS | | ABOVE PANELS GIVEN THE CLEARANCES PER 110.26 | | PLEASE COORDINATE RISER AS BOTH PANELS ARE SHOWN AS | | 125AMP MCB AND MLO ON EACH OF THE SCHEDULES YET THE | | RISER SHOWS BOTH OF THESE AS 225AMP MCB AND MLO. | | NEED TO VERIFY 240.21,310.16,240.4 | | THE NEW RECEPTACLES NEED TO BE SPECIFIC. THESE ARE | | NOTED ONLY AS RECEPTACLES. ALSO THE NEW 2-POLE | | RECEPTACLES NEED TO NOTED FOR WHAT THEY WILL SERVE. | | 408.4 | | | | FBC 106.1.1, 106.1.2 FOR ADDITIONAL INFORMATION, | | CLARITY AND COORDINATION. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | | | | | *** NOTED: THERE IS NO NEW LIGHTING PERMITTED EXCEPT IN | | ELEVATOR LOBBY AREA. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-10-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-10-31 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-10-31 |
Time |
10:23 |
Sent To |
|
|
Notes |
2008-10-31 10:25:36 | NO NEW LIGHTING EXCEPT THE ELEVATOR LOBBY. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-09-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-09-12 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-09-12 |
Time |
12:04 |
Sent To |
|
|
Notes |
2008-09-12 12:04:50 | ** DENIED REVIEW ** | | | | | | | | | | 1) NOTE: PLEASE SEE THE ELECTRICAL EQUIPMENT IN CLOSET | | AREA DOES NOT MEET 110.26,408.17, 240.24. THIS IS SHOWN | | AS EXISTING HOWEVER BASED ON THIS BEING A LIFE SAFETY | | AND FIRE HAZARD, EQUIPMENT AND SPACE LOCATION/LAYOUT | | NEEDS TO CHANGE. | | | | 2) NOTE: PLEASE SUBMIT LIGHTING PERFORMANCE | | CALCULATIONS PER 13-415.2, 13-415.2.ABC.2.1, 2.2. | | | | | | 3) NOTE: LIGHTING CONTROLS FOR NEW BEING INSTALLED NEED | | TO MEET 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | | 4) NOTE: PANEL SCHEDULE FOR NEW CIRCUITS NEED TO BE | | SPECIFIC TO ROOMS AND AREAS IN WHICH THEY FEED. | | | | 5) NOTE: PLEASE PLACE NOTE ON PLANS FOR SERVER ROOM | | THAT WIRING METHODS IN NEC 645 ARE NOT PERMITTED. | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-01-21 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2009-01-21 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2009-01-21 |
Time |
15:48 |
Sent To |
|
|
Notes |
2009-01-21 15:48:54 | REVISION #2 DATED 12/24/08 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2008-10-30 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-30 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-10-30 |
Time |
14:30 |
Sent To |
|
|
Notes |
2008-10-30 14:30:50 | SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | SPRINKLER AND FIRE ALARM REMODEL. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-10-01 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-01 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-10-01 |
Time |
13:59 |
Sent To |
|
|
Notes |
2008-10-01 15:27:02 | ***DENIED*** | | | | 1) MORE EXIT SIGNS AND EMERGENCY LIGHTING NEEDED IN | | OPEN WORK AREA 107. | | | | 2) CONSTRUCTION, ALTERATION AND DEMOLITION SHALL COMPLY | | WITH NFPA 241. | | | | 3) DOOR SCHEDULE REFERENCES THE INCORRECT CODE EDITION. | | LOCKING ARRANGEMENTS SHALL COMPLY WITH 101, SEC. | | 7.2.1.5. | | | | 4) RATED DOORS SHALL BE PROVIDED WITH UL LISTED | | CLOSERS. | | | | 5) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | SPRINKLER AND FIRE ALARM REMODEL. | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-02-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-25 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-25 |
Time |
16:41 |
Sent To |
B |
|
Notes |
2009-02-25 16:42:06 | TO "JWITMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-02-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-09 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-09 |
Time |
10:30 |
Sent To |
E |
|
Notes |
2009-02-09 10:31:17 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-01-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-06 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-06 |
Time |
16:24 |
Sent To |
|
|
Notes |
2009-01-06 16:25:18 | TO "COMM" BD#48 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-10-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-16 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-16 |
