Plan Review Stops For Permit 08080345 |
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-15 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-15 |
Time |
11:50 |
Sent To |
I |
|
Notes |
2008-08-15 11:54:04 | ****************PROVISO**************** | | A} IF DRYER ROOM IS A CONFINED SPACE, OPENINGS | | REQUIRED PER SECTION 304.5 OR SECTION 304.6 SHALL BE | | INSTALLED. MINIMUM 1,000 CUBIC FEET REQUIRED. | | | | B}IF WATER HEATER ROOM IS A CONFINED SPACE, OPENINGS | | REQUIRED PER SECTION 304.5 OR SECTION 304.6 SHALL BE | | INSTALLED. MINIMUM 3,750 CUBIC FEET REQUIRED. | | | | C} PER FBC-2004 FUEL GAS, SECTION 409.4 MP REGULATOR | | VALVES: A LISTED SHUTOFF VALVE SHALL BE INSTALLED | | IMMEDIATELY AHEAD OF EACH MP REGULATOR. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-15 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-14 |
Time |
16:15 |
Sent To |
PC |
|
Notes |
2008-08-14 16:15:27 | TO "G" BOX |
|
|
|