Plan Review Stops For Permit 08070835 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-05-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-05-13 |
Time |
13:11 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2009-05-13 |
Time |
12:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-11-24 |
Time |
12:52 |
Rev Time |
1.66 |
Received By |
jwitmer |
Date |
2008-11-24 |
Time |
12:52 |
Sent To |
|
|
Notes |
2008-11-24 13:09:46 | BUILDING PLAN REVIEW | | PERMIT: 08070835 | | ADD: 1256 PALM BEACH LAKES BLVD. | | CONT: MASTER CONSTRUCTION | | TEL: (561)248-5498 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | INSPECTION. NOC FILED ON 7/22/08 WILL NEED TO BE FILED | | OVER 90 DAY OLD NO WORK. | | | | NOTE!!! THE PERMIT APPLICATION INDICATES THIS PERMIT IS | | TO FINISH WORK STATED UNDER THE EXPIRED PERMIT 05070295 | | BUT THE PLANS INDICATE THE TOTAL SCOPE OF THE | | PROJECT.I'VE SPOKE WITH THE BUILDING OFFICIAL NEIL | | MELICK ABOUT THIS PROJECT. NEIL ADVISED EITHER THE | | CONTRACTOR TO PROVIDE A LETTER INDICATING THE SCOPING | | OF WORK TO BE COMPLETED UNDER THIS PERMIT. THE CHIEF | | INSPECTOR KEN CONRAD TO MAKE A JOBSITE VISIT TO CONFIRM | | THE SCOPING INDICATED WITHIN THE LETTER REFLECTS THE | | CORRECT AMOUNT OF WORK LEFT TO COMPLETEE THE PROJECT. | | WE WILL BE REVIEWING THE REMAINDER OF THE PROJECT UNDER | | THE 2004 FLORIDA BUILDING CODE, EXISTING BUILDING CODE. | | LETTER FROM THE CONTRACTOR FOR THE REMAINDER OF WORK TO | | BE COMPLETED UNDER THIS PERMIT IS ATTACHED TO PLAANS | | AND PERMIT APPLICATION. | | AS STATED IN THE CONTRACTORS LETTER SUB-PERMITS WILL | | ALSO NEED TO BE REAPPLIED FOR: ELECTRIC,PLUMBING, | | MECHANICAL, FIRE SPRINKLER, ROOFING, DUMPSTER ENCLOSURE | | AND SIGNAGE. | | | | 2) 2ND REQUEST, THE DESIGNER WILL NEED TO UPDATE THE | | PLANS TO READ THE DESIGN NOT TO THE CURRENT CODE BUT TO | | THE 2004 FBC EXISTING BUILDING CODE 301.5 THE DESIGN | | PROFESSIONAL SHALL ELECT TO WHAT LEVEL ALTERATION THEY | | ARE DESIGNING TOO. LEVEL 1, LEVEL 2 OR LEVEL3. | | | | 3) 2ND REQUEST, PLANS SUBMITTED DO NOT HAVE ANY ENERGY | | CALCULATIONS SUBMITTED, 2004 FBC EXISTING BUILDING CODE | | SECTION 611.1 MINIMUM REQUIREMENTS. ALTERATIONS SUBJECT | | TO THIS CHAPTER SHALL COMPLY WITH THE REQUIREMENTS OF | | CHAPTER 13 OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 4) COMPLIED. | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-08-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-08-13 |
Time |
10:31 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2008-08-13 |
Time |
10:31 |
Sent To |
|
|
Notes |
2008-08-13 10:42:00 | BUILDING PLAN REVIEW | | PERMIT: 08070835 | | ADD: 1256 PALM BEACH LAKES BLVD. | | CONT: MASTER CONSTRUCTION | | TEL: (561)248-5498 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | 1C) INFORMATIONAL 106.1.1* W.P.B. ADMINISTRATIVE | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | 1D ) INFORMATIONAL FL S S 713.13 NOTICE OF | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | INSPECTION. | | | | 1E) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | NOTE!!!! THE PERMIT APPLICATION INDICATES THIS PERMIT | | IS TO FINISH WORK STATED UNDER THE EXPIRED PERMIT | | 05070295 BUT THE PLANS INDICATE THE TOTAL SCOPE OF THE | | PROJECT.I'VE SPOKE WITH THE BUILDING OFFICIAL NEIL | | MELICK ABOUT THIS PROJECT. NEIL ADVISED EITHER THE | | CONTRACTOR TO PROVIDE A LETTER INDICATING THE SCOPING | | OF WORK TO BE COMPLETED UNDER THIS PERMIT. THE CHIEF | | INSPECTOR KEN CONRAD TO MAKE A JOBSITE VISIT TO CONFIRM | | THE SCOPING INDICATED