Time |
14:03 |
Sent To |
|
|
Notes |
2008-10-17 10:24:54 | TO "COMM" BD#20 | 2008-10-16 14:04:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-10-01 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-01 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-09-05 |
Time |
11:32 |
Sent To |
|
|
Notes |
2008-09-05 11:34:18 | TO "COMM" BD#23 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2009-02-01 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-02-01 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-02-01 |
Time |
15:12 |
Sent To |
PC |
|
Notes |
2009-02-01 15:12:42 | REVISED M2.1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-11-02 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-11-02 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-11-02 |
Time |
14:50 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-09-11 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-09-11 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-09-10 |
Time |
16:37 |
Sent To |
|
|
Notes |
2008-09-11 10:18:46 | REVIEW #: 1ST | | ACTION: DENIED | | | | THE FOLLOWING COMMENTS HAVE BEEN GENERATED BASED ON THE | | REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS UNDER | | THESE CODES: | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. IN ACCORDANCE WITH THE REQUIREMENTS FOR A LEVEL 2 | | ALTERATION, AS DECLARED ON PAGE LS.1, ALL RECONFIGURED | | SPACES INTENDED FOR OCCUPANCY IN ANY WORK AREA SHALL BE | | PROVIDED WITH NATURAL OR MECHANICAL VENTILATION OR | | EXHAUST IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, | | MECHANICAL. SEE FBCEB 609.1. PROVIDE SPACE BY SPACE | | VENTILATION CALCULATIONS WITH OCCUPANCY CLASSIFICATION, | | OCCUPANT LOAD, VENTILATION REQUIRED AND VENTILATION | | PROVIDED IN ACCORDANCE WITH FBCM TABLE 403.3 OR SECTION | | 403.4. THE METHOD OF VENTILATION SHALL BE DECLARED ON | | THE PLANS. | | | | 2. PROVIDE DESIGN CFM ON THE PLANS FOR ALL AIR | | DISTRIBUTION DEVICES TO FACILITATE A TEST AND BALANCE | | OF THE SYSTEMS IN ACCORDANCE WITH FBCB | | 13-410.1.ABC.4.1. THIS IS ALSO NECESSARY TO CONFIRM | | VENTILATION RATES AS REQUIRED IN COMMENT #1 ABOVE AND | | TO SATISFY SPECIFICATIONS SECTION 15990 ON PAGE M0.1. | | | | 3. FIRE DAMPERS LOCATED WITHIN AIR DISTRIBUTION SYSTEMS | | SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS | | OF THE MANUFACTURER?S INSTALLATION INSTRUCTIONS AND | | LISTING IN ACCORDANCE WITH FBCM 607.2. MANUFACTURER?S | | INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON THE JOB | | SITE AT THE TIME OF INSPECTION IN ACCORDANCE WITH THIS | | SECTION AND FBCM 304.1. | | | | 4. A MINIMUM OF TWO SETS OF PLANS SHALL BE SUBMITTED | | FOR REVIEW IN ACCORDANCE WITH FBCB 106.1. | | | | PLEASE RESPOND TO EACH COMMENT IN WRITING TO ASSIST IN | | FACILITATING A TIMELY REVIEW. PROVIDE A DESCRIPTION OF | | HOW EACH COMMENT WAS ADDRESSED AS WELL AS WHERE THE | | REQUESTED INFORMATION CAN BE FOUND. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-01-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-01-30 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-01-30 |
Time |
14:14 |
Sent To |
|
|
Notes |
2009-01-30 14:14:57 | REVISION OK -- SHT P2.1. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-10-29 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-10-29 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-10-29 |
Time |
14:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-09-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-09-08 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-09-08 |
Time |
12:44 |
Sent To |
|
|
Notes |
2008-09-09 07:40:16 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | 1. MINIMUM 2 SETS OF PLANS REQUIRED FOR REVIEW. SECTION | | 106.1. | | | | 2. SHT P2.1 PLUMBING FIXTURE SCHEDULE INDICATES THE | | SINK TO BE AN ELKAY MODEL DLH222210C. THIS DOES NOT | | COMPLY WITH SECTION 11-4.24.4 SINK DEPTH TO BE MAXIMUM | | 6-1/2" DEEP. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|