Plan Review Details - Permit 08080310
Plan Review Stops For Permit 08080310
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-26 Cont ID  
Sent By shill Date 2008-08-26 Time 17:34 Rev Time 0.00
Received By shill Date 2008-08-26 Time 17:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-08-25 Cont ID  
Sent By shill Date 2008-08-25 Time 15:41 Rev Time 0.00
Received By shill Date 2008-08-25 Time 15:41 Sent To  
Notes
2008-08-25 16:20:50****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.CONCRETE BLOCK SUBSTRATE SPECIFIED ON THE
 INSTALLATION SCHEDULE.MOUNTING TYPE I REQURES A
 CONCRETE SUBSTRATE.
  
 THIS WAS REVISED FOR CONNECTION TYPE "A", BUT NOT "I".
 SEE PAGE 15 OF PRODUCT APPROVAL. PLEASE CHECK ALL.
 FBC16.
  
 2. THE FIRST TWO PAGES OF A MIAMIDADE NOA WAS SUBMITTED
 AS WELL AS THE FLOIRIDA STATE PRODUCT APPROVAL.THE
 SHUTTER GLASS SEPARATION SPECIFIED ON THE INSTALLATION
 SCHEDULE IS NOT COMPLIANT FOR THE NOA.PLEASE EITHER
 REVISE THE INSTALLATION SCHEDULE AND SUBMIT THE
 COMPLETE NOA, OR REMOVE THE NOA FROM THE PACKAGE.YOU
 CANNOT SUBMIT THIS TO BE A PART OF THE PERMIT PACKAGE
 IF YOU DO NOT WISH TO COMPLY WITH THE INSTALLATION
 REQUIREMENTS OF THE NOA.
  
 3.INFORMATIONAL ONLY - THE INFORMATION HIGHLIGHTED ON
 THE PRODUCT APPROVAL WAS FOR ALL POINTS SOLID SET
 RATHER THAN TAPCONS, SEE THE TOP LEFT CORNER OF PAGE
 13.THIS WOULD HAVE REQUIRED DIFFERENT ANCHOR SPACING,
 BUT AS THE CONTRACTOR HAD USED THE 75PSF COLUMN (RATHER
 THAN 40PSF), THE ANCHOR SPACING ON THE INSTALLATION
 SCHEDULE MEETS THE MINIMUM REQUIRED BY CODE.HOWEVER,
 I AM BRINGING THIS TO YOUR ATTENTION TO AVOID FUTURE
 ISSUES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-08-20 Cont ID  
Sent By shill Date 2008-08-20 Time 10:27 Rev Time 0.00
Received By shill Date 2008-08-20 Time 10:27 Sent To  
Notes
2008-08-20 10:27:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.CONCRETE BLOCK SUBSTRATE SPECIFIED ON THE
 INSTALLATION SCHEDULE.MOUNTING TYPE A REQURES A
 CONCRETE SUBSTRATE.
  
 2.AN EDGE DISTANCE OF LESS THAN 3 1/2" REQUIRES A
 FACTOR APPLIED TO THE ANCHOR SPACING, SEE PAGE 14 OF
 THE PRODUCT APPROVAL.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-08-21 Cont ID  
Sent By adarroug Date 2008-08-21 Time 12:48 Rev Time 0.00
Received By adarroug Date 2008-08-21 Time 12:48 Sent To B
Notes
2008-08-21 12:48:19TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-08-20 Cont ID  
Sent By shill Date 2008-08-20 Time 10:27 Rev Time 0.00
Received By shill Date 2008-08-20 Time 10:27 Sent To  
Notes
***NONE***