Plan Review Stops For Permit 08080212 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2009-07-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2009-07-06 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2009-07-06 |
Time |
09:51 |
Sent To |
|
|
Notes |
2009-07-06 09:51:47 | REVISED ENERGY CALCS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-10-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-10-16 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-10-16 |
Time |
10:25 |
Sent To |
PC |
|
Notes |
2008-10-16 10:38:40 | DRAWINGS SUBMITTED WITH PALM BEACH COUNTY IMPACT FEES | | STAMP AND COPY OF PAID RECEIPT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
|
Date |
2008-09-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-09-30 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-09-30 |
Time |
16:27 |
Sent To |
PC |
|
Notes |
2008-09-30 16:37:37 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- RESUBMIT THE ENERGY CALCULATIONS. | | A) NEED TO USE REVISED FORM 600A-2004 R. | | B) CEILING FAN CREDIT CAN'T BE TAKEN. CEILING FAN IS ON | | THE LOGGIA WHICH IS A NON/AC AREA. | | C) COMPLETE INFORMATION ON TOP OF FORM. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-08-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-08-21 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-08-20 |
Time |
07:47 |
Sent To |
PC |
|
Notes |
2008-08-21 17:30:28 | RESIDENTIAL (R3) ADDITION AND RENOVATION BUILDING | | REVIEW CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- BRING PLANS TO PALM BEACH COUNTYTO VERIFY IF | | IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY | | OF PAID RECEIPT IF FEES ARE DUE. | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | 13-101.2.2 FBC 2004. | | NOTE: PLEASE MAKE SURE CORRECT REVISED FORM IS USED | | AND IS FILLED COMPLETELY TO AVOID UNNECESSARY DELAYS. | | | | 3-PLANS TO SPECIFY SAFETY GLASS FOR WINDOWS BY | | BREAKFAST AREA AND BY SHOWER AREA AS REQUIRED BY SEC. | | R308.4 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | A)FIXED ARCHED WINDOW. SEE PLANS. | | | | B) WINDOW MULLION. SEEPLANS. | | | | C) SINGLE HUNG WINDOWS. NEED TO PROVIDE PRODUCT | | APPROVAL THAT MEETS ALL THE DESIGN PRESSURES CALCULATED | | FOR WINDOW W2. | | | | D) FLAT ROOF: | | (1) SPECIFYSPECIFIC APPROVED ASSEMBLY TO BE USED. | | | | (2) SPECIFY SPECIFIC BASE SHEET FASTENING OPTION TO | | BE USED. | | (3) PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING | | AT PERIMETER &CORNER AREAS AS REQ'D BY GENERAL | | LIMITATION #7 ONNOA 07-0111.03. | | | | 5- SHEET SP-1:DESIGN CRITERIA CALLS FOR EXPOSURE "C", | | WHILE STRUCTURAL SHEETSS-1 AND S-3 CALL FOR EXPOSURE | | "B". REVISE AS REQUIRED TO MATCH. | | | | 6- SHEET A-1: | | A) CRAWL SPACE VENTILATION TO COMPLY WITH THE | | MINIMUM SIZE,LOCATION AND ACCESS REQUIREMENTS OF SEC. | | R408 OF 2004 FLORIDA RESIDENTIAL CODE. REVISE AS | | REQUIRED. | | NOTE:REVISE EXTERIOR ELEVATIONS TO REFLECT LOCATION | | OF VENTS AS WELL. | | | | B) REVISE UNDER FLOOR VENTILATION NOTES:REFERENCE | | CODE SECTIONSFROM THE FLORIDA RESIDENTIAL CODE, NOT | | FROM THEFBC. | | | | C) REVISE RISER TREAD RATIO TO COMPLY WITH SEC. | | R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE. | | NOTE: REVISE THIS INFORMATION ON STRUCTURAL DRAWINGS | | ALSO. | | | | 7- SHEET A-2: | | A) EMERGENCY ROOF DRAIN SCUPPERS TO COMPLY WITH | | SEC. R903.4.1 OF 2004 FLORIDA RESIDENTIAL CODE. SPECIFY | | HEIGHT FROM THE FINISHED ROOF COVERING. | | | | B) REVISE ROOF DRAINAGE NOTES:REFERENCE CODE | | SECTIONSFROM THE 2004 FLORIDA RESIDENTIAL CODE, NOT | | THE 2004 FBC. | | | | 8- SHEET A-4: | | A) TYPICAL WALL SECTION: | | (1) CLARIFY WHYVENTING IS NOT REQUIRED. SPECIFY | | WHICH CODE SECTIONS STATES THAT NO VENTILATION IS | | REQUIRED ON ROOF.ACCORDING TO SEC. R806 OF 2004 | | FLORIDA RESIDENTIAL CODECROSS VENTILATION IS | | REQUIRED. SPECIFYIN PLANS/ELEVATIONS SIZE AND | | LOCATION OF CROSS VENTILATION. | | | | (2) SPECIFYHOW PROVIDING PROTECTION TO THE FLOOR | | JOIST AS REQUIRED BY SEC. R319 .1 OF 2004 FLORIDA | | RESIDENTIAL CODE. | | | | (3) REVISE SIZE OF FLOOR JOIST TO MATCH SIZE SHOWN | | ON STRUCTURAL PLANS. | | | | 9- SHEET S-2:REVISE NOTES ON TYPICAL WIND PRESSURE | | BOX SHOWN ON THE FLOOR PLAN D.DISTANCE "A" TO BE | | 4'-0" MIN. AS REQUIRED BY NOTE A ON FIGURE R301.2(8) OF | | 2004 FLORIDA RESIDENTIAL CODE. | | ***NOTE:REVISE SAME INFORMATION ON SHEET S-3. | | | | 10- OWES $5.02 FOR RADON FEES FOR NEW ADDITION. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-09-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-09-29 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-09-29 |