WITHIN THE LETTER REFLECTS THE | | CORRECT AMOUNT OF WORK LEFT TO COMPLETEE THE PROJECT. | | WE WILL BE REVIEWING THE REMAINDER OF THE PROJECT UNDER | | THE 2004 FLORIDA BUILDING CODE, EXISTING BUILDING CODE. | | LETTER FROM THE CONTRACTOR FOR THE REMAINDER OF WORK TO | | BE COMPLETED UNDER THIS PERMIT IS ATTACHED TO PLAANS | | AND PERMIT APPLICATION. | | AS STATED IN THE CONTRACTORS LETTER SUB-PERMITS WILL | | ALSO NEED TO BE REAPPLIED FOR: ELECTRIC,PLUMBING, | | MECHANICAL, FIRE SPRINKLER, ROOFING, DUMPSTER ENCLOSURE | | AND SIGNAGE. | | | | 2) THE DESIGNER WILL NEED TO UPDATE THE PLANS TO READ | | THE DESIGN NOT TO THE CURRENT CODE BUT BE SPECIFIC AS | | TO THE DESIGN CRITERIA. 2004 FBC EXISTING BUILDING CODE | | 301.5 THE DESIGN PROFESSIONAL SHALL ELECT TO WHAT LEVEL | | ALTERATION THEY ARE DESIGNING TOO. | | | | 3) PLANS SUBMITTED DO NOT HAVE ANY ENERGY CALCULATIONS | | SUBMITTED, 2004 FBC EXISTING BUILDING CODE SECTION | | 611.1 MINIMUM REQUIREMENTS. ALTERATIONS SUBJECT TO THIS | | CHAPTER SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER | | 13 OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 4) THE FIRE AREA OF THIS BUILDING IS OVER 12,000 SQ FT | | REQUIRING FIRE SPRINKLERS, IN 903.2.6(1). THE EXISTING | | BUILDING CODE SECTION 601.2 IN ADDITION TO THE | | REQUIREMENTS TO THEREQUIEMENTS OF THIS CHAPTER, ALL | | WORK SHALL COMPLY WITH CHAPTER 5 OF THE EXISTING | | BUILDING CODE. SECTION 504.1 LEVEL 1 ALTERATIONS SHALL | | NOT BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF | | FIRE PROTECTION PROVIDED. PLEASE SUBMIT PLANS FOR FIRE | | SPRINKLERS TO MEEET THE REQUIREMENTS OF 903.2.6(1) AND | | 504.1 EXISTING BUILDING CODE. NOTE SEPERATE PLANS WILL | | ALSO BE REQUIRED FOR THE FIRE SPRINKLER PERMIT. | | | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | | | | | | | | | | | | | | | | | | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2009-05-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-07 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-07 |
Time |
14:39 |
Sent To |
|
|
Notes |
2009-05-07 14:39:54 | **PROVISO PLANS** | | | | | | | | 1) NOTE: PLEASE COMPLETE ALL CIRCUITING ON PLANS AND | | COORDINATE WITH THE SUBMITTED PANEL SCHEDULES. | | | | RTU FOR CIRCUITS L20,20,24 ON PANEL, HOWEVER NOT THE | | SAME ON PLANS | | RECEPTACLE IN TENANT SPACE NO CIRCUIT. ( NEXT TO A | | PANEL.) | | EM LIGHT IN TENANT SPACE WHICH SHOULD BE ON L PANEL IS | | SHOWN CIRCUITED TO A-29. MUST BE IN THE SAME TENANT. | | LIGHT FIXTURES IN OFFICES AND BATHROOM SHOW NOW | | CIRCUITS. | | OTHER CIRCUITS SUCH AS THE RECEPTACLES SHALL BE | | SPECIFIC. STATING *RECEPTACLES* IS NOT ACCEPTABLE. | | PLEASE SEE COMMENTARY IN THE 2005 NEC UNDER 408.4. FOR | | EXAMPLE: THE RECEPTACLES ALONG THE REAR WALL WOULD | | STATE JUST THAT; * RECEPTACLES REAR WALL* OR WORDS TO | | THAT SAME AFFECT. | | | | 408.4, FBC 106.1.1, 106.3.5 | | | | ** ANY AND ALL LOW VOLTAGE SHALL BE UNDER SEPARATE | | PERMITS, FEES AND PLANS. | | | | ** THE PLANS MUST BE UPDATED, SUBMITTED AS A REVISION | | AND ON-SITE BEFORE INSPECTIONS. PLEASE KEEP IN MIND, | | RE-INSPECTION FEES WILL BE ASSESSED PER BUILDING | | OFFICIAL IF PLANS ARE NOT REVISED BEFORE INSPECTIONS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-12-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-12-01 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-12-01 |
Time |
11:24 |
Sent To |
|
|
Notes |
