Plan Review Stops For Permit 08070718 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-10-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-10-08 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-10-08 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-08-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-08-28 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-08-28 |
Time |
10:58 |
Sent To |
|
|
Notes |
2008-08-28 11:00:02 | SEE REVIEW BY JIM WITMER ON PERMIT # 08070721 FOR | | COMMENTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-11-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-11-12 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-11-12 |
Time |
16:15 |
Sent To |
FIRE |
|
Notes |
2008-11-14 15:37:12 | | | | | TOOK OFF BOARD, SENT TO FIRE./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-10-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-10-10 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-10 |
Time |
09:40 |
Sent To |
|
|
Notes |
2008-10-10 09:49:31 | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | REPEAT COMMENTS FROM THE PREVIOUS REVIEW***INDICATES | | FURTHER EXPLANATION OF PREVIOUS COMMENT | | | | 1} THE MANUFACTURERS SPECIFICATION FOR THE GENERATOR | | ARE PARTIALLY INDISCERNIBLE, PLEASE SUBMIT READABLE | | COPIES***THE SAME SPEC'S RESUBMITTED. | | | | 2} THE RESPONSE TO THE PREVIOUS REVIEW COMMENT #3WAS | | THAT THE OCP IS IN THE GENERATOR CONTROL PANEL, THERE | | IS NO INDICATION OF THAT IN THE SPECIFICATIONS | | SUBMITTED.***CORRECT, THE 3000AMP OCP IS NOTED ON SHEET | | E2. | | | | 3} INDICATE IF ANY REQUIRED EMERGENCY LIGHTING OR OTHER | | SYSTMS WILL OPERATE FROM THIS GENERATOR POWER.PROVIDE A | | RISER DIAGRAM INDICATING WHICH PANELS WILL BE FED FROM | | THIS GENERATOR. THE SUBMITTED PLAN SHOWS THE GENERATOR | | FEEDING "MDP."*** NO RESPONSE GIVEN TO THIS COMMENT. | | | | NEW COMMENT GENERATED AS THE DISCONNECTING MEANS IN THE | | NEXGEAR NOW IS THE FIRST MEANS OF DISCONNECT. | | | | 4} SHEET E2, NOTE #9 DOES NOT INCLUDE AN EQUIPMENT | | GROUNDING CONDUCTOR PER 250.130(A) FOR GROUNDED SYSTEMS | | THE CONNECTION SHALL BE MADE BY BONDING THE EQUIPMENT | | GROUNDING CONDUCTOR TO THE GROUNDED SERVICE CONDUCTOR | | AND THE GROUNDING ELECTRODE CONDUCTOR. THEREFORE AS THE | | EQUIPMENT GROUND ORIGINATES FROM THE FIRST MEANS OF | | DISCONNECT IT MUST BE RUN WITH THE FEEDERS FROM | | "NEXGEAR" SWITCHGEAR. "250.32(2)(B) GROUNDED CONDUCTOR | | WHERE (1) AN EQUIPMENT GROUNDING CONDUCTOR IS NOT RUN | | WITH THE SUPPLY TO THE BUILDING OR STRUCTURE, (2) THERE | | ARE NO CONTINUOUS METALLIC PATHS BONDED TO THE | | GROUNDING SYSTEM IN EACH BUILDING OR STRUCTURE | | INVOLVED,".THE CONTINUOUS PATH IS THE CONTROL | | WIRING.SEE SHEET E6 AND E4.***THE NEXGEAR IS THE FIRST | | MEANS OF DISCONNECT SEE 250.24(A)(5). NOT ALL CONTROL | | WIRING WILL GO TO NORMALLY OPEN CONTACTS. SEE NOTES ON | | SHEET *6. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-08-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-04 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-07-30 |
Time |
16:27 |
Sent To |
|
|
Notes |
2008-08-01 16:10:25 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE MANUFACTURERS SPECIFICATION FOR THE GENERATOR | | ARE PARTIALLY INDISCERNIBLE, PLEASE SUBMIT READABLE | | COPIES. | | | | 2} THE RESPONSE TO THE PREVIOUS REVIEW COMMENT #3WAS | | THAT THE OCP IS IN THE GENERATOR CONTROL PANEL, THERE | | IS NO INDICATION OF THAT IN THE SPECIFICATIONS | | SUBMITTED. | | | | 3} INDICATE IF ANY REQUIRED EMERGENCY LIGHTING OR OTHER | | SYSTMS WILL OPERATE FROM THIS GENERATOR POWER.PROVIDE A | | RISER DIAGRAM INDICATING WHICH PANELS WILL BE FED FROM | | THIS GENERATOR. THE SUBMITTED PLAN SHOWS THE GENERATOR | | FEEDING "MDP." | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-11-21 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-11-21 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-11-21 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-10-28 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-28 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-10-28 |
Time |
15:07 |
Sent To |
|
|
Notes |
2008-10-28 15:08:20 | 1) WHAT EQUIPMENT WILL THE GENERATOR SUPPLY WITHIN THE | | STORE? | | | | 2) PLEASE DESCRIBE ANY AND ALL LIFE SAFETY EQUIPMENT | | PLANNED TO BE SUPPLIED BY THE GENERATOR. | | | | 3) IN ADDITION TO APPLICABLE BUILDING CODES, WORK SHALL | | COMPLY WITH NFPA 101, 2003, AND NFPA 110, STANDARD FOR | | EMERGENCY POWER AND STANDBY SYSTEMS. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-08-22 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-08-22 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-08-22 |
Time |
14:09 |
Sent To |
Z |
|
Notes |
2008-08-22 14:14:52 | ***DENIED*** | | | | COMMENTS FROM THE REVIEW OF THE EXPIRED PERMIT WERE | | ADDRESSED, BUT SOME INFORMATION CAN NOT BE FOUND WITH | | THIS SUBMITTAL. | | | | 1) WHAT EQUIPMENT WILL THE GENERATOR SUPPLY WITHIN THE | | STORE? | | | | 2) PLEASE DESCRIBE ANY AND ALL LIFE SAFETY EQUIPMENT | | PLANNED TO BE SUPPLIED BY THE GENERATOR. | | | | 3) IN ADDITION TO APPLICABLE BUILDING CODES, WORK SHALL | | COMPLY WITH NFPA 101, 2003, AND NFPA 110, STANDARD FOR | | EMERGENCY POWER AND STANDBY SYSTEMS. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
FUEL |
DIESEL GENERATOR |
Rev No |
1 |
Status |
P |
Date |
2008-07-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-25 |
Time |
15:03 |
Rev Time |
0.10 |
Received By |
tgordon |
Date |
2008-07-25 |
Time |
15:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-11-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-04 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-04 |
Time |
09:14 |
Sent To |
|
|
Notes |
2008-11-04 09:16:59 | TO "BOB"#3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-10-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-02 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-02 |
Time |
09:10 |
Sent To |
|
|
Notes |
2008-10-02 09:12:00 | TO "COMM" BD#23 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-08-22 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-08-22 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-07-24 |
Time |
13:58 |
Sent To |
|
|
Notes |
2008-08-27 09:35:16 | 8-27-08TO "BUILD" ROBERT MCD. | 2008-07-24 13:58:26 | TO "COMM" BD#12 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2008-07-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-25 |
Time |
15:03 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-07-25 |
Time |
15:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2008-07-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-07-29 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-07-29 |
Time |
15:54 |
Sent To |
|
|
Notes |
2008-07-29 15:57:26 | NOTE: STANBY GENERATOR HAS A FUEL SOURCE OF DIESEL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-08-27 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-08-27 |
Time |
08:52 |
Sent To |
|
|
Notes |
|
|