Time |
13:31 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-08-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-18 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-18 |
Time |
15:13 |
Sent To |
B |
|
Notes |
2008-08-18 15:53:52 | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE 200 AMP SERVICE IS ADEQUATE HOWEVER THE LOAD | | CALCULATIONS AT 153 AMPS ALL SEEMS TO BE IN THE 100 AMP | | PANEL "B". SEE SHEET E-2. VIOLATION OF ARTICLE 408.30 " | | ALL PANELBOARDS SHALL HAVE A RATING NOT LESS THAN THE | | MINIMUM FEEDER CAPACITY REQUIRED FOR THE LOAD | | CALCULATED IN ACCORDANCE WITH ARTICLE 220".THE | | CONDUCTORS ARE ALSO TOO SMALL FOR THE LOAD PER 310.16. | | | | 2} CIRCUIT 1,3 FOR THE "EXISTING A/C" HAS A 5.8 KW | | LOAD, #8 WIRE ON A 60 AMP OCP. 5800/240=24 AMPS X 1.25% | | (ARTICLE 424.3(B) )=30.2 AMPS.PER 240.6(A) A 35 AMP | | BREAKER WOULD BE THE MAXIMUM PERMITTED.ALSO SEE SHEET | | M-1 INDICATING A NEW 5 KW AIR HANDLER IS TO BE | | INSTALLED.CORRELATE THE SHEETS WITH THE CORRECT | | INFORMATION. | | | | 3} CIRCUIT #30, PANEL "B" IS LISTED AS LAUNDRY BUT | | APPEARS TO BE A SMALL APPLIANCE CIRCUIT ON SHEET | | E-1.PLEASE CLARIFY. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2008-10-01 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-10-01 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-10-01 |
Time |
10:38 |
Sent To |
PC |
|
Notes |
2008-10-01 10:44:08 | ****************PROVISO**************** | | *INFORMATION ONLY* | | NOTE: PER PHONE CONVERSATION WITH CONTRACTOR PAUL | | NEWMAN THE GAS ISOMETRIC ON SHEET P-1 HAS BEEN REMOVED | | FROM THE PLANS. A SEPERATE GAS PERMIT AND PLANS WILL BE | | APPLIED FOR AT A LATER DATE. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2008-09-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-09-25 |
Time |
09:09 |
Rev Time |
0.30 |
Received By |
mperson |
Date |
2008-09-25 |
Time |
09:09 |
Sent To |
E |
|
Notes |
2008-09-25 09:34:46 | GAS PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. PLEASE KNOW | | THAT THE RESUBMITTED GAS ISOMETRIC HAS A DIFFERENT | | DESIGN FROM THE ORIGINAL REVIEWED. PLEASE KNOW THAT THE | | FOLOWING COMMENTS ARE FOR SHEET P-1 GAS ISOMETRIC. | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE SECTION 401.1 SCOPE. | | *NOTE: THE RESUBMITTED GAS ISOMETRIC DOES NOT INDICATE | | CORRESPONDING LENGTHS TO ALL CUT SECTIONS OF PIPE. | | PLEASE REFERENCE THE YELLOW HIGH LIGHTED CUT SECTIONS | | INDICATING THIS. | | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | *NOTE: THE RESUBMITTED GAS ISOMETRIC IS INDICATING A | | TOTAL DISTANCE OF 7'-0", HOWEVER THERE IS NO WAY TO | | VERIFY THE TOTAL DISTANCE WITHOUT COMMENT #1 BEING | | ADDRESSED. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-10-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-15 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-15 |
Time |
11:31 |
Sent To |
B |
|
Notes |
2008-10-15 11:31:52 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-09-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-19 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-19 |
Time |
09:08 |
Sent To |
Z |
|
Notes |
2008-09-19 09:09:01 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-08-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-08-21 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-08-08 |
Time |
16:23 |
Sent To |
|
|
Notes |
2008-08-08 16:25:03 | TO "SFR" "Z" |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2008-09-24 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-09-24 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-09-24 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-09-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-09-30 |