2008-12-01 11:24:43 | | | ** FAILED REVIEW | | | | | | 1) NOTE: THE SUBMITTED ENERGY CALCULATIONS ARE DONE | | UNDER THE INCORRECT VERSION NOT ADOPTED BY THE FBC. | | PLEASE SEE FBC 13-400.A.3 | | PLEASE GO THE ENERGY GAUGE WEBSITE AS IT IS UNDERSTOOD | | BY THIS OFFICE THERE IS A PATCH AVAIL FOR THE CORRECT | | VERSION OF 2.5. IT IS ALSO UNDERSTOOD THAT THERE IS NO | | FEE ASSOCIATED WITH THE PATCH. THIS IS BASED ON | | INFORMATION GIVEN BY NUMEROUS DESIGNERS WHICH HAVE HAD | | TO UPDATE THE VERSION. | | | | 2) NOTE: PLEASE SEE THAT METHOD *A* SUBMITTED FOR THE | | OFFICE SPACE IS NOT APPLICABLE.13-101. THE TENANT SPACE | | IS NOT A WHOLE BUILDING. | | PLEASE COORDINATE ALL ELECTRICAL ON PLANS AND OTHER | | COMPONENTS WITH THE SUBMITTED INPUT DATA REPORT. | | PLEASE SEE 13-101.1.6 FOR BUILDINGS WHICH ARE NOT | | COMPLETE. METHODS B OR C ARE THE ONLY CHOICE. NOT *A*. | | PIPING IS NOTED AS BEING INSULATED AS REQUIRED FOR HOT | | WATER HOWEVER THE ELECTRICAL PLANS AS WELL AS THE IDR | | DOES NOT INDICATE ANY INPUT FOR A HOT WATER HEATER? | | | | 3) NOTE: PLEASE KNOW THAT HAND DRAWN ITEMS ARE NOT | | PERMITTED ON PLANS SIGNED, DATED AND SEALED. FS | | 471.025. THIS IS NOT PERMITTED TO PLANS BY ARCHITECT OR | | ANY OTHER DESIGNER RESPONSIBLE FOR DRAWINGS. | | MANY OF THESE HAVE BEEN HIGH-LIGHTED ON PLANS. | | | | 4) NOTE: THE SUBMITTED ENERGY CALCULATIONS MAKE NOTE TO | | LIGHTING CONTROL PANEL/CENTRAL CONTROLS HOWEVER THE | | PLANS DO NOT INDICATE THE LIGHTING CONTROLS AS | | REQUIRED. 13-415.1.ABC.1.1,.1.2, .1.3 AND .1.4. | | | | 5) NOTE: PLEASE COORDINATE ALL CIRCUITING ON PLANS WITH | | THE PANEL SCHEDULES. ONE EXAMPLE IS THE SIGN CIRCUIT | | WHICH PER 600.5 IS REQUIRED AT THE FRONT ENTRANCE FOR | | EACH SPACE AND IS REQUIRED TO BE ON DEDICATED | | CIRCUIT(S). | | PLEASE SEE ONE TENANT WHICH HAS CIRCUIT A-17 SHOWN AS | | GFI FOR SOME DEVICE. | | | | ** PLEASE KNOW AS THERE ARE SEVERAL ITEMS NOT YET | | COMPLETE OR ON PLANS FOR REVIEW A COMPLETE REVIEW OF | | SOME COULD NOT BE DONE AT THIS TIME. PLEASE BE SURE TO | | CALL TO GO OVER ANY QUESTIONS. | | | | | | | | | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-08-27 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-08-27 |
Time |
16:26 |
Sent To |
|
|
Notes |
2008-08-27 16:26:50 | ** PLANS WERE ON HOLD. REMOVED FROM HOLD ON 8/26 | | | | | | **DENIED** | | | | | | | | 1) NOTE: PLEASE SUBMIT PLANS UNDER MINIMUM DESIGN FOR | | THE FOLLOWING CODES. | | | | 2004 FBC W/2007 REVISIONS | | 2003 NFPA-101 | | 2005 NFPA-70 | | 2002 NFPA-72 | | | | *** PLEASE BE SURE TO SEE COMPLIANCE WITH THE CURRENT | | FLORIDA BUILDING CODE AND ALL OF CHAPTER 13 IS | | REQUIRED. | | PLEASE BE SURE TO COMPLETE PLANS FOR ALL OTHER | | REQUIREMENTS. | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | CONTACT THIS REVIEWER. | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2009-04-29 |
Time |
|
Rev Time |
2.00 |
Received By |
mgonzale |
Date |
2009-04-29 |
Time |
11:00 |
Sent To |
|
|
Notes |
2009-04-29 14:35:10 | *** PASSED WITH PROVISO *** | | | | DUMPSTER DETAIL DOES NOT SHOW DIMENSIONS. | | DUMPSTER MUST CONFORM TO MIMIMUM CITY WPB STANDARD. | | LATEST DETAIL MAY BE FOUND AT THE LINK BELOW. DETAIL | | GC-9 | | | | HTTP://WWW.WPB.ORG/ENGINEERING/STANDARDS/ENGINEERING_ST | | ANDARDS_TABLE_CONTENTS.PDF | | | | NOTE: PLEASE ALSO KNOW THAT ADDITIONAL PERMIT IS | | REQUIRED FOR FIRELINE PIPING ON-SITE. UNDERGROUND | | PERMIT. | | SUCH PIPING WILL BE INSPECTED AND CERTIFIED BY ENGINEER | | OF RECORD. | | | | REVIEWED BY [email protected] | | ENGINEERING SECTION | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2008-11-19 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2008-11-19 |
Time |
