Plan Review Stops For Permit 08090099 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-10-20 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-10-20 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-10-20 |
Time |
15:48 |
Sent To |
PC |
|
Notes |
2008-10-20 15:47:09 | PROCESS PLANS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-10-15 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-10-15 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-10-15 |
Time |
10:59 |
Sent To |
|
|
Notes |
2008-10-15 10:55:51 | PROVISOR: | | IF DOOR #1 IS A NEW EXTERIOR DOOR, SUBMIT THE PRODUCT | | APPROVALS FOR THAT DOOR. 106.3.3* |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-09-12 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-09-12 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-09-12 |
Time |
06:58 |
Sent To |
PC |
|
Notes |
2008-09-12 09:00:07 | 9-12-08 | | BUILDING PLAN REVIEW | | PERMIT: 08090099 | | ADD: 5601 CORPORATE WAY #119-120 | | CONT: S.O. ENTERPRISES INC. | | TEL: (561)827-6508 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 1ST | | ACTION: DENIED | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. THE PLANS MAKE | | REFERENCE TO THE BROWARD COUNTY CODE EDITION AND THE | | 1997 ACCESSIBILITY CODE; THESE REFERENCES ARE NOT | | CORRECT. | | | | 3) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | THIS CODE. | | | | 4) FBC 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED. THE NEW OFFICES ARE MISSING SOME | | DIMENSIONS ON THE DRAWINGS. PROVIDE A WINDOW BUCK | | DETAIL FOR THE FOUR GLASS WINDOWS SHOWN ON THE PLANS | | AND INDICATE HOW THE FRAME WILL BE ATTACHED TO THE BUCK | | AND STATE THE TYPE OF GLAZING TO BE INSTALLED. PLEASE | | MAKE SURE THE LEGEND SYMBOLS MATCH THE WALL TYPES | | INDICATED ON THE FLOOR PLANS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-10-17 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-17 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-09-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-09-11 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-09-11 |
Time |
16:57 |
Sent To |
|
|
Notes |
2008-09-11 16:58:06 | | | ** DENIED REVIEW ** | | | | | | | | 1) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE STATED | | ON ELECTRICAL PLANS. | | 2004 FBC W/ 2007 REVISIONS | | 2004 RESIDENTIAL CODE | | 2005 NFPA-70 | | 2003 NFPA-101 | | 2002 NFPA-72 | | | | ** PLANS SHOW CODES SUCH AS A 2001 EDITION OF NFPA-101 | | (LIFE SAFETY CODE) HOWEVER THERE WAS NEVER A 2001 | | EDITION OF NFPA_101. | | ** PLANS SHOW REFERENCE TO BROWARD COUNTY | | ** PLANS SHOW OTHERS SUCH A 1997 FLORIDA ACCESSIBILITY | | CODE | | | | 2) NOTE: PLEASE SEE 13-415.1.ABC.1.1,.1.2 AND .1.3 FOR | | REQUIRED LIGHTING CONTROLS FOR NEW BEING INSTALLED. | | NO DESIGN FOR CHAPTER 13 IS SHOWN. | | | | 3) NOTE: PLEASE SUBMIT LIGHTING PERFORMANCE | | CALCULATIONS PER 13-415.2,13-415.2.ABC.1.1, .1.2. SEE | | TABLES. | | | | 4) NOTE: PLEASE COMPLETE SIGN CIRCUITS, LOADS AND | | LOCATIONS PER 600.5. (IF APPLICABLE) | | | | 5) NOTE: PLEASE BE SURE TO COMPLETE FIXTURE LEGEND FOR | | SPECIFIC FIXTURES FOR COMPLIANCE AND VERIFICATION WITH | | NOTED #3 ABOVE. | | | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2008-10-20 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-10-20 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-10-20 |
Time |
12:27 |
Sent To |
B1 |
|
Notes |
2008-10-20 12:36:31 | *****APPROVED***** | | | | | | PLAN SHEETS A-3 AND E-2 WERE STAMPED, INITIALED, AND | | DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-09-11 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-09-11 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-09-11 |
Time |
15:00 |
Sent To |
|
|
Notes |
2008-09-11 15:10:12 | ***DENIED*** | | | | 1) LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003. PLEASE | | CORRECT CODE EDITION ON SHEET A-1. | | | | 2) SHEET A-1 INDICATES THAT PROJECT IS NOT PROTECTED BY | | AUTOMATIC FIRE SPRINKLER SYSTEM. DELETE FIRE SPRINKLER | | REFERENCE ON SHEET M-1 NOTE #3. | | | | 3) PROVIDE MINIMUM INTERIOR FINISH CLASSIFICATION FOR | | WALLS AND CEILING. | | | | 4) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | WITH NFPA 241. | | | | 5) ADDITIONAL EXIT SIGN MAY BE REQUIRED IN HALLWAY. | | | | ALTHOUGH NOT REQUIRED, A RESPONSE LETTER INDICATING HOW | | AND WHERE ON THE PLANS EACH COMMENT WAS ADDRESSED WOULD | | HELP EXPEDITE THE PLAN REVIEW PROCESS. | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-11-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-13 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-13 |
Time |
10:47 |
Sent To |
M |
|
Notes |
2008-11-13 10:47:56 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-10-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-07 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-07 |
Time |
14:46 |
Sent To |
|
|
Notes |
2008-10-07 14:48:37 | TO "BOB"#1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2008-09-12 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-05 |
Time |
11:45 |
Sent To |
|
|
Notes |
2008-09-05 11:47:15 | TO "BOB"#17 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2008-11-13 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-11-13 |
Time |
14:08 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-11-13 |
Time |
14:07 |
Sent To |
|
|
Notes |
2008-11-13 14:08:33 | REVISION TO MECH. PLAN M-1. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-10-08 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-10-08 |
Time |
16:35 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-10-08 |
Time |
16:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-09-10 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-09-10 |
Time |
08:15 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-09-10 |
Time |
08:15 |
Sent To |
|
|
Notes |
2008-09-10 08:29:48 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | | | 1) PLAN A-1 CODE INFORMATION STATES "FLORIDA BUILDING | | CODE 2004 BROWARD COUNTY EDITION". THE STATE OF FLORIDA | | AND THE CITY OF W .P. B. IS UNDER THE 2004 FLORIDA | | BUILDING CODE WITH 2007 REVISIONS. PLEASE CORRECT PER | | 2004 W.P.B. AMEND. 101.4. | | | | 2) PLAN M-1, PLEASE SHOW THE CFM'S AT ALL NEW SUPPLY | | AIR GRILLS, PER 2004 FBC 13-410.1.ABC.4.3. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-09-10 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-09-10 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-09-10 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|