Time |
08:21 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-09-30 |
Time |
08:21 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-08-14 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-14 |
Time |
11:27 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-08-14 |
Time |
11:27 |
Sent To |
E |
|
Notes |
2008-08-14 11:55:30 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) SEE MECHANICAL PLAN PAGE M-1. PLEASE MAKE THE FLOOR | | PLAN OF THE HOUSE DARKER AS OUR ELECTRONIC SCANNER FOR | | RECORD RETENTION WILL NOT BE ABLE TO RECORD IT, PER | | 2004 W.P.B. AMEND. 106.1.3. | | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC | | 13-101.2.2. SHORT FORM 600C-04 MAY BE USED AS THE | | ADDITION IS UNDER 600 SQ. FT., SEE 2004 FBC | | 13-600.3.C. | | | | 3) PLEASE SUBMITCOOLING LOAD CALCULATIONS FOR THE | | ADDITION, IF SUBMITTED FOR THE WHOLE HOUSE PLEASE | | SEPARATE EXISTING HOUSE FROM ADDITION BY ZONES, ON | | CALCULATIONS ONLY. PER 2004 FBC 13-607.1.ABC.1. | | | | 4) THE RETURN AIR MAY NOT BE TAKEN FROM THE KITCHEN, | | PER 2004 FBC/R M1601.6.4.5 (A RETURN AIR DUCT MAY BE | | RAN TO THE DINING ROOM). | | | | 5) PLEASE ADD AN EQUIPMENT SCHEDULE TO THE PLAN SHOWING | | THE PERTINENT INFORMATION FOR THE NEW AIR HANDLER, PER | | 2004 W.P.B. AMEND. 106.3.5.4 (10). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-09-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-09-25 |
Time |
09:07 |
Rev Time |
0.30 |
Received By |
mperson |
Date |
2008-09-25 |
Time |
09:07 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-08-13 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-14 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-13 |
Time |
16:37 |
Sent To |
M |
|
Notes |
2008-08-13 16:58:44 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET P-1 SANITARY ISOMETRIC AND PLUMBING FLOOR | | PLAN: PLEASE CORRECT THE FOLLOWING PER THE FBC-2004 | | PLUMBING CODE SECTIONS. | | | | A} THE WASHING MACHINE MUST DRAIN DOWN STREAM OF THE | | NEW MATER BATH WET VET. ONLY FIXTURES WITHIN THE | | BATHROOM GROUPS SHALL CONNECT TO THE WET-VENTED | | HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL FIXTURES SHALL | | DISCHARGE DOWNSTREAM OF THE WET VENT. PER SECTION 909.1 | | WET VENT PERMITTED. | | | | B} CLEARLY INDICATE THE SIZE TO ALL FIXTURE TRAPS | | (WASHING MACHINE MINIMUM 2" AND LAVATORY MINIMUM 1-1/4" | | TRAPS ARE NOT SIZED). PER SECTION 701.1 SCOPE. | | | | C} CLEARLY INDICATE THE CLEANOUT AT THE JUNCTION OF | | THE BUILDING DRAIN AND BUILDING SEWER AS BEING A | | TWO-WAY CLEANOUT. PER SECTION 708.3.5 BUILDING DRAIN | | AND BUILDING SEWER JUNCTION. | | | | 2. SHEET P-1 PLUMBING FLOOR PLAN IS TO LIGHT AND HARD | | TO READ, PLEASE CORRECT. PER (W.P.B. AS AMENDED) | | SECTION 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 3. SHEET P-1 GAS ISOMETRIC: PLEASE KNOW THAT THE | | CORRECT SIZING TABLE IS 402.4(2) NOT 402.4(1) DUE TO | | FLORIDA PUBLIC UTILITIES PROVIDING A 12" WC WITH A .5" | | PRESSURE DROP. PER FBC-2004 FUEL GAS TABLE 402.4(2). | | | | 4. PLEASE KNOW THAT ENERGY CALCULATIONS FOR THE NEW | | TANKLESS WATER HEATER AND HOT WATER PIPE INSULATION ARE | | REQUIRED. PER FBC-2004 CHAPTER 13 SECTION 13-612.1.C.1 | | ADDITIONS, TABLE 13-612.1.ABC.3.2 MINIMUM PERFORMANCE | | STANDARDS WATER HEATING EQUIPMENT, AND TABLE | | 611.1.ABC.1 MINIMUM PIPE INSULATION. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-09-24 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-09-24 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-09-24 |
Time |
11:16 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-08-12 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-08-12 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-08-12 |
Time |
10:41 |
Sent To |
P |
|
Notes |
2008-08-12 10:42:20 | **ZONING FAILED ** | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | 2. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | THE ZLDRS. | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | THE ZLDRS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR | | [email protected] | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT |
|
|