09:26 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2008-11-19 |
Time |
09:22 |
Sent To |
|
|
Notes |
2008-11-19 09:26:08 | - FAILED - | | | | PLEASE BE ADVISED THAT YOU MUST GET YOUR FIRELINE PLANS | | APPRPVED BY CWPB ENGINEERING. | | PLEASE MAKE CONTAC WITH: | | | | MANUEL J GONZALEZ, PROJECT COORDINATOR (561) 494-1040 | | LOCATION ADDRESS: | | CITY OF WEST PALM BEACH | | ENGINEERING SERVICES DEPARTMENT | | 1000 - 45TH STREET, SUITE 15 | | WEST PALM BEACH FL 33407 | | MAILING ADDRESS: | | CITY OF WEST PALM BEACH | | ENGINEERING SERVICES DEPARTMENT | | P.O. BOX 3506 | | WEST PALM BEACH FL 33401 | | TELEPHONE: | | 45TH STREET OFFICE : 561-494-1040 | | 45TH DIRECT: 561-494-1085 | | FAX: 561-494-1117 | | CITY HALL OFFICE: (561) 805-6723 | | CITY HALL DIRECT: (561) 805-6327 | | CITY HALL FAX: (561) 805-6731 OR 805-6676 | | NEXTEL: 561-644-7301 | | NEXTEL DIRECT CONNECT: 159*28165*38 | | EMERGENCIES: | | CENTRAL OPERATIONS CENTER (DISPATCH) 561-822-2210 | | E-MAIL: | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2009-05-15 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2009-05-15 |
Time |
14:15 |
Sent To |
|
|
Notes |
2009-05-15 15:11:54 | *****APPROVED***** | | | | | | AFTER RECEIVING THE REQUESTED ADDITIONAL INFORMATION | | FOR THE SUBMITTED PLAN SETS, SHEETS A2, A3, AND MEP1 | | WERE STAMPED, INITIALED, AND DATED ON 5/21/2009. | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-12-03 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-12-03 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-12-03 |
Time |
15:12 |
Sent To |
|
|
Notes |
2008-12-03 15:21:23 | ***DENIED*** | | | | SOME OF THE COMMENTS FROM THE FIRST REVIEW HAVE BEEN | | ADDRESSED. PLEASE SEE THE FOLLOWING COMMENTS: | | | | 1) PROVIDE COMPLETE ADDRESS INCLUDING NUMERICAL ON EACH | | SHEET SUBMITTED. | | | | 2) PLANS INDICATE THAT PROJECT WILL BE PROTECTED BY AN | | AUTOMATIC FIRE SPRINKLER SYSTEM. IN ADDITION TO THE | | SEPARATE SHOP DRAWINGS AND PERMIT, PLEASE SHOW | | SPRINKLER LAYOUT WITH THIS SUBMITTAL. SPRINKLERS MAY BE | | SHOWN ON REFELECTED CEILING PLAN. COMMENT TAKEN FROM | | FIRST REVIEW. | | | | 3) PLANS REFERENCE WORK TO COMPLY WITH NFPA 72, 2002. | | PLEASE CLARIFY IF BUILDING WILL BE PROVIDED WITH FIRE | | ALARM SYSTEM. INFORMATION INCLUDED SHOULD BE LIMITED TO | | WORK THAT IS RELEVANT TO THIS PROJECT. | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-08-28 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-08-28 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-08-28 |
Time |
13:48 |
Sent To |
P |
|
Notes |
2008-08-28 14:03:28 | ***DENIED*** | | | | 1) SOME SHEETS ARE DIFFICULT TO READ. FBC 106.1.1 | | REQUIRES CONSTRUCTION DOCUMENTS TO BE OF SUFFICIENT | | CLARITY TO REVIEW FOR CODE COMPLIANCE AND CONFORMANCE | | WITH RELEVANT LAWS, ORDINANCES RULES AND REGULATIONS. | | | | 2) IN ADDITION TO APPLICABLE BUILDING CODES, LIFE | | SAFETY SHALL COMPLY WITH NFPA 101, 2003. | | | | 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | WITH NFPA 241. | | | | 4) PROVIDE MINIMUM INTERIOR FINISH CLASSIFICATION FOR | | WALLS AND CEILING. | | | | 5) FIRE SPRINKLER SYSTEMS ARE REQUIRED FOR MERCANTILE | | OCCUPANCIES EXCEEDING 12,000 SQ'. NFPA 101, SEC. | | 36.3.5.1 (2). PROVIDE FIRE SPRINKLER LAYOUT AS REQUIRED | | BY FBC. ADDITIONALLY, SEPARATE SHOP DRAWINGS AND PERMIT | | REQUIRED PRIOR TO SYSTEM INSTALLATION. | | | | 6) ADDRESS SHALL BE MINIMUM OF 6" IN HEIGHT, 1" WIDTH | | AND CONTRASTING WITH BACKGROUND FOR COMMERCIAL | | BUILDINGS. | | | | 7) PROVIDE LOCATION OF REQUIRED 2A-10B,C RATED FIRE | | EXTINGUISHERS. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-07-31 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-07-31 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-07-31 |
Time |
15:12 |
Sent To |
FIRE |
|
Notes |
2009-07-31 15:12:50 | TO FIRE IN BOX | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-07-31 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-26 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-26 |
Time |
10:45 |
Sent To |
|
|
Notes |
2009-05-26 10:52:00 | TO MAGGIE FOR KELLEY./WRT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-04-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-28 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-28 |
Time |
16:57 |
Sent To |
|
|
Notes |
2009-04-28 17:00:44 | TO C-2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-11-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-10 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-10 |
Time |
08:29 |
Sent To |
|
|
Notes |
2008-11-10 08:33:14 | TO "COMM" BD#53 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-08-28 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-08-28 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-07-31 |
Time |
08:56 |
Sent To |
|
|
Notes |
2008-07-31 09:01:40 | TO "COMM" BD#62 |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
3 |
Status |
P |
Date |
2009-06-08 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-06-08 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-06-08 |
Time |
10:31 |
Sent To |
|
|
Notes |
2009-06-08 10:31:43 | SEE PLANNING PROVISOS. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
F |
Date |
2009-05-13 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2009-05-13 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2009-05-13 |
Time |
10:42 |
Sent To |
|
|
Notes |
2009-05-13 10:43:54 | ***LANDSCAPE REVIEW FAILED*** | | | | SEE 5/1/09 ZONING COMMENTS AND PREVIOUS LANDSCAPE | | COMMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | KUSSNER @ (561) 822-1462, |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2008-11-18 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-11-18 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-11-18 |
Time |
15:37 |
Sent To |
|
|
Notes |
2008-11-18 15:37:29 | ***LANDSCAPE REVIEW FAILED*** | | | | 1. LANDSCAPE PLAN MUST BE SIGNED AND SEALED BY A | | REGISTERED LANDSCAPE ARCHITECT. | | | | 2. PURSUANT TO SECTION 94-445(4)(A), SHADE AND | | FLOWERING TREES SHALL BE A MINIMUM OF EIGHT FEET IN | | HEIGHT AND POSSESS A MINIMUM OF FIVE FEET OF CLEAR | | TRUNK SPACE. THE CREPE MYRTLE TREES DO NOT MEET THIS | | REQUIREMENT. | | | | 3. PURSUANT TO SECTION 94-443(C)(3)A, EACH ROW OF | | PARKING SPACES SHALL BE TERMINATED BY LANDSCAPED | | ISLANDS OF NOT LESS THAN FIVE FEET IN WIDTH (EXCLUDING | | THE REQUIRED CURB) AND NOT LESS THAN THE LENGTH OF THE | | ADJACENT PARKING STALL. THE LANDSCAPED ISLAND SHALL | | HAVE A MINIMUM RADIUS OF 21/2 FEET AT ITS END SO AS TO | | ALLOW CAR MANEUVERING. THE LANDSCAPED ISLAND SHALL | | CONTAIN AT LEAST ONE SHADE OR FLOWERING TREE. THE | | PARKING ROW EAST OF THE MAIN ENTRY, ADJACENT TO THE | | HANDICAP PARKING STALL IS MISSING THE REQUIRED | | LANDSCAPE ISLAND AND TREE AT THE WEST END. A TREE IS | | MISSING IN THE TERMINAL LANDSCAPE ISLAND AT THE EAST | | END OF THAT PARKING ROW. | | | | 4. THE CAR STOPS SHALL BE ELIMINATED ALONG THE WEST AND | | NORTH PERIMETER OF THE SITE AND REPLACED WITH CURBING. | | THE ASPHALT SHALL BE REMOVED WITHIN THE 2 FOOT OVERHANG | | AREA. THIS WILL ALLOW ADDTIONAL GREEN SPACE FOR THE | | ROOTS OF THE TREES TO DEVELOP. NO TREES OR SHRUBS CAN | | BE PLANTED WITHIN THE 2 FOOT OVERHANG AREA. | | | | 5. THE PERIMETER HEDGE ALONG THE WEST PERIMETER OF THE | | SITE SHALL BE PLACED ALONG THE INSIDE PERIMETER OF THE | | LANDSCAPE BUFFER WITH SOD OR GROUND COVER PLANTED ALONG | | THE STREET SIDE OF THE HEDGE. THE HEDGE ALONG THE NORTH | | PERIMETER OF THE SITE SHALL BE PLANTED ALONG THE | | PROPERTY LINE WITH SOD OR GROUND COVER PLANTED ALONG | | THE INSIDE OF THE LANDSCAPE BUFFER. | | | | 6. PROVIDE THE TABULATION NECESSARY TO DEMONSTATE | | COMPLIANCE WITH ARTICLE XIV OF THE CITY OF WEST PALM | | BEACH ZONING AND LAND DEVELOPMENT REGULATIONS. THE PLAN | | REFERENCED COUNTY REQUIREMENTS WHICH HAS NOTHING TO DO | | WITH CITY REQUIREMENTS. | | | | 7. PROVIDE THE TABULATION NECESSARY TO DEMONSTRATE | | COMPLIANCE WITH SECTION 94-442(G) "XERISCAPE | | REQUIREMENT". | | | | 8. PURSUANT TO SECTION 94-442(D), PRIVATE LAND AND | | PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK | | SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN | | SPACE AREAS SHALL BE PLANTED WITH GRASS. THIS APPLIES | | TO THE AUSTRALIAN AVENUE RIGHT-OF-WAY. ALL LANDSCAPED | | AREAS SHALL BE IRRIGATED, INCLUDING THE RIGHT-OF-WAY | | AREAS. | | | | 9. PURSUANT TO SECTION 94-442(B)(1), ALL OPEN SPACE, | | EXCLUDING VEHICULAR AND PEDESTRIAN CIRCULATION FEATURES | | AND SURFACE PARKING, SHALL BE COVERED WITH GRASS, | | GROUND COVER, SHRUBBERY, OR OTHER SUITABLE PLANT | | MATERIAL. THE LANDSCAPE ISLANDS SHALL EITHER BE | | COMPLETELY COVERED WITH GROUND COVER OR SOD. MULCH, | | WITHOUT PLANTING, IS NOT ACCEPTABLE. | | | | 10. THE SPECIES OF OAK PROPOSED DOES NOT GROW IN THIS | | ZONE. PLEASE CHANGE THE SPECIES. | | | | 11. YOU SHALL COMPLY WITH FPL'S "PLANT THE RIGHT TREE | | IN THE RIGHT PLACE" PROGRAM. PLEASE SHOW ALL OVERHEAD | | POWER LINES. OAK TREES CANNOT BE PLANTED WITHIN 30 FEET | | OF OVERHEAD LINES. | | | | 12. ON THE LANDSCAPE PLAN, PLEASE PROVIDE THE LOCATION | | OF ALL SITE LIGHTING, UTILITIES AND ANYTHING ELSE THAT | | MAY INTERFERE WITH THE PROPOSED TREES. | | | | 13. PROVIDE THE DUMPSTER LOCATION AND DETAILS OF HOW IT | | WILL BE FULLY SCREENED. | | | | 14. PROVIDE THE QUANTITY OF PLANTS IN EACH LOCATION. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CONTACT ROBERT | | KUSSNER @(561) 822-1462. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2009-05-14 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-05-14 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-05-14 |
Time |
13:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2008-11-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-11-12 |
Time |
11:41 |
Rev Time |
1.00 |
Received By |
tgordon |
Date |
2008-11-12 |
Time |
11:41 |
Sent To |
|
|
Notes |
2008-11-12 11:56:25 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | | | 1) PLAN MEP4 WAS NOT PART OF THE REVISED PLANS. PLEASE | | REVISE PLAN TO INCLUDE AN A/C EQUIPMENT SCHEDULE WITH | | ALL THE PERTINENT INFORMATION ON IT, PER 2004 FBC | | 106.3.5. | | | | 2) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS, PER 2004 | | FBC/M 403.2. | | | | 3) SUBMIT COOLING LOAD CALCULATIONS, PER 2004 FBC | | 13-407.1.ABC.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-08-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-12 |
Time |
14:42 |
Rev Time |
1.30 |
Received By |
tgordon |
Date |
2008-08-12 |
Time |
14:42 |
Sent To |
|
|
Notes |
2008-08-12 15:30:54 | PLAN REVIEW UNDER THE 2001 FLORIDA BUILDING CODE, CITY | | OF WEST PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), | | FLORIDA ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA | | STATUTES (F.S.). | | | | *** DENIED *** | | ** WHEN THE MECHANICAL PLAN WAS REVIEW ON APRIL 14,2006 | | A PROVISO WAS ATTACHED TO IT, THE REQUIREDMENTS OF THE | | PROVISO WERE NOT MET SO THE PLAN MUST BE REVISED BEFOR | | A NEW PERMIT CAN BE ISSUED. | | | | 1) RTU-6 IS NOT SHOWN ON PLAN MEP4 EQUIPMENT SCHEDULE, | | PLEASE CORRECT PER 2001 FBC 104.3.1.1. | | | | 2) PLAN MEP-2 SHOW THE SIZE ON THE RETURN AIR DUCT | | (FLEX) TO THE OFFICE (SEE YELLOW HIGH LIGHT ON | | MECHANICAL PLAN). PER 2004 FBC/M 601.4. | | | | 3) CORRECTED. | | | | 4) PLEASE SHOW ON PLANS, COMPLIANCE WITH 2001 FBC/M | | 306.5 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED | | STRUCTURES. | | WHERE EQUIPMENT AND APPLIANCES REQUIRING ACCESS ARE | | INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT A HEIGHT | | EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL BE | | PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, THE | | EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL TO | | THE EQUIPMENT AND APPLIANCES? LEVEL SERVICE SPACE. SUCH | | ACCESS SHALL NOT REQUIRE CLIMBING OVER OBSTRUCTIONS | | GREATER THAN 30 INCHES (762 MM) HIGH OR WALKING ON | | ROOFS HAVING A SLOPE GREATER THAN 4 UNITS VERTICAL IN | | 12 UNITS HORIZONTAL (33-PERCENT SLOPE). | | | | ** ADDITIONAL CORRECTIONS TO BE MADE TO PLAN MEP3. | | | | 5) RTU-6 SHOW THE SUPPLY DUCT (FLEX) AND SIZE, GOING TO | | THE SUPPLY AIR GRILL IN THE OFFICE WITH NO DUCT (SEE | | YELLOW HIGH LIGHT ON MECHANICAL PLAN). | | | | 6) RTU-6 PLAN SHOWS FLEX GOING FROM THE RETURN PLENUM | | TO A MIXING BOX OR IS THAT A GRILL, PLEASE CLARIFY IF | | IT'S A MIXING BOX OR A GRILL, SHOW THE SIZE OF THE FLEX | | AND IF GRILL SHOW SIZE (SEE YELLOW HIGH LIGHT ON | | MECHANICAL PLAN). | | | | 7) RTU-5 SHOW THE SIZE OF THE RETURN AIR GRILL (SEE | | YELLOW HIGH LIGHT ON MECHANICAL PLAN). | | | | 8) RTU-5 PLAN MEP3 SHOWS AN ITEM NEAR THE WALL OF THE | | RESTROOMS (SEE YELLOW HIGH LIGHT ON MECHANICAL PLAN) IS | | THIS A SUPPLY AIR GRILL OR A WATER FOUNTAIN, PLEASE | | CLARIFY. | | | | 9) PLEASE SUBMIT TWO SIGNED AND SEALED COPIES OF | | PLANS. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-05-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-05-05 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-05-05 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-12-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-03 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-03 |
Time |
16:42 |
Sent To |
|
|
Notes |
2008-12-03 16:46:10 | DENIED | | REFERENCE: FBC-2004 CHAPTER 1 | | | | 1. SHT MEP4 FROM SET OF PLANS APPROVED FOR REISSUE ON | | 8-29-08 WERE DELETED FROM THIS SET. PLEASE SUBMIT 2 | | COMPLETE SETS OF PLANS FOR REVIEW. SECTION 106.1. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2008-08-29 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-08-07 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-08-07 |
Time |
10:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2009-06-08 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-06-08 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-06-08 |
Time |
10:29 |
Sent To |
|
|
Notes |
2009-06-08 10:30:57 | ***PROVISO*** | | | | 1. THE LAYOUT OF THE HIGHLIGHTED PARKING AREA SHALL | | MATCH THE ATTACHED DIAGRAM. | | | | 2. ALL CURBING SHALL BE TYPE D. | | | | 3. WHEELSTOPS SHALL BE SINGLE SIDED. | | | | CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435 WITH | | QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2009-05-01 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-05-01 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-05-01 |
Time |
10:40 |
Sent To |
|
|
Notes |
2009-05-01 10:46:32 | ***FAILED*** | | | | 1. THE PARKING LOT LAYOUT IN PK1 AND THE LAYOUT IN L-1 | | ARE INCONSISTENT WITH ONE ANOTHER, ESPECIALLY AGAINST | | THE NORTH SIDE OF THE EXISTING STRIP OF SHOPS. THE SITE | | PLAN SHOWS 8 PARKING SPACES AND THE LANDSCAPE PLAN | | SHOWS 11 SPACES. ADJUST THE LANDSCAPE PLAN TO MATCH THE | | DIMENSIONS AND SPACE COUNTS ON THE SITE PLAN. | | | | 2. IT IS SUGGESTED THAT GROUPS OF 3 SABAL PALM BE | | INSTALLED IN THE EAST AND WEST ISLANDS ALONG THE | | PARKING ROW MENTIONED ABOVE. THEY WILL PROVIDE BETTER | | VERTICAL ELEMENTS AGAINST THE BUILDING AND TIE IN WITH | | THE SABALS ON THE SIDE FACING AUSTRALIAN AVE. | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT | | [email protected] OR 561-822-1458 WITH QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-11-18 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-11-18 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-11-18 |
Time |
14:57 |
Sent To |
|
|
Notes |
2008-11-18 15:02:20 | ***FAILED*** | | | | 1. PLEASE SHOW THE LOCATION OF THE DUMPSTER AND | | CODE-COMPLIANT SCREENING IN CONFORMANCE WITH THE ZONING | | CODE. | | | | 2. A PARKING LOT STRIPING DETAIL SHALL BE PROVIDED THAT | | CONFORMS TO THE ZONING CODE. | | | | NOTE THAT I HAVE ATTACHED DETAIL SHEETS FOR EACH OF THE | | ABOVE REQUIREMENTS. WHEN YOU RESUBMIT, PLEASE SHOW THE | | DETAILS ON THE PLAN PAGES WHERE APPLICABLE. | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435 | | OR [email protected] WITH QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-08-13 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-08-13 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-08-13 |
Time |
15:38 |
Sent To |
|
|
Notes |
2008-08-13 15:39:28 | ***FAILED*** | | | | 1. PLEASE CLEARLY INDICATE THE DIMENSIONS OF DRIVE | | AISLES, PARKING SPACES, AND LANDSCAPE ISLANDS. | | REFERENCE SEC. 94-458(J)(2) FOR MINIMUM AISLE AND | | PARKING SPACE DIMENSIONS. | | | | 2. A DUMPSTER ENCLOSURE MEETING THE DIMENSIONAL | | REQUIREMENTS OF SEC. 94-444 MUST BE PROVIDED. | | | | 3. PLEASE REVIEW THE REQUIREMENTS OF SEC. 94-443(B) FOR | | THE MINIMUM STANDARDS OF THE PERIMETER LANDSCAPE | | BUFFER. IT IS HIGHLY RECOMMENDED THAT THE PROPOSED OAKS | | IN THE NORTH BUFFER BE REPLACED FOR A LOWER GROWING | | SPECIES THAT WILL NOT INTERFERE WITH THE OVERHEAD POWER | | LINES. | | | | 4. THE INTERIOR PARKING LOT LANDSCAPING IS REGULATED BY | | SEC. 94-446(C)(3) AND (5). PLEASE REVIEW THE STANDARDS | | AND MAKE CHANGES ACCORDINGLY. NOTE THAT EACH PARKING | | ROW NEEDS TO BE TERMINATED WITH A LANDSCAPE ISLAND NOT | | LESS THAN 5 FEET IN WIDTH. THE TERMINAL ISLANDS MUST | | EXTEND THE FULL LENGTH OF THE ADJACENT PARKING SPACE | | AND CONTAIN AT LEAST ONE SHADE OR FLOWERING TREE. ALL | | NEW LANDSCAPED AREAS MUST BE PROTECTED FROM VEHICULAR | | ENCROACHMENT BY EITHER TYPE D CURB OR WHEEL STOPS. | | | | 5. PLEASE PROVIDE A LANDSCAPE PLAN MEETING THE | | REQUIREMENTS OF SEC. 94-441 THROUGH SEC. 94-450 AS | | APPLICABLE. | | | | NOTE THAT KELLY FREEMAN, PLANNER, AND ROBERT KUSSNER, | | LANDSCAPE PLANNER, MET WITH THE PROPERTY OWNER AUGUST | | 13, 2008, TO DISCUSS SOME POTENTIAL CHANGES TO THE | | PLANS AND SUPPLIED HER WITH A CONCEPTUAL SKETCH TO | | MODIFY THE PARKING LOT LAYOUT. | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458 | | OR [email protected] WITH QUESTIONS. |